Engin Söylemez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Engin Söylemez has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ayhan Onat
Marmara Üniversitesi, Teknoloji Fakültesi
2 shared publications - Emre Alpman
Marmara University
2 shared publications - Armin Hafner
Department of Energy and Process Engineering, Norwegian University of Science and Technology (NTNU), 7491 Trondheim, Norway
1 shared publication - Christian Schlemminger
Sintef Energy Research, Department of Thermal Energy, 7465 Trondheim, Norway
1 shared publication - Ekaterini E. Kriezi
RAC R&D Danfoss A/S -Nordborgvej 81, 6430 Nordborg, Denmark
1 shared publication Selim Hartomacıoğlu
1 shared publication
Latest Publications
- Open Access
Energy and Conventional Exergy Analysis of an Integrated Transcritical CO2 (R-744) Refrigeration System
This study analyses the performance of an integrated transcritical CO2 (R-744) refrigeration system operating in winter conditions within a supermarket in Trento, north Italy. This system fulfils multiple functions, providing the heating (for domestic hot water and space heating), cooling, and freezing capabilities for the supermarket. Energy analysis reveals that the average value of the total coefficient of performance, total COP, over the entire study period is calculated at 2.47. Notably, the medium-temperature (MT) compressor rack exhibits the highest power consumption, especially in sub −5 °C conditions. The auxiliary (AUX) compressor rack and the gas cooler (GC) fan contribute significantly to the electrical power usage. The air conditioning (AC) heating load is consistently high, averaging 41.6 kW, while the domestic hot water (DHW) heating load remains stable at approximately 5 kW. The refrigeration demands include an average MT cooling load of 25.86 kW and a low-temperature (LT) freezing load of 10–15 kW, with an average of 13.76 kW. The current study also delves into exergy analysis, disclosing an overall system exergy efficiency of 22.4%. The AUX compressor rack is identified as the primary exergy destructor, followed by the GC, AC coils, MT compressor rack, and the ejector. The LT compressor rack has the highest exergy efficiency, followed by the MT and LT expansion valves.
Open AccessEnergy and Conventional Exergy Analysis of an Integrated Transcritical CO2 (R-744) Refrigeration System
This study analyses the performance of an integrated transcritical CO2 (R-744) refrigeration system operating in winter conditions within a supermarket in Trento, north Italy. This system fulfils multiple functions, providing the heating (for domestic hot water and space heating), cooling, and freezing capabilities for the supermarket. Energy analysis reveals that the average value of the total coefficient of performance, total COP, over the entire study period is calculated at 2.47. Notably, the medium-temperature (MT) compressor rack exhibits the highest power consumption, especially in sub −5 °C conditions. The auxiliary (AUX) compressor rack and the gas cooler (GC) fan contribute significantly to the electrical power usage. The air conditioning (AC) heating load is consistently high, averaging 41.6 kW, while the domestic hot water (DHW) heating load remains stable at approximately 5 kW. The refrigeration demands include an average MT cooling load of 25.86 kW and a low-temperature (LT) freezing load of 10–15 kW, with an average of 13.76 kW. The current study also delves into exergy analysis, disclosing an overall system exergy efficiency of 22.4%. The AUX compressor rack is identified as the primary exergy destructor, followed by the GC, AC coils, MT compressor rack, and the ejector. The LT compressor rack has the highest exergy efficiency, followed by the MT and LT expansion valves.
- Open Access
The Performance Analysis of an Integrated CO2 Refrigeration System with Multi-Ejectors Installed in a Supermarket
The field data from an integrated CO2 refrigeration system installed in a supermarket located north of the capital of Lisbon was analyzed. The goal was to demonstrate the effect and performance of multi-ejectors on a refrigeration system operating in a warm climate. The measurement results for the system with and without activating ejectors were compared. It was observed that the system with a multi-ejector operation had considerable performance superiority. The ejectors improved the cooling capacity of the medium temperature stage of the system by 17.4%. The system with active ejectors had 7.5% less total power consumption compared to the ejector off mode of the same system.
Open AccessThe Performance Analysis of an Integrated CO2 Refrigeration System with Multi-Ejectors Installed in a Supermarket
The field data from an integrated CO2 refrigeration system installed in a supermarket located north of the capital of Lisbon was analyzed. The goal was to demonstrate the effect and performance of multi-ejectors on a refrigeration system operating in a warm climate. The measurement results for the system with and without activating ejectors were compared. It was observed that the system with a multi-ejector operation had considerable performance superiority. The ejectors improved the cooling capacity of the medium temperature stage of the system by 17.4%. The system with active ejectors had 7.5% less total power consumption compared to the ejector off mode of the same system.
- 1 March 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 99, 300-315
Numerical (CFD) and experimental analysis of hybrid household refrigerator including thermoelectric and vapour compression cooling systems
- 1 March 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 99, 300-315
Numerical (CFD) and experimental analysis of hybrid household refrigerator including thermoelectric and vapour compression cooling systems
- 1 November 2018
- Published by Elsevier in International Journal of Refrigeration
- Vol. 95, 93-107
Experimental analysis of hybrid household refrigerators including thermoelectric and vapour compression cooling systems
- 1 November 2018
- Published by Elsevier in International Journal of Refrigeration
- Vol. 95, 93-107
Experimental analysis of hybrid household refrigerators including thermoelectric and vapour compression cooling systems