YHYanjun Hua

Yanjun Hua

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yanjun Hua has a total of 51 co-authors. Here are the top co-authors by number of shared publications:

  • Chao Pan

    Aier Eye Hospital, Wuhan, China

    8 shared publications
  • Jinhai Huang

    Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China

    8 shared publications
  • Qinmei Wang

    School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, China

    8 shared publications
  • Giacomo Savini

    IRCCS Bietti Foundation, Rome, Italy

    5 shared publications
  • Yifan Feng

    From the School of Optometry and Ophthalmology and Eye Hospital (Wang, Ding, Chen, Feng, Pan, Hua, Huang), Wenzhou Medical University, and the Key Laboratory of Vision Science (Wang, Ding, Chen, Huang), Ministry of Health P.R. China, Wenzhou, Zhejiang, China; G.B. Studio Oculistico d'Azeglio (Savini), Bologna, Italy

    5 shared publications
  • Qiang Wu

    Department of Ophthalmology, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai 200233, China

    3 shared publications

Latest Publications

  • Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes

    by Yanjun Hua, Chao Pan, Qinmei Wang

    To develop a new regression formula based on the Gaussian thick lens formula and to verify the accuracy of the regression formula.


  • Open Access

    The thickness and volume of the choroid, outer retinal layers and retinal pigment epithelium layer changes in patients with diabetic retinopathy

    by Xiang-Ning Wang, Shu-Ting Li, Wei Li, Yan-Jun Hua, Qiang Wu

    AIM: To evaluate the thickness and volume changes of the choroidal, outer retinal layers (ORL) and retinal pigment epithelium (RPE) in patients with diabetic retinopathy (DR) using optical coherence tomography (OCT) and correlate them with visual acuity. METHODS: We carried out a retrospective observational case series. Consecutive DR patients were recruited for color fundus photography and OCT assessment. The RPE, ORL and choroidal thickness were measured. The correlation with the best-corrected visual acuity (BCVA) was also investigated. RESULTS: The study included 128 eyes, comprising 45 eyes of 25 diabetic macular edema (DME) patients, 34 eyes of 20 DR without DME (non-DME) patients, and 49 eyes of 25 age-matched normal individuals. The choroidal thickness in DR patients were decreased statistically significantly compared with the control group (P<0.05). The mean macular ORL thickness in DME (73.02 +/- 15.34 mu m) and non-DME groups (76.35 +/- 7.32 mu m) were decreased statistically significantly compared with the control group (80.20 +/- 5.85 mu m; P=0.006, P=0.013, respectively). In both the non-DME and DME groups, the RPE thickness were decreased compared with the control group (P<0.05), except in the macular and central ring. The BCVA were significant interactions with the total inner retinal volume and macular RPE thickness in the DME group (r=0.115, P<0.001, r=-0.013, P=0.017, respectively). CONCLUSION: The choroid, ORL and RPE thickness are significantly decreased in DR patients compared with controls in different segments.


  • Open Access

    Precision (repeatability and reproducibility) of ocular parameters obtained by the Tomey OA-2000 biometer compared to the IOLMaster in healthy eyes

    by Yanjun Hua, Wei Qiu, Qiuyi Xiao, Qiang Wu

    To assess the precision (repeatability and reproducibility) of ocular parameters measured by the Tomey OA-2000 biometer, and to compare them with those measured by the IOLMaster. In this prospective study, the right eyes of 108 healthy subjects were included. Three consecutive scans were obtained by 2 observers using the Tomey OA-2000, and in the same session one observer used the IOLMaster (version 5.4.4.0006) for the measurements. About 1 week later, 3 scans were obtained by one observer using the Tomey OA-2000. The axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), keratometer readings, pupil diameter (PD) and corneal diameter (CD) values measured by the Tomey OA-2000 and IOLMaster were analyzed. The coefficient of variation (CoV), intraclass correlation coefficient (ICC), within subject standard deviation (Sw) and 2.77Sw were calculated to assess the repeatability and reproducibility. The paired t test and Bland-Altman plots were used to analyze the differences and agreements of parameters measured by the two devices, respectively. Intraobserver repeatability, and interobserver and intersession reproducibility of the AL, CCT, ACD, LT, Kf, Ks, Km, PD and CD values measured by the Tomey OA-2000 biometer showed a CoV of less than 1% except that for PD, and an ICC of more than 0.97 except that for PD and CD. The AL, Kf, Ks, Km and CD values measured by the Tomey OA-2000 were 0.058 ± 0.094 mm, 0.088± 0.150 diopters (D), 0.163 ± 0.170 D, 0.127 ± 0.117 D and 0.171 ± 0.217 mm lower than those measured by the IOLMaster, respectively (all Ps < 0.05). However, the ACD values from the two devices were comparable (P = 0.169). The 95% linite of agreement (LoA) of the AL, ACD, CD and all keratometer readings were no more than 0.24 mm, 0.14 mm 0.60 mm and 0.5 D, respectively. Except for the PD and CD, the ocular parameters measured by the Tomey OA-2000 were highly repeatable and reproducible. Except for the CD value, there was good agreement of ocular parameters measured by the Tomey OA-2000 and the IOLMaster in healthy eyes.


  • Open Access

    Precision and agreement of higher order aberrations measured with ray tracing and Hartmann-Shack aberrometers

    by Zequan Xu, Yanjun Hua, Wei Qiu, Guoqiang Li, Qiang Wu

    To assess the precision and agreement of measurements of higher order aberrations (HOAs) obtained with a ray tracing aberrometer (iTrace) and a Hartmann-Shack aberrometer (Topcon KR-1 W). Prospective evaluation of the diagnostic test. Data from the right eyes of 92 normal subjects obtained using the two devices were included in this study. Two observers performed 3 consecutive scans to determine the intraobserver repeatability and interobserver reproducibility. About one week later, one observer performed an additional 3 consecutive scans to obtain the intersession reproducibility. The within-subject standard deviation (Sw), test-retest repeatability (TRT) and intraclass correlation coefficient (ICC) were used to assess the precision, while Bland-Altman plots were performed to assess the agreement. For intraobserver repeatability of the ocular, corneal and internal HOAs, Topcon KR-1 W showed a 2.77Sw of 0.079 μm or less and ICCs of 0.761 or more; and iTrace showed a 2.77Sw of 0.105 μm or less and ICCs of 0.805 or more. The ICCs of the internal HOAs of interobserver reproducibility were less than 0.75 except for spherical aberration (SA) (0.862), and interobserver reproducibility of the counterpart showed similar but lower results. For the ocular, corneal and internal HOA measurements, statistically significant differences existed between the Topcon KR-1 W and iTrace (all P < 0.05). No significant differences were observed in the ocular SA and internal coma. The ray tracing and Hartmann-Shack method aberrometers provided excellent repeatability but less reliable reproducibility in the measurement of HOAs (except for SA). The two aberrometers should not be interchangeable in clinical application because of the significant differences in HOA measurements between them.


  • Choroidal Variations in Diabetic Macular Edema: Fluorescein Angiography and Optical Coherence Tomography

    by Xiangning Wang, Shuting Li, Wei Li, Yanjun Hua, Qiang Wu

    To (i) evaluate variations in choroidal thickness (CT) and choroidal volume (CV) in diabetic macular edema (DME), as demonstrated by fluorescein angiography (FA) and enhanced depth-imaging (EDI) optical coherence tomography (OCT) (EDI-OCT) and (ii) correlate these variations with visual acuity. This study was a retrospective observational case series of patients with diabetic retinopathy (DR) and DME. The study groups comprised 77 DR patients (n = 87), all of whom underwent color fundus photography, FA, and OCT on the same day. The control group comprised 25 age-matched healthy individuals (n = 50 eyes). CT was measured by manual segmentation (EDI-OCT built-in automated retinal segmentation software). Variations in CT in DME patterns were analyzed. We studied a total of 87 eyes from patients with DR, including 50 eyes from 25 patients with DME (DME group) and 37 eyes from 22 patients without DME (non-DME group). For DME-group patients, mean subfoveal choroidal thickness (SFCT) and total CV (TCV) were 258.8 ± 81.7 µm and 6.6 ± 1.8 mm3, respectively. For non-DME group patients, mean SFCT and TCV values were 247.6 ± 73.3 µm and 6.6 ± 1.6 mm3, respectively. SFCT and TCV values for both groups were significantly lower than for healthy controls (294.3 ± 87.6 µm and 7.7 ± 1.8 mm,3 respectively) (p = 0.040 and 0.019, respectively). CTs varied according to morphological FA and OCT patterns of DME, but did not differ significantly (p > 0.05). CT and CV in DR patients were decreased compared with healthy controls. CTs did not differ significantly between DME patterns demonstrated by OCT and FA.


  • Open Access

    Evaluation of Equivalent Keratometry Readings Obtained by Pentacam HR (High Resolution)

    by Yanjun Hua, Xiaolan Zhang, Tor Paaske Utheim, Jinhai Huang, Chao Pan, Weina Tan, Qinmei Wang

    To assess the repeatability of Equivalent Keratometry Readings (EKRs) obtained by the Pentacam HR (high resolution) in untreated and post-LASIK eyes, and to compare them with the keratometry (K) values obtained by other algorithms. In this prospective study, 100 untreated eyes and 71 post-LASIK eyes were included. In the untreated group, each eye received 3 consecutive scans using the Pentacam HR, and EKR values in all central corneal zone, the true net power (Knet) and the simulated K (SimK) were obtained for each scan. In the post-LASIK group, each eye received subjective refraction and 3 consecutive scans with the Pentacam HR preoperatively. During the 3-month post-surgery exam, the same examinations and the use of an IOLMaster were conducted for each eye. The EKRs in all zone, the Knet, the mean K (Km) by IOLMaster and the K values by clinical history method (KCHM) were obtained. The repeatability of the EKRs was assessed by the within-subject standard deviation (Sw), 2.77Sw, coefficient of variation (CVw) and intraclass correlation coefficient (ICC). The bonferroni corrected multiple comparisons were performed to analyze the differences among the EKRs and K values calculated by other algorithms within the 2 groups. The 95% limits of agreement (LoA) were calculated. The EKR values in all central corneal zone were repeatable in both the untreated group (Sw≦0.19 D, 2.77Sw≦0.52 D, CVw≦1%, ICC≧0.978) and the post-LASIK group (Sw≦0.22 D, 2.77Sw≦0.62 D, CVw≦1%, ICC≧0.980). In the untreated group, the EKR in 4mm zone was close to SimK (P = 1.000), and the 95% LoA was (-0.13 to 0.15 D). The difference between Knet and SimK was -1.30±0.13 D (95% LoA -1.55 to -1.55 D, PCHM (all PCHM, the EKR in 7mm zone and KCHM, Knet and KCHM, Km and KCHM, SimK and Knet were 0.64±0.50 D (95% LoA, -0.33 to 1.62 D), 1.77±0.88 D (95% LoA, 0.04 to 3.51 D), -0.98±0.48 D (95% LoA, -1.92 to -0.04 D), 0.64±0.53 D (95% LoA, -0.40 to 1.68 D), and 1.73±0.20 D (95% LoA, 1.33 to 2.13 D), respectively. The EKRs obtained by the Pentacam HR were repeatable in both untreated eyes and post-LASIK eyes. Compared to the total corneal power obtained by the clinical history method, the EKR values generally overestimated the total corneal power in post-LASIK eyes. So, further calibrations for the EKR values should be conducted, before they were used for the total corneal power assessment in post-LASIK eyes.


  • Corneal Power Measurement With the Dual Scheimpflug-Placido Topographer After Myopic Excimer Laser Surgery

    by Chao Pan, Yanjun Hua, Jinhai Huang, Weina Tan, Weicong Lu, Qinmei Wang

    PURPOSE: To evaluate the ability of the Sirius Scheimpflug-Placido Topographer (Costruzione Strumenti Oftalmici, Florence, Italy) in predicting corneal power in eyes with previous myopic corneal refractive surgery. METHODS: The following corneal refractive power measurements were obtained with Sirius in 38 eyes with prior myopic excimer laser surgery: simulated keratometry (SimK), true net power based on the Gaussian optical formula (TNP), and the mean pupil power (MPP) calculated by ray tracing within the diameter of the entrance pupil range from 2.5 to 6 mm. These values, along with the corresponding keratometric value, which was based on the equation that converted the MPP within 4.5-mm entrance pupil diameter to a keratometric reading in 75 myopic eyes, were compared using the clinical history method. RESULTS: SimK significantly overestimated corneal power by 0.67 ± 0.52 diopters (D), whereas TNP significantly underestimated corneal power by −1.05 ± 0.48 D. The only measurements that showed no statistically significant difference by the clinical history method were the 5 mm MPP, 5.5 mm MPP, and K MPP4.5POST , and the 95% limits of agreement (LOA) were −1.10 to 0.62, −0.91 to 0.89, and −0.67 to 1.05 D, respectively. CONCLUSIONS: The Sirius Scheimpflug-Placido Topographer is an alternative method of measuring corneal power in eyes with previous corneal refractive surgery for myopia when preoperative data are not available. The best options seem to be the 5 mm MPP, 5.5 mm MPP, and the keratometric reading calculated from the regression formula. [ J Refract Surg. 2016;32(3):182–186.]


  • Open Access

    Precision (Repeatability and Reproducibility) and Agreement of Corneal Power Measurements Obtained by Topcon KR-1W and iTrace

    by Yanjun Hua, Zequan Xu, Wei Qiu, Qiang Wu

    To evaluate the repeatability and reproducibility of corneal power measurements obtained by Topcon KR-1W and iTrace, and assess the agreement with measurements obtained by Allegro Topolyzer and IOLMaster. The right eyes of 100 normal subjects were prospectively scanned 3 times using all the 4 devices. Another observer performed additional 3 consecutive scans using the Topcon KR-1W and iTrace in the same session. About one week later, the first observer repeated the measurements using the Topcon KR-1W and iTrace. The steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), J0 and J45 were analyzed. Repeatability and reproducibility of measurements were evaluated by the within-subject standard deviation (Sw), coefficient of variation (CoV), test-retest repeatability (2.77Sw), and intraclass correlation coefficient (ICC). Agreements between devices were assessed using Bland-Altman analysis and 95% limits of agreement (LoA). Intraobserver repeatability and interobserver and intersession reproducibility of the Ks, Kf and Km showed a CoV of no more than 0.5%, a 2.77Sw of 0.70 D or less, and an ICC of no less than 0.99. However, J0 and J45 showed poor intraobserver repeatability and interobserver and intersession reproducibility (all ICCs not greater than 0.446). Statistically significant differences existed between Topcon KR-1W and IOLMaster, Topcon KR-1W and iTrace, Topcon KR-1W and Topolyzer, iTrace and Topolyzer, iTrace and IOLMaster for Ks, Kf and Km measurements (all P < 0.05). The mean differences between Topcon KR-1W, iTrace, and the other 2 devices were small. The 95% LoA were approximately 1.0 D to 1.5 D for all measurements. The Ks, Kf and Km obtained by Topcon KR-1W and iTrace showed excellent intraobserver repeatability and interobserver and intersession reproducibility in normal eyes. The agreement between Topcon KR-1W and Topolyzer, Topcon KR-1W and IOLMaster, iTrace and Topolyzer, iTrace and IOLMaster, Topcon KR-1W and iTrace were not so good, they should not be interchangeable in clinical application. Given that the intraobserver repeatability and interobserver and intersession reproducibility of corneal astigmatism measurements obtained by Topcon KR-1W and iTrace were poor, it should be cautious that Topcon KR-1W and iTrace were applied for the preparation of toric lens implantation.


  • Corneal Power Measurement Obtained by Fourier-Domain Optical Coherence Tomography

    by Qinmei Wang, Yanjun Hua, Giacomo Savini, Hao Chen, Fangjun Bao, Shishi Lin, Weicong Lu, Jinhai Huang

    To assess the repeatability and reproducibility of corneal power values obtained by a Fourier-domain optical coherence tomography (FD-OCT) system (RTVue) and to compare them with the values obtained by a Scheimpflug camera system (Pentacam HR) and by automated keratometry (IOL Master). Thirty-two eyes from 32 healthy subjects were included in this prospective study. Two experienced observers measured each eye 3 consecutive times with the Pentacam, IOLMaster, and RTVue centered on either the pupil or corneal vertex. The conventional keratometry equivalent (CKE) and anterior (Ka), posterior (Kp), and net (Kn) corneal power values were determined. The corneal power values obtained by the RTVue showed high repeatability (all intraclass correlation coefficient >0.96) and reproducibility (coefficient of variation <1.0%). Pupil-centered FD-OCT performed slightly better than corneal vertex-centered FD-OCT. Mean corneal values had higher reproducibly than any of the individual values. CKE, Ka, Kp, and Kn obtained by FD-OCT were 0.62 to 0.68 diopters (D), 0.70 to 0.76 D, 0.11 to 0.13 D, and 0.93 to 0.94 D higher than those obtained by the Pentacam HR, respectively. CKE and Ka obtained with the RTVue were also 0.60 to 0.74 D higher than those obtained with the IOLMaster, respectively. The corneal power measurements obtained by the RTVue FD-OCT system showed high repeatability and reproducibility. Measurements obtained by FD-OCT with pupil centration were more reproducible than those obtained by FD-OCT with corneal vertex centration. We recommend that pupil-centered FD-OCT be used in clinical applications. Neither RTVue versus Pentacam HR nor RTVue versus IOLMaster can be used interchangeably.


  • Open Access

    Keratometric Index Obtained by Fourier-Domain Optical Coherence Tomography

    by Yanjun Hua, Aleksander Stojanovic, Tor Paaske Utheim, Xiangjun Chen, Sten Ræder, Jinhai Huang, Qinmei Wang

    To determine the keratometric indices calculated based on parameters obtained by Fourier-domain optical coherence tomography (FD-OCT). The ratio of anterior corneal curvature to posterior corneal curvature (Ratio) and keratometric index (N) were calculated within central 3 mm zone with the RTVue FD-OCT (RTVue, Optovue, Inc.) in 186 untreated eyes, 60 post-LASIK/PRK eyes, and 39 keratoconus eyes. The total corneal powers were calculated using different keratometric indices: Kcal based on the mean calculated keratometric index, K1.3315 calculated by the keratometric index of 1.3315, and K1.3375 calculated by the keratometric index of 1.3375. In addition, the total corneal powers based on Gaussian optics formula (Kactual) were calculated. The means for Ratio in untreated controls, post-LASIK/PRK group and keratoconus group were 1.176 ± 0.022 (95% confidence interval (CI), 1.172–1.179), 1.314 ± 0.042 (95%CI, 1.303–1.325) and 1.229 ± 0.118 (95%CI, 1.191–1.267), respectively. And the mean calculated keratometric index in untreated controls, post-LASIK/PRK group and keratoconus group were 1.3299 ± 0.00085 (95%CI, 1.3272–1.3308), 1.3242 ± 0.00171 (95%CI, 1.3238–1.3246) and 1.3277 ± 0.0046 (95%CI, 1.3263–1.3292), respectively. All the parameters were normally distributed. The differences between Kcal and Kactual, K1.3315 and Kactual, and K1.3375 and Kactual were 0.00 ± 0.11 D, 0.21 ± 0.11 D and 0.99 ± 0.12 D, respectively, in untreated controls; -0.01 ± 0.20 D, 0.85 ± 0.18 D and 1.56 ± 0.16 D, respectively, in post-LASIK/PRK group; and 0.03 ± 0.67 D, 0.56 ± 0.70 D and 1.40 ± 0.76 D, respectively, in keratoconus group. The calculated keratometric index is negatively related to the ratio of anterior corneal curvature to posterior corneal curvature in untreated, post-LASIK/PRK, and keratoconus eyes, respectively. Using the calculated keratometric index may improve the prediction accuracies of total corneal powers in untreated controls, but not in post-LASIK/PRK and keratoconus eyes.