Femke E. van Beek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Femke E. van Beek has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Astrid M. L. Kappers
Department of Behavioural and Human Movement Sciences, MOVE Research Institute Amsterdam, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
7 shared publications- Irene A. Kuling
Eindhoven University of Technology
7 shared publications Wouter M. Bergmann Tiest
Department of Behavioural and Human Movement Sciences, MOVE Research Institute Amsterdam, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
7 shared publications- Krishna Dheeraj Kommuri
Reshape Lab, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
3 shared publications - Quinten P. I. Bisschop
Reshape Lab, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
2 shared publications Bart G. A. Wolfs
VU University Amsterdam
1 shared publication
Latest Publications
- Open Access
- 4 June 2026
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 21 (4)
Exploring the Influence of Diameter-to-Length Ratios on Soft Robot Performance in Soil Environments
Soft robotics holds large promises for precision agriculture, as it has the potential to overcome challenges associated with subsoil exploration, including precision maneuvering, and minimizing soil disturbance. While prior studies have evaluated soft robots in tubes, glass beads, or sand, we perform empirical measurements and validations in real soil environments and show how the diameter-to-length (D/L) ratio affects the penetration performance, taking inspiration from earthworms' D/L ratios. Through a series of experiments, this study investigated the locomotion capabilities and the behavior of various robot designs when submerged within soil. We fabricated five pneumatically-actuated soft robots with different D/L ratios, measured their vertical burrowing depth, their axial force generation, and characterized the total drag force versus depth. We introduced a capability ratio (CR) comparing available axial force to experienced total drag at depth, giving an estimate of the theoretical depth that each design could reach before stalling. We evaluated buckling forces using Euler limits under mixed end conditions representing soil confinement and available lateral support. Results show that designs with D/L ratios similar to that of an earthworm exhibit lower drag forces, but D/L is not the only parameter influencing performance. The largest-diameter design generated the highest axial force but underperformed due to buckling, while the mid-range geometry achieved the greatest depth through a balanced combination of axial force generation, drag, and stability. These findings highlight the importance of tailored design parameters for efficient subsoil exploration, the relevance of mimicking natural proportions, and demonstrate that force-based metrics can provide practical performance estimates for soft burrowing robots.
- 4 June 2026
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 21 (4)
Open AccessExploring the Influence of Diameter-to-Length Ratios on Soft Robot Performance in Soil Environments
Soft robotics holds large promises for precision agriculture, as it has the potential to overcome challenges associated with subsoil exploration, including precision maneuvering, and minimizing soil disturbance. While prior studies have evaluated soft robots in tubes, glass beads, or sand, we perform empirical measurements and validations in real soil environments and show how the diameter-to-length (D/L) ratio affects the penetration performance, taking inspiration from earthworms' D/L ratios. Through a series of experiments, this study investigated the locomotion capabilities and the behavior of various robot designs when submerged within soil. We fabricated five pneumatically-actuated soft robots with different D/L ratios, measured their vertical burrowing depth, their axial force generation, and characterized the total drag force versus depth. We introduced a capability ratio (CR) comparing available axial force to experienced total drag at depth, giving an estimate of the theoretical depth that each design could reach before stalling. We evaluated buckling forces using Euler limits under mixed end conditions representing soil confinement and available lateral support. Results show that designs with D/L ratios similar to that of an earthworm exhibit lower drag forces, but D/L is not the only parameter influencing performance. The largest-diameter design generated the highest axial force but underperformed due to buckling, while the mid-range geometry achieved the greatest depth through a balanced combination of axial force generation, drag, and stability. These findings highlight the importance of tailored design parameters for efficient subsoil exploration, the relevance of mimicking natural proportions, and demonstrate that force-based metrics can provide practical performance estimates for soft burrowing robots.
- Open Access
- 25 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 19 (1) , 67-77
Perceived Intensity of Pneumatic Vibrotactile Stimuli: Effects of Pressure, Frequency, and Stiffness
Vibrotactile actuators are used in many different haptic devices, e.g. game controllers and smartphones. These vibrotactile actuators are typically made of rigid materials. In this paper, we use soft pneumatic actuators known as Pneumatic Unit Cell (PUC) to characterize the perceived intensity of vibrotactile stimuli when presented at the tip of the index finger. This study investigates how three parameters—stimulus pressure (4 to 30 kPa), inflation-deflation frequency (20 to 100 Hz), and actuator stiffness (determined by top layer thicknesses of 0.9 mm and 1.2 mm)—influence the perceptual intensity of the stimuli. Psychophysical experiments involving 16 participants were conducted using the AEPsych toolbox. These reveal that all the three parameters - pressure, frequency, and actuator stiffness significantly affect perceptual intensity. The findings indicate that both pressure and frequency exhibit a positive main effect and a positive interaction effect on perceived vibrotactile intensity. Additionally, the results show that, for a given frequency, pressure variations produce more perceptually distinct stimuli than frequency variations for a given pressure. Finally, presenting vibrotactile stimuli on a less stiff PUC actuator was perceived as being less intense than when the same stimulus was presented on a stiffer PUC actuator. Overall, this study provides key insights into the combined influence of pressure, frequency and actuator stiffness on the perceived vibrotactile intensity.
- 25 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 19 (1) , 67-77
Open AccessPerceived Intensity of Pneumatic Vibrotactile Stimuli: Effects of Pressure, Frequency, and Stiffness
Vibrotactile actuators are used in many different haptic devices, e.g. game controllers and smartphones. These vibrotactile actuators are typically made of rigid materials. In this paper, we use soft pneumatic actuators known as Pneumatic Unit Cell (PUC) to characterize the perceived intensity of vibrotactile stimuli when presented at the tip of the index finger. This study investigates how three parameters—stimulus pressure (4 to 30 kPa), inflation-deflation frequency (20 to 100 Hz), and actuator stiffness (determined by top layer thicknesses of 0.9 mm and 1.2 mm)—influence the perceptual intensity of the stimuli. Psychophysical experiments involving 16 participants were conducted using the AEPsych toolbox. These reveal that all the three parameters - pressure, frequency, and actuator stiffness significantly affect perceptual intensity. The findings indicate that both pressure and frequency exhibit a positive main effect and a positive interaction effect on perceived vibrotactile intensity. Additionally, the results show that, for a given frequency, pressure variations produce more perceptually distinct stimuli than frequency variations for a given pressure. Finally, presenting vibrotactile stimuli on a less stiff PUC actuator was perceived as being less intense than when the same stimulus was presented on a stiffer PUC actuator. Overall, this study provides key insights into the combined influence of pressure, frequency and actuator stiffness on the perceived vibrotactile intensity.
- Open Access
Fabrication and Characterization of Pneumatic Unit Cell Actuators
In the realm of virtual and augmented reality (VR/AR) and teleoperation applications, haptic feedback plays a role in enhancing task performance. One of the main goals of this study is to simplify haptic device hardware while improving its capacity to provide various stimuli at different intensities. In response to these challenges, this research introduces the Pneumatic Unit Cell (PUC), a soft pneumatically driven device—a hollow silicone cylinder with the ability to provide both static-pressure and vibrotactile feedback. Furthermore, the Pneumatic Unit Cell’s design simplicity has the potential for scalability, modularity, and the flexibility to mount the device on any part of the human body. The focus of the current paper is to study PUCs as actuators and lay the foundation for future perceptual studies. The characterization studies encompass the fabrication and verification of the fabrication accuracy through dimensional measurements, characterizing PUCs under static-pressure conditions (measuring the free deflection and blocking force) and frequency conditions (measuring the free deflection). In the static-pressure conditions, we applied pressures ranging from 0 to 40 kPa to measure the free deflection and from 0 to 30 kPa to measure the blocking force. In the frequency conditions, we applied pressures of 10, 20, and 30 kPa with inflation/deflation rates varying between 0.5 Hz and 100 Hz. The measurements of free deflection under static-pressure conditions revealed that 0.9 mm and 1.2 mm PUCs exhibit a linear increase in free deflection with an increase in inflation pressure. The results of free-deflection measurements under the frequency conditions indicate a direct relationship between the free-deflection magnitude and applied pressure. The results also demonstrate an inverse relationship to the frequency of inflation/deflation. The characterization results demonstrate a broad range of free deflection observed under both static-pressure and frequency conditions, encouraging the potential application of Pneumatic Unit Cell actuators as haptic devices.
Open AccessFabrication and Characterization of Pneumatic Unit Cell Actuators
In the realm of virtual and augmented reality (VR/AR) and teleoperation applications, haptic feedback plays a role in enhancing task performance. One of the main goals of this study is to simplify haptic device hardware while improving its capacity to provide various stimuli at different intensities. In response to these challenges, this research introduces the Pneumatic Unit Cell (PUC), a soft pneumatically driven device—a hollow silicone cylinder with the ability to provide both static-pressure and vibrotactile feedback. Furthermore, the Pneumatic Unit Cell’s design simplicity has the potential for scalability, modularity, and the flexibility to mount the device on any part of the human body. The focus of the current paper is to study PUCs as actuators and lay the foundation for future perceptual studies. The characterization studies encompass the fabrication and verification of the fabrication accuracy through dimensional measurements, characterizing PUCs under static-pressure conditions (measuring the free deflection and blocking force) and frequency conditions (measuring the free deflection). In the static-pressure conditions, we applied pressures ranging from 0 to 40 kPa to measure the free deflection and from 0 to 30 kPa to measure the blocking force. In the frequency conditions, we applied pressures of 10, 20, and 30 kPa with inflation/deflation rates varying between 0.5 Hz and 100 Hz. The measurements of free deflection under static-pressure conditions revealed that 0.9 mm and 1.2 mm PUCs exhibit a linear increase in free deflection with an increase in inflation pressure. The results of free-deflection measurements under the frequency conditions indicate a direct relationship between the free-deflection magnitude and applied pressure. The results also demonstrate an inverse relationship to the frequency of inflation/deflation. The characterization results demonstrate a broad range of free deflection observed under both static-pressure and frequency conditions, encouraging the potential application of Pneumatic Unit Cell actuators as haptic devices.
- Open Access
- 14 December 2023
- Published by MDPI AG in Preprints.org
Fabrication And Characterization Of Pneumatic Unit Cell Actuators
In the realm of virtual and augmented reality (VR/AR) and teleoperation applications, haptic feedback plays a role in enhancing task performance. One of the main goals of this study is to simplify haptic device hardware while improving its capacity to provide various stimuli at different intensities. In response to these challenges, this research introduces the Pneumatic Unit Cell (PUC), a soft-pneumatically driven device—a hollow silicone cylinder with the ability to provide both static pressure and vibrotactile feedback. Furthermore, Pneumatic Unit Cell's design simplicity has the potential for scalability, modularity, and the flexibility to mount the device on any part of the human body. The focus of the current paper is to study PUCs as an actuator and lay the foundation for future perceptual studies. The characterization studies encompass fabrication and verification of fabrication accuracy through dimensional measurements, characterizing PUCs under static pressure conditions (measuring free deflection and blocking force), and frequency conditions (measuring free deflection). In the static pressure conditions, we applied pressures ranging from 0 to 40 KPa to measure free deflection and from 0 to 30 KPa to measure blocking force. In the frequency conditions, we applied pressures of 10, 20, and 30 KPa, with inflation/deflation rates varying between 0.5 Hz and 100 Hz. The measurements of free deflection under static pressure conditions revealed that 0.9 mm and 1.2 mm PUCs exhibit a linear increase of free deflection with increase in inflation pressure. The results of free deflection measurements under the frequency conditions indicate a direct relationship between free deflection magnitude and applied pressure. The results also demonstrate an inverse relationship to the frequency of inflation/deflation. The characterization results demonstrate a broad range of free deflection observed under both static pressure and frequency conditions, encouraging the potential application of Pneumatic Unit Cell actuators as haptic devices.
- 14 December 2023
- Published by MDPI AG in Preprints.org
Open AccessFabrication And Characterization Of Pneumatic Unit Cell Actuators
In the realm of virtual and augmented reality (VR/AR) and teleoperation applications, haptic feedback plays a role in enhancing task performance. One of the main goals of this study is to simplify haptic device hardware while improving its capacity to provide various stimuli at different intensities. In response to these challenges, this research introduces the Pneumatic Unit Cell (PUC), a soft-pneumatically driven device—a hollow silicone cylinder with the ability to provide both static pressure and vibrotactile feedback. Furthermore, Pneumatic Unit Cell's design simplicity has the potential for scalability, modularity, and the flexibility to mount the device on any part of the human body. The focus of the current paper is to study PUCs as an actuator and lay the foundation for future perceptual studies. The characterization studies encompass fabrication and verification of fabrication accuracy through dimensional measurements, characterizing PUCs under static pressure conditions (measuring free deflection and blocking force), and frequency conditions (measuring free deflection). In the static pressure conditions, we applied pressures ranging from 0 to 40 KPa to measure free deflection and from 0 to 30 KPa to measure blocking force. In the frequency conditions, we applied pressures of 10, 20, and 30 KPa, with inflation/deflation rates varying between 0.5 Hz and 100 Hz. The measurements of free deflection under static pressure conditions revealed that 0.9 mm and 1.2 mm PUCs exhibit a linear increase of free deflection with increase in inflation pressure. The results of free deflection measurements under the frequency conditions indicate a direct relationship between free deflection magnitude and applied pressure. The results also demonstrate an inverse relationship to the frequency of inflation/deflation. The characterization results demonstrate a broad range of free deflection observed under both static pressure and frequency conditions, encouraging the potential application of Pneumatic Unit Cell actuators as haptic devices.
- 23 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 17 (2) , 191-201
Validation of a Soft Pneumatic Unit Cell (PUC) in a VR Experience: A Comparison Between Vibrotactile and Soft Pneumatic Haptic Feedback
Soft pneumatic displays have shown to provide compelling soft haptic feedback. However, they have rarely been tested in Virtual Reality applications, while we are interested in their potential for haptic feedback in the metaverse. Therefore, we designed a fully soft Pneumatic Unit Cell (PUC) and implemented it in a VR button task, in which users could directly use their hands for interaction. Twelve participants were asked to enter six-digit sequences, while being presented with PUC feedback, vibration feedback (VT), or no haptic feedback. Metrics on task performance, kinematics and cognitive load were collected. The results show that both vibration and PUC feedback resulted in participants pressing through the back of buttons less. The kinematic data showed that participants moved more smoothly during PUC feedback compared to vibration feedback. These effects were also reflected in the questionnaire data: participants felt more successful when using either PUCs or VTs, but they perceived the lowest level of stress when using PUCs. Feedback preference ratings also showed that PUC was the most preferred kind of feedback. Concluding, our array of metrics confirm that PUCs are good alternatives for haptic feedback in VR tasks in which electromechanical vibration motors typically excel: creating virtual button clicks.
- 23 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 17 (2) , 191-201
Validation of a Soft Pneumatic Unit Cell (PUC) in a VR Experience: A Comparison Between Vibrotactile and Soft Pneumatic Haptic Feedback
Soft pneumatic displays have shown to provide compelling soft haptic feedback. However, they have rarely been tested in Virtual Reality applications, while we are interested in their potential for haptic feedback in the metaverse. Therefore, we designed a fully soft Pneumatic Unit Cell (PUC) and implemented it in a VR button task, in which users could directly use their hands for interaction. Twelve participants were asked to enter six-digit sequences, while being presented with PUC feedback, vibration feedback (VT), or no haptic feedback. Metrics on task performance, kinematics and cognitive load were collected. The results show that both vibration and PUC feedback resulted in participants pressing through the back of buttons less. The kinematic data showed that participants moved more smoothly during PUC feedback compared to vibration feedback. These effects were also reflected in the questionnaire data: participants felt more successful when using either PUCs or VTs, but they perceived the lowest level of stress when using PUCs. Feedback preference ratings also showed that PUC was the most preferred kind of feedback. Concluding, our array of metrics confirm that PUCs are good alternatives for haptic feedback in VR tasks in which electromechanical vibration motors typically excel: creating virtual button clicks.
- Open Access
- 20 May 2022
- Published by Springer Nature
- p. 164-170
Haptic Feedback for Wrist Angle Adjustment
Haptic feedback is envisioned to be a powerful tool in (digital) orthosis fitment procedures. In context of a larger research project on digital molding and developing a glove for orthopedic experts, we explored the use of vibrotactile feedback on the wrist for wrist angle adjustments. Five different patterns are presented on both the inside and outside of the wrist as well as crossing signals. Participants were asked to indicate whether the pattern was communicating that the wrist angle had to be increased or decreased by moving the hand up or down. The results show that the vibrotactile stimuli are being interpreted consistently by the participants, provided the patterns are presented on one side of the arm. Although the interpretations were consistent within participants, there were individual differences in the reported directions of the signals, which makes it important to take into account personal preferences and calibration when implementing haptic feedback.
- 20 May 2022
- Published by Springer Nature
- p. 164-170
Open AccessHaptic Feedback for Wrist Angle Adjustment
Haptic feedback is envisioned to be a powerful tool in (digital) orthosis fitment procedures. In context of a larger research project on digital molding and developing a glove for orthopedic experts, we explored the use of vibrotactile feedback on the wrist for wrist angle adjustments. Five different patterns are presented on both the inside and outside of the wrist as well as crossing signals. Participants were asked to indicate whether the pattern was communicating that the wrist angle had to be increased or decreased by moving the hand up or down. The results show that the vibrotactile stimuli are being interpreted consistently by the participants, provided the patterns are presented on one side of the arm. Although the interpretations were consistent within participants, there were individual differences in the reported directions of the signals, which makes it important to take into account personal preferences and calibration when implementing haptic feedback.
- Open Access
- 20 May 2022
- Published by Springer Nature
- p. 101-109
A Comparison of Haptic and Auditory Feedback as a Warning Signal for Slip in Tele-Operation Scenarios
Slip feedback is an important cue in everyday object manipulation, but it is generally missing in tele-operation systems. To test the usefulness of simple, abstract types of feedback that warn the user about slip events, we tested the effect of auditory and haptic vibration feedback in a tele-operation task. Participants were asked to hold an object in a remote robot hand, and the force profiles that they exerted in response to slip events were measured. Haptic feedback did not significantly change the response characteristics, but auditory feedback did significantly improve response latency. A small but significant difference between haptic and auditory reaction times (60 ms) found in our control experiment might explain the difference between the feedback types.
- 20 May 2022
- Published by Springer Nature
- p. 101-109
Open AccessA Comparison of Haptic and Auditory Feedback as a Warning Signal for Slip in Tele-Operation Scenarios
Slip feedback is an important cue in everyday object manipulation, but it is generally missing in tele-operation systems. To test the usefulness of simple, abstract types of feedback that warn the user about slip events, we tested the effect of auditory and haptic vibration feedback in a tele-operation task. Participants were asked to hold an object in a remote robot hand, and the force profiles that they exerted in response to slip events were measured. Haptic feedback did not significantly change the response characteristics, but auditory feedback did significantly improve response latency. A small but significant difference between haptic and auditory reaction times (60 ms) found in our control experiment might explain the difference between the feedback types.
- 15 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 14 (1) , 20-31
Static Weight Perception Through Skin Stretch and Kinesthetic Information: Detection Thresholds, JNDs, and PSEs
We examined the contributions of kinesthetic and skin stretch cues to static weight perception. In three psychophysical experiments, several aspects of static weight perception were assessed by asking participants either to detect on which hand a weight was presented or to compare between two weight cues. Two closed-loop controlled haptic devices were used to present cutaneous and kinesthetic weights, in isolation and together, with a precision of 0.05g. Our results show that combining skin stretch and kinesthetic information leads to better weight detection thresholds than presenting uni-sensory cues does. For supra-threshold stimuli, Weber fractions were 22-44%. Kinesthetic information was less reliable for lighter weights, while both sources of information were equally reliable for weights up to 300g. Weight was perceived as equally heavy regardless of whether skin stretch and kinesthetic cues were presented together or alone. Data for lighter weights complied with an Optimal Integration model, while for heavier weights, measurements were closer to predictions from a Sensory Capture model. The presence of correlated noise might explain this discrepancy, since that would shift predictions from the Optimal Integration model towards our measurements. Our experiments provide device-independent perceptual measures, and can be used to inform, for instance, skin stretch device design.
- 15 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 14 (1) , 20-31
Static Weight Perception Through Skin Stretch and Kinesthetic Information: Detection Thresholds, JNDs, and PSEs
We examined the contributions of kinesthetic and skin stretch cues to static weight perception. In three psychophysical experiments, several aspects of static weight perception were assessed by asking participants either to detect on which hand a weight was presented or to compare between two weight cues. Two closed-loop controlled haptic devices were used to present cutaneous and kinesthetic weights, in isolation and together, with a precision of 0.05g. Our results show that combining skin stretch and kinesthetic information leads to better weight detection thresholds than presenting uni-sensory cues does. For supra-threshold stimuli, Weber fractions were 22-44%. Kinesthetic information was less reliable for lighter weights, while both sources of information were equally reliable for weights up to 300g. Weight was perceived as equally heavy regardless of whether skin stretch and kinesthetic cues were presented together or alone. Data for lighter weights complied with an Optimal Integration model, while for heavier weights, measurements were closer to predictions from a Sensory Capture model. The presence of correlated noise might explain this discrepancy, since that would shift predictions from the Optimal Integration model towards our measurements. Our experiments provide device-independent perceptual measures, and can be used to inform, for instance, skin stretch device design.
- Open Access
- 23 July 2016
- Published by Springer Nature in Experimental Brain Research
- Vol. 234 (11) , 3367-3379
Integrating force and position: testing model predictions
In this study, we investigated the integration of force and position information in a task in which participants were asked to estimate the center of a weak force field. Two hypotheses, describing how participants solved this task, were tested: (1) by only using the position(s) where the force reaches the detection threshold, and (2) by extrapolating the force field based on perceived stiffness. Both hypotheses were also described formally, assuming a psychophysical function obeying a power law with an exponent smaller than one. The hypotheses were tested in two psychophysical experiments, in which 12 participants took part. In Experiment 1, an asymmetric force field was used and the presence of visual feedback about hand position was varied. In Experiment 2, a unilateral force field was used. For both experiments, hypothesis 1 predicts biases between (Experiment 1) or at (Experiment 2) the position(s) of the force detection threshold, while hypothesis 2 predicts smaller biases. The measured data show significant biases in both experiments that coincide with the biases predicted by using force detection thresholds from the literature. The average measured responses and their variabilities also fitted very well with the mathematical model of hypothesis 1. These results underline the validity of hypothesis 1. So, participants did not use a percept of the stiffness of the force field, but based their estimation of the center of the force field on the position(s) where the force reached the detection threshold. This shows that force and position information were not integrated in this task.
- 23 July 2016
- Published by Springer Nature in Experimental Brain Research
- Vol. 234 (11) , 3367-3379
Open AccessIntegrating force and position: testing model predictions
In this study, we investigated the integration of force and position information in a task in which participants were asked to estimate the center of a weak force field. Two hypotheses, describing how participants solved this task, were tested: (1) by only using the position(s) where the force reaches the detection threshold, and (2) by extrapolating the force field based on perceived stiffness. Both hypotheses were also described formally, assuming a psychophysical function obeying a power law with an exponent smaller than one. The hypotheses were tested in two psychophysical experiments, in which 12 participants took part. In Experiment 1, an asymmetric force field was used and the presence of visual feedback about hand position was varied. In Experiment 2, a unilateral force field was used. For both experiments, hypothesis 1 predicts biases between (Experiment 1) or at (Experiment 2) the position(s) of the force detection threshold, while hypothesis 2 predicts smaller biases. The measured data show significant biases in both experiments that coincide with the biases predicted by using force detection thresholds from the literature. The average measured responses and their variabilities also fitted very well with the mathematical model of hypothesis 1. These results underline the validity of hypothesis 1. So, participants did not use a percept of the stiffness of the force field, but based their estimation of the center of the force field on the position(s) where the force reached the detection threshold. This shows that force and position information were not integrated in this task.
- Open Access
- 20 July 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (7) , e0158709
Correcting for Visuo-Haptic Biases in 3D Haptic Guidance
Visuo-haptic biases are observed when bringing your unseen hand to a visual target. The biases are different between, but consistent within participants. We investigated the usefulness of adjusting haptic guidance to these user-specific biases in aligning haptic and visual perception. By adjusting haptic guidance according to the biases, we aimed to reduce the conflict between the modalities. We first measured the biases using an adaptive procedure. Next, we measured performance in a pointing task using three conditions: 1) visual images that were adjusted to user-specific biases, without haptic guidance, 2) veridical visual images combined with haptic guidance, and 3) shifted visual images combined with haptic guidance. Adding haptic guidance increased precision. Combining haptic guidance with user-specific visual information yielded the highest accuracy and the lowest level of conflict with the guidance at the end point. These results show the potential of correcting for user-specific perceptual biases when designing haptic guidance.
- 20 July 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (7) , e0158709
Open AccessCorrecting for Visuo-Haptic Biases in 3D Haptic Guidance
Visuo-haptic biases are observed when bringing your unseen hand to a visual target. The biases are different between, but consistent within participants. We investigated the usefulness of adjusting haptic guidance to these user-specific biases in aligning haptic and visual perception. By adjusting haptic guidance according to the biases, we aimed to reduce the conflict between the modalities. We first measured the biases using an adaptive procedure. Next, we measured performance in a pointing task using three conditions: 1) visual images that were adjusted to user-specific biases, without haptic guidance, 2) veridical visual images combined with haptic guidance, and 3) shifted visual images combined with haptic guidance. Adding haptic guidance increased precision. Combining haptic guidance with user-specific visual information yielded the highest accuracy and the lowest level of conflict with the guidance at the end point. These results show the potential of correcting for user-specific perceptual biases when designing haptic guidance.