Julie Fontecave-Jallon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Julie Fontecave-Jallon has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Bertrand Rivet
2 shared publications- Bertrand Rivet
GIPSA-lab CNRS UMR 5216, Grenoble Universities, Saint Martin d'Hères 38400, France
2 shared publications - Rémi Souriau
Univ. Grenoble Alpes, CNRS, CHU Grenoble Alpes, Grenoble INP, TIMC-IMAG, La Tronche, France
2 shared publications - Aurélien Bricout
Enovacom, Paris, France
1 shared publication Baptiste Rault
1 shared publicationCharles Eynard
Université Grenoble Alpes
1 shared publication
Latest Publications
- Open Access
- 23 March 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 107
Phonocardiography for robust fetal heart rate estimation in real clinical conditions
- 23 March 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 107
Open AccessPhonocardiography for robust fetal heart rate estimation in real clinical conditions
- Open Access
- 25 January 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 186, 109712
Unsupervised segmentation of heart sounds from abrupt changes detection
- 25 January 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 186, 109712
Open AccessUnsupervised segmentation of heart sounds from abrupt changes detection
- 18 November 2022
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 80
Fetal heart rate monitoring by fusion of estimations from two modalities: A modified Viterbi’s algorithm
- 18 November 2022
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 80
Fetal heart rate monitoring by fusion of estimations from two modalities: A modified Viterbi’s algorithm
- 6 October 2022
- Published by IOP Publishing in Physiological Measurement
- Vol. 43 (10) , 105001
Hidden Markov model in nonnegative matrix factorization for fetal heart rate estimation using physiological priors
Objective. Fetal heart rate (fHR) analysis remains the most common technique for detecting fetal distress when monitoring the fetal well-being during labor. If cardiotocography (CTG) is nowadays the non-invasive clinical reference technique for fHR measurement, it suffers from several drawbacks, hence an increasing interest towards alternative technologies, especially around abdominal ECG (aECG). Approach. An original solution, using a single abdominal lead, was recently proposed to address both the feasibility in clinical routine and the challenging detection of temporal events when facing interfered signals from real life conditions. Based on a specification of the non-negative matrix factorization (NMF) algorithm, it exploits the semi-periodicity of fetal electrocardiogram (fECG) for fHR estimation. However, this method assumes temporal independence and therefore does not consider the continuity property of fHR values. It is thus proposed to add to the NMF framework a hidden Markov model (HMM) to include physiological information about fHR temporal evolution. Under a statistical setting, constraints have been added by accommodating regularization terms through Bayesian priors. Main results. The proposed method is evaluated on 23 real aECG signals from a new clinical database, according to CTG reference, and compared with the original NMF-only algorithm. The new proposed method improves performance, with an agreement with CTG increasing from 71% to 80%. Significance. This highlights the interest of a better modelization of the fHR characteristics for a more robust estimation.
- 6 October 2022
- Published by IOP Publishing in Physiological Measurement
- Vol. 43 (10) , 105001
Hidden Markov model in nonnegative matrix factorization for fetal heart rate estimation using physiological priors
Objective. Fetal heart rate (fHR) analysis remains the most common technique for detecting fetal distress when monitoring the fetal well-being during labor. If cardiotocography (CTG) is nowadays the non-invasive clinical reference technique for fHR measurement, it suffers from several drawbacks, hence an increasing interest towards alternative technologies, especially around abdominal ECG (aECG). Approach. An original solution, using a single abdominal lead, was recently proposed to address both the feasibility in clinical routine and the challenging detection of temporal events when facing interfered signals from real life conditions. Based on a specification of the non-negative matrix factorization (NMF) algorithm, it exploits the semi-periodicity of fetal electrocardiogram (fECG) for fHR estimation. However, this method assumes temporal independence and therefore does not consider the continuity property of fHR values. It is thus proposed to add to the NMF framework a hidden Markov model (HMM) to include physiological information about fHR temporal evolution. Under a statistical setting, constraints have been added by accommodating regularization terms through Bayesian priors. Main results. The proposed method is evaluated on 23 real aECG signals from a new clinical database, according to CTG reference, and compared with the original NMF-only algorithm. The new proposed method improves performance, with an agreement with CTG increasing from 71% to 80%. Significance. This highlights the interest of a better modelization of the fHR characteristics for a more robust estimation.
- 1 August 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 207, 106209
Accelerometry-derived respiratory index estimating apnea-hypopnea index for sleep apnea screening
- 1 August 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 207, 106209
Accelerometry-derived respiratory index estimating apnea-hypopnea index for sleep apnea screening
- 1 September 2018
- Published by IOP Publishing in Physiological Measurement
- Vol. 39 (9) , 095006
Inductive plethysmography in rats: towards a new standard for longitudinal non-invasive cardiac output monitoring in preclinical studies
Objective : Cardiovascular function assessment is most often a mandatory requirement in preclinical studies in all industrialized countries. The invasiveness and impact of the monitoring devices used on animals have to be reduced as far as possible for scientific as well as ethical reasons. In humans, inductive plethysmography (IP) is a commonly used wearable non-invasive technology based on volume recordings. The innovative target of the present work is to transfer the IP technology to cardiac output (CO) measurement in rodents. Approach : A new IP device specifically designed for rodents was developed and compared with the gold standard equipment for CO assessment in rodents. CO was monitored in anesthetized rats equipped with both the IP device and an ultrasonic flow probe during a hemodynamic challenge (volume overload). Main results : Cardiac blood flow measurements with the new IP device are significantly correlated with those obtained with the ultrasonic probe throughout the volume overload procedure ( r = 0.97, p < 0.001). Significance : Our results clearly show that the IP device has adequate technological characteristics to allow accurate CO measurement and can therefore be used for longitudinal non-invasive monitoring in rats.
- 1 September 2018
- Published by IOP Publishing in Physiological Measurement
- Vol. 39 (9) , 095006
Inductive plethysmography in rats: towards a new standard for longitudinal non-invasive cardiac output monitoring in preclinical studies
Objective : Cardiovascular function assessment is most often a mandatory requirement in preclinical studies in all industrialized countries. The invasiveness and impact of the monitoring devices used on animals have to be reduced as far as possible for scientific as well as ethical reasons. In humans, inductive plethysmography (IP) is a commonly used wearable non-invasive technology based on volume recordings. The innovative target of the present work is to transfer the IP technology to cardiac output (CO) measurement in rodents. Approach : A new IP device specifically designed for rodents was developed and compared with the gold standard equipment for CO assessment in rodents. CO was monitored in anesthetized rats equipped with both the IP device and an ultrasonic flow probe during a hemodynamic challenge (volume overload). Main results : Cardiac blood flow measurements with the new IP device are significantly correlated with those obtained with the ultrasonic probe throughout the volume overload procedure ( r = 0.97, p < 0.001). Significance : Our results clearly show that the IP device has adequate technological characteristics to allow accurate CO measurement and can therefore be used for longitudinal non-invasive monitoring in rats.
- 13 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Letters
- Vol. 25 (10) , 1475-1479
Phonocardiogram Signal Denoising Based on Nonnegative Matrix Factorization and Adaptive Contour Representation Computation
This letter introduces a new technique for phonocardiogram (PCG) signal denoising based on nonnegative matrix factorization (NMF) of its spectrogram and adaptive contour representation computation (ACRC) of its short-time Fourier transform (STFT). More precisely, NMFs on PCG and synchronous electrocardiogram spectrograms are first used to filter out high-energy noises from PCG. Then, ACRC is performed on a low-pass filtered version of the STFT of the resulting signal to identify relevant time-frequency components that are subsequently used for signal retrieval. Numerical experiments conducted on a real database of noisy PCG signals, Signal Separation Evaluation Campaign (SiSEC2016), illustrate the superiority of the proposed method over state-of-the-art techniques.
- 13 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Letters
- Vol. 25 (10) , 1475-1479
Phonocardiogram Signal Denoising Based on Nonnegative Matrix Factorization and Adaptive Contour Representation Computation
This letter introduces a new technique for phonocardiogram (PCG) signal denoising based on nonnegative matrix factorization (NMF) of its spectrogram and adaptive contour representation computation (ACRC) of its short-time Fourier transform (STFT). More precisely, NMFs on PCG and synchronous electrocardiogram spectrograms are first used to filter out high-energy noises from PCG. Then, ACRC is performed on a low-pass filtered version of the STFT of the resulting signal to identify relevant time-frequency components that are subsequently used for signal retrieval. Numerical experiments conducted on a real database of noisy PCG signals, Signal Separation Evaluation Campaign (SiSEC2016), illustrate the superiority of the proposed method over state-of-the-art techniques.