TATarek M. Allam

Tarek M. Allam

*This is an algorithmically generated author record based on publicly available information.

Tarek M. Allam has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Magnetic field induction and magnetic force distribution profiles in plasma focus discharge device

    by A A Lashin, Tarek Allam, H A El-Sayed, Kamal M Ahmed, S A Ward, Hanaa Soliman, M A Abouelatta

    We report a simple-to-perform technique to investigate the distribution of the azimuthal magnetic field induction, B θ , and the induced magnetic force acting on the plasma current sheath (PCS) in a plasma focus (PF) discharge. This in situ measurement technique can undoubtedly be beneficial when other fast-imaging techniques are not available. techniques are not available. Experimental work was conducted in the low-energy Mather-type EAEA-PF1 device operated in argon. The axial distribution (B θ ) z along the coaxial electrodes system was measured with a four magnetic-probe set technique at different radial distances (r = 2.625 × 10−2 to 4.125 × 10−2 m) within the annular space between the coaxial electrodes during the 1st and 2nd half cycles of the discharge current waveform, where inner electrode of coaxial electrode system has a +ve polarity and −ve polarity, respectively. Axial, radial and total magnetic force distribution profiles were estimated from B θ data. Investigation of PCS shape in terms of its inclination (curvature) angle, θ, along the axial rundown phase and the correlation between the magnetic forces per unit volume acting on the PCS, the inclination angle θ of the PCS, and the formation of a powerful PF action during the 1st and 2nd half cycles is carried out. Dependence of inclination angle, θ, on total magnetic force per unit volume acting on PCS axial motion was studied, separately, during the 1st and 2nd half cycles.


  • Plasma Current Sheath Shape and Trapping Efficiency in the 2.2-kJ EAEA-PF1 Plasma Focus Device

    by H. A. El-Sayed, T. M. Allam, H. M. Soliman

    The plasma current sheath (PCS) shape and trapping efficiency η are investigated experimentally. The experiments are carried out at the 2.2-kJ Egyptian Atomic Energy Authority Plasma Focus...


  • Numerical Experiments to Optimize Argon Soft X-Ray Yield in a Low-Energy Plasma Focus

    by Kamal M. Ahmed, Tarek M. Allam, Hanaa A. El-Sayed, Fathy B. Diab, Hanaa M. Soliman

    Numerical experiments are carried out on a low-energy (2.2 kJ) Mather-type Egyptian Atomic Energy Authority-Plasma Focus (EAEA-PF1) to investigate the optimum combination of all electrode system dimensions and gas pressure for maximum argon soft X-ray (SXR) yield, YSXR, using Lee Model RADPF5.15. This paper aims to finalize the first step prior to building an automated method of optimization that could be applied when a low-energy dense plasma focus is designed or need to be reconfigured, for this purpose, and to assist further research efforts in this field. The second part of the study deals with the investigation of the role of changing outer electrode radius ``b'' and the outer to inner radii ratio ``c'' on plasma focus (PF) parameters such as ion density, pinch duration, and column length and how are these, consequently, related to the maximum SXR yield. It is shown that lower radius ratio values (typically less than 2) are favored over higher ones, for argon SXR yield, and unlike most of the low-energy PF devices that are designed for this purpose. It is also shown that inductance and pinch current are only affected by the dimension of inner electrode radius, while the ion density, pinch duration, and focus volume are also affected by the change of outer electrode radius.


  • Power density measurements to optimize AC plasma jet operation in blood coagulation

    by Kamal M. Ahmed, Shaimaa M. Eldeighdye, Tarek M. Allam, Walaa F. Hassanin

    In this paper, the plasma power density and corresponding plasma dose of a low-cost air non-thermal plasma jet (ANPJ) device are estimated at different axial distances from the nozzle. This estimation is achieved by measuring the voltage and current at the substrate using diagnostic techniques that can be easily made in laboratory; thin wire and dielectric probe, respectively. This device uses a compressed air as input gas instead of the relatively-expensive, large-sized and heavy weighed tanks of Ar or He gases. The calculated plasma dose is found to be very low and allows the presented device to be used in biomedical applications (especially blood coagulation). While plasma active species and charged-particles are found to be the most effective on blood coagulation formation, both air flow and UV, individually, do not have any effect. Moreover, optimal conditions for accelerating blood coagulation are studied. Results showed that, the power density at the substrate is shown to be decreased with increasing the distance from the nozzle. In addition, both distances from nozzle and air flow rate play an important role in accelerating blood coagulation process. Finally, this device is efficient, small-sized, safe enough, of low cost and, hence, has its chances to be wide spread as a first aid and in ambulance.


  • Open Access

    Insulating Material Erosion in Atmospheric Non-Thermal Plasma Jet Device

    by K. M. Ahmed, T. M. Allam, M. A. Abouelatta, S. A. Ward, A. A. Lashin, H. M. Soliman

    This paper reports on the selection of insulating material types in a developed atmospheric-pressure non-thermal plasma jet (ANPJ-II) device which was operated previously in our laboratory based on the minimum erosion area of the insulator’s nozzle. Three identical insulator groups used in our experiment include; Teflon insulator material with different thicknesses of 1.5 mm and 2 mm respectively, and Ceramic insulating material with thickness of 2 mm. ANPJ-II device is operated with each of the three insulator groups. These insulators are operated and analyzed with different operation times for compressed Air or Nitrogen gas with a flow rate of 12 L/min and input voltage of 6 kV. The erosion area of these insulator materials is measured as a function of the operation time. The Ceramic insulator was found to have the minimum erosion area. Also, the temperature of both the cathode and the insulating material (Teflon or Ceramic) are measured to study the effect of operation time and the gas type on the device components.

  • Development of a low-cost atmospheric non-thermal plasma jet and its characteristics in air and nitrogen

    by Tarek M. Allam, Kamal M. Ahmed, Mohamed A. Abouelatta, Sayed A. Ward, Ahmed A. Lashin, Hanaa M. Soliman

    This paper deals with the development of a low-cost atmospheric non-thermal plasma jet (ANPJ) which was designed and operated previously in our laboratory. The purpose of the developed design with a small size less than 4% of the previous volume is to obtain a more portable device which holds promise for various fields of applications. The discharge is operated separately with compressed air and nitrogen gas with flow rates varied within the range of 3–18 L/min. The plasma plume length and thickness are measured as a function of the gas flow rate and input voltage V input within the range of 3–18 L/min and 2–6 kV respectively. The results showed that for nitrogen gas, the maximum values of the plume length and thickness are 20 mm and 1.3 mm respectively at a flow rate of 12 L/min and V input = 6 kV. Results of electrical characterization at V input = 6 kV such as discharge voltage, discharge current, the mean consumed power and energy showed that the maximum values of these parameters are obtained at a flow rate of 12 L/min. The developed design is found to be saving up to 65.47% and 68.54% of the consumed power compared to the previous design in the case of air and N2 respectively. The new proposed configuration for the developed ANPJ offers more suitable characteristics than the earlier designs, especially for nitrogen gas.


  • Open Access

    Insulating Material Erosion in Atmospheric Non-Thermal Plasma Jet Device

    by Kamal M Ahmed, Tarek M Allam, Mohamed Anwar Abouelatta, Sayed A Ward, Ahmed A Lashin, Hanaa M Soliman

    This paper reports on the selection of insulating material types in a developed atmospheric-pressure non-thermal plasma jet (ANPJ-II) device which was operated previously in our laboratory based on the minimum erosion area of the insulator’s nozzle. Three identical insulator groups used in our experiment include; Teflon insulator material with different thicknesses of 1.5 mm and 2 mm respectively, and Ceramic insulating material with thickness of 2 mm. ANPJ-II device is operated with each of the three insulator groups. These insulators are operated and analyzed with different operation times for compressed Air or Nitrogen gas with a flow rate of 12 L/min and input voltage of 6 kV. The erosion area of these insulator materials is measured as a function of the operation time. The Ceramic insulator was found to have the minimum erosion area. Also, the temperature of both the cathode and the insulating material (Teflon or Ceramic) are measured to study the effect of operation time and the gas type on the device components.


  • Design, Construction and Characterization of AC Atmospheric Pressure Air Non-thermal Plasma Jet

    by K. M. Ahmed, T. M. Allam, H. A. El-Sayed, H. M. Soliman, S. A. Ward, E. M. Saied


  • Study of a cumulative gas phenomenon in plasma focus discharge

    by H. M. Soliman, T. M. Allam, S. T. Abd El-Latif

    A cumulative phenomenon of nitrogen gas at a pressure of 3.3 torr in a 1.2 kJ coaxial plasma focus discharge device was investigated experimentally. Variations of nitrogen gas density in the axial phase along the inter-electrode region were estimated experimentally from the plasma current sheath (PCS) dynamics in terms of its velocity, acceleration as well as axial magnetic force data. An inclination angle of PCS with the axial distance was estimated. Investigations of the ratios of radial and axial magnetic force as well as the magnetic pressures coupled to PCS were studied. The variation of the trapping fraction η with the axial distance was computed theoretically based on a snow-plow model and was compared with experimental results.