Characterization of the competing role of surface-contact and shear stress on platelet activation in the setting of blood contacting devices
- 12 April 2021
- journal article
- research article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 44 (12) , 1013-1020
Abstract
Supraphysiological shear stress and surface-contact are recognized as driving mechanisms of platelet activation (PA) in blood contacting devices (BCDs). However, the competing role of these mechanisms in triggering thrombogenic events is poorly understood. Here, we characterized the dynamics of PA in response to the combined effect of shear stress and material exposure. Human platelets were stimulated with different levels of shear stress (500, 750, 1000 dynes/cm2) over a range of exposure times (10, 20, and 30 min) within capillary tubes made of various polymeric materials. Polyethylene (PE), polytetrafluoroethylene (PTFE), ethylene tetrafluoroethylene (ETFE), and polyether ether ketone (PEEK), used for BCDs fabrication, were investigated as compared to glass and thromboresistant Sigma™-coated glass. PA was quantified using the Platelet Activity State assay. Our results indicate that mechanical stimulation and polymer surface-contact both significantly contribute to PA. Notably, the contribution of the mechanical stimulus ranges between +36% and +43%, while that associated with polymer surface-contact ranges from +48% to +59%, depending on the exposure time. In more detail, our results indicate that: (i) PA increases with increasing shear stress magnitude; (ii) PA has a non-linear, time-dependent relationship to exposure time; (iii) PA is largely influenced by biomaterials, with PE and PEEK having respectively the lowest and highest prothrombotic potential; (iv) the effects of polymer surface-contact and shear stress are not correlated and can be studied separately. Our results suggest the importance of incorporating the evaluation of platelet activation driven by the combined effect of shear stress and polymer surface-contact for the comprehensive assessment, and eventually minimization, of BCDs thrombogenic potential.Keywords
Funding Information
- Arizona Center for Accelerated BioMedical Innovation
- Fondazione Cariplo (2015-1044)
This publication has 44 references indexed in Scilit:
- Evaluation of Shear-Induced Platelet Activation Models Under Constant and Dynamic Shear Stress Loading Conditions Relevant to DevicesAnnals of Biomedical Engineering, 2013
- Computational evaluation of the thrombogenic potential of a hollow-fiber oxygenator with integrated heat exchanger during extracorporeal circulationBiomechanics and Modeling in Mechanobiology, 2012
- Device Thrombogenicity Emulation: A Novel Method for Optimizing Mechanical Circulatory Support Device ThromboresistancePLOS ONE, 2012
- Delineating the roles of the GPIIb/IIIa and GP-Ib-IX-V platelet receptors in mediating platelet adhesion to adsorbed fibrinogen and albuminBiomaterials, 2011
- Platelet Dysfunction in Outpatients With Left Ventricular Assist DevicesThe Annals of Thoracic Surgery, 2009
- The Wettability of Fluoropolymer Surfaces: Influence of Surface DipolesLangmuir, 2008
- Biological effects of dynamic shear stress in cardiovascular pathologies and devicesExpert Review of Medical Devices, 2008
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- Effects of surface roughness on anti-thrombogenicity of diamond-like carbon filmsDiamond and Related Materials, 2007
- Acetylated Prothrombin as a Substrate in the Measurement of the Procoagulant Activity of Platelets: Elimination of the Feedback Activation of Platelets by ThrombinAnalytical Biochemistry, 1999