MMMarie-Astrid Metten

Marie-Astrid Metten

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marie-Astrid Metten has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Cécile Zaros

    French Institute for Demographic Studies (Ined), French Institute for Medical Research and Health (Inserm), French Blood Agency, ELFE Joint Unit, F-75020, Paris, France

    2 shared publications
  • A. Collin

    From the Departments of Radiology (A.G.P., A.C., L.D., J.C.S., J.S., A.L.).

    1 shared publication
  • Alexandre Nougadère

    European Food Safety Authority (EFSA), Scientific Committee and Emerging Risks Unit (SCER), Parma, Italy

    1 shared publication
  • Antoine Gueguen

    Paris University Hospital, Fondation Rothschild, Paris, France

    1 shared publication
  • Athena Galletto Pregliasco

    Medical Imaging Department, Henri Mondor University Hospital Assistance Publique-Hôpitaux de Paris, 51 Avenue du Maréchal de Lattre de Tassigny, 94010 Créteil, France

    1 shared publication
  • Augustin Lecler

    Department of Neuroradiology, Hôpital Fondation Adolphe de Rothschild, 75019 Paris, France; Université Paris Cité, Faculté de Médecine, 75006 Paris, France

    1 shared publication

Latest Publications

  • Maternal occupational exposure to organic solvents and intrauterine growth in the ELFE cohort

    by Isabelle Enderle, Virginie De Lauzun, Marie Astrid Metten, Marion Monperrus, Fleur Delva, Pauline Blanc-Petitjean, Brigitte Dananche, Christophe Paris, Cécile Zaros, Maela Le Lous, et al.


  • Open Access

    Reflection on modern methods: a note on variance estimation when using inverse probability weighting to handle attrition in cohort studies

    by Marie-Astrid Metten, Nathalie Costet, J. -F. Viel, Guillaume Chauvet

    The inverse probability weighting (IPW) method is used to handle attrition in association analyses derived from cohort studies. It consists in weighting the respondents at a given follow-up by their inverse probability to participate. Weights are estimated first and then used in a weighted association model. When the IPW method is used, instead of using a so-called na{\"i}ve variance estimator, the literature recommends using a robust variance estimator. However, the latter may overestimate the variance because the weights are considered known rather than estimated. In this note, we develop, by a linearization technique, an estimator accounting for the weight estimation phase and explain how it differs from na{\"i}ve and robust variance estimators. We compare the three variance estimators through simulations under several MAR and MNAR scenarios. We found that both the robust and linearized variance estimators were approximately unbiased, even in MNAR scenarios. The naive variance estimator severely underestimated the variance. We encourage researchers to be careful with variance estimation when using the IPW method, avoiding na{\"i}ve estimator and opting for a robust or linearized estimator. R and SAS codes are provided to implement them in their own studies.

  • Multiple pesticide analysis in hair samples of pregnant French women: Results from the ELFE national birth cohort

    by Rémi Béranger, Emilie M. Hardy, Célia Dexet, Laurence Guldner, Cécile Zaros, Alexandre Nougadère, Marie-Astrid Metten, Cécile Chevrier, Brice M.R. Appenzeller


  • Open Access

    Improved Detection of New MS Lesions during Follow-Up Using an Automated MR Coregistration-Fusion Method

    by A. Galletto Pregliasco, A. Collin, A. Guéguen, M.A. Metten, J. Aboab, R. Deschamps, O. Gout, L. Duron, J.C. Sadik, J. Savatovsky, et al.

    BACKGROUND AND PURPOSE: MR imaging is the key examination in the follow-up of patients with MS, by identification of new high-signal T2 brain lesions. However, identifying new lesions when scrolling through 2 follow-up MR images can be difficult and time-consuming. Our aim was to compare an automated coregistration-fusion reading approach with the standard approach by identifying new high-signal T2 brain lesions in patients with multiple sclerosis during follow-up MR imaging. MATERIALS AND METHODS: This prospective monocenter study included 94 patients (mean age, 38.9 years) treated for MS with dimethyl fumarate from January 2014 to August 2016. One senior neuroradiologist and 1 junior radiologist checked for new high-signal T2 brain lesions, independently analyzing blinded image datasets with automated coregistration-fusion or the standard scroll-through approach with a 3-week delay between the 2 readings. A consensus reading with a second senior neuroradiologist served as a criterion standard for analyses. A Poisson regression and logistic and γ regressions were used to compare the 2 methods. Intra- and interobserver agreement was assessed by the κ coefficient. RESULTS: There were significantly more new high-signal T2 lesions per patient detected with the coregistration-fusion method (7 versus 4, P < .001). The coregistration-fusion method detected significantly more patients with at least 1 new high-signal T2 lesion (59% versus 46%, P = .02) and was associated with significantly faster overall reading time (86 seconds faster, P < .001) and higher reader confidence (91% versus 40%, P < 1 × 10−4). Inter- and intraobserver agreement was excellent for counting new high-signal T2 lesions. CONCLUSIONS: Our study showed that an automated coregistration-fusion method was more sensitive for detecting new high-signal T2 lesions in patients with MS and reducing reading time. This method could help to improve follow-up care.