Improved Detection of New MS Lesions during Follow-Up Using an Automated MR Coregistration-Fusion Method
Open Access
- 7 June 2018
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (7) , 1226-1232
Abstract
BACKGROUND AND PURPOSE: MR imaging is the key examination in the follow-up of patients with MS, by identification of new high-signal T2 brain lesions. However, identifying new lesions when scrolling through 2 follow-up MR images can be difficult and time-consuming. Our aim was to compare an automated coregistration-fusion reading approach with the standard approach by identifying new high-signal T2 brain lesions in patients with multiple sclerosis during follow-up MR imaging. MATERIALS AND METHODS: This prospective monocenter study included 94 patients (mean age, 38.9 years) treated for MS with dimethyl fumarate from January 2014 to August 2016. One senior neuroradiologist and 1 junior radiologist checked for new high-signal T2 brain lesions, independently analyzing blinded image datasets with automated coregistration-fusion or the standard scroll-through approach with a 3-week delay between the 2 readings. A consensus reading with a second senior neuroradiologist served as a criterion standard for analyses. A Poisson regression and logistic and γ regressions were used to compare the 2 methods. Intra- and interobserver agreement was assessed by the κ coefficient. RESULTS: There were significantly more new high-signal T2 lesions per patient detected with the coregistration-fusion method (7 versus 4, P < .001). The coregistration-fusion method detected significantly more patients with at least 1 new high-signal T2 lesion (59% versus 46%, P = .02) and was associated with significantly faster overall reading time (86 seconds faster, P < .001) and higher reader confidence (91% versus 40%, P < 1 × 10−4). Inter- and intraobserver agreement was excellent for counting new high-signal T2 lesions. CONCLUSIONS: Our study showed that an automated coregistration-fusion method was more sensitive for detecting new high-signal T2 lesions in patients with MS and reducing reading time. This method could help to improve follow-up care.Keywords
This publication has 33 references indexed in Scilit:
- Recommendations to improve imaging and analysis of brain lesion load and atrophy in longitudinal studies of multiple sclerosisJournal of Neurology, 2012
- Scoring treatment response in patients with relapsing multiple sclerosisMultiple Sclerosis Journal, 2012
- MRI monitoring of immunomodulation in relapse-onset multiple sclerosis trialsNature Reviews Neurology, 2011
- Diagnostic criteria for multiple sclerosis: 2010 Revisions to the McDonald criteriaAnnals of Neurology, 2011
- Subtraction MR Images in a Multiple Sclerosis Multicenter Clinical Trial SettingRadiology, 2009
- The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Statement: Guidelines for Reporting Observational StudiesAnnals of Internal Medicine, 2007
- Serial Isotropic Three-Dimensional Fast FLAIR Imaging: Using Image Registration and Subtraction to Reveal Active Multiple Sclerosis LesionsAmerican Journal of Roentgenology, 2002
- Image registration and subtraction to detect active T 2 lesions in MS: an interobserver studyJournal of Neurology, 2002
- Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology.Psychological Assessment, 1994
- Rating neurologic impairment in multiple sclerosisNeurology, 1983