Optimum Pressurization Mechanism for a Non-Electrical Piston-Driven Infusion Pump
Authors:
- Kar-Hooi CheongKCKar-Hooi Cheong
- Ryouji DoiharaRDRyouji Doihara
- Noriyuki FuruichiNFNoriyuki Furuichi
- Masaharu NakagawaMNMasaharu Nakagawa
- Ruriko KarasawaRKRuriko Karasawa
- Yoshihiro KatoYKYoshihiro Kato
- Kazunori KageyamaKKKazunori Kageyama
- Takuro AkasakaTATakuro Akasaka
- Yuki OnumaYOYuki Onuma
- Takashi KatoTKTakashi Kato
Open Access
- 23 August 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8421
Abstract
Intravenous (IV) fluid therapy is a common current medical practice, and the method has remained unchanged for more than a century. The IV bag is suspended from an IV stand or pole, and the pressure created by gravity is used to administer the drug. However, this method inevitably reduces the mobility of patients, and may cause accidents such as falls during movement. To solve these problems faced in home care, nursing home, and hospital settings, this study aims to develop a non-hanging, non-electrically driven IV infusion pump with reasonable portability and operability. In this study, instead of gravity, atmospheric pressure was used as the driving force. We developed several prototypes based on different pressurization mechanisms using vacuum piston cylinders as the driving mechanism, in order to find an optimum mechanism capable of producing a stable flow rate comparable to the suspended drip system. Tests on performance in terms of discharge flow rate were conducted on three feasible prototypes, based on three different pressurization mechanisms, using a gravimetric test bench built for this purpose. The tests showed that the pressurization mechanism using an inflating sleeping-bag-shaped air bag to compress a drip bag achieved the best performance in terms of flow rate stability.Keywords
Funding Information
- Japanese Ministry of Economy, Trade and Industry (FY2018-2019)
This publication has 30 references indexed in Scilit:
- Is the Drip-and-Ship Approach to Delivering Thrombolysis for Acute Ischemic Stroke Safe?The Journal of Emergency Medicine, 2011
- A review of return to sport concerns following injury rehabilitation: Practitioner strategies for enhancing recovery outcomesPhysical Therapy in Sport, 2011
- Design considerations and initial validation of a liquid microflow calibration setup using parallel operated syringe pumpsMeasurement Science and Technology, 2010
- Continuous subcutaneous delivery of medications for home care palliative patients—using an infusion set or a pump?Supportive Care in Cancer, 2009
- Intermittent Bolus Dosing of Lidocaine in Emergency Medical Services—An Alternative to Bolus Followed by a DripPrehospital Emergency Care, 2006
- Rehydration in palliative and terminal care: if not- why not?Palliative Medicine, 1995
- A NOTE ON PRE-OPERATIVE PREPARATION OF CASES WITH GRAVE INTRA-ABDOMINAL HAEMORRHAGESBMJ, 1935
- SALINE VENOUS INJECTION IN CASES OF MALIGNANT CHOLERA, PERFORMED WHILE IN THE VAPOUR-BATH.The Lancet, 1832
- NOTE FROM DR. LATTA.The Lancet, 1832
- OBSERVATIONS ON TRANSFUSION OF BLOOD.The Lancet, 1829