Krishna Dheeraj Kommuri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Krishna Dheeraj Kommuri has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Irene A. Kuling
Eindhoven University of Technology
5 shared publications - Femke E. van Beek
Reshape Lab, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
3 shared publications - Changpei Ou
Eindhoven University of Technology
1 shared publication - Lucas P.V. Beeks
Eindhoven University of Technology
1 shared publication - Mehmet Ege Cansev
Chair of Autonomous Systems and Mechatronics, Department of Electrical Engineering, Friedrich-Alexander-Universitt Erlangen-Nrnberg, Erlangen, Germany
1 shared publication - Myrthe A. Plaisier
Eindhoven University of Technology
1 shared publication
Latest Publications
- 28 July 2026
- Published by Springer Nature
- p. 126-135
Apparent Motion Induced with Soft Pneumatic Actuators
- 28 July 2026
- Published by Springer Nature
- p. 126-135
Apparent Motion Induced with Soft Pneumatic Actuators
- Open Access
- 25 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 19 (1) , 67-77
Perceived Intensity of Pneumatic Vibrotactile Stimuli: Effects of Pressure, Frequency, and Stiffness
Vibrotactile actuators are used in many different haptic devices, e.g. game controllers and smartphones. These vibrotactile actuators are typically made of rigid materials. In this paper, we use soft pneumatic actuators known as Pneumatic Unit Cell (PUC) to characterize the perceived intensity of vibrotactile stimuli when presented at the tip of the index finger. This study investigates how three parameters—stimulus pressure (4 to 30 kPa), inflation-deflation frequency (20 to 100 Hz), and actuator stiffness (determined by top layer thicknesses of 0.9 mm and 1.2 mm)—influence the perceptual intensity of the stimuli. Psychophysical experiments involving 16 participants were conducted using the AEPsych toolbox. These reveal that all the three parameters - pressure, frequency, and actuator stiffness significantly affect perceptual intensity. The findings indicate that both pressure and frequency exhibit a positive main effect and a positive interaction effect on perceived vibrotactile intensity. Additionally, the results show that, for a given frequency, pressure variations produce more perceptually distinct stimuli than frequency variations for a given pressure. Finally, presenting vibrotactile stimuli on a less stiff PUC actuator was perceived as being less intense than when the same stimulus was presented on a stiffer PUC actuator. Overall, this study provides key insights into the combined influence of pressure, frequency and actuator stiffness on the perceived vibrotactile intensity.
- 25 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 19 (1) , 67-77
Open AccessPerceived Intensity of Pneumatic Vibrotactile Stimuli: Effects of Pressure, Frequency, and Stiffness
Vibrotactile actuators are used in many different haptic devices, e.g. game controllers and smartphones. These vibrotactile actuators are typically made of rigid materials. In this paper, we use soft pneumatic actuators known as Pneumatic Unit Cell (PUC) to characterize the perceived intensity of vibrotactile stimuli when presented at the tip of the index finger. This study investigates how three parameters—stimulus pressure (4 to 30 kPa), inflation-deflation frequency (20 to 100 Hz), and actuator stiffness (determined by top layer thicknesses of 0.9 mm and 1.2 mm)—influence the perceptual intensity of the stimuli. Psychophysical experiments involving 16 participants were conducted using the AEPsych toolbox. These reveal that all the three parameters - pressure, frequency, and actuator stiffness significantly affect perceptual intensity. The findings indicate that both pressure and frequency exhibit a positive main effect and a positive interaction effect on perceived vibrotactile intensity. Additionally, the results show that, for a given frequency, pressure variations produce more perceptually distinct stimuli than frequency variations for a given pressure. Finally, presenting vibrotactile stimuli on a less stiff PUC actuator was perceived as being less intense than when the same stimulus was presented on a stiffer PUC actuator. Overall, this study provides key insights into the combined influence of pressure, frequency and actuator stiffness on the perceived vibrotactile intensity.
- Open Access
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (4) , 901-910
Rendering Affective Touch With an Array of Pneumatic Unit Cell Actuators
Rendering affective touch through haptic interfaces has gathered significant interest due to its ability to elicit emotional responses. Among various forms of affective touch, this study focuses on stroke stimuli. An illusory stroke stimulus is rendered using eight discrete Pneumatic Unit Cell (PUC) actuators on the left forearm. The study systematically investigates how rendering parameters—including the traveling speed of the illusory stroke, the stimulus onset asynchrony (SOA) of consecutive indentations, and indentation pressure—affect the perceived pleasantness and continuity of the stimulus. Results reveal that higher speeds significantly improved both pleasantness and continuity, with speed emerging as the most influential factor. In contrast, SOA has no significant effect on either perceived pleasantness or continuity. Indentation pressure shows a moderate impact on pleasantness, with high pressures reducing pleasantness but having no significant effect on continuity. Additionally, a positive correlation is observed between perceived pleasantness and continuity, underscoring the relevance of the continuity illusion created by sequential indentations with discrete actuators in evoking pleasant sensations. These findings demonstrate the potential of PUC actuators for creating affective touch stimuli and provide preliminary insights into the influence of rendering parameters on affective touch in human-machine and human-robot interactions.
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (4) , 901-910
Open AccessRendering Affective Touch With an Array of Pneumatic Unit Cell Actuators
Rendering affective touch through haptic interfaces has gathered significant interest due to its ability to elicit emotional responses. Among various forms of affective touch, this study focuses on stroke stimuli. An illusory stroke stimulus is rendered using eight discrete Pneumatic Unit Cell (PUC) actuators on the left forearm. The study systematically investigates how rendering parameters—including the traveling speed of the illusory stroke, the stimulus onset asynchrony (SOA) of consecutive indentations, and indentation pressure—affect the perceived pleasantness and continuity of the stimulus. Results reveal that higher speeds significantly improved both pleasantness and continuity, with speed emerging as the most influential factor. In contrast, SOA has no significant effect on either perceived pleasantness or continuity. Indentation pressure shows a moderate impact on pleasantness, with high pressures reducing pleasantness but having no significant effect on continuity. Additionally, a positive correlation is observed between perceived pleasantness and continuity, underscoring the relevance of the continuity illusion created by sequential indentations with discrete actuators in evoking pleasant sensations. These findings demonstrate the potential of PUC actuators for creating affective touch stimuli and provide preliminary insights into the influence of rendering parameters on affective touch in human-machine and human-robot interactions.
- Open Access
Fabrication and Characterization of Pneumatic Unit Cell Actuators
In the realm of virtual and augmented reality (VR/AR) and teleoperation applications, haptic feedback plays a role in enhancing task performance. One of the main goals of this study is to simplify haptic device hardware while improving its capacity to provide various stimuli at different intensities. In response to these challenges, this research introduces the Pneumatic Unit Cell (PUC), a soft pneumatically driven device—a hollow silicone cylinder with the ability to provide both static-pressure and vibrotactile feedback. Furthermore, the Pneumatic Unit Cell’s design simplicity has the potential for scalability, modularity, and the flexibility to mount the device on any part of the human body. The focus of the current paper is to study PUCs as actuators and lay the foundation for future perceptual studies. The characterization studies encompass the fabrication and verification of the fabrication accuracy through dimensional measurements, characterizing PUCs under static-pressure conditions (measuring the free deflection and blocking force) and frequency conditions (measuring the free deflection). In the static-pressure conditions, we applied pressures ranging from 0 to 40 kPa to measure the free deflection and from 0 to 30 kPa to measure the blocking force. In the frequency conditions, we applied pressures of 10, 20, and 30 kPa with inflation/deflation rates varying between 0.5 Hz and 100 Hz. The measurements of free deflection under static-pressure conditions revealed that 0.9 mm and 1.2 mm PUCs exhibit a linear increase in free deflection with an increase in inflation pressure. The results of free-deflection measurements under the frequency conditions indicate a direct relationship between the free-deflection magnitude and applied pressure. The results also demonstrate an inverse relationship to the frequency of inflation/deflation. The characterization results demonstrate a broad range of free deflection observed under both static-pressure and frequency conditions, encouraging the potential application of Pneumatic Unit Cell actuators as haptic devices.
Open AccessFabrication and Characterization of Pneumatic Unit Cell Actuators
In the realm of virtual and augmented reality (VR/AR) and teleoperation applications, haptic feedback plays a role in enhancing task performance. One of the main goals of this study is to simplify haptic device hardware while improving its capacity to provide various stimuli at different intensities. In response to these challenges, this research introduces the Pneumatic Unit Cell (PUC), a soft pneumatically driven device—a hollow silicone cylinder with the ability to provide both static-pressure and vibrotactile feedback. Furthermore, the Pneumatic Unit Cell’s design simplicity has the potential for scalability, modularity, and the flexibility to mount the device on any part of the human body. The focus of the current paper is to study PUCs as actuators and lay the foundation for future perceptual studies. The characterization studies encompass the fabrication and verification of the fabrication accuracy through dimensional measurements, characterizing PUCs under static-pressure conditions (measuring the free deflection and blocking force) and frequency conditions (measuring the free deflection). In the static-pressure conditions, we applied pressures ranging from 0 to 40 kPa to measure the free deflection and from 0 to 30 kPa to measure the blocking force. In the frequency conditions, we applied pressures of 10, 20, and 30 kPa with inflation/deflation rates varying between 0.5 Hz and 100 Hz. The measurements of free deflection under static-pressure conditions revealed that 0.9 mm and 1.2 mm PUCs exhibit a linear increase in free deflection with an increase in inflation pressure. The results of free-deflection measurements under the frequency conditions indicate a direct relationship between the free-deflection magnitude and applied pressure. The results also demonstrate an inverse relationship to the frequency of inflation/deflation. The characterization results demonstrate a broad range of free deflection observed under both static-pressure and frequency conditions, encouraging the potential application of Pneumatic Unit Cell actuators as haptic devices.
- Open Access
- 14 December 2023
- Published by MDPI AG in Preprints.org
Fabrication And Characterization Of Pneumatic Unit Cell Actuators
In the realm of virtual and augmented reality (VR/AR) and teleoperation applications, haptic feedback plays a role in enhancing task performance. One of the main goals of this study is to simplify haptic device hardware while improving its capacity to provide various stimuli at different intensities. In response to these challenges, this research introduces the Pneumatic Unit Cell (PUC), a soft-pneumatically driven device—a hollow silicone cylinder with the ability to provide both static pressure and vibrotactile feedback. Furthermore, Pneumatic Unit Cell's design simplicity has the potential for scalability, modularity, and the flexibility to mount the device on any part of the human body. The focus of the current paper is to study PUCs as an actuator and lay the foundation for future perceptual studies. The characterization studies encompass fabrication and verification of fabrication accuracy through dimensional measurements, characterizing PUCs under static pressure conditions (measuring free deflection and blocking force), and frequency conditions (measuring free deflection). In the static pressure conditions, we applied pressures ranging from 0 to 40 KPa to measure free deflection and from 0 to 30 KPa to measure blocking force. In the frequency conditions, we applied pressures of 10, 20, and 30 KPa, with inflation/deflation rates varying between 0.5 Hz and 100 Hz. The measurements of free deflection under static pressure conditions revealed that 0.9 mm and 1.2 mm PUCs exhibit a linear increase of free deflection with increase in inflation pressure. The results of free deflection measurements under the frequency conditions indicate a direct relationship between free deflection magnitude and applied pressure. The results also demonstrate an inverse relationship to the frequency of inflation/deflation. The characterization results demonstrate a broad range of free deflection observed under both static pressure and frequency conditions, encouraging the potential application of Pneumatic Unit Cell actuators as haptic devices.
- 14 December 2023
- Published by MDPI AG in Preprints.org
Open AccessFabrication And Characterization Of Pneumatic Unit Cell Actuators
In the realm of virtual and augmented reality (VR/AR) and teleoperation applications, haptic feedback plays a role in enhancing task performance. One of the main goals of this study is to simplify haptic device hardware while improving its capacity to provide various stimuli at different intensities. In response to these challenges, this research introduces the Pneumatic Unit Cell (PUC), a soft-pneumatically driven device—a hollow silicone cylinder with the ability to provide both static pressure and vibrotactile feedback. Furthermore, Pneumatic Unit Cell's design simplicity has the potential for scalability, modularity, and the flexibility to mount the device on any part of the human body. The focus of the current paper is to study PUCs as an actuator and lay the foundation for future perceptual studies. The characterization studies encompass fabrication and verification of fabrication accuracy through dimensional measurements, characterizing PUCs under static pressure conditions (measuring free deflection and blocking force), and frequency conditions (measuring free deflection). In the static pressure conditions, we applied pressures ranging from 0 to 40 KPa to measure free deflection and from 0 to 30 KPa to measure blocking force. In the frequency conditions, we applied pressures of 10, 20, and 30 KPa, with inflation/deflation rates varying between 0.5 Hz and 100 Hz. The measurements of free deflection under static pressure conditions revealed that 0.9 mm and 1.2 mm PUCs exhibit a linear increase of free deflection with increase in inflation pressure. The results of free deflection measurements under the frequency conditions indicate a direct relationship between free deflection magnitude and applied pressure. The results also demonstrate an inverse relationship to the frequency of inflation/deflation. The characterization results demonstrate a broad range of free deflection observed under both static pressure and frequency conditions, encouraging the potential application of Pneumatic Unit Cell actuators as haptic devices.