Mohamed Anwar Abouelatta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohamed Anwar Abouelatta has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Muhammed Omar
Shoubra Faculty of Engineering Benha University 108 Shoubra St. Cairo Egypt
3 shared publications Abd-Elhadi R. Salama
Benha Univ, Fac Engn Shoubra, 108 Shoubra St, Cairo, Egypt
2 shared publications- Kamal Mohamed Ahmed
Plasma and Nuclear Fusion Department, Nuclear Research Center, Egyptian Atomic Energy Authority, Cairo, Egypt
2 shared publications - Mohamed M. F. Darwish
Department of Electrical Engineering, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt
2 shared publications Sayed A. Ward
Department of Electrical Engineering, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt
2 shared publications- Tarek M. Allam
Plasma and Nuclear Fusion, Nuclear Research Center, Inshas, Inshas, Sharqia, 13759, EGYPT
2 shared publications
Latest Publications
- 9 October 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Impact of surface protrusions on negative corona discharge onset voltage for high–voltage stranded conductors
- 9 October 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Impact of surface protrusions on negative corona discharge onset voltage for high–voltage stranded conductors
- 16 May 2021
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 23 (7) , 075405
Magnetic field induction and magnetic force distribution profiles in plasma focus discharge device
We report a simple-to-perform technique to investigate the distribution of the azimuthal magnetic field induction, B θ , and the induced magnetic force acting on the plasma current sheath (PCS) in a plasma focus (PF) discharge. This in situ measurement technique can undoubtedly be beneficial when other fast-imaging techniques are not available. techniques are not available. Experimental work was conducted in the low-energy Mather-type EAEA-PF1 device operated in argon. The axial distribution (B θ ) z along the coaxial electrodes system was measured with a four magnetic-probe set technique at different radial distances (r = 2.625 × 10−2 to 4.125 × 10−2 m) within the annular space between the coaxial electrodes during the 1st and 2nd half cycles of the discharge current waveform, where inner electrode of coaxial electrode system has a +ve polarity and −ve polarity, respectively. Axial, radial and total magnetic force distribution profiles were estimated from B θ data. Investigation of PCS shape in terms of its inclination (curvature) angle, θ, along the axial rundown phase and the correlation between the magnetic forces per unit volume acting on the PCS, the inclination angle θ of the PCS, and the formation of a powerful PF action during the 1st and 2nd half cycles is carried out. Dependence of inclination angle, θ, on total magnetic force per unit volume acting on PCS axial motion was studied, separately, during the 1st and 2nd half cycles.
- 16 May 2021
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 23 (7) , 075405
Magnetic field induction and magnetic force distribution profiles in plasma focus discharge device
We report a simple-to-perform technique to investigate the distribution of the azimuthal magnetic field induction, B θ , and the induced magnetic force acting on the plasma current sheath (PCS) in a plasma focus (PF) discharge. This in situ measurement technique can undoubtedly be beneficial when other fast-imaging techniques are not available. techniques are not available. Experimental work was conducted in the low-energy Mather-type EAEA-PF1 device operated in argon. The axial distribution (B θ ) z along the coaxial electrodes system was measured with a four magnetic-probe set technique at different radial distances (r = 2.625 × 10−2 to 4.125 × 10−2 m) within the annular space between the coaxial electrodes during the 1st and 2nd half cycles of the discharge current waveform, where inner electrode of coaxial electrode system has a +ve polarity and −ve polarity, respectively. Axial, radial and total magnetic force distribution profiles were estimated from B θ data. Investigation of PCS shape in terms of its inclination (curvature) angle, θ, along the axial rundown phase and the correlation between the magnetic forces per unit volume acting on the PCS, the inclination angle θ of the PCS, and the formation of a powerful PF action during the 1st and 2nd half cycles is carried out. Dependence of inclination angle, θ, on total magnetic force per unit volume acting on PCS axial motion was studied, separately, during the 1st and 2nd half cycles.
- Open Access
- 15 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 225872-225883
Fast Corona Discharge Assessment Using FDM integrated With Full Multigrid Method in HVDC Transmission Lines Considering Wind Impact
A novel approach for solving the monopolar corona in high voltage direct current (HVDC) transmission line systems is proposed by the finite difference method (FDM) and a full multigrid method (FMG). Specifically, the FMG is implemented as a fast solver with respect to existing iterative solutions for the FDM to solve the Poisson equation, particularly on fine grids. The advantage features of the proposed approach are that it avoids the hypothesis of a constant electric field around the conductor's surface. Further, it considers the influence of space charge on both the magnitude and the direction of the electrical field. The proposed approach is employed for computing the electric field and current density on the ground plane with and without wind effect. Considering the impact of wind in the present study, the findings confirm that both corona current density and electric field on the ground plane are influenced by the transverse wave. Eventually, the effect of changing the wind speed on the electric field profiles and the current density is deeply studied in HVDC transmission line systems. To prove the efficacy of the proposed approach, it is compared with previous experimental results where a better agreement is reached rather than other numerical techniques.
- 15 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 225872-225883
Open AccessFast Corona Discharge Assessment Using FDM integrated With Full Multigrid Method in HVDC Transmission Lines Considering Wind Impact
A novel approach for solving the monopolar corona in high voltage direct current (HVDC) transmission line systems is proposed by the finite difference method (FDM) and a full multigrid method (FMG). Specifically, the FMG is implemented as a fast solver with respect to existing iterative solutions for the FDM to solve the Poisson equation, particularly on fine grids. The advantage features of the proposed approach are that it avoids the hypothesis of a constant electric field around the conductor's surface. Further, it considers the influence of space charge on both the magnitude and the direction of the electrical field. The proposed approach is employed for computing the electric field and current density on the ground plane with and without wind effect. Considering the impact of wind in the present study, the findings confirm that both corona current density and electric field on the ground plane are influenced by the transverse wave. Eventually, the effect of changing the wind speed on the electric field profiles and the current density is deeply studied in HVDC transmission line systems. To prove the efficacy of the proposed approach, it is compared with previous experimental results where a better agreement is reached rather than other numerical techniques.
- 1 December 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 189
Optimal grid size for precipitators using finite difference method based on full multi-grid method
- 1 December 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 189
Optimal grid size for precipitators using finite difference method based on full multi-grid method
- Open Access
- 1 May 2019
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 13 (3) , 453-460
Fast corona discharge solver for precipitators using multi‐grid methods on fine grids
A novel approach for modelling the corona problem in the wire‐duct precipitators using the finite difference technique integrated with multi‐grid methods is adopted in this study. The multi‐grid method is applied as a fast convergent iterative solution for the finite difference technique to solve Poisson equation especially on finer grids. Two schemes of the multi‐grid method, mainly the V‐cycle and the full multi‐grid method, are adopted in the present study. Compared with Gauss–Seidel method, the above‐mentioned schemes are successfully transcendent owing to timing performance. By using finer grids, the proposed algorithm allows to get a more accurate picture about the performance of the precipitators in the design stage without suffering from the excessive computational time. Accurate results for the potential and current density computations, closed to the previous published experimental measurements, are obtained in comparison with earlier numerical techniques for several design parameters of the precipitators. Finally, the effect of changing the effective ion mobility and the surface roughness factor on the voltage–current density is considered.
- 1 May 2019
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 13 (3) , 453-460
Open AccessFast corona discharge solver for precipitators using multi‐grid methods on fine grids
A novel approach for modelling the corona problem in the wire‐duct precipitators using the finite difference technique integrated with multi‐grid methods is adopted in this study. The multi‐grid method is applied as a fast convergent iterative solution for the finite difference technique to solve Poisson equation especially on finer grids. Two schemes of the multi‐grid method, mainly the V‐cycle and the full multi‐grid method, are adopted in the present study. Compared with Gauss–Seidel method, the above‐mentioned schemes are successfully transcendent owing to timing performance. By using finer grids, the proposed algorithm allows to get a more accurate picture about the performance of the precipitators in the design stage without suffering from the excessive computational time. Accurate results for the potential and current density computations, closed to the previous published experimental measurements, are obtained in comparison with earlier numerical techniques for several design parameters of the precipitators. Finally, the effect of changing the effective ion mobility and the surface roughness factor on the voltage–current density is considered.
- Open Access
- 1 December 2018
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 9 (4) , 2311-2321
Experimental and numerical investigations of the Laplacian and Poissonian field in asymmetric multiple-electrode systems for electrostatic separation processes
- 1 December 2018
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 9 (4) , 2311-2321
Open AccessExperimental and numerical investigations of the Laplacian and Poissonian field in asymmetric multiple-electrode systems for electrostatic separation processes
- Open Access
- 1 December 2018
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 9 (4) , 1243-1250
An equivalent electrode system for efficient charging of filtration media
- 1 December 2018
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 9 (4) , 1243-1250
Open AccessAn equivalent electrode system for efficient charging of filtration media
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 875-881
Negative Corona Inception Voltage Determination in the Three-Electrode System
This paper presents the theoretical and experimental study of the negative corona inception voltage of the ionized conductor on the three electrode system in air. The proposed three-electrode system modifies the usual two-electrode system implemented in the filtration process by entering a supplementary cylinder free to move in x-y directions. The three-electrode system is constructed to regulate the field distribution on the surface of the ionized conductor and on the ground plate besides changing the corona inception voltage. The negative corona inception voltage is determined according to the principle developed for the forming of the recurrence of negative corona current pulses in the near vicinity of the stressed conductor. The computation of the free space charge field is determined using the charge simulation technique with the aid of the genetic algorithms. The obtained field values are harnessed in the negative corona inception voltage computation of the ionized conductor. Experimental measurements of the negative corona inception voltage of the ionized wire are carried out. The effect of moving the supplementary cylinder in both directions on the inception voltage is determined theoretically and experimentally. The results showed the effectiveness of the supplementary cylinder on controlling the inception voltage level upon the ionized conductor. The calculated inception voltage coincided in an acceptable way with those measured in the laboratory.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 875-881
Negative Corona Inception Voltage Determination in the Three-Electrode System
This paper presents the theoretical and experimental study of the negative corona inception voltage of the ionized conductor on the three electrode system in air. The proposed three-electrode system modifies the usual two-electrode system implemented in the filtration process by entering a supplementary cylinder free to move in x-y directions. The three-electrode system is constructed to regulate the field distribution on the surface of the ionized conductor and on the ground plate besides changing the corona inception voltage. The negative corona inception voltage is determined according to the principle developed for the forming of the recurrence of negative corona current pulses in the near vicinity of the stressed conductor. The computation of the free space charge field is determined using the charge simulation technique with the aid of the genetic algorithms. The obtained field values are harnessed in the negative corona inception voltage computation of the ionized conductor. Experimental measurements of the negative corona inception voltage of the ionized wire are carried out. The effect of moving the supplementary cylinder in both directions on the inception voltage is determined theoretically and experimentally. The results showed the effectiveness of the supplementary cylinder on controlling the inception voltage level upon the ionized conductor. The calculated inception voltage coincided in an acceptable way with those measured in the laboratory.
- 28 October 2016
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 76 (1) , 10803
Development of a low-cost atmospheric non-thermal plasma jet and its characteristics in air and nitrogen
This paper deals with the development of a low-cost atmospheric non-thermal plasma jet (ANPJ) which was designed and operated previously in our laboratory. The purpose of the developed design with a small size less than 4% of the previous volume is to obtain a more portable device which holds promise for various fields of applications. The discharge is operated separately with compressed air and nitrogen gas with flow rates varied within the range of 3–18 L/min. The plasma plume length and thickness are measured as a function of the gas flow rate and input voltage V input within the range of 3–18 L/min and 2–6 kV respectively. The results showed that for nitrogen gas, the maximum values of the plume length and thickness are 20 mm and 1.3 mm respectively at a flow rate of 12 L/min and V input = 6 kV. Results of electrical characterization at V input = 6 kV such as discharge voltage, discharge current, the mean consumed power and energy showed that the maximum values of these parameters are obtained at a flow rate of 12 L/min. The developed design is found to be saving up to 65.47% and 68.54% of the consumed power compared to the previous design in the case of air and N2 respectively. The new proposed configuration for the developed ANPJ offers more suitable characteristics than the earlier designs, especially for nitrogen gas.
- 28 October 2016
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 76 (1) , 10803
Development of a low-cost atmospheric non-thermal plasma jet and its characteristics in air and nitrogen
This paper deals with the development of a low-cost atmospheric non-thermal plasma jet (ANPJ) which was designed and operated previously in our laboratory. The purpose of the developed design with a small size less than 4% of the previous volume is to obtain a more portable device which holds promise for various fields of applications. The discharge is operated separately with compressed air and nitrogen gas with flow rates varied within the range of 3–18 L/min. The plasma plume length and thickness are measured as a function of the gas flow rate and input voltage V input within the range of 3–18 L/min and 2–6 kV respectively. The results showed that for nitrogen gas, the maximum values of the plume length and thickness are 20 mm and 1.3 mm respectively at a flow rate of 12 L/min and V input = 6 kV. Results of electrical characterization at V input = 6 kV such as discharge voltage, discharge current, the mean consumed power and energy showed that the maximum values of these parameters are obtained at a flow rate of 12 L/min. The developed design is found to be saving up to 65.47% and 68.54% of the consumed power compared to the previous design in the case of air and N2 respectively. The new proposed configuration for the developed ANPJ offers more suitable characteristics than the earlier designs, especially for nitrogen gas.
- Open Access
- 6 December 2011
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 3 (1) , 27-31
Assessment of uncertainties in substation grounding system using interval mathematics
- 6 December 2011
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 3 (1) , 27-31
Open AccessAssessment of uncertainties in substation grounding system using interval mathematics