Hie Chan Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hie Chan Kang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Young Ha Jeon
Department of Mechanical Engineering, Kunsan National University
3 shared publications - Anthony M. Jacobi
Air Conditioning and Refrigeration Center (ACRC), Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
2 shared publications Gang Gyun Lee
1 shared publication- Gil Woong Jun
Senior Researcher, Halla Climate Control Co., Deajeon 306-230, South Korea
1 shared publication - Hyejung Cho
Samsung Electronics
1 shared publication Hyun Sun Park
1 shared publication
Latest Publications
- 17 May 2026
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 722, 140725
A unified force–energy adhesion model for wettability on real solid surfaces
- 17 May 2026
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 722, 140725
A unified force–energy adhesion model for wettability on real solid surfaces
- 28 April 2026
- Published by Taylor & Francis in Heat Transfer Engineering
- p. 1-17
A Practical ε-NTU Method Incorporating Effectiveness Efficiency for Actual Plate Heat Exchangers
- 28 April 2026
- Published by Taylor & Francis in Heat Transfer Engineering
- p. 1-17
A Practical ε-NTU Method Incorporating Effectiveness Efficiency for Actual Plate Heat Exchangers
- Open Access
- 23 August 2025
- Published by Elsevier in Fire Safety Journal
- Vol. 157
Cooling water injection for EV battery fires: A targeted method to suppress thermal runaway
- 23 August 2025
- Published by Elsevier in Fire Safety Journal
- Vol. 157
Open AccessCooling water injection for EV battery fires: A targeted method to suppress thermal runaway
- Open Access
- 5 December 2024
- Published by Elsevier in Results in Engineering
- Vol. 25
An empirical correlation for enhanced heat transfer in spirally fluted tube crossflow convection
- 5 December 2024
- Published by Elsevier in Results in Engineering
- Vol. 25
Open AccessAn empirical correlation for enhanced heat transfer in spirally fluted tube crossflow convection
- 28 March 2024
- Published by Springer Nature in International Journal of Automotive Technology
- Vol. 25 (5) , 989-998
Experiment on Extinguishing Thermal Runaway in a Scaled-Down Model of an Electric Vehicle Battery
- 28 March 2024
- Published by Springer Nature in International Journal of Automotive Technology
- Vol. 25 (5) , 989-998
Experiment on Extinguishing Thermal Runaway in a Scaled-Down Model of an Electric Vehicle Battery
- 1 September 2019
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 44 (43) , 24036-24042
Performance of unit PEM fuel cells with a leaf-vein-simulating flow field-patterned bipolar plate
- 1 September 2019
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 44 (43) , 24036-24042
Performance of unit PEM fuel cells with a leaf-vein-simulating flow field-patterned bipolar plate
- Open Access
- 1 April 2017
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 49 (3) , 459-465
Effective Thermal Conductivity and Diffusivity of Containment Wall for Nuclear Power Plant OPR1000
- 1 April 2017
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 49 (3) , 459-465
Open AccessEffective Thermal Conductivity and Diffusivity of Containment Wall for Nuclear Power Plant OPR1000
- 13 March 2014
- Published by ASME International in Journal of Fuel Cell Science and Technology
- Vol. 11 (4) , 041004
Air-Side Heat Transfer Performance of Louver Fin and Multitube Heat Exchanger for Direct Methanol Fuel Cell Cooling Application
The present work is performed to evaluate the heat transfer performance of a heat exchanger used in a direct methanol fuel cell. Because of material constraints and performance requirements, a louver fin heat exchanger is modified for use with conventional microchannel tubes and also with multiple small-diameter tubes (called multitubes). Prototype heat exchangers are tested, and the air-side heat transfer, pressure drop, and fan power are measured in a wind tunnel and simulated using a commercial code. The air-side pressure drop and heat transfer coefficient of the multitubes show similar trends to those of the flat-tube heat exchanger if the contact resistance is negligible. The tube spacing of the prototype multitube heat exchangers has a small effect on the pressure drop and heat transfer, but it has a profound effect on the air-side heat transfer performance because of the contact resistance between the tubes and louver fins. The air-side pressure drop agrees well with an empirical correlation for flat tubes.
- 13 March 2014
- Published by ASME International in Journal of Fuel Cell Science and Technology
- Vol. 11 (4) , 041004
Air-Side Heat Transfer Performance of Louver Fin and Multitube Heat Exchanger for Direct Methanol Fuel Cell Cooling Application
The present work is performed to evaluate the heat transfer performance of a heat exchanger used in a direct methanol fuel cell. Because of material constraints and performance requirements, a louver fin heat exchanger is modified for use with conventional microchannel tubes and also with multiple small-diameter tubes (called multitubes). Prototype heat exchangers are tested, and the air-side heat transfer, pressure drop, and fan power are measured in a wind tunnel and simulated using a commercial code. The air-side pressure drop and heat transfer coefficient of the multitubes show similar trends to those of the flat-tube heat exchanger if the contact resistance is negligible. The tube spacing of the prototype multitube heat exchangers has a small effect on the pressure drop and heat transfer, but it has a profound effect on the air-side heat transfer performance because of the contact resistance between the tubes and louver fins. The air-side pressure drop agrees well with an empirical correlation for flat tubes.
- 23 November 2011
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 27 (24) , 14910-14918
Equilibrium Contact Angles of Liquid Droplets on Ideal Rough Solids
This work proposes a theoretical model for predicting the apparent equilibrium contact angle of a liquid on an ideal rough surface that is homogeneous and has a negligible body force, line tension, or contact angle hysteresis between solid and liquid. The model is derived from the conservation equations and the free-energy minimization theory for the changes of state of liquid droplets. The work of adhesion is expressed as the contact angles in the wetting process of the liquid droplets. Equilibrium contact angles of liquid droplets for rough surfaces are expressed as functions of the area ratios for the solid, liquid, and surrounding gas and the roughness ratio and wetting ratio of the liquid on the solid for the partially and fully wet states. It is found that the ideal critical angle for accentuating the contact angles by the surface roughness is 48°. The present model is compared with existing experimental data and the classical Wenzel and Cassie–Baxter models and agrees with most of the experimental data for various surfaces and liquids better than does the Wenzel model and accounts for trends that the Wenzel model cannot explain.
- 23 November 2011
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 27 (24) , 14910-14918
Equilibrium Contact Angles of Liquid Droplets on Ideal Rough Solids
This work proposes a theoretical model for predicting the apparent equilibrium contact angle of a liquid on an ideal rough surface that is homogeneous and has a negligible body force, line tension, or contact angle hysteresis between solid and liquid. The model is derived from the conservation equations and the free-energy minimization theory for the changes of state of liquid droplets. The work of adhesion is expressed as the contact angles in the wetting process of the liquid droplets. Equilibrium contact angles of liquid droplets for rough surfaces are expressed as functions of the area ratios for the solid, liquid, and surrounding gas and the roughness ratio and wetting ratio of the liquid on the solid for the partially and fully wet states. It is found that the ideal critical angle for accentuating the contact angles by the surface roughness is 48°. The present model is compared with existing experimental data and the classical Wenzel and Cassie–Baxter models and agrees with most of the experimental data for various surfaces and liquids better than does the Wenzel model and accounts for trends that the Wenzel model cannot explain.