Albert Van Eeckhout
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Albert Van Eeckhout has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Angel Lizana
Universitat Autónoma de Barcelona
11 shared publications - Juan Campos
Universitat Autónoma de Barcelona
7 shared publications - Enric Garcia-Caurel
Ecole Polytechnique, LPICM
6 shared publications Juan Campos
Universitat Autónoma de Barcelona
6 shared publicationsCarla Rodríguez
Grup d'Òptica, Physics Department, Universitat Autònoma de Barcelona, Bellaterra, Spain
3 shared publications- Jose Jorge Gil
Department of Applied Physics, University of Cantabria, Av. Los Castros 48, 39005 Santander, Spain
3 shared publications
Latest Publications
- Open Access
- 19 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 10205
IPP and PRT Depolarizing Spaces for the Study of Depolarizing Samples: A Review
Depolarizing spaces can reveal and emphasize depolarization origins in samples, making them suitable tools for target detection and disease diagnosis. The Indices of Polarization Purity (IPP) space, considered a representative depolarizing space, highlights the depolarization characteristics of samples, and has demonstrated its superiority in analyzing and identifying depolarization samples, i.e., biological tissues and scattering environments. Recently, a new polarization representation, the so-called Polarizance–Reflection–Transformation (PRT) space has been proposed, which has been employed to distinguish between non-depolarization systems, as well as analyze anisotropic depolarizers. Importantly, the IPP and PRT spaces provide complementary information of samples, hence presenting more polarimetric characterizations of the samples of interest. In consideration of the high importance of the IPP and PRT spaces in this topic, in this paper, we review the methodology of these two spaces and their applications in depolarizer distinction.
- 19 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 10205
Open AccessIPP and PRT Depolarizing Spaces for the Study of Depolarizing Samples: A Review
Depolarizing spaces can reveal and emphasize depolarization origins in samples, making them suitable tools for target detection and disease diagnosis. The Indices of Polarization Purity (IPP) space, considered a representative depolarizing space, highlights the depolarization characteristics of samples, and has demonstrated its superiority in analyzing and identifying depolarization samples, i.e., biological tissues and scattering environments. Recently, a new polarization representation, the so-called Polarizance–Reflection–Transformation (PRT) space has been proposed, which has been employed to distinguish between non-depolarization systems, as well as analyze anisotropic depolarizers. Importantly, the IPP and PRT spaces provide complementary information of samples, hence presenting more polarimetric characterizations of the samples of interest. In consideration of the high importance of the IPP and PRT spaces in this topic, in this paper, we review the methodology of these two spaces and their applications in depolarizer distinction.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Improving stitching interferometry measurements by a continuous airflow
The stitching interferometry system of ALBA, based on a Fizeau interferometer, is robust to displacement errors and reference manufacturing errors. Nevertheless, it is very sensitive to environmental noise, particularly when measuring long mirrors. One way to reduce the impact of environmental noise is by averaging repeated measurements of the same surface area. However, averaging involves longer measurements, resulting in a compromise between time and measurement uncertainty. In this work, we explore the effect of a fan-generated continuous airflow to reduce the impact of environmental noise. In order to investigate this aspect, we evaluate the contribution of the airflow to Fizeau’s surface reconstruction repeatability, conduct a frequency analysis of the interferometric acquisitions, and perform computational fluid dynamics simulations. Finally, we replicated ALBA’s standard stitching measurement procedure, using a 550 mm section of an x-ray mirror, to assess the advantages of employing a fan with rotating blades for improving measurement repeatability.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Improving stitching interferometry measurements by a continuous airflow
The stitching interferometry system of ALBA, based on a Fizeau interferometer, is robust to displacement errors and reference manufacturing errors. Nevertheless, it is very sensitive to environmental noise, particularly when measuring long mirrors. One way to reduce the impact of environmental noise is by averaging repeated measurements of the same surface area. However, averaging involves longer measurements, resulting in a compromise between time and measurement uncertainty. In this work, we explore the effect of a fan-generated continuous airflow to reduce the impact of environmental noise. In order to investigate this aspect, we evaluate the contribution of the airflow to Fizeau’s surface reconstruction repeatability, conduct a frequency analysis of the interferometric acquisitions, and perform computational fluid dynamics simulations. Finally, we replicated ALBA’s standard stitching measurement procedure, using a 550 mm section of an x-ray mirror, to assess the advantages of employing a fan with rotating blades for improving measurement repeatability.
- 5 November 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (23) , 38811-38823
Unraveling the physical information of depolarizers
The link between depolarization measures and physical nature and structure of material media inducing depolarization is nowadays an open question. This article shows how the joint use of two complementary sets of depolarizing metrics, namely the Indices of polarimetric purity and the Components of purity, are sufficient to completely describe the integral depolarizing properties of a sample. Based on a collection of illustrative and representative polarimetric configurations, a clear and meaningful physical interpretation of such metrics is provided, thus extending the current tools and comprehension for the study and analysis of the depolarizing properties of material media. This study could be of interest to those users dealing with depolarization or depolarizing samples.
- 5 November 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (23) , 38811-38823
Unraveling the physical information of depolarizers
The link between depolarization measures and physical nature and structure of material media inducing depolarization is nowadays an open question. This article shows how the joint use of two complementary sets of depolarizing metrics, namely the Indices of polarimetric purity and the Components of purity, are sufficient to completely describe the integral depolarizing properties of a sample. Based on a collection of illustrative and representative polarimetric configurations, a clear and meaningful physical interpretation of such metrics is provided, thus extending the current tools and comprehension for the study and analysis of the depolarizing properties of material media. This study could be of interest to those users dealing with depolarization or depolarizing samples.
- 15 July 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (8) , 4852-4872
Polarimetric data-based model for tissue recognition
We highlight the potential of a predictive optical model method for tissue recognition, based on the statistical analysis of different polarimetric indicators that retrieve complete polarimetric information (selective absorption, retardance and depolarization) of samples. The study is conducted on the experimental Mueller matrices of four biological tissues (bone, tendon, muscle and myotendinous junction) measured from a collection of 157 ex-vivo chicken samples. Moreover, we perform several non-parametric data distribution analyses to build a logistic regression-based algorithm capable to recognize, in a single and dynamic measurement, whether a sample corresponds (or not) to one of the four different tissue categories.
- 15 July 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (8) , 4852-4872
Polarimetric data-based model for tissue recognition
We highlight the potential of a predictive optical model method for tissue recognition, based on the statistical analysis of different polarimetric indicators that retrieve complete polarimetric information (selective absorption, retardance and depolarization) of samples. The study is conducted on the experimental Mueller matrices of four biological tissues (bone, tendon, muscle and myotendinous junction) measured from a collection of 157 ex-vivo chicken samples. Moreover, we perform several non-parametric data distribution analyses to build a logistic regression-based algorithm capable to recognize, in a single and dynamic measurement, whether a sample corresponds (or not) to one of the four different tissue categories.
- Open Access
- 16 February 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
Polarimetric imaging microscopy for advanced inspection of vegetal tissues
Optical microscopy techniques for plant inspection benefit from the fact that at least one of the multiple properties of light (intensity, phase, wavelength, polarization) may be modified by vegetal tissues. Paradoxically, polarimetric microscopy although being a mature technique in biophotonics, is not so commonly used in botany. Importantly, only specific polarimetric observables, as birefringence or dichroism, have some presence in botany studies, and other relevant metrics, as those based on depolarization, are underused. We present a versatile method, based on a representative selection of polarimetric observables, to obtain and to analyse images of plants which bring significant information about their structure and/or the spatial organization of their constituents (cells, organelles, among other structures). We provide a thorough analysis of polarimetric microscopy images of sections of plant leaves which are compared with those obtained by other commonly used microscopy techniques in plant biology. Our results show the interest of polarimetric microscopy for plant inspection, as it is non-destructive technique, highly competitive in economical and time consumption, and providing advantages compared to standard non-polarizing techniques.
- 16 February 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
Open AccessPolarimetric imaging microscopy for advanced inspection of vegetal tissues
Optical microscopy techniques for plant inspection benefit from the fact that at least one of the multiple properties of light (intensity, phase, wavelength, polarization) may be modified by vegetal tissues. Paradoxically, polarimetric microscopy although being a mature technique in biophotonics, is not so commonly used in botany. Importantly, only specific polarimetric observables, as birefringence or dichroism, have some presence in botany studies, and other relevant metrics, as those based on depolarization, are underused. We present a versatile method, based on a representative selection of polarimetric observables, to obtain and to analyse images of plants which bring significant information about their structure and/or the spatial organization of their constituents (cells, organelles, among other structures). We provide a thorough analysis of polarimetric microscopy images of sections of plant leaves which are compared with those obtained by other commonly used microscopy techniques in plant biology. Our results show the interest of polarimetric microscopy for plant inspection, as it is non-destructive technique, highly competitive in economical and time consumption, and providing advantages compared to standard non-polarizing techniques.
- Open Access
- 14 May 2020
- Published by Wiley in Journal of Biophotonics
- Vol. 13 (8) , e202000083
Depolarization metric spaces for biological tissues classification
Classification of tissues is an important problem in biomedicine. An efficient tissue classification protocol allows, for instance, the guided‐recognition of structures through treated images or discriminating between healthy and unhealthy regions (e.g., early detection of cancer). In this framework, we study the potential of some polarimetric metrics, the so‐called depolarization spaces, for the classification of biological tissues. The analysis is performed using 120 biological ex vivo samples of three different tissues types. Based on these data collection, we provide for the first time a comparison between these depolarization spaces, as well as with most commonly used depolarization metrics, in terms of biological samples discrimination. The results illustrate the way to determine the set of depolarization metrics which optimizes tissue classification efficiencies. In that sense, the results show the interest of the method which is general, and which can be applied to study multiple types of biological samples, including of course human tissues. The latter can be useful for instance, to improve and to boost applications related to optical biopsy.
- 14 May 2020
- Published by Wiley in Journal of Biophotonics
- Vol. 13 (8) , e202000083
Open AccessDepolarization metric spaces for biological tissues classification
Classification of tissues is an important problem in biomedicine. An efficient tissue classification protocol allows, for instance, the guided‐recognition of structures through treated images or discriminating between healthy and unhealthy regions (e.g., early detection of cancer). In this framework, we study the potential of some polarimetric metrics, the so‐called depolarization spaces, for the classification of biological tissues. The analysis is performed using 120 biological ex vivo samples of three different tissues types. Based on these data collection, we provide for the first time a comparison between these depolarization spaces, as well as with most commonly used depolarization metrics, in terms of biological samples discrimination. The results illustrate the way to determine the set of depolarization metrics which optimizes tissue classification efficiencies. In that sense, the results show the interest of the method which is general, and which can be applied to study multiple types of biological samples, including of course human tissues. The latter can be useful for instance, to improve and to boost applications related to optical biopsy.
- Open Access
- 2 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11363, 113631G-54
Depolarizing spaces for biological tissue classification based on a wavelength combination
Tissue classification interest is growing due to their numerous applications in the biomedical framework. This increasing interest leads to the rise of alternative techniques in order to enhance the classification accuracy. Polarimetric methods, and in particular, the study of depolarization properties of samples, appear to be an alternative and complementary technique that helps to discriminate between different organic tissues. In fact, depolarization is directly related with the scattering processes produced in biological tissues, providing different responses when studied in different fibre based structures. In the current state of art, there exists different metrics devised to study depolarizing properties of samples and it is not clear which method is the most suitable for tissue classification. By using some of those polarimetric metrics, a compendium of depolarizing spaces can be constructed, composed of three observables each. Such depolarizing spaces stand out over the other existing polarimetric indicators as they allow synthetizing the depolarization content of samples, to provide further analysis of depolarizers. In this work, we compare the effectivity of different depolarizing spaces in order to determine the best space for tissue classification. This is done by using a collection of chicken thigh tissues. In particular, we have measured the Mueller matrix of 120 samples spread around three chicken thigh tissues: tendon, muscle and myotendinous junction. Different tissues have been imaged at different wavelengths (470 nm, 530 nm and 625 nm) to obtain more information and to amplifying the classification sensitivity with this extra channel (wavelength). Finally, we conclude the work by showing the depolarization space providing the best results in terms of tissue classification.
- 2 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11363, 113631G-54
Open AccessDepolarizing spaces for biological tissue classification based on a wavelength combination
Tissue classification interest is growing due to their numerous applications in the biomedical framework. This increasing interest leads to the rise of alternative techniques in order to enhance the classification accuracy. Polarimetric methods, and in particular, the study of depolarization properties of samples, appear to be an alternative and complementary technique that helps to discriminate between different organic tissues. In fact, depolarization is directly related with the scattering processes produced in biological tissues, providing different responses when studied in different fibre based structures. In the current state of art, there exists different metrics devised to study depolarizing properties of samples and it is not clear which method is the most suitable for tissue classification. By using some of those polarimetric metrics, a compendium of depolarizing spaces can be constructed, composed of three observables each. Such depolarizing spaces stand out over the other existing polarimetric indicators as they allow synthetizing the depolarization content of samples, to provide further analysis of depolarizers. In this work, we compare the effectivity of different depolarizing spaces in order to determine the best space for tissue classification. This is done by using a collection of chicken thigh tissues. In particular, we have measured the Mueller matrix of 120 samples spread around three chicken thigh tissues: tendon, muscle and myotendinous junction. Different tissues have been imaged at different wavelengths (470 nm, 530 nm and 625 nm) to obtain more information and to amplifying the classification sensitivity with this extra channel (wavelength). Finally, we conclude the work by showing the depolarization space providing the best results in terms of tissue classification.
- 31 March 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (8) , 10981-11000
Influence of temporal averaging in the performance of a rotating retarder imaging Stokes polarimeter
We study the optimum operating conditions for a rotating retarder fixed polarizer (RRFP) when the measurements are not quasi-instantaneous but time-averaged. We obtain the optimum retardance and retarder orientations as a function of the integrated angle interval. We also study how the increase in the number of time-averaged measurements leads to a better equally weighted variance (EWV) value, and thus, to a better performance of the polarimeter in terms of noise amplification for the case of additive noise. Two different analyzers configurations are studied in this work: uniformly spaced retarder angles and when measurements are taken at optimum angles (non-uniformly spaced angles). We also consider the case of polychromatic illumination. We discuss the best measurement conditions in terms of the signal-to-noise ratio depending on whether there is a fixed or a limited amount of photons per measurement.
- 31 March 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (8) , 10981-11000
Influence of temporal averaging in the performance of a rotating retarder imaging Stokes polarimeter
We study the optimum operating conditions for a rotating retarder fixed polarizer (RRFP) when the measurements are not quasi-instantaneous but time-averaged. We obtain the optimum retardance and retarder orientations as a function of the integrated angle interval. We also study how the increase in the number of time-averaged measurements leads to a better equally weighted variance (EWV) value, and thus, to a better performance of the polarimeter in terms of noise amplification for the case of additive noise. Two different analyzers configurations are studied in this work: uniformly spaced retarder angles and when measurements are taken at optimum angles (non-uniformly spaced angles). We also consider the case of polychromatic illumination. We discuss the best measurement conditions in terms of the signal-to-noise ratio depending on whether there is a fixed or a limited amount of photons per measurement.
- 15 April 2019
- Published by Optica Publishing Group in OSA Continuum
- Vol. 2 (5) , 1565-1575
Misalignment error analysis in polychromatic division of focal plane Stokes polarimeters
Snapshot imaging polarimeters are used in many different areas. Recently, division of focal plane (DoFP) polarimeters have proved useful as snapshot polarimeters for dynamic applications. For an optimal performance of polarimeters, different works dealing with the error analysis of such devices are proposed in literature. In terms of noise amplification from intensity measurements to the final polarization calculations, well-established quality metrics, as in the condition number or the equally weighted variance criteria, are used. Other studies analyze systematic errors due to deviations in the construction parameters. However, something not considered so far is the effect produced by misalignment between the various pixelated masks over the pixelated structure of the camera sensor, always occurring in experimental implementations of DoFPs. In this work, we study the effect of such misalignments in DoFP polarimeters and demonstrate how they lead to polarimetric systems composed of partially depolarized analyzers. We calculate the combined degree of polarization related to different amounts of misalignment and analyze the corresponding system performance. From this study, we show how an imaging polarimeter based on partially polarized analyzers can still lead to a robust and accurate polarimetric performance, and we also provide the misalignment limits in which an acceptable performance is obtained. We evaluate both the monochromatic and the polychromatic cases with special focus on the latter.
- 15 April 2019
- Published by Optica Publishing Group in OSA Continuum
- Vol. 2 (5) , 1565-1575
Misalignment error analysis in polychromatic division of focal plane Stokes polarimeters
Snapshot imaging polarimeters are used in many different areas. Recently, division of focal plane (DoFP) polarimeters have proved useful as snapshot polarimeters for dynamic applications. For an optimal performance of polarimeters, different works dealing with the error analysis of such devices are proposed in literature. In terms of noise amplification from intensity measurements to the final polarization calculations, well-established quality metrics, as in the condition number or the equally weighted variance criteria, are used. Other studies analyze systematic errors due to deviations in the construction parameters. However, something not considered so far is the effect produced by misalignment between the various pixelated masks over the pixelated structure of the camera sensor, always occurring in experimental implementations of DoFPs. In this work, we study the effect of such misalignments in DoFP polarimeters and demonstrate how they lead to polarimetric systems composed of partially depolarized analyzers. We calculate the combined degree of polarization related to different amounts of misalignment and analyze the corresponding system performance. From this study, we show how an imaging polarimeter based on partially polarized analyzers can still lead to a robust and accurate polarimetric performance, and we also provide the misalignment limits in which an acceptable performance is obtained. We evaluate both the monochromatic and the polychromatic cases with special focus on the latter.
- Open Access
- 14 March 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (3) , e0213909
Depolarizing metrics for plant samples imaging
Optical methods, as fluorescence microscopy or hyperspectral imaging, are commonly used for plants visualization and characterization. Another powerful collection of optical techniques is the so-called polarimetry, widely used to enhance image contrast in multiple applications. In the botanical applications framework, in spite of some works have already highlighted the depolarizing print that plant structures left on input polarized beams, the potential of polarimetric methods has not been properly exploited. In fact, among the few works dealing with polarization and plants, most of them study light scattered by plants using the Degree of Polarization (DoP) indicator. Other more powerful depolarization metrics are nowadays neglected. In this context, we highlight the potential of different depolarization metrics obtained using the Mueller matrix (MM) measurement: the Depolarization Index and the Indices of Polarimetric Purity. We perform a qualitative and quantitative comparison between DoP- and MM-based images by studying a particular plant, the Hedera maroccana. We show how Mueller-based metrics are generally more suitable in terms of contrast than DoP-based measurements. The potential of polarimetric measurements in the study of plants is highlighted in this work, suggesting they can be applied to the characterization of plants, plant taxonomy, water stress in plants, and other botanical studies.
- 14 March 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (3) , e0213909
Open AccessDepolarizing metrics for plant samples imaging
Optical methods, as fluorescence microscopy or hyperspectral imaging, are commonly used for plants visualization and characterization. Another powerful collection of optical techniques is the so-called polarimetry, widely used to enhance image contrast in multiple applications. In the botanical applications framework, in spite of some works have already highlighted the depolarizing print that plant structures left on input polarized beams, the potential of polarimetric methods has not been properly exploited. In fact, among the few works dealing with polarization and plants, most of them study light scattered by plants using the Degree of Polarization (DoP) indicator. Other more powerful depolarization metrics are nowadays neglected. In this context, we highlight the potential of different depolarization metrics obtained using the Mueller matrix (MM) measurement: the Depolarization Index and the Indices of Polarimetric Purity. We perform a qualitative and quantitative comparison between DoP- and MM-based images by studying a particular plant, the Hedera maroccana. We show how Mueller-based metrics are generally more suitable in terms of contrast than DoP-based measurements. The potential of polarimetric measurements in the study of plants is highlighted in this work, suggesting they can be applied to the characterization of plants, plant taxonomy, water stress in plants, and other botanical studies.