Aurélien Bricout
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aurélien Bricout has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Alborz Rezazadeh Sereshkeh
University of Toronto Institute of Biomaterials and Biomedical Engineering, Toronto, Ontario, CANADA
1 shared publication - Arnaud Gotlieb
Simula Research Laboratory, Norway
1 shared publication - Clotilde Braye
Enovacom, Paris, France
1 shared publication Jean-Louis Pépin
HP2 Laboratory, INSERM U1042, Grenoble Alpes University, Grenoble, France
1 shared publication- Julie Fontecave-Jallon
Univ. Grenoble Alpes, CNRS, CHU Grenoble Alpes, Grenoble INP, TIMC-IMAG, La Tronche, France
1 shared publication - Nadjib Lazaar
LIRMM, University of Montpellier, CNRS, Montpellier, France
1 shared publication
Latest Publications
- Open Access
- 23 March 2026
- Published by Association for Computing Machinery (ACM)
- p. 978-979
Optimizing Ethical Risk Reduction for Medical Intelligent Systems with Constraint Programming
- 23 March 2026
- Published by Association for Computing Machinery (ACM)
- p. 978-979
Open AccessOptimizing Ethical Risk Reduction for Medical Intelligent Systems with Constraint Programming
- 1 August 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 207, 106209
Accelerometry-derived respiratory index estimating apnea-hypopnea index for sleep apnea screening
- 1 August 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 207, 106209
Accelerometry-derived respiratory index estimating apnea-hypopnea index for sleep apnea screening
- 23 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ACM Transactions on Audio, Speech, and Language Processing
- Vol. 25 (12) , 2292-2300
EEG Classification of Covert Speech Using Regularized Neural Networks
Communication using brain-computer interfaces (BCIs) can be non-intuitive, often requiring the performance of a conversation-irrelevant task such as hand motor imagery. In this paper, the reliability of electroencephalography (EEG) signals in discriminating between different covert speech tasks is investigated. Twelve participants, across two sessions each, were asked to perform multiple iterations of three differing mental tasks for 10 s each: unconstrained rest or the mental repetition of the words “yes” or “no.” A multilayer perceptron (MLP) artificial neural network (ANN) was used to classify all three pairwise combinations of “yes,” “no,” and rest trials and also for ternary classification. An average accuracy of 75.7% ± 9.6 was reached in the classification of covert speech trials versus rest, with all participants exceeding chance level (57.8%). The classification of “yes” versus “no” yielded an average accuracy of 63.2 ± 6.4 with ten participants surpassing chance level (57.8%). Finally, the ternary classification yielded an average accuracy of 54.1% ± 9.7 with all participants exceeding chance level (39.1%). The proposed MLP network provided significantly higher accuracies compared to some of the most common classification techniques in BCI. To our knowledge, this is the first report of using ANN for the classification of EEG covert speech across multiple sessions. Our findings support further study of covert speech as a BCI activation task, potentially leading to the development of more intuitive BCIs for communication.
- 23 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ACM Transactions on Audio, Speech, and Language Processing
- Vol. 25 (12) , 2292-2300
EEG Classification of Covert Speech Using Regularized Neural Networks
Communication using brain-computer interfaces (BCIs) can be non-intuitive, often requiring the performance of a conversation-irrelevant task such as hand motor imagery. In this paper, the reliability of electroencephalography (EEG) signals in discriminating between different covert speech tasks is investigated. Twelve participants, across two sessions each, were asked to perform multiple iterations of three differing mental tasks for 10 s each: unconstrained rest or the mental repetition of the words “yes” or “no.” A multilayer perceptron (MLP) artificial neural network (ANN) was used to classify all three pairwise combinations of “yes,” “no,” and rest trials and also for ternary classification. An average accuracy of 75.7% ± 9.6 was reached in the classification of covert speech trials versus rest, with all participants exceeding chance level (57.8%). The classification of “yes” versus “no” yielded an average accuracy of 63.2 ± 6.4 with ten participants surpassing chance level (57.8%). Finally, the ternary classification yielded an average accuracy of 54.1% ± 9.7 with all participants exceeding chance level (39.1%). The proposed MLP network provided significantly higher accuracies compared to some of the most common classification techniques in BCI. To our knowledge, this is the first report of using ANN for the classification of EEG covert speech across multiple sessions. Our findings support further study of covert speech as a BCI activation task, potentially leading to the development of more intuitive BCIs for communication.