Kaitlyn R. Ammann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kaitlyn R. Ammann has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Marvin J. Slepian
Department of Computer Sciences, University of Arizona, Tucson, USA
11 shared publications - Yana Roka-Moiia
Palladin Institute of Biochemistry, NAS of Ukraine
3 shared publications Alberto Redaelli
Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
2 shared publicationsDaniel Palomares
Departments of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ 85721, United States; Arizona Center for Accelerated Biomedical Innovation, University of Arizona, Tucson, AZ 85721, United States
2 shared publicationsDanny Bluestein
Department of Biomedical Engineering, Stony Brook University, NY 11794, United States
2 shared publicationsJawaad Sheriff
Department of Biomedical Engineering, Stony Brook University, NY 11794, United States
2 shared publications
Latest Publications
- Open Access
- 2 July 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (3) , 1713-1722
Enhanced Hemocompatibility via Bivalirudin and Bicarbonate as Alternative to Heparin in a Catheter‐Based Axial‐Flow System
Background: Cardiovascular therapeutic devices typically require systemic heparin due to underlying thrombotic risk. The Impella axial flow system further relies on internal perfusion with either a heparin‐containing or sodium bicarbonate purge solution during operation. The combination of systemic and device‐mediated heparin often contributes to varying levels of overall anticoagulation, raising the possibility of increased bleeding risk and complications due to heparin sensitivity. To reduce adverse events, efforts have been ongoing to eliminate heparin, both systemically and via the device. Here, we investigate bivalirudin as an alternative to systemic heparin and sodium bicarbonate as an alternative to local device heparin in the purge solution. Methods: We examined hemocompatibility in a mock loop environment with circulating whole porcine blood to determine feasibility of heparin‐free Impella system. Anticoagulated (heparin or bivalirudin) blood was loaded into a circulatory loop with a contained Impella 5.5 and run for 4 h with either heparin or sodium bicarbonate‐containing purge solution. Blood samples were collected serially and analyzed for metrics of hemocompatibility: hemolysis, platelet activation, and vWF degradation. Results: Bivalirudin and sodium bicarbonate adjunctive environment led to similar or improved hemocompatibility as compared to heparin‐containing environment—notably, decreased hemolysis (40 ± 20.8 mg/dL average decrease) and preserved platelet activity measured by P‐selectin exposure (8.0 ± 5.6% average increase). Conclusions: Our data supports the potential to create an overall heparin‐free approach simplifying anticoagulation management, offering potential for overall reduced bleeding risk and heparin‐related complications.
- 2 July 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (3) , 1713-1722
Open AccessEnhanced Hemocompatibility via Bivalirudin and Bicarbonate as Alternative to Heparin in a Catheter‐Based Axial‐Flow System
Background: Cardiovascular therapeutic devices typically require systemic heparin due to underlying thrombotic risk. The Impella axial flow system further relies on internal perfusion with either a heparin‐containing or sodium bicarbonate purge solution during operation. The combination of systemic and device‐mediated heparin often contributes to varying levels of overall anticoagulation, raising the possibility of increased bleeding risk and complications due to heparin sensitivity. To reduce adverse events, efforts have been ongoing to eliminate heparin, both systemically and via the device. Here, we investigate bivalirudin as an alternative to systemic heparin and sodium bicarbonate as an alternative to local device heparin in the purge solution. Methods: We examined hemocompatibility in a mock loop environment with circulating whole porcine blood to determine feasibility of heparin‐free Impella system. Anticoagulated (heparin or bivalirudin) blood was loaded into a circulatory loop with a contained Impella 5.5 and run for 4 h with either heparin or sodium bicarbonate‐containing purge solution. Blood samples were collected serially and analyzed for metrics of hemocompatibility: hemolysis, platelet activation, and vWF degradation. Results: Bivalirudin and sodium bicarbonate adjunctive environment led to similar or improved hemocompatibility as compared to heparin‐containing environment—notably, decreased hemolysis (40 ± 20.8 mg/dL average decrease) and preserved platelet activity measured by P‐selectin exposure (8.0 ± 5.6% average increase). Conclusions: Our data supports the potential to create an overall heparin‐free approach simplifying anticoagulation management, offering potential for overall reduced bleeding risk and heparin‐related complications.
- Open Access
- 17 April 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (8) , 7386
Shear-Mediated Platelet Microparticles Demonstrate Phenotypic Heterogeneity as to Morphology, Receptor Distribution, and Hemostatic Function
Implantable Cardiovascular Therapeutic Devices (CTD), while lifesaving, impart supraphysiologic shear stress to platelets, resulting in thrombotic and bleeding coagulopathy. We previously demonstrated that shear-mediated platelet dysfunction is associated with downregulation of platelet GPIb-IX-V and αIIbβ3 receptors via generation of Platelet-Derived MicroParticles (PDMPs). Here, we test the hypothesis that sheared PDMPs manifest phenotypical heterogeneity of morphology and receptor surface expression and modulate platelet hemostatic function. Human gel-filtered platelets were exposed to continuous shear stress. Alterations of platelet morphology were visualized using transmission electron microscopy. Surface expression of platelet receptors and PDMP generation were quantified by flow cytometry. Thrombin generation was quantified spectrophotometrically, and platelet aggregation was measured by optical aggregometry. Shear stress promotes notable alterations in platelet morphology and ejection of distinctive types of PDMPs. Shear-mediated microvesiculation is associated with the remodeling of platelet receptors, with PDMPs expressing significantly higher levels of adhesion receptors (αIIbβ3, GPIX, PECAM-1, P-selectin, and PSGL-1) and agonist receptors (P2Y12 and PAR1). Sheared PDMPs promote thrombin generation and inhibit platelet aggregation induced by collagen and ADP. Sheared PDMPs demonstrate phenotypic heterogeneity as to morphology and defined patterns of surface receptors and impose a bidirectional effect on platelet hemostatic function. PDMP heterogeneity suggests that a range of mechanisms are operative in the microvesiculation process, contributing to CTD coagulopathy and posing opportunities for therapeutic manipulation.
- 17 April 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (8) , 7386
Open AccessShear-Mediated Platelet Microparticles Demonstrate Phenotypic Heterogeneity as to Morphology, Receptor Distribution, and Hemostatic Function
Implantable Cardiovascular Therapeutic Devices (CTD), while lifesaving, impart supraphysiologic shear stress to platelets, resulting in thrombotic and bleeding coagulopathy. We previously demonstrated that shear-mediated platelet dysfunction is associated with downregulation of platelet GPIb-IX-V and αIIbβ3 receptors via generation of Platelet-Derived MicroParticles (PDMPs). Here, we test the hypothesis that sheared PDMPs manifest phenotypical heterogeneity of morphology and receptor surface expression and modulate platelet hemostatic function. Human gel-filtered platelets were exposed to continuous shear stress. Alterations of platelet morphology were visualized using transmission electron microscopy. Surface expression of platelet receptors and PDMP generation were quantified by flow cytometry. Thrombin generation was quantified spectrophotometrically, and platelet aggregation was measured by optical aggregometry. Shear stress promotes notable alterations in platelet morphology and ejection of distinctive types of PDMPs. Shear-mediated microvesiculation is associated with the remodeling of platelet receptors, with PDMPs expressing significantly higher levels of adhesion receptors (αIIbβ3, GPIX, PECAM-1, P-selectin, and PSGL-1) and agonist receptors (P2Y12 and PAR1). Sheared PDMPs promote thrombin generation and inhibit platelet aggregation induced by collagen and ADP. Sheared PDMPs demonstrate phenotypic heterogeneity as to morphology and defined patterns of surface receptors and impose a bidirectional effect on platelet hemostatic function. PDMP heterogeneity suggests that a range of mechanisms are operative in the microvesiculation process, contributing to CTD coagulopathy and posing opportunities for therapeutic manipulation.
- 9 February 2023
- Published by Wiley in Artificial Organs
- Vol. 47 (6) , 971-981
Sodium bicarbonate alters protein stability and blood coagulability in a simulated Impella purge gap model
Background: The Impella® microaxial blood pumps utilize purge fluid containing heparin to prevent biofouling of internal surfaces. Purge fluid interfaces with blood or blood components at two notable internal locations: (1) 5–8 μm radial gap (“Radial Gap” or “Gap 1”) between the motor shaft and bearing, a site accessible by blood proteins or small molecules; and (2) 100 μm axial gap (“Axial Gap” or “Gap 2”) between the impeller rotor and bearing, the site of mixing with larger circulating blood components. Despite its efficacy, heparin in the purge fluid complicates overall patient anticoagulation management. Here, we investigate sodium bicarbonate as an alternative to heparin in the purge fluid in a simulated purge gap micro‐environment.Methods: To assess protein stability simulated at Gap 1, human serum albumin (HSA; 40 mg/ml) species were quantified utilizing size exclusion liquid chromatography (SEC‐HPLC) after stirring with purge fluid (5% dextrose in water (D5W) with heparin (25 U/ml) or sodium bicarbonate (25 or 50 mEq/L)) over a 24‐h period. pH measurements were taken immediately prior to stirring. Mixing between blood and purge fluid at Gap 2 was mimicked in vitro utilizing a 60:40 blood: purge fluid ratio. Purge fluid consisted of D5W with or without sodium bicarbonate (25 or 50 mEq/L). Human citrated blood samples were freshly collected with or without the addition of heparin (5 U/ml). Coagulability was determined via thromboelastography (TEG). pH measurements of blood mixtures were taken immediately before and after TEG analysis.Results: Sodium bicarbonate alone or synergistically with heparin was effective in increasing protein stability, increasing pH, and reducing coagulability. In the Gap 1 model, sodium bicarbonate led to preservation of HSA monomer after 24 h mixing, with monomer composing 88.3 ± 2.3% and 88.6 ± 0.9% of total HSA species for 25 or 50 mEq/L sodium bicarbonate, respectively. Only 60.4 ± 4.3% monomer was observed with D5W alone (p < 0.005). HSA aggregates and fragments were evident in heparin and D5W purge mixtures, but absent in sodium bicarbonate (25 and 50 mEq/L). pH of HSA mixtures significantly increased in the presence of sodium bicarbonate. In the Gap 2 model, combined heparin (5 U/ml) and sodium bicarbonate prolonged clotting time (TEG‐ACT), leading to an average increase of 795 ± 275 s (p = 0.04) and 846 243 s (p = 0.03). This trend of reduced coagulability was similarly observed in clot initiation time (R time), clot formation time (K time), and clotting rate (α angle). Blood mixture pH measurements increased with addition of sodium bicarbonate in both heparinized and non‐heparinized blood samples.Conclusion: Sodium bicarbonate in the purge fluid has the potential to significantly increase protein stability and reduce protein denaturation at the Impella® radial gap (Gap 1), while reducing blood coagulation at the Impella® axial gap (Gap 2). The influence of sodium bicarbonate on the biochemical environment of the purge fluid may ensure stable purge flow resistance and play a synergistic or supportive role in the purge gap micro‐environment when used with systemic anticoagulation.
- 9 February 2023
- Published by Wiley in Artificial Organs
- Vol. 47 (6) , 971-981
Sodium bicarbonate alters protein stability and blood coagulability in a simulated Impella purge gap model
Background: The Impella® microaxial blood pumps utilize purge fluid containing heparin to prevent biofouling of internal surfaces. Purge fluid interfaces with blood or blood components at two notable internal locations: (1) 5–8 μm radial gap (“Radial Gap” or “Gap 1”) between the motor shaft and bearing, a site accessible by blood proteins or small molecules; and (2) 100 μm axial gap (“Axial Gap” or “Gap 2”) between the impeller rotor and bearing, the site of mixing with larger circulating blood components. Despite its efficacy, heparin in the purge fluid complicates overall patient anticoagulation management. Here, we investigate sodium bicarbonate as an alternative to heparin in the purge fluid in a simulated purge gap micro‐environment.Methods: To assess protein stability simulated at Gap 1, human serum albumin (HSA; 40 mg/ml) species were quantified utilizing size exclusion liquid chromatography (SEC‐HPLC) after stirring with purge fluid (5% dextrose in water (D5W) with heparin (25 U/ml) or sodium bicarbonate (25 or 50 mEq/L)) over a 24‐h period. pH measurements were taken immediately prior to stirring. Mixing between blood and purge fluid at Gap 2 was mimicked in vitro utilizing a 60:40 blood: purge fluid ratio. Purge fluid consisted of D5W with or without sodium bicarbonate (25 or 50 mEq/L). Human citrated blood samples were freshly collected with or without the addition of heparin (5 U/ml). Coagulability was determined via thromboelastography (TEG). pH measurements of blood mixtures were taken immediately before and after TEG analysis.Results: Sodium bicarbonate alone or synergistically with heparin was effective in increasing protein stability, increasing pH, and reducing coagulability. In the Gap 1 model, sodium bicarbonate led to preservation of HSA monomer after 24 h mixing, with monomer composing 88.3 ± 2.3% and 88.6 ± 0.9% of total HSA species for 25 or 50 mEq/L sodium bicarbonate, respectively. Only 60.4 ± 4.3% monomer was observed with D5W alone (p < 0.005). HSA aggregates and fragments were evident in heparin and D5W purge mixtures, but absent in sodium bicarbonate (25 and 50 mEq/L). pH of HSA mixtures significantly increased in the presence of sodium bicarbonate. In the Gap 2 model, combined heparin (5 U/ml) and sodium bicarbonate prolonged clotting time (TEG‐ACT), leading to an average increase of 795 ± 275 s (p = 0.04) and 846 243 s (p = 0.03). This trend of reduced coagulability was similarly observed in clot initiation time (R time), clot formation time (K time), and clotting rate (α angle). Blood mixture pH measurements increased with addition of sodium bicarbonate in both heparinized and non‐heparinized blood samples.Conclusion: Sodium bicarbonate in the purge fluid has the potential to significantly increase protein stability and reduce protein denaturation at the Impella® radial gap (Gap 1), while reducing blood coagulation at the Impella® axial gap (Gap 2). The influence of sodium bicarbonate on the biochemical environment of the purge fluid may ensure stable purge flow resistance and play a synergistic or supportive role in the purge gap micro‐environment when used with systemic anticoagulation.
- Open Access
- 17 June 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (12) , 6173
Smart Phone-Based Motion Capture and Analysis: Importance of Operating Envelope Definition and Application to Clinical Use
Human movement is vital for life, with active engagement affording function, limiting disease, and improving quality; with loss resulting in disability; and the treatment and training leading to restoration and enhancement. To foster these endeavors a need exists for a simple and reliable method for the quantitation of movement, favorable for widespread user availability. We developed a Mobile Motion Capture system (MO2CA) employing a smart-phone and colored markers (2, 5, 10 mm) and here define its operating envelope in terms of: (1) the functional distance of marker detection (range), (2) the inter-target resolution and discrimination, (3) the mobile target detection, and (4) the impact of ambient illumination intensity. MO2CA was able to detect and discriminate: (1) single targets over a range of 1 to 18 ft, (2) multiple targets from 1 ft to 11 ft, with inter-target discrimination improving with an increasing target size, (3) moving targets, with minimal errors from 2 ft to 8 ft, and (4) targets within 1 to 18 ft, with an illumination of 100–300 lux. We then evaluated the utility of motion capture in quantitating regional-finger abduction/adduction and whole body–lateral flex motion, demonstrating a quantitative discrimination between normal and abnormal motion. Overall, our results demonstrate that MO2CA has a wide operating envelope with utility for the detection of human movements large and small, encompassing the whole body, body region, and extremity and digit movements. The definition of the effective operating envelope and utility of smart phone-based motion capture as described herein will afford accuracy and appropriate use for future application studies and serve as a general approach for defining the operational bounds of future video capture technologies that arise for potential clinical use.
- 17 June 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (12) , 6173
Open AccessSmart Phone-Based Motion Capture and Analysis: Importance of Operating Envelope Definition and Application to Clinical Use
Human movement is vital for life, with active engagement affording function, limiting disease, and improving quality; with loss resulting in disability; and the treatment and training leading to restoration and enhancement. To foster these endeavors a need exists for a simple and reliable method for the quantitation of movement, favorable for widespread user availability. We developed a Mobile Motion Capture system (MO2CA) employing a smart-phone and colored markers (2, 5, 10 mm) and here define its operating envelope in terms of: (1) the functional distance of marker detection (range), (2) the inter-target resolution and discrimination, (3) the mobile target detection, and (4) the impact of ambient illumination intensity. MO2CA was able to detect and discriminate: (1) single targets over a range of 1 to 18 ft, (2) multiple targets from 1 ft to 11 ft, with inter-target discrimination improving with an increasing target size, (3) moving targets, with minimal errors from 2 ft to 8 ft, and (4) targets within 1 to 18 ft, with an illumination of 100–300 lux. We then evaluated the utility of motion capture in quantitating regional-finger abduction/adduction and whole body–lateral flex motion, demonstrating a quantitative discrimination between normal and abnormal motion. Overall, our results demonstrate that MO2CA has a wide operating envelope with utility for the detection of human movements large and small, encompassing the whole body, body region, and extremity and digit movements. The definition of the effective operating envelope and utility of smart phone-based motion capture as described herein will afford accuracy and appropriate use for future application studies and serve as a general approach for defining the operational bounds of future video capture technologies that arise for potential clinical use.
- 16 June 2021
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 138 (43) , 51277
Hemocompatibility of polymers for use in vascular endoluminal implants
Implanted polymers for cardiovascular applications may function as structural supports, barriers, or provide a means for local drug delivery. Several thermoplastic biodegradable drug delivery polymers are potential candidates for blood‐contacting implant applications. For intravascular applications specifically, a criterion for material selection is the intrinsic hemocompatibility of the baseline polymer. As an initial screening approach for selection of polymers for in vivo use, thin films of polyesters: poly(ɛ‐caprolactone) (PCL), poly(lactic acid) (PLA), poly(lactic‐co‐glycolic acid) (PLGA); polyanhydrides: poly(fatty acid dimer‐co‐sebacic acid) (PFAD:SA) and poly(biscarboxyphenoxypropane‐co‐sebacic acid) (PCPP:SA); and poly(ethylene glycol) (PEG)‐ylated polyesters: PLA:PEG, PCL:PEG and PCL:PLA:PEG polymers were spin‐cast on glass cover slips and placed in an in vitro flow system exposing them at a controlled shear to overflowing human whole blood. Platelet adherence, aggregate formation, and thrombus formation, as well as leukocyte adherence were assessed following 5 min of flow. At 5 min of flow the rank order of materials, in terms of least to most thrombogenic was: PCL < PFAD:SA < PCPP:SA < PLGA < PLA. All PEGylated materials, in general, had less thrombus formation than baseline unmodified materials.
- 16 June 2021
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 138 (43) , 51277
Hemocompatibility of polymers for use in vascular endoluminal implants
Implanted polymers for cardiovascular applications may function as structural supports, barriers, or provide a means for local drug delivery. Several thermoplastic biodegradable drug delivery polymers are potential candidates for blood‐contacting implant applications. For intravascular applications specifically, a criterion for material selection is the intrinsic hemocompatibility of the baseline polymer. As an initial screening approach for selection of polymers for in vivo use, thin films of polyesters: poly(ɛ‐caprolactone) (PCL), poly(lactic acid) (PLA), poly(lactic‐co‐glycolic acid) (PLGA); polyanhydrides: poly(fatty acid dimer‐co‐sebacic acid) (PFAD:SA) and poly(biscarboxyphenoxypropane‐co‐sebacic acid) (PCPP:SA); and poly(ethylene glycol) (PEG)‐ylated polyesters: PLA:PEG, PCL:PEG and PCL:PLA:PEG polymers were spin‐cast on glass cover slips and placed in an in vitro flow system exposing them at a controlled shear to overflowing human whole blood. Platelet adherence, aggregate formation, and thrombus formation, as well as leukocyte adherence were assessed following 5 min of flow. At 5 min of flow the rank order of materials, in terms of least to most thrombogenic was: PCL < PFAD:SA < PCPP:SA < PLGA < PLA. All PEGylated materials, in general, had less thrombus formation than baseline unmodified materials.
- 19 April 2021
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 4 (5) , 4084-4093
Patterned Electrospinning: A Method of Generating Defined Fibrous Constructs Influencing Cell Adhesion and Retention
A critical component of tissue engineering is the ability to functionally replace native tissue stroma. Electrospinning is a technique capable of forming fibrous constructs with a high surface area for increased cell–material interaction and enhanced biocompatibility. However, physical and biological properties of electrospun scaffolds are limited by design controllability on a macroscale. We developed a methodology for generating electrospun scaffolds with defined patterns and topographic features to influence physical properties and biological interactions. Five unique design electrospinning target collectors were fabricated to allow for generation of defined polymeric scaffold patterns including lines, sinusoids, squares, zigzags, and solid. Poly(lactic-co-glycolic) acid was electrospun under identical conditions utilizing these varied targets, and constructs generated were examined as to their physical configuration, mechanical and chemical properties, and their ability to foster vascular smooth muscle cell adhesion and retention at 24 h. Modifying collector designs led to significant differences in fiber target coverage ranging from 300 mm2 for solid (100% of the target area) to 217.8 mm2 for lines (72.6% of the target area). Measured fiber excess, residual open area, and contact angle (hydrophobicity) followed the same trend as fiber target coverage with respect to the collector pattern: lines > sinusoids > squares > zigzags > solid. Similarly, the line design allowed for the greatest cell adhesion and retention (258 ± 31 cells), whereas solid exhibited the lowest (150 ± 15 cells); p < 0.05. There was a strong direct correlation of cell adhesion to construct residual open area (R2 = 0.94), normalized fiber excess (R2 = 0.99), and fiber grammage (R2 = 0.72), with an inverse relationship to fiber target coverage (R2 = 0.94). Our results demonstrate the ability to utilize patterned collectors for modifying macroscopic and microscopic electrospun scaffold features, which directly impact cell adhesion and retention, offering translational utility for designing specific tissue constructs.
- 19 April 2021
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 4 (5) , 4084-4093
Patterned Electrospinning: A Method of Generating Defined Fibrous Constructs Influencing Cell Adhesion and Retention
A critical component of tissue engineering is the ability to functionally replace native tissue stroma. Electrospinning is a technique capable of forming fibrous constructs with a high surface area for increased cell–material interaction and enhanced biocompatibility. However, physical and biological properties of electrospun scaffolds are limited by design controllability on a macroscale. We developed a methodology for generating electrospun scaffolds with defined patterns and topographic features to influence physical properties and biological interactions. Five unique design electrospinning target collectors were fabricated to allow for generation of defined polymeric scaffold patterns including lines, sinusoids, squares, zigzags, and solid. Poly(lactic-co-glycolic) acid was electrospun under identical conditions utilizing these varied targets, and constructs generated were examined as to their physical configuration, mechanical and chemical properties, and their ability to foster vascular smooth muscle cell adhesion and retention at 24 h. Modifying collector designs led to significant differences in fiber target coverage ranging from 300 mm2 for solid (100% of the target area) to 217.8 mm2 for lines (72.6% of the target area). Measured fiber excess, residual open area, and contact angle (hydrophobicity) followed the same trend as fiber target coverage with respect to the collector pattern: lines > sinusoids > squares > zigzags > solid. Similarly, the line design allowed for the greatest cell adhesion and retention (258 ± 31 cells), whereas solid exhibited the lowest (150 ± 15 cells); p < 0.05. There was a strong direct correlation of cell adhesion to construct residual open area (R2 = 0.94), normalized fiber excess (R2 = 0.99), and fiber grammage (R2 = 0.72), with an inverse relationship to fiber target coverage (R2 = 0.94). Our results demonstrate the ability to utilize patterned collectors for modifying macroscopic and microscopic electrospun scaffold features, which directly impact cell adhesion and retention, offering translational utility for designing specific tissue constructs.
- 12 April 2021
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 44 (12) , 1013-1020
Characterization of the competing role of surface-contact and shear stress on platelet activation in the setting of blood contacting devices
Supraphysiological shear stress and surface-contact are recognized as driving mechanisms of platelet activation (PA) in blood contacting devices (BCDs). However, the competing role of these mechanisms in triggering thrombogenic events is poorly understood. Here, we characterized the dynamics of PA in response to the combined effect of shear stress and material exposure. Human platelets were stimulated with different levels of shear stress (500, 750, 1000 dynes/cm2) over a range of exposure times (10, 20, and 30 min) within capillary tubes made of various polymeric materials. Polyethylene (PE), polytetrafluoroethylene (PTFE), ethylene tetrafluoroethylene (ETFE), and polyether ether ketone (PEEK), used for BCDs fabrication, were investigated as compared to glass and thromboresistant Sigma™-coated glass. PA was quantified using the Platelet Activity State assay. Our results indicate that mechanical stimulation and polymer surface-contact both significantly contribute to PA. Notably, the contribution of the mechanical stimulus ranges between +36% and +43%, while that associated with polymer surface-contact ranges from +48% to +59%, depending on the exposure time. In more detail, our results indicate that: (i) PA increases with increasing shear stress magnitude; (ii) PA has a non-linear, time-dependent relationship to exposure time; (iii) PA is largely influenced by biomaterials, with PE and PEEK having respectively the lowest and highest prothrombotic potential; (iv) the effects of polymer surface-contact and shear stress are not correlated and can be studied separately. Our results suggest the importance of incorporating the evaluation of platelet activation driven by the combined effect of shear stress and polymer surface-contact for the comprehensive assessment, and eventually minimization, of BCDs thrombogenic potential.
- 12 April 2021
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 44 (12) , 1013-1020
Characterization of the competing role of surface-contact and shear stress on platelet activation in the setting of blood contacting devices
Supraphysiological shear stress and surface-contact are recognized as driving mechanisms of platelet activation (PA) in blood contacting devices (BCDs). However, the competing role of these mechanisms in triggering thrombogenic events is poorly understood. Here, we characterized the dynamics of PA in response to the combined effect of shear stress and material exposure. Human platelets were stimulated with different levels of shear stress (500, 750, 1000 dynes/cm2) over a range of exposure times (10, 20, and 30 min) within capillary tubes made of various polymeric materials. Polyethylene (PE), polytetrafluoroethylene (PTFE), ethylene tetrafluoroethylene (ETFE), and polyether ether ketone (PEEK), used for BCDs fabrication, were investigated as compared to glass and thromboresistant Sigma™-coated glass. PA was quantified using the Platelet Activity State assay. Our results indicate that mechanical stimulation and polymer surface-contact both significantly contribute to PA. Notably, the contribution of the mechanical stimulus ranges between +36% and +43%, while that associated with polymer surface-contact ranges from +48% to +59%, depending on the exposure time. In more detail, our results indicate that: (i) PA increases with increasing shear stress magnitude; (ii) PA has a non-linear, time-dependent relationship to exposure time; (iii) PA is largely influenced by biomaterials, with PE and PEEK having respectively the lowest and highest prothrombotic potential; (iv) the effects of polymer surface-contact and shear stress are not correlated and can be studied separately. Our results suggest the importance of incorporating the evaluation of platelet activation driven by the combined effect of shear stress and polymer surface-contact for the comprehensive assessment, and eventually minimization, of BCDs thrombogenic potential.
- 24 December 2020
- Published by Elsevier in Experimental Cell Research
- Vol. 399 (1) , 112447
Vascular endothelial and smooth muscle cell galvanotactic response and differential migratory behavior
- 24 December 2020
- Published by Elsevier in Experimental Cell Research
- Vol. 399 (1) , 112447
Vascular endothelial and smooth muscle cell galvanotactic response and differential migratory behavior
- Open Access
- 27 February 2020
- Published by Springer Nature in BMC Biomedical Engineering
- Vol. 2 (1) , 1-15
Human motion component and envelope characterization via wireless wearable sensors
Background: The characterization of limb biomechanics has broad implications for analyzing and managing motion in aging, sports, and disease. Motion capture videography and on-body wearable sensors are powerful tools for characterizing linear and angular motions of the body, though are often cumbersome, limited in detection, and largely non-portable. Here we examine the feasibility of utilizing an advanced wearable sensor, fabricated with stretchable electronics, to characterize linear and angular movements of the human arm for clinical feedback. A wearable skin-adhesive patch with embedded accelerometer and gyroscope (BioStampRC, MC10 Inc.) was applied to the volar surface of the forearm of healthy volunteers. Arms were extended/flexed for the range of motion of three different regimes: 1) horizontal adduction/abduction 2) flexion/extension 3) vertical abduction. Data were streamed and recorded revealing the signal “pattern” of movement in three separate axes. Additional signal processing and filtering afforded the ability to visualize these motions in each plane of the body; and the 3-dimensional motion envelope of the arm. Results: Each of the three motion regimes studied had a distinct pattern – with identifiable qualitative and quantitative differences. Integration of all three movement regimes allowed construction of a “motion envelope,” defining and quantifying motion (range and shape – including the outer perimeter of the extreme of motion – i.e. the envelope) of the upper extremity. The linear and rotational motion results from multiple arm motions match measurements taken with videography and benchtop goniometer. Conclusions: A conformal, stretchable electronic motion sensor effectively captures limb motion in multiple degrees of freedom, allowing generation of characteristic signatures which may be readily recorded, stored, and analyzed. Wearable conformal skin adherent sensor patchs allow on-body, mobile, personalized determination of motion and flexibility parameters. These sensors allow motion assessment while mobile, free of a fixed laboratory environment, with utility in the field, home, or hospital. These sensors and mode of analysis hold promise for providing digital “motion biomarkers” of health and disease.
- 27 February 2020
- Published by Springer Nature in BMC Biomedical Engineering
- Vol. 2 (1) , 1-15
Open AccessHuman motion component and envelope characterization via wireless wearable sensors
Background: The characterization of limb biomechanics has broad implications for analyzing and managing motion in aging, sports, and disease. Motion capture videography and on-body wearable sensors are powerful tools for characterizing linear and angular motions of the body, though are often cumbersome, limited in detection, and largely non-portable. Here we examine the feasibility of utilizing an advanced wearable sensor, fabricated with stretchable electronics, to characterize linear and angular movements of the human arm for clinical feedback. A wearable skin-adhesive patch with embedded accelerometer and gyroscope (BioStampRC, MC10 Inc.) was applied to the volar surface of the forearm of healthy volunteers. Arms were extended/flexed for the range of motion of three different regimes: 1) horizontal adduction/abduction 2) flexion/extension 3) vertical abduction. Data were streamed and recorded revealing the signal “pattern” of movement in three separate axes. Additional signal processing and filtering afforded the ability to visualize these motions in each plane of the body; and the 3-dimensional motion envelope of the arm. Results: Each of the three motion regimes studied had a distinct pattern – with identifiable qualitative and quantitative differences. Integration of all three movement regimes allowed construction of a “motion envelope,” defining and quantifying motion (range and shape – including the outer perimeter of the extreme of motion – i.e. the envelope) of the upper extremity. The linear and rotational motion results from multiple arm motions match measurements taken with videography and benchtop goniometer. Conclusions: A conformal, stretchable electronic motion sensor effectively captures limb motion in multiple degrees of freedom, allowing generation of characteristic signatures which may be readily recorded, stored, and analyzed. Wearable conformal skin adherent sensor patchs allow on-body, mobile, personalized determination of motion and flexibility parameters. These sensors allow motion assessment while mobile, free of a fixed laboratory environment, with utility in the field, home, or hospital. These sensors and mode of analysis hold promise for providing digital “motion biomarkers” of health and disease.