Abdelrahman A. Karrar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdelrahman A. Karrar has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed H. Eltom
College of Engineering and Computer Science, The University of Tennessee at Chattanooga, Chattanooga, Tennessee United States 37402
2 shared publications Aaron J. Wilson
Department of Electrical Engineering, University of Tennessee at Knoxville, Knoxville, USA
1 shared publicationAmira Abdelgadir
1 shared publicationAnas Ali
University of Tennessee at Chattanooga,Chattanooga,USA
1 shared publicationAreeg Ahmed
University of Tennessee at Chattanooga,Chattanooga,USA
1 shared publication- Babikir Ahmed1 shared publication
Latest Publications
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 12 (2) , 1761-1771
A Compensated Distributed-Parameter Line Decoupling Approach for Real Time Applications
This paper proposes a new method called the Compensated Distributed-Parameter Line Decoupling (CDLD) method, and used for decoupling distribution networks among parallel processing cores in a real-time multi-core environment. Due to the short length of distribution grid lines, decoupling the distribution network for real-time processing is challenging and approaches such as Stublines and State Space Nodal (SSN) solvers have been proposed. Both approaches have limitations and the method proposed in this work addresses these limitations to implement improvements. Specifically, the CDLD method can be used as an enhanced Stubline decoupling, improving on its accuracy and transient response, or it can be combined with an SSN solver to improve its computational performance and remove bottleneck issues. The CDLD method was tested on three IEEE benchmark systems in a real-time environment, and significant improvement was realized in network response and computational performance compared to the prevailing methods. The combined SSN-CDLD method proved to be the most promising approach for network decoupling.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 12 (2) , 1761-1771
A Compensated Distributed-Parameter Line Decoupling Approach for Real Time Applications
This paper proposes a new method called the Compensated Distributed-Parameter Line Decoupling (CDLD) method, and used for decoupling distribution networks among parallel processing cores in a real-time multi-core environment. Due to the short length of distribution grid lines, decoupling the distribution network for real-time processing is challenging and approaches such as Stublines and State Space Nodal (SSN) solvers have been proposed. Both approaches have limitations and the method proposed in this work addresses these limitations to implement improvements. Specifically, the CDLD method can be used as an enhanced Stubline decoupling, improving on its accuracy and transient response, or it can be combined with an SSN solver to improve its computational performance and remove bottleneck issues. The CDLD method was tested on three IEEE benchmark systems in a real-time environment, and significant improvement was realized in network response and computational performance compared to the prevailing methods. The combined SSN-CDLD method proved to be the most promising approach for network decoupling.
- 23 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 11 (5) , 4380-4389
Automated Identification of Electrical Disturbance Waveforms Within an Operational Smart Power Grid
Electric power utilities employ “smart” re-closing devices capable of capturing electrical disturbance (ED) waveforms in real-time. These waveforms are digitally sampled, transmitted back to the utility, and stored in text files that comply with the IEEE COMmon format for TRAnsient Data Exchange (COMTRADE) standard. An average of 2,100 ED events are recorded, by 850 devices, on a monthly basis within Electric Power Board's distribution network. Due to operational restraints such as: time, money, and person power, only 2% of these recorded events are currently analyzed by power utility personnel. The remaining 98% of recorded events remain a significant loss in information, which could be vital in fully understanding the operating condition within the distribution network. This work presents a hierarchical automated classification process that assigns ED events into one of three “categories”: valid data, switching events, and faults/power quality (PQ) disturbances. This process correctly assigned 92.9% of the tested 140 COMTRADE files into one of these categories. In addition to this categorization, this work presents an automated approach for the classification of magnetic inrush events. A classification rate of 90.63% is demonstrated using 32 transformer inrush COMTRADE files.
- 23 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 11 (5) , 4380-4389
Automated Identification of Electrical Disturbance Waveforms Within an Operational Smart Power Grid
Electric power utilities employ “smart” re-closing devices capable of capturing electrical disturbance (ED) waveforms in real-time. These waveforms are digitally sampled, transmitted back to the utility, and stored in text files that comply with the IEEE COMmon format for TRAnsient Data Exchange (COMTRADE) standard. An average of 2,100 ED events are recorded, by 850 devices, on a monthly basis within Electric Power Board's distribution network. Due to operational restraints such as: time, money, and person power, only 2% of these recorded events are currently analyzed by power utility personnel. The remaining 98% of recorded events remain a significant loss in information, which could be vital in fully understanding the operating condition within the distribution network. This work presents a hierarchical automated classification process that assigns ED events into one of three “categories”: valid data, switching events, and faults/power quality (PQ) disturbances. This process correctly assigned 92.9% of the tested 140 COMTRADE files into one of these categories. In addition to this categorization, this work presents an automated approach for the classification of magnetic inrush events. A classification rate of 90.63% is demonstrated using 32 transformer inrush COMTRADE files.
- 3 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (2) , 1048-1057
On-Site Low Voltage Determination of Zero-Sequence Impedances for Power Transformers
Accurate zero-sequence transformer data is important for correct fault analysis and protection settings. Utilities have been forced to approximate zero-sequence impedances for many three-legged core power transformers in service today that did not undergo testing for zero-sequence data at the factory before site installation. Where approximation of the zero-sequence impedances from positive sequence data is of insufficient accuracy, on-site tests have been proposed. However, these usually involve measurements from the high-voltage windings, which are either expensive with high test voltages or do not offer sufficient current resolution with low test voltages. This paper proposes new methods for carrying out on-site zero-sequence testing entirely from the lowest voltage winding. Affordable equipment can then be used for the test with minimal switchyard test preparations. Two test configurations are described; a One-Open-Phase test and a Two-Open-Phase test. To validate the method, three typical transformer types are considered; a station auxiliary transformer (SAT), a generation step-up transformer (GSU), and a transmission transformer. The proposed method was tested on actual SAT and GSU units, and simulated for a transmission transformer. All test results validated the method and offered high accuracy.
- 3 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (2) , 1048-1057
On-Site Low Voltage Determination of Zero-Sequence Impedances for Power Transformers
Accurate zero-sequence transformer data is important for correct fault analysis and protection settings. Utilities have been forced to approximate zero-sequence impedances for many three-legged core power transformers in service today that did not undergo testing for zero-sequence data at the factory before site installation. Where approximation of the zero-sequence impedances from positive sequence data is of insufficient accuracy, on-site tests have been proposed. However, these usually involve measurements from the high-voltage windings, which are either expensive with high test voltages or do not offer sufficient current resolution with low test voltages. This paper proposes new methods for carrying out on-site zero-sequence testing entirely from the lowest voltage winding. Affordable equipment can then be used for the test with minimal switchyard test preparations. Two test configurations are described; a One-Open-Phase test and a Two-Open-Phase test. To validate the method, three typical transformer types are considered; a station auxiliary transformer (SAT), a generation step-up transformer (GSU), and a transmission transformer. The proposed method was tested on actual SAT and GSU units, and simulated for a transmission transformer. All test results validated the method and offered high accuracy.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Estimating the Effects of Small Voltage and Frequency Changes on Industrial Induction Motor Loading
This work develops expressions for estimating the change in active and reactive power for industrial motors in response to voltage and frequency variations around the operating point. Magnetizing circuit saturation is accounted for by using incremental reactance. The expressions are simplified for a quick estimate using stator measurements and parameters. The expressions are validated using simulation, and further, a test was carried out in a nuclear power plant to determine the voltage sensitivities experimentally. Both simulation and test show that the expressions are capable of yielding a fair estimation of the required sensitivities.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Estimating the Effects of Small Voltage and Frequency Changes on Industrial Induction Motor Loading
This work develops expressions for estimating the change in active and reactive power for industrial motors in response to voltage and frequency variations around the operating point. Magnetizing circuit saturation is accounted for by using incremental reactance. The expressions are simplified for a quick estimate using stator measurements and parameters. The expressions are validated using simulation, and further, a test was carried out in a nuclear power plant to determine the voltage sensitivities experimentally. Both simulation and test show that the expressions are capable of yielding a fair estimation of the required sensitivities.
- 3 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 33 (2) , 1231-1241
Development and Application of a New Voltage Stability Index for On-Line Monitoring and Shedding
Continuous assessment of voltage stability is vital to ensure a secure operation of the power system. Several voltage stability indicators have been developed in an attempt to quantify proximity to voltage collapse. Some of them are computationally expensive, while others are reported not to perform as expected under all conditions. This study proposes a new normalized voltage stability indicator called the P-index which is robust and based on solid theoretical foundations. The index was tested on the IEEE 14, 57 and 118-bus systems and compared to the well-established L-index node-based indicator. It was also shown how the P-index can be used to estimate the distance to collapse and the amount of load to be shed. A comparison of distance to collapse was made with the Coupled Single-Port Circuit and tangent vector methods. Application of the P-index to a dynamic platform simulating stability monitoring with PMU measurements was performed on the Kundur 10-bus system and the appropriate load shedding using the P-index was calculated. The results show that the P-index gives a better indication of proximity to voltage collapse compared to the L-indices and tangent vectors and is more conservative than the CSPC method. Results also indicate its potential for dynamic voltage stability assessment and load shedding purposes.
- 3 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 33 (2) , 1231-1241
Development and Application of a New Voltage Stability Index for On-Line Monitoring and Shedding
Continuous assessment of voltage stability is vital to ensure a secure operation of the power system. Several voltage stability indicators have been developed in an attempt to quantify proximity to voltage collapse. Some of them are computationally expensive, while others are reported not to perform as expected under all conditions. This study proposes a new normalized voltage stability indicator called the P-index which is robust and based on solid theoretical foundations. The index was tested on the IEEE 14, 57 and 118-bus systems and compared to the well-established L-index node-based indicator. It was also shown how the P-index can be used to estimate the distance to collapse and the amount of load to be shed. A comparison of distance to collapse was made with the Coupled Single-Port Circuit and tangent vector methods. Application of the P-index to a dynamic platform simulating stability monitoring with PMU measurements was performed on the Kundur 10-bus system and the appropriate load shedding using the P-index was calculated. The results show that the P-index gives a better indication of proximity to voltage collapse compared to the L-indices and tangent vectors and is more conservative than the CSPC method. Results also indicate its potential for dynamic voltage stability assessment and load shedding purposes.