Ryouji Doihara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ryouji Doihara has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Takashi Shimada
National Institute of Advanced Industrial Science and Technology Ibaraki, Tsukuba, JAPAN
12 shared publications- Kar-Hooi Cheong
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, JAPAN
7 shared publications - Yoshiya Terao
National Institute of Advanced Industrial Science and Technology
7 shared publications Masaki Takamoto
5 shared publicationsYoshiya Terao
4 shared publicationsKazuhide Takeda
2 shared publications
Latest Publications
- Open Access
- 23 August 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8421
Optimum Pressurization Mechanism for a Non-Electrical Piston-Driven Infusion Pump
Intravenous (IV) fluid therapy is a common current medical practice, and the method has remained unchanged for more than a century. The IV bag is suspended from an IV stand or pole, and the pressure created by gravity is used to administer the drug. However, this method inevitably reduces the mobility of patients, and may cause accidents such as falls during movement. To solve these problems faced in home care, nursing home, and hospital settings, this study aims to develop a non-hanging, non-electrically driven IV infusion pump with reasonable portability and operability. In this study, instead of gravity, atmospheric pressure was used as the driving force. We developed several prototypes based on different pressurization mechanisms using vacuum piston cylinders as the driving mechanism, in order to find an optimum mechanism capable of producing a stable flow rate comparable to the suspended drip system. Tests on performance in terms of discharge flow rate were conducted on three feasible prototypes, based on three different pressurization mechanisms, using a gravimetric test bench built for this purpose. The tests showed that the pressurization mechanism using an inflating sleeping-bag-shaped air bag to compress a drip bag achieved the best performance in terms of flow rate stability.
- 23 August 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8421
Open AccessOptimum Pressurization Mechanism for a Non-Electrical Piston-Driven Infusion Pump
Intravenous (IV) fluid therapy is a common current medical practice, and the method has remained unchanged for more than a century. The IV bag is suspended from an IV stand or pole, and the pressure created by gravity is used to administer the drug. However, this method inevitably reduces the mobility of patients, and may cause accidents such as falls during movement. To solve these problems faced in home care, nursing home, and hospital settings, this study aims to develop a non-hanging, non-electrically driven IV infusion pump with reasonable portability and operability. In this study, instead of gravity, atmospheric pressure was used as the driving force. We developed several prototypes based on different pressurization mechanisms using vacuum piston cylinders as the driving mechanism, in order to find an optimum mechanism capable of producing a stable flow rate comparable to the suspended drip system. Tests on performance in terms of discharge flow rate were conducted on three feasible prototypes, based on three different pressurization mechanisms, using a gravimetric test bench built for this purpose. The tests showed that the pressurization mechanism using an inflating sleeping-bag-shaped air bag to compress a drip bag achieved the best performance in terms of flow rate stability.
- 19 October 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (6) , 065003
Primary standard for traceability in low liquid hydrocarbon fuel flow rates
We developed a primary standard for low liquid hydrocarbon flow rates that works on light oil (diesel), kerosene and industrial gasoline. To achieve a calibration accuracy of below 0.1% over a wide flow range from 0.02 L h −1 to 100 L h −1 as required by the industry, this primary standard adopts the gravimetric calibration method performing static weighing with flying-start-and-finish, incorporating a compactly designed conical rotating double-wing diverter for the upper flow range (1 L h −1 to 100 L h −1 ) and a pair of high-speed switching valves as a diverter for the lower flow range (0.02 L h −1 to 6 L h −1 ). The uncertainty of liquid mass measurement (in which the evaporation error is a dominant factor) as well as the uncertainty of liquid collection time (in which the diverter timing error is a major factor) are minimized to a level that curbs their dominance to the overall mass flow uncertainty. On the other hand, the uncertainty due to the estimation of liquid density at the flowmeter under test, which is a significant contributing factor to the overall uncertainty of volumetric flow, is being reduced by temperature control measures through a self-developed thermostatic chamber. Intra-facility and inter-facility comparisons within NMIJ were performed, all showing a good agreement, and hence providing supporting evidence for the calibration and measurement capability (CMC), which are 0.020%–0.044% for the mass flow rates and 0.044%–0.066% for the volumetric flow rates as claimed by the facility.
- 19 October 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (6) , 065003
Primary standard for traceability in low liquid hydrocarbon fuel flow rates
We developed a primary standard for low liquid hydrocarbon flow rates that works on light oil (diesel), kerosene and industrial gasoline. To achieve a calibration accuracy of below 0.1% over a wide flow range from 0.02 L h −1 to 100 L h −1 as required by the industry, this primary standard adopts the gravimetric calibration method performing static weighing with flying-start-and-finish, incorporating a compactly designed conical rotating double-wing diverter for the upper flow range (1 L h −1 to 100 L h −1 ) and a pair of high-speed switching valves as a diverter for the lower flow range (0.02 L h −1 to 6 L h −1 ). The uncertainty of liquid mass measurement (in which the evaporation error is a dominant factor) as well as the uncertainty of liquid collection time (in which the diverter timing error is a major factor) are minimized to a level that curbs their dominance to the overall mass flow uncertainty. On the other hand, the uncertainty due to the estimation of liquid density at the flowmeter under test, which is a significant contributing factor to the overall uncertainty of volumetric flow, is being reduced by temperature control measures through a self-developed thermostatic chamber. Intra-facility and inter-facility comparisons within NMIJ were performed, all showing a good agreement, and hence providing supporting evidence for the calibration and measurement capability (CMC), which are 0.020%–0.044% for the mass flow rates and 0.044%–0.066% for the volumetric flow rates as claimed by the facility.
- 1 October 2021
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 81
Weighing system with low evaporation error for liquid microflow down to 1 mg/min
- 1 October 2021
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 81
Weighing system with low evaporation error for liquid microflow down to 1 mg/min
- 30 March 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (3) , 262-279
Evaluation of hydrocarbon flow standard facility equipped with double-wing diverter using four types of working liquids
A flow calibration facility based on the gravimetric method using a double-wing diverter for hydrocarbon flows from 0.1 m 3 h −1 to 15 m 3 h −1 was constructed as a national measurement standard in Japan. The original working liquids were kerosene and light oil. The calibration facility was modified to calibrate flowmeters with two additional working liquids, industrial gasoline (flash point > 40 °C) and spindle oil, to achieve calibration over a wide viscosity range at the same calibration test rig. The kinematic viscosity range is 1.2 mm 2 s −1 to 24 mm 2 s −1 . The contributions to the measurement uncertainty due to different types of working liquids were evaluated experimentally in this study. The evaporation error was reduced by using a seal system at the weighing tank inlet. The uncertainty due to droplets from the diverter wings was reduced by a modified diverter operation. The diverter timing errors for all types of working liquids were estimated. The expanded uncertainties for the calibration facility were estimated to be 0.020% for mass flow and 0.030% for volumetric flow for all considered types of liquids. Internal comparisons with other calibration facilities were also conducted, and the agreement was confirmed to be within the claimed expanded uncertainties.
- 30 March 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (3) , 262-279
Evaluation of hydrocarbon flow standard facility equipped with double-wing diverter using four types of working liquids
A flow calibration facility based on the gravimetric method using a double-wing diverter for hydrocarbon flows from 0.1 m 3 h −1 to 15 m 3 h −1 was constructed as a national measurement standard in Japan. The original working liquids were kerosene and light oil. The calibration facility was modified to calibrate flowmeters with two additional working liquids, industrial gasoline (flash point > 40 °C) and spindle oil, to achieve calibration over a wide viscosity range at the same calibration test rig. The kinematic viscosity range is 1.2 mm 2 s −1 to 24 mm 2 s −1 . The contributions to the measurement uncertainty due to different types of working liquids were evaluated experimentally in this study. The evaporation error was reduced by using a seal system at the weighing tank inlet. The uncertainty due to droplets from the diverter wings was reduced by a modified diverter operation. The diverter timing errors for all types of working liquids were estimated. The expanded uncertainties for the calibration facility were estimated to be 0.020% for mass flow and 0.030% for volumetric flow for all considered types of liquids. Internal comparisons with other calibration facilities were also conducted, and the agreement was confirmed to be within the claimed expanded uncertainties.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Symposium on Micro-Nano Science and Technology
- Vol. 2017.8, PN-110-110
Evaluation of high-speed switching valves implemented in low liquid calibration system
Static gravimetric method with flying start-and-finish is widely used for calibration of large and medium liquid flow for its advantage of maintaining continuous flow through the flowmeter. However one needs to take careful measures in implementing this method in low flow systems to obtain good accuracy. At NMIJ/AIST, we adopted this calibration method using a pair of high speed switching valves as diverter for flow range below 1 L/h. This paper discusses the timing error of the diverting valves evaluated according to ISO4185 and also describes some of the main features of the gravimetric system using this high-speed switching valves.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Symposium on Micro-Nano Science and Technology
- Vol. 2017.8, PN-110-110
Evaluation of high-speed switching valves implemented in low liquid calibration system
Static gravimetric method with flying start-and-finish is widely used for calibration of large and medium liquid flow for its advantage of maintaining continuous flow through the flowmeter. However one needs to take careful measures in implementing this method in low flow systems to obtain good accuracy. At NMIJ/AIST, we adopted this calibration method using a pair of high speed switching valves as diverter for flow range below 1 L/h. This paper discusses the timing error of the diverting valves evaluated according to ISO4185 and also describes some of the main features of the gravimetric system using this high-speed switching valves.
- 1 August 2016
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 50, 90-101
Liquid low-flow calibration rig using syringe pump and weighing tank system
- 1 August 2016
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 50, 90-101
Liquid low-flow calibration rig using syringe pump and weighing tank system
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2016, G0500403
Calibration of a Large Ball Prover for Hydrocarbon Flow by Using Flowmeters
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2016, G0500403
Calibration of a Large Ball Prover for Hydrocarbon Flow by Using Flowmeters
- 1 March 2015
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 41, 174-180
Investigation into calibration performance of small volume prover for hydrocarbon flow
- 1 March 2015
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 41, 174-180
Investigation into calibration performance of small volume prover for hydrocarbon flow
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2012, _G050034-1
G050034 Development of Flow Subtraction Method of Calibrating Flowmeters for Liquids
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2012, _G050034-1
G050034 Development of Flow Subtraction Method of Calibrating Flowmeters for Liquids