Riaz Khan
Research Subjects
Riaz Khan has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Abdul Qayyum
National Tokamak Fusion Program, Islamabad, Pakistan
5 shared publications S. Hussain
5 shared publications- Naoki Mizuguchi
National Institute for Fusion Science
4 shared publications S. Ahmad
4 shared publicationsF. Deeba
3 shared publicationsN. Ahmed
National Tokamak Fusion Program, Islamabad 44000, Pakistan
3 shared publications
Latest Publications
- Open Access
- 16 June 2026
- Published by MDPI AG in Chemengineering
- Vol. 10 (6) , 77
Optimization and Process Modeling of Plasma Gasifier via Aspen Plus and Surrogate Model for Treatment of Municipal Solid Waste
Plasma gasification is a sustainable and advanced technology for the safe and efficient treatment of municipal solid waste (MSW). In this process, a plasma torch serves as the primary heating source to convert MSW into syngas and inert vitrified slag. The produced syngas can be used for various downstream applications, including power generation. In this study, an updraft plasma gasifier is modeled using the Aspen Plus process simulator, with municipal solid waste from Lahore, Pakistan, used as the feedstock. Air is selected as a plasma-forming gas due to its low cost and widespread availability. The primary aim of this research is to analyze the effect of specific torch power and the air-to-feed mass flow ratio on syngas molar composition, syngas higher heating value (HHV), and cold gas efficiency (CGE), and to maximize gasifier performance. CGE of the gasifier is optimized using a surrogate-based model integrated with a genetic algorithm (GA). An artificial neural network (ANN) is employed as the surrogate model for the optimization of CGE. The novelty of this work lies in two key aspects: firstly, this is among the first studies to specifically model and simulate plasma gasification of Lahore’s MSW, capturing its unique waste composition characteristics; and secondly, the integration of process simulation with a data-driven optimization framework using an ANN surrogate model. A total of 1521 data points were generated from the Aspen Plus simulation to train the ANN model and perform optimization in MATLAB. The optimized CGE was found to be 90.6%. Validation of the ANN-GA optimization was carried out by implementing the optimized input parameters in the Aspen Plus gasifier model. The resulting CGE shows a percent relative error of only 0.11% compared to the MATLAB-predicted value, confirming the accuracy of the surrogate model. Furthermore, comparison with the base case simulation reveals that the optimized operating conditions lead to an 8.6% increase in cold gas efficiency, demonstrating the effectiveness of the proposed optimization approach.
- 16 June 2026
- Published by MDPI AG in Chemengineering
- Vol. 10 (6) , 77
Open AccessOptimization and Process Modeling of Plasma Gasifier via Aspen Plus and Surrogate Model for Treatment of Municipal Solid Waste
Plasma gasification is a sustainable and advanced technology for the safe and efficient treatment of municipal solid waste (MSW). In this process, a plasma torch serves as the primary heating source to convert MSW into syngas and inert vitrified slag. The produced syngas can be used for various downstream applications, including power generation. In this study, an updraft plasma gasifier is modeled using the Aspen Plus process simulator, with municipal solid waste from Lahore, Pakistan, used as the feedstock. Air is selected as a plasma-forming gas due to its low cost and widespread availability. The primary aim of this research is to analyze the effect of specific torch power and the air-to-feed mass flow ratio on syngas molar composition, syngas higher heating value (HHV), and cold gas efficiency (CGE), and to maximize gasifier performance. CGE of the gasifier is optimized using a surrogate-based model integrated with a genetic algorithm (GA). An artificial neural network (ANN) is employed as the surrogate model for the optimization of CGE. The novelty of this work lies in two key aspects: firstly, this is among the first studies to specifically model and simulate plasma gasification of Lahore’s MSW, capturing its unique waste composition characteristics; and secondly, the integration of process simulation with a data-driven optimization framework using an ANN surrogate model. A total of 1521 data points were generated from the Aspen Plus simulation to train the ANN model and perform optimization in MATLAB. The optimized CGE was found to be 90.6%. Validation of the ANN-GA optimization was carried out by implementing the optimized input parameters in the Aspen Plus gasifier model. The resulting CGE shows a percent relative error of only 0.11% compared to the MATLAB-predicted value, confirming the accuracy of the surrogate model. Furthermore, comparison with the base case simulation reveals that the optimized operating conditions lead to an 8.6% increase in cold gas efficiency, demonstrating the effectiveness of the proposed optimization approach.
- 1 November 2025
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 17 (6)
Design and implementation of a 10 kV/2 A LLC resonant converter with two-step soft-start PID control for industrial magnetron
This paper presents the design and implementation of a high-voltage direct current (HVDC) power supply rated for 10 kV, 2 A (20 kW), developed to drive a 10 kW, 2.45 GHz industrial magnetron requiring approximately 8.8 kV, 1.6–1.8 A (16 kW input) under nominal operation. Accordingly, the HVDC supply was rated at 20 kW to allow margin for surges, efficiency variation, and future scaling. The converter core employs a full-bridge inductor-inductor-capacitor (LLC) resonant topology operating at a nominal switching frequency of 22 kHz, chosen for its high power density, inherent soft switching, and effective use of transformer leakage inductance in the resonant tank. A two-step soft-start sequence is implemented: the output first stabilizes at 6.8 kV in standby before smoothly rising to 8.8 kV for full-power operation, with a transition time below 200 ms and no overshoot. Closed-loop regulation is achieved through digital proportional–integral–derivative (PID) control on a Texas Instruments TMS320F280025C using pulses-frequency modulation (PFM). The prototype demonstrates stable voltage regulation with low output ripple (<1%) while maintaining zero-voltage and zero-current switching (ZVS/ZCS) across the operating range. All high-voltage magnetic components, including the resonant inductor and custom 20 kVA transformer, were designed and built in-house to meet insulation and power-density requirements. Experimental validation confirms reliable startup, arc-free operation, and efficient power conversion under variable load conditions. In summary, the proposed digitally controlled LLC converter delivers a regulated 10 kV/2 A direct current (DC) output with controlled soft start, offering a compact, low-cost, and robust solution for industrial magnetron and plasma heating applications.
- 1 November 2025
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 17 (6)
Design and implementation of a 10 kV/2 A LLC resonant converter with two-step soft-start PID control for industrial magnetron
This paper presents the design and implementation of a high-voltage direct current (HVDC) power supply rated for 10 kV, 2 A (20 kW), developed to drive a 10 kW, 2.45 GHz industrial magnetron requiring approximately 8.8 kV, 1.6–1.8 A (16 kW input) under nominal operation. Accordingly, the HVDC supply was rated at 20 kW to allow margin for surges, efficiency variation, and future scaling. The converter core employs a full-bridge inductor-inductor-capacitor (LLC) resonant topology operating at a nominal switching frequency of 22 kHz, chosen for its high power density, inherent soft switching, and effective use of transformer leakage inductance in the resonant tank. A two-step soft-start sequence is implemented: the output first stabilizes at 6.8 kV in standby before smoothly rising to 8.8 kV for full-power operation, with a transition time below 200 ms and no overshoot. Closed-loop regulation is achieved through digital proportional–integral–derivative (PID) control on a Texas Instruments TMS320F280025C using pulses-frequency modulation (PFM). The prototype demonstrates stable voltage regulation with low output ripple (<1%) while maintaining zero-voltage and zero-current switching (ZVS/ZCS) across the operating range. All high-voltage magnetic components, including the resonant inductor and custom 20 kVA transformer, were designed and built in-house to meet insulation and power-density requirements. Experimental validation confirms reliable startup, arc-free operation, and efficient power conversion under variable load conditions. In summary, the proposed digitally controlled LLC converter delivers a regulated 10 kV/2 A direct current (DC) output with controlled soft start, offering a compact, low-cost, and robust solution for industrial magnetron and plasma heating applications.
- 9 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (6) , 2021-2028
Cost-Effective Microwave Assisted ECR Heating Using Combination of Quasi-Locked Low-Power Magnetrons on GLAST-III
Glass spherical tokamak-III (GLAST-III) is a small spherical tokamak ( $R$ $=$ 20 cm, $a$ $=$ 10 cm, and $A$ $=$ 2) developed at Pakistan Tokamak Plasma Research Institute (PTPRI). To assist the plasma discharge and generate considerable plasma current in GLAST-III, high-power microwave sources can indeed play an important role in noninductive startups of plasma discharges such as electron cyclotron resonance heating (ECRH). A power-enhanced pulsed microwave source (2.45 GHz and 1.6 kW) has previously been developed and tested at PTPRI. However, higher powers are required to increase the generated charge density for effective pre-ionization. Therefore, a microwave pre-ionization source (up to 20 kW at 2.45 GHz) is installed on GLAST-III to reduce the high-loop voltage requirement during the plasma start-up. ECRH has been effectively utilized for this purpose. In this article, an economical high-power microwave source is fabricated by coupling low-power magnetrons in a waveguide. We employed Walton multiplier circuits for the first time to operate two magnetrons coupled for power addition. The coupling of two magnetrons due to constructive interference is demonstrated successfully during continuous as well as pulsed operation. The scheme can be made more effective in future studies by injection locking of magnetrons. These innovative low-cost schemes can play a pivotal role in carrying out microwave studies on spherical tokamaks such as GLAST-III.
- 9 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (6) , 2021-2028
Cost-Effective Microwave Assisted ECR Heating Using Combination of Quasi-Locked Low-Power Magnetrons on GLAST-III
Glass spherical tokamak-III (GLAST-III) is a small spherical tokamak ( $R$ $=$ 20 cm, $a$ $=$ 10 cm, and $A$ $=$ 2) developed at Pakistan Tokamak Plasma Research Institute (PTPRI). To assist the plasma discharge and generate considerable plasma current in GLAST-III, high-power microwave sources can indeed play an important role in noninductive startups of plasma discharges such as electron cyclotron resonance heating (ECRH). A power-enhanced pulsed microwave source (2.45 GHz and 1.6 kW) has previously been developed and tested at PTPRI. However, higher powers are required to increase the generated charge density for effective pre-ionization. Therefore, a microwave pre-ionization source (up to 20 kW at 2.45 GHz) is installed on GLAST-III to reduce the high-loop voltage requirement during the plasma start-up. ECRH has been effectively utilized for this purpose. In this article, an economical high-power microwave source is fabricated by coupling low-power magnetrons in a waveguide. We employed Walton multiplier circuits for the first time to operate two magnetrons coupled for power addition. The coupling of two magnetrons due to constructive interference is demonstrated successfully during continuous as well as pulsed operation. The scheme can be made more effective in future studies by injection locking of magnetrons. These innovative low-cost schemes can play a pivotal role in carrying out microwave studies on spherical tokamaks such as GLAST-III.
- 19 August 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 207
Design and development of FPGA based trigger system for automation of metallic tokamak (MT-I)
- 19 August 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 207
Design and development of FPGA based trigger system for automation of metallic tokamak (MT-I)
- 27 May 2022
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 47 (51) , 21794-21802
Time-resolved probe measurements and sequential imaging of the pre-ionized hydrogen plasma zones in GLAST-III tokamak
- 27 May 2022
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 47 (51) , 21794-21802
Time-resolved probe measurements and sequential imaging of the pre-ionized hydrogen plasma zones in GLAST-III tokamak
- Open Access
Theoretical–Computational Study of Atmospheric DBD Plasma and Its Utility for Nanoscale Biocompatible Plasmonic Coating
In this study, time-dependent, one-dimensional modeling of a surface dielectric barrier discharge (SDBD) device, driven by a sinusoidal voltage of amplitude 1–3 kV at 20 kHz, in argon is described. An SDBD device with two Cu-stripe electrodes, covered by the quartz dielectric and with the discharge gap of 20 × 10−3 m, was assumed, and the time-dependent, one-dimensional discharge parameters were simulated versus time across the plasma gap. The plasma device simulated in the given arrangement was constructed and used for biocompatible antibacterial/antimicrobial coating of plasmonic particle aerosol and compared with the coating strategy of the DBD plasma jet. Simulation results showed discharge consists of an electrical breakdown, occurring in each half-cycle of the AC voltage with an electron density of 1.4 × 1010 cm−3 and electric field strength of 4.5 × 105 Vm−1. With SDBD, the surface coating comprises spatially distributed particles of mean size 29 (11) nm, while with argon plasma jet, the nanoparticles are aggregated in clusters that are three times larger in size. Both coatings are crystalline and exhibit plasmonic features in the visible spectral region. It is expected that the particle aerosols are collected under the ionic wind, induced by the plasma electric fields, and it is assumed that this follows the dominant charging mechanisms of ions diffusion. The cold plasma strategy is appealing in a sense; it opens new venues at the nanoscale to deal with biomedical and surgical devices in a flexible processing environment.
Open AccessTheoretical–Computational Study of Atmospheric DBD Plasma and Its Utility for Nanoscale Biocompatible Plasmonic Coating
In this study, time-dependent, one-dimensional modeling of a surface dielectric barrier discharge (SDBD) device, driven by a sinusoidal voltage of amplitude 1–3 kV at 20 kHz, in argon is described. An SDBD device with two Cu-stripe electrodes, covered by the quartz dielectric and with the discharge gap of 20 × 10−3 m, was assumed, and the time-dependent, one-dimensional discharge parameters were simulated versus time across the plasma gap. The plasma device simulated in the given arrangement was constructed and used for biocompatible antibacterial/antimicrobial coating of plasmonic particle aerosol and compared with the coating strategy of the DBD plasma jet. Simulation results showed discharge consists of an electrical breakdown, occurring in each half-cycle of the AC voltage with an electron density of 1.4 × 1010 cm−3 and electric field strength of 4.5 × 105 Vm−1. With SDBD, the surface coating comprises spatially distributed particles of mean size 29 (11) nm, while with argon plasma jet, the nanoparticles are aggregated in clusters that are three times larger in size. Both coatings are crystalline and exhibit plasmonic features in the visible spectral region. It is expected that the particle aerosols are collected under the ionic wind, induced by the plasma electric fields, and it is assumed that this follows the dominant charging mechanisms of ions diffusion. The cold plasma strategy is appealing in a sense; it opens new venues at the nanoscale to deal with biomedical and surgical devices in a flexible processing environment.
- Open Access
- 1 January 2020
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 13 (1) , 309-317
Impurity transport and halo current effects on tungsten divertor system
This paper presents the development of theoretical model for the purpose to calculate and analyze halo and eddy current effects in the tungsten divertor of Tokamak (Fusion) reactor. In the first step, focal points for plasma energy, sideways forces (on the vessel), impurities, and halo–eddy current effects (in terms of poloidal and toroidal magnetic field orientations) were calculated. During the verge of point calculation, the research was extended to calculate the initial conducting point (halo current) for the tungsten divertor plate. Three cases were considered for investigating the plasma energy during upward and downward flows to the divertor plate. Poloidal and toroidal orientation of plasma energy were investigated and the theoretical model was developed. Initial conducting point with respect to (r,z) was calculated for halo current calculations and its derivatives. A mechanism for the development of the asymmetry and for estimating electromechanical loads was performed. For computational analysis, a Matlab program was developed to calculate and verify halo current and plasma energy calculation points. The main objective of the research is to develop a theoretical-computational model to evaluate plasma behavior and divertor system in any Tokamak reactor.
- 1 January 2020
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 13 (1) , 309-317
Open AccessImpurity transport and halo current effects on tungsten divertor system
This paper presents the development of theoretical model for the purpose to calculate and analyze halo and eddy current effects in the tungsten divertor of Tokamak (Fusion) reactor. In the first step, focal points for plasma energy, sideways forces (on the vessel), impurities, and halo–eddy current effects (in terms of poloidal and toroidal magnetic field orientations) were calculated. During the verge of point calculation, the research was extended to calculate the initial conducting point (halo current) for the tungsten divertor plate. Three cases were considered for investigating the plasma energy during upward and downward flows to the divertor plate. Poloidal and toroidal orientation of plasma energy were investigated and the theoretical model was developed. Initial conducting point with respect to (r,z) was calculated for halo current calculations and its derivatives. A mechanism for the development of the asymmetry and for estimating electromechanical loads was performed. For computational analysis, a Matlab program was developed to calculate and verify halo current and plasma energy calculation points. The main objective of the research is to develop a theoretical-computational model to evaluate plasma behavior and divertor system in any Tokamak reactor.
- 5 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (10) , 4729-4737
Start-Up Studies of GLAST-III Spherical Tokamak in the Presence of Poloidal Field
GLAST-III (glass spherical tokamak) is a small device having an aspect ratio of two (R/a= 2) with major radius R= 20 cm and minor radius a = 10 cm. Experiments are performed to examine the effect of increasing the poloidal field (PF) produced by poloidal coils as well as to study the effect of the inductance of PF coils on the plasma current formation. To investigate the GLAST-III plasma, several diagnostic tools such as Rogowski coil, loop voltage, photodiode, Optical emission spectroscopy, high-speed camera, and Langmuir probe are used. After optimizing the working pressure, the first experiment is performed using toroidal field coils and central solenoid along with radio frequency (RF) pre-ionization source. A plasma current of 1 kA is achieved for 1.2 ms. In later experiments, the effect of the poloidal magnetic field is also included. It is observed that with increasing the PF, the plasma current increases, attain a maximum value (5 kA) and then after a critical value of the applied poloidal magnetic field, the plasma current starts decreasing. Similarly, with the inclusion of inductor in series with the PF coils, the plasma current value is reduced and its pulse duration is increased. Both optical emission and Langmuir probe diagnostics results show a similar trend of the plasma current.
- 5 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (10) , 4729-4737
Start-Up Studies of GLAST-III Spherical Tokamak in the Presence of Poloidal Field
GLAST-III (glass spherical tokamak) is a small device having an aspect ratio of two (R/a= 2) with major radius R= 20 cm and minor radius a = 10 cm. Experiments are performed to examine the effect of increasing the poloidal field (PF) produced by poloidal coils as well as to study the effect of the inductance of PF coils on the plasma current formation. To investigate the GLAST-III plasma, several diagnostic tools such as Rogowski coil, loop voltage, photodiode, Optical emission spectroscopy, high-speed camera, and Langmuir probe are used. After optimizing the working pressure, the first experiment is performed using toroidal field coils and central solenoid along with radio frequency (RF) pre-ionization source. A plasma current of 1 kA is achieved for 1.2 ms. In later experiments, the effect of the poloidal magnetic field is also included. It is observed that with increasing the PF, the plasma current increases, attain a maximum value (5 kA) and then after a critical value of the applied poloidal magnetic field, the plasma current starts decreasing. Similarly, with the inclusion of inductor in series with the PF coils, the plasma current value is reduced and its pulse duration is increased. Both optical emission and Langmuir probe diagnostics results show a similar trend of the plasma current.
- 6 June 2019
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 33 (16)
Development and verification of numerical study to calculate focal points of temperature in helium cooled ceramic blanket (HCCB) system in CFETR
In this paper, a novel theoretical model has been developed to obtain focal points of temperatures in helium cooled ceramic breeder (HCCB) blanket system of China Fusion Engineering Test Reactor (CFETR). The main objective of the paper is to develop a theoretical-computational model for safety of blanket system, structure stress analysis and feasibility design. The theoretical-computational model was developed and verified by computational techniques using C++/MATLAB program and later with thermo-hydraulic system codes, i.e. RELAP5 and THEATRE. Mathematical model was developed for the thermal conductivity in HCCB blanket system and heat conduction model by using numerical technique. This model was then transferred to C++/MATLAB program and developed a program for calculating the thermal contact temperature of HCCB region. The calculated temperature values were then compared with RELAP5 and THEATRE codes for the accuracy of theoretical model. The preliminary thermal-hydraulic simulation results indicate that the maximum temperature on the first wall (FW) satisfies the design allowable limit and that the cooling channels were designed accurately. The results obtained from these analyses are very close to the experimentally defined values depicting the accuracy of theoretical and simulation results. The calculated results can be applicable to other tokamak devices like CFETR, ITER and JET as well.
- 6 June 2019
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 33 (16)
Development and verification of numerical study to calculate focal points of temperature in helium cooled ceramic blanket (HCCB) system in CFETR
In this paper, a novel theoretical model has been developed to obtain focal points of temperatures in helium cooled ceramic breeder (HCCB) blanket system of China Fusion Engineering Test Reactor (CFETR). The main objective of the paper is to develop a theoretical-computational model for safety of blanket system, structure stress analysis and feasibility design. The theoretical-computational model was developed and verified by computational techniques using C++/MATLAB program and later with thermo-hydraulic system codes, i.e. RELAP5 and THEATRE. Mathematical model was developed for the thermal conductivity in HCCB blanket system and heat conduction model by using numerical technique. This model was then transferred to C++/MATLAB program and developed a program for calculating the thermal contact temperature of HCCB region. The calculated temperature values were then compared with RELAP5 and THEATRE codes for the accuracy of theoretical model. The preliminary thermal-hydraulic simulation results indicate that the maximum temperature on the first wall (FW) satisfies the design allowable limit and that the cooling channels were designed accurately. The results obtained from these analyses are very close to the experimentally defined values depicting the accuracy of theoretical and simulation results. The calculated results can be applicable to other tokamak devices like CFETR, ITER and JET as well.
- 14 September 2018
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 37 (6) , 308-316
Steady State and Transient Analysis of Novel Design Helium Cooled Ceramic Blanket (HCCB) System of China Fusion Engineering Test Reactor (CFETR)
- 14 September 2018
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 37 (6) , 308-316
Steady State and Transient Analysis of Novel Design Helium Cooled Ceramic Blanket (HCCB) System of China Fusion Engineering Test Reactor (CFETR)