Yushi Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yushi Yang has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Eldwin Jiaqiang Ng
Stanford University, Stanford, USA
7 shared publications Thomas W. Kenny
Mechanical Engineering Department, Stanford University, Stanford, CA, USA
5 shared publications- David. A. Horsley
University of California, Davis, USA
3 shared publications - Ian B. Flader
Apple Inc., Cupertino, CA, USA
3 shared publications Chae H. Ahn
Department of Mechanical Engineering, Stanford, CA, USA
2 shared publicationsEldwin J. Ng
Inst Microelect, Singapore 117685, Singapore
2 shared publications
Latest Publications
- 12 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 28 (3) , 372-381
Micro-Tethering for Fabrication of Encapsulated Inertial Sensors With High Sensitivity
- 12 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 28 (3) , 372-381
Micro-Tethering for Fabrication of Encapsulated Inertial Sensors With High Sensitivity
- Open Access
- 15 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 25 (5) , 859-869
Nonlinearity of Degenerately Doped Bulk-Mode Silicon MEMS Resonators
We present an experimental study of conservative nonlinearities in bulk acoustic mode (bulk-mode) silicon MEMS resonators with degenerate doping. Three types of bulk acoustic mode resonators oriented in (110) and (100) silicon crystalline directions are used to analyze both linear and nonlinear elastic behavior of silicon with p- (N ≅ 4.19e + 18 to 1.63e + 20 cm -3 ) and n-type (N ≅ 1.58e + 18 to 5.91e + 19 cm -3 ) doping. For accurate characterization of the amplitude-dependent nonlinear stiffness constant, we employ two methods: amplitude-frequency response and ringdown measurement. Experimental results show that the nonlinear behavior of these resonators is dominated by material-dependent mechanical nonlinearities and strongly depends on the doping type and crystal orientation. These results are useful for understanding the material-induced nonlinear properties of doped silicon and design of MEMS resonators with desired dynamic behavior, and may provide a new avenue for tailoring resonator response characteristics.
- 15 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 25 (5) , 859-869
Open AccessNonlinearity of Degenerately Doped Bulk-Mode Silicon MEMS Resonators
We present an experimental study of conservative nonlinearities in bulk acoustic mode (bulk-mode) silicon MEMS resonators with degenerate doping. Three types of bulk acoustic mode resonators oriented in (110) and (100) silicon crystalline directions are used to analyze both linear and nonlinear elastic behavior of silicon with p- (N ≅ 4.19e + 18 to 1.63e + 20 cm -3 ) and n-type (N ≅ 1.58e + 18 to 5.91e + 19 cm -3 ) doping. For accurate characterization of the amplitude-dependent nonlinear stiffness constant, we employ two methods: amplitude-frequency response and ringdown measurement. Experimental results show that the nonlinear behavior of these resonators is dominated by material-dependent mechanical nonlinearities and strongly depends on the doping type and crystal orientation. These results are useful for understanding the material-induced nonlinear properties of doped silicon and design of MEMS resonators with desired dynamic behavior, and may provide a new avenue for tailoring resonator response characteristics.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 994-997
Q-factor optimization in disk resonator gyroscopes via geometric parameterization
We present an assortment of geometrically parameterized disk resonator gyroscopes (DRGs) individually designed for resonant frequency (f) and quality factor (Q). This work demonstrates accurate FEM-based predictions of Q for fabricated devices, and geometric optimizations that significantly improve this key performance metric for the DRG. Measurements on suites of fabricated devices confirm that losses are dominated by thermoelastic dissipation (TED). Qted is shown to account for 64-80% of the total energy dissipation. The temperature dependence of Q is also used to confirm and quantify the presence of pressure damping in the fabricated devices. At frequencies near 300 kHz, we show that Q can be increased by a factor of 2.6 and demonstrate feasibility of geometric/topological optimization of the fabricated devices with the aid of finite element software.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 994-997
Q-factor optimization in disk resonator gyroscopes via geometric parameterization
We present an assortment of geometrically parameterized disk resonator gyroscopes (DRGs) individually designed for resonant frequency (f) and quality factor (Q). This work demonstrates accurate FEM-based predictions of Q for fabricated devices, and geometric optimizations that significantly improve this key performance metric for the DRG. Measurements on suites of fabricated devices confirm that losses are dominated by thermoelastic dissipation (TED). Qted is shown to account for 64-80% of the total energy dissipation. The temperature dependence of Q is also used to confirm and quantify the presence of pressure damping in the fabricated devices. At frequencies near 300 kHz, we show that Q can be increased by a factor of 2.6 and demonstrate feasibility of geometric/topological optimization of the fabricated devices with the aid of finite element software.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 966-969
Epitaxially-encapsulated quad mass gyroscope with nonlinearity compensation
We present an epitaxially-encapsulated 2×2 mm 2 quad-mass gyroscope (QMG). Relative to the earlier QMG which measured 8×8 mm 2 and required an external vacuum package and getter [1], this device is 16x smaller in area and is vacuum-sealed at the wafer-level. Due to the device's small size, high quality factor (Q) and large oscillation amplitude are required to achieve low noise. However, the device's high Q (85,000) makes it highly sensitive to mechanical nonlinearity, resulting in amplitude-frequency dependence and instability of the oscillator loop at large amplitudes. To overcome these problems, we demonstrate electrostatic compensation of the mechanical nonlinearity, enabling 10x greater amplitude and therefore scale factor (SF). Together with closed-loop amplitude control and quadrature compensation, this enables angle-random walk of 0.42 mdeg/s/VHz, comparable to the best QMG published to date. Closed-loop amplitude control and quadrature null are used to achieve a bias instability of 1.6 deg/hr.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 966-969
Epitaxially-encapsulated quad mass gyroscope with nonlinearity compensation
We present an epitaxially-encapsulated 2×2 mm 2 quad-mass gyroscope (QMG). Relative to the earlier QMG which measured 8×8 mm 2 and required an external vacuum package and getter [1], this device is 16x smaller in area and is vacuum-sealed at the wafer-level. Due to the device's small size, high quality factor (Q) and large oscillation amplitude are required to achieve low noise. However, the device's high Q (85,000) makes it highly sensitive to mechanical nonlinearity, resulting in amplitude-frequency dependence and instability of the oscillator loop at large amplitudes. To overcome these problems, we demonstrate electrostatic compensation of the mechanical nonlinearity, enabling 10x greater amplitude and therefore scale factor (SF). Together with closed-loop amplitude control and quadrature compensation, this enables angle-random walk of 0.42 mdeg/s/VHz, comparable to the best QMG published to date. Closed-loop amplitude control and quadrature null are used to achieve a bias instability of 1.6 deg/hr.
- Open Access
- 15 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 24 (4) , 810-821
Multifunctional Integrated Sensors for Multiparameter Monitoring Applications
We present multifunctional integrated sensors (MFISES) that combine temperature, humidity, pressure, air speed, chemical gas, magnetic, and acceleration sensing on a single 2-mm × 2-mm die. We fabricate the MFISES in a wafer scale encapsulation process to hermetically seal the sensor functions with moving parts at low vacuum, and then surface micromachine the environmental sensors on top of the sealed layer. The encapsulation process provides very stable conditions for the pressure, magnetic, and acceleration sensors, and enables the deployment of the MFISES in dynamic environmental conditions without special postprocess packaging. We quantify the performance requirements for sensor applications in weather stations, indoor climate control, road activity monitoring, chemical sensing, and parking monitoring. We compare the performance of the MFISES to the application requirements to demonstrate the utility of an integrated sensor in a wide range of applications.
- 15 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 24 (4) , 810-821
Open AccessMultifunctional Integrated Sensors for Multiparameter Monitoring Applications
We present multifunctional integrated sensors (MFISES) that combine temperature, humidity, pressure, air speed, chemical gas, magnetic, and acceleration sensing on a single 2-mm × 2-mm die. We fabricate the MFISES in a wafer scale encapsulation process to hermetically seal the sensor functions with moving parts at low vacuum, and then surface micromachine the environmental sensors on top of the sealed layer. The encapsulation process provides very stable conditions for the pressure, magnetic, and acceleration sensors, and enables the deployment of the MFISES in dynamic environmental conditions without special postprocess packaging. We quantify the performance requirements for sensor applications in weather stations, indoor climate control, road activity monitoring, chemical sensing, and parking monitoring. We compare the performance of the MFISES to the application requirements to demonstrate the utility of an integrated sensor in a wide range of applications.
- Open Access
- 30 May 2014
- Published by Transducer Research Foundation Inc. (TRF)
- p. 99-100
AN ETCH HOLE-FREE PROCESS FOR TEMPERATURE-COMPENSATED, HIGH Q, ENCAPSULATED RESONATORS
- 30 May 2014
- Published by Transducer Research Foundation Inc. (TRF)
- p. 99-100
Open AccessAN ETCH HOLE-FREE PROCESS FOR TEMPERATURE-COMPENSATED, HIGH Q, ENCAPSULATED RESONATORS
- 1 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10846999,p. 80-83
Single-structure 3-axis lorentz force magnetometer with sub-30 nT/√HZ resolution
This work demonstrates a 3-axis Lorentz force magnetometer for electronic compass purposes. The magnetometer measures magnetic flux in 3 axes using a single structure. With 1 mW power consumption, the sensor achieves sub-30 nT/√Hz resolution in each of the 3 axes. Compared to the 3-axis Hall sensors currently used in smartphones, the 3-axis magnetometer shown here has the advantages of 10× lower noise floor and the ability to be co-fabricated with MEMS inertial sensors.
- 1 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10846999,p. 80-83
Single-structure 3-axis lorentz force magnetometer with sub-30 nT/√HZ resolution
This work demonstrates a 3-axis Lorentz force magnetometer for electronic compass purposes. The magnetometer measures magnetic flux in 3 axes using a single structure. With 1 mW power consumption, the sensor achieves sub-30 nT/√Hz resolution in each of the 3 axes. Compared to the 3-axis Hall sensors currently used in smartphones, the 3-axis magnetometer shown here has the advantages of 10× lower noise floor and the ability to be co-fabricated with MEMS inertial sensors.
- 1 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10846999,p. 749-752
Impact of gyroscope operation above the critical bifurcation threshold on scale factor and bias instability
This paper investigates the impact of operating a vibratory rate gyro (VRG) at large oscillation amplitude where the VRG's driven axis behaves like a nonlinear oscillator, described by the Duffing equation. Although open-loop resonators operating above a critical amplitude exhibit catastrophic jump instabilities, we demonstrate that through closed-loop operation, the drive axis can be stably operated at an amplitude above this threshold without impacting drive-axis stability or bias instability, resulting in decreased Angle Random Walk (ARW).
- 1 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10846999,p. 749-752
Impact of gyroscope operation above the critical bifurcation threshold on scale factor and bias instability
This paper investigates the impact of operating a vibratory rate gyro (VRG) at large oscillation amplitude where the VRG's driven axis behaves like a nonlinear oscillator, described by the Duffing equation. Although open-loop resonators operating above a critical amplitude exhibit catastrophic jump instabilities, we demonstrate that through closed-loop operation, the drive axis can be stably operated at an amplitude above this threshold without impacting drive-axis stability or bias instability, resulting in decreased Angle Random Walk (ARW).
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2159547X,p. 1723-1726
Geometric compensation of (100) single crystal silicon disk resonating gyroscope for mode-matching
In this paper, we show two methods for modifying the design of a Disk Resonating Gyroscope (DRG) to compensate for the mechanical anisotropy in single crystal silicon. This method is validated through experimental characterization of more than 70 different devices. With the proposed methods, the frequency split of the 250kHz DRG “wineglass” modes in single crystal silicon was reduced from >10kHz to as los as 96Hz without any electrostatic tuning. These results allow development of high-performance miniature DRGs tuned for degenerate-mode operation from high-quality crystalline silicon material.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2159547X,p. 1723-1726
Geometric compensation of (100) single crystal silicon disk resonating gyroscope for mode-matching
In this paper, we show two methods for modifying the design of a Disk Resonating Gyroscope (DRG) to compensate for the mechanical anisotropy in single crystal silicon. This method is validated through experimental characterization of more than 70 different devices. With the proposed methods, the frequency split of the 250kHz DRG “wineglass” modes in single crystal silicon was reduced from >10kHz to as los as 96Hz without any electrostatic tuning. These results allow development of high-performance miniature DRGs tuned for degenerate-mode operation from high-quality crystalline silicon material.