SGSteffen Greilich

Steffen Greilich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steffen Greilich has a total of 164 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Monte Carlo simulation for proton dosimetry in magnetic fields: Fano test and magnetic field correction factors k B for Farmer-type ionization chambers

    by M Marot, F Jäger, S Greilich, C P Karger, O Jäkel, L N Burigo

    Objective . In this contribution we present a special Fano test for charged particles in presence of magnetic fields in the MC code TOol for PArticle Simulation (TOPAS), as well as the determination of magnetic field correction factors k B for Farmer-type ionization chambers using proton beams. Approach . Customized C++ extensions for TOPAS were implemented to model the special Fano tests in presence of magnetic fields for electrons and protons. The Geant4-specific transport parameters, DRoverR and finalRange, were investigated to optimize passing rate and computation time. The k B was determined for the Farmer-type PTW 30013 ionization chamber, and 5 custom built ionization chambers with same geometry but varying inner radius, testing magnetic flux density ranging from 0 to 1.0 T and two proton beam energies of 157.43 and 221.05 MeV. Main results . Using the investigated parameters, TOPAS passed the Fano test within 0.39 ± 0.15% and 0.82 ± 0.42%, respectively for electrons and protons. The chamber response ( k B,M,Q ) gives a maximum at different magnetic flux densities depending of the chamber size, 1.0043 at 1.0 T for the smallest chamber and 1.0051 at 0.2 T for the largest chamber. The local dose difference c B remained ≤ 0.1% for both tested energies. The magnetic field correction factor k B , for the chamber PTW 30013, varied from 0.9946 to 1.0036 for both tested energies. Significance . The developed extension for the special Fano test in TOPAS MC code with the adjusted transport parameters, can accurately transport electron and proton particles in magnetic field. This makes TOPAS a valuable tool for the determination of k B . The ionization chambers we tested showed that k B remains small (≤0.72%). To the best of our knowledge, this is the first calculations of k B for proton beams. This work represents a significant step forward in the development of MRgPT and protocols for proton dosimetry in presence of magnetic field.


  • Open Access

    Proton beam dosimetry in the presence of magnetic fields using Farmer‐type ionization chambers of different radii

    by Mathieu Marot, Sonja Surla, Elisa Burke, Stephan Brons, Armin Runz, Steffen Greilich, Christian P. Karger, Oliver Jäkel, Lucas N. Burigo

    Background: Magnetic resonance‐guided proton therapy is promising, as it combines high‐contrast imaging of soft tissue with highly conformal dose delivery. However, proton dosimetry in magnetic fields using ionization chambers is challenging since the dose distribution as well as the detector response are perturbed.Purpose: This work investigates the effect of the magnetic field on the ionization chamber response, and on the polarity and ion recombination correction factors, which are essential for the implementation of a proton beam dosimetry protocol in the presence of magnetic fields.Methods: Three Farmer‐type cylindrical ionization chambers, the 30013 with 3 mm inner radius (PTW, Freiburg, Germany) and two custom built chambers “R1” and “R6” with 1 and 6 mm inner radii respectively were placed at the center of an experimental electromagnet (Schwarzbeck Mess – Elektronik, Germany) 2 cm depth of an in‐house developed 3D printed water phantom. The detector response was measured for a 3 × 10 cm2 field of mono‐energetic protons 221.05 MeV/u for the three chambers, and with an additional proton beam of 157.43 MeV/u for the chamber PTW 30013. The magnetic flux density was varied between 0.1 and 1.0 Tesla in steps of 0.1 Tesla.Results: At both energies, the ionization chamber PTW 30013 showed a non‐linear response as a function of the magnetic field strength, with a decrease of the ionization chamber response of up to 0.27% ± 0.06% (1 SD) at 0.2 Tesla, followed by a smaller effect at higher magnetic field strength. For the chamber R1, the response decreased slightly with the magnetic field strength up to 0.45% ± 0.12% at 1 Tesla, and for the chamber R6, the response decreased up to 0.54% ± 0.13% at 0.1 Tesla, followed by a plateau up to 0.3 Tesla, and a weaker effect at higher magnetic field strength. The dependence of the polarity and recombination correction factor on the magnetic field was ⩽0.1% for the chamber PTW 30013.Conclusions: The magnetic field has a small but significant effect on the chamber response in the low magnetic field region for the chamber PTW 30013 and for R6, and in the high magnetic field region for the chamber R1. Corrections may be necessary for ionization chamber measurements, depending on both the chamber volume and the magnetic flux density. No significant effect of the magnetic field on the polarity and recombination correction factor was detected in this work for the ionization chamber PTW 30013.


  • Open Access

    Biosensor for deconvolution of individual cell fate in response to ion beam irradiation

    by Martin Niklas, Julian Schlegel, Hans Liew, Ferdinand Zimmermann, Katrin Rein, Dietrich W.M. Walsh, Oleh Dzyubachyk, Tim Holland-Letz, Shirin Rahmanian, Steffen Greilich, et al.


  • Open Access

    Refinement of the Hounsfield look‐up table by retrospective application of patient‐specific direct proton stopping‐power prediction from dual‐energy CT

    by Patrick Wohlfahrt, Christian Möhler, Wolfgang Enghardt, Mechthild Krause, Daniela Kunath, Stefan Menkel, Esther G. C. Troost, Steffen Greilich, Christian Richter

    Background and Purpose: Proton treatment planning relies on an accurate determination of stopping‐power ratio (SPR) from x‐ray computed tomography (CT). A refinement of the heuristic CT‐based SPR prediction using a state‐of‐the‐art Hounsfield look‐up table (HLUT) is proposed, which incorporates patient SPR information obtained from dual‐energy CT (DECT) in a retrospective patient‐cohort analysis.Material and Methods: SPR datasets of 25 brain‐tumor patients, 25 prostate‐cancer patients, and three nonsmall cell lung‐cancer (NSCLC) patients were calculated from clinical DECT scans with the comprehensively validated DirectSPR approach. Based on the median frequency distribution of voxelwise correlations between CT number and SPR within the irradiated volume, a piecewise linear function was specified (DirectSPR‐based adapted HLUT). Differences in dose distribution and proton range were assessed for the nonadapted and adapted HLUT in comparison to the DirectSPR method, which has been shown to be an accurate and reliable SPR estimation method.Results: The application of the DirectSPR‐based adapted HLUT instead of the nonadapted HLUT reduced the systematic proton range differences from 1.2% (1.1 mm) to −0.1% (0.0 mm) for brain‐tumor patients, 1.7% (4.1 mm) to 0.2% (0.5 mm) for prostate‐cancer patients, and 2.0% (2.9 mm) to −0.1% (0.0 mm) for NSCLC patients. Due to the large intra‐ and inter‐patient tissue variability, range differences to DirectSPR larger than 1% remained for the adapted HLUT.Conclusions: The incorporation of patient‐specific correlations between CT number and SPR, derived from a retrospective application of DirectSPR to a broad patient cohort, improves the SPR accuracy of the current state‐of‐the‐art HLUT approach. The DirectSPR‐based adapted HLUT has been clinically implemented at the University Proton Therapy Dresden (Dresden, Germany) in 2017. This already facilitates the benefits of an improved DECT‐based tissue differentiation within clinical routine without changing the general approach for range prediction (HLUT), and represents a further step toward full integration of the DECT‐based DirectSPR method for treatment planning in proton therapy.


  • Open Access

    Impact of new ICRU90 key data on stopping-power ratios and beam quality correction factors for carbon ion beams

    by Lucas Burigo, Steffen Greilich

    The recent update of dosimetric key data by the `International Commission on Radiation Units and Measurements' impacts the computation of beam quality correction factors $k_Q$ via several changes, e.g. for the mean excitation energies, $I$, which enters the stopping power computation for water and air, the computation procedure itself, the average energy expended in the production of an ion pair in air, $W/e$, as well as chamber perturbation factors for Cobalt-60. An accurate assessment of water-to-air stopping-power ratio, $s_{\rm w,air}$, in reference conditions with new recommendation is necessary to update the dosimetry protocols for carbon ion beams. The new ICRU90 key data were considered for computation of $s_{\rm w,air}$ for carbon ion beams using Monte Carlo transport simulations for a number of reference conditions, namely monoenergetic carbon ion beams with range in water from 3 to 30\,cm and Spread-Out Bragg peaks (SOBPs) of different widths and depths in water. New recommendations for $s_{\rm w,air}$ are presented, namely 1.1247 for the reference condition of 1\,g\,cm$^{-2}$ depth for monoenergetic carbon ion beams and 1.1274 at the center of physically-optimized SOBPs. The recommendation of a constant value (1.126) represents the stopping-power ratio within a 0.3\,\% variation of $s_{\rm w,air}$ for the different reference conditions. The impact of these new $s_{\rm w,air}$ values and the updated key data on the $k_Q$ for carbon ion beams was evaluated in a second step. The changes agree very well with experimental data for the case of cylindrical ionization chambers, but larger discrepancies are observed for plate-parallel ionization chambers.

  • Open Access

    The ADAM-pelvis phantom—an anthropomorphic, deformable and multimodal phantom for MRgRT

    by N I Niebuhr, Wibke Johnen, Gernot Echner, Armin Runz, Michael Bach, Markus Stoll, Kristina Giske, Steffen Greilich, Asja Pfaffenberger

    Applicability and accuracy of the rapidly developing tools and workflows for image-guided radiotherapy need to be validated under realistic treatment-like conditions. We present the construction of the ADAM-pelvis phantom, an anthropomorphic, deformable and multimodal (CT and MRI) phantom of the male pelvis. The phantom covers patient-like uncertainties in image-guided radiotherapy workflows including imaging artifacts for the special case of the human anatomy as well as organ motion. Principles and methods were further improved from previous work. The phantom includes surrogates for muscle tissue, adipose, inner and outer bone, as well as deformable silicone organs. Anthropomorphic shapes are realized with 3D-printing techniques for the bone and the construction of the hollow silicone organ shells. Organs are constructed from patient image segmentation and further guided by reported deformation models. Imaging markers and pockets for dosimeters are included in the organ shells. The improved phantom surrogates match imaging characteristics in MRI (T1 and T2 relaxation time) and CT (Hounsfield units) of human tissues. The surrogates are suited for long term use (several months) of the phantom. Previously reported artifacts of the muscle surrogate were avoided by improved composition of the used agarose gel. Interfractional organ motion is successfully realized for the water filled bladder and the air filled rectum and showed to be reproducible with deviation below 1 mm. Volume variations of both induce displacement, rotation and deformation of the prostate. We present solutions for the construction of an anthropomorphic phantom suitable for MRI and CT imaging including deformable organs. The developed concepts of phantom surrogates and construction techniques were successfully applied in building the ADAM-pelvis phantom and can as well be adopted for other anthropomorphic phantoms. The presented phantom allows for the systematic and controlled investigation of image-guided radiotherapy workflows in presence of organ motion.


  • Strahlenphysik

    by Steffen Greilich, Julia-Maria Osinga-Blättermann

  • [I206] Dual energy CT for improved range prediction in proton therapy: What can we gain?

    by Christian Richter, Patrick Wohlfahrt, Christian Möhler, Steffen Greilich