Danying Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Danying Hu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Blake Hannaford
BioRobotics Lab (BRL), Electrical and Computer Engineering, University of Washington, 185 Stevens Way, Seattle Washington 98195, United States
4 shared publications - Eric J. Seibel
Department of Mechanical Engineering, University of Washington, Seattle, USA
4 shared publications - Yuanzheng Gong
Human Photonics Laboratory, Department of Mechanical Engineering, University of Washington, Seattle, WA, USA
3 shared publications - Laligam N. Sekhar
Department of Neurological Surgery, University of Washington, Seattle, Washington, USA
1 shared publication - Yuanzheng Gong
Human Photonics Laboratory, Department of Mechanical Engineering, University of Washington, Seattle, USA
1 shared publication
Latest Publications
- 3 November 2017
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 14 (1)
Semi‐autonomous image‐guided brain tumour resection using an integrated robotic system: A bench‐top study
Background: Complete brain tumour resection is an extremely critical factor for patients' survival rate and long‐term quality of life. This paper introduces a prototype medical robotic system that aims to automatically detect and clean up brain tumour residues after the removal of tumour bulk through conventional surgery.Methods: We focus on the development of an integrated surgical robotic system for image‐guided robotic brain surgery. The Behavior Tree framework is explored to coordinate cross‐platform medical subtasks.Results: The integrated system was tested on a simulated laboratory platform. Results and performance indicate the feasibility of supervised semi‐automation for residual brain tumour ablation in a simulated surgical cavity with sub‐millimetre accuracy. The modularity in the control architecture allows straightforward integration of further medical devices.Conclusions: This work presents a semi‐automated laboratory setup, simulating an intraoperative robotic neurosurgical procedure with real‐time endoscopic image guidance and provides a foundation for the future transition from engineering approaches to clinical application.
- 3 November 2017
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 14 (1)
Semi‐autonomous image‐guided brain tumour resection using an integrated robotic system: A bench‐top study
Background: Complete brain tumour resection is an extremely critical factor for patients' survival rate and long‐term quality of life. This paper introduces a prototype medical robotic system that aims to automatically detect and clean up brain tumour residues after the removal of tumour bulk through conventional surgery.Methods: We focus on the development of an integrated surgical robotic system for image‐guided robotic brain surgery. The Behavior Tree framework is explored to coordinate cross‐platform medical subtasks.Results: The integrated system was tested on a simulated laboratory platform. Results and performance indicate the feasibility of supervised semi‐automation for residual brain tumour ablation in a simulated surgical cavity with sub‐millimetre accuracy. The modularity in the control architecture allows straightforward integration of further medical devices.Conclusions: This work presents a semi‐automated laboratory setup, simulating an intraoperative robotic neurosurgical procedure with real‐time endoscopic image guidance and provides a foundation for the future transition from engineering approaches to clinical application.
- Open Access
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015, 2639-2645
Path planning for semi-automated simulated robotic neurosurgery
This paper considers the semi-automated robotic surgical procedure for removing the brain tumor margins, where the manual operation is a tedious and time-consuming task for surgeons. We present robust path planning methods for robotic ablation of tumor residues in various shapes, which are represented in point-clouds instead of analytical geometry. Along with the path plans, corresponding metrics are also delivered to the surgeon for selecting the optimal candidate in the automated robotic ablation. The selected path plan is then executed and tested on RAVEN™ II surgical robot platform as part of the semi-automated robotic brain tumor ablation surgery in a simulated tissue phantom.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015, 2639-2645
Open AccessPath planning for semi-automated simulated robotic neurosurgery
This paper considers the semi-automated robotic surgical procedure for removing the brain tumor margins, where the manual operation is a tedious and time-consuming task for surgeons. We present robust path planning methods for robotic ablation of tumor residues in various shapes, which are represented in point-clouds instead of analytical geometry. Along with the path plans, corresponding metrics are also delivered to the surgeon for selecting the optimal candidate in the automated robotic ablation. The selected path plan is then executed and tested on RAVEN™ II surgical robot platform as part of the semi-automated robotic brain tumor ablation surgery in a simulated tissue phantom.
- Open Access
- 18 March 2015
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 9415, 94150C-83
Toward real-time endoscopically-guided robotic navigation based on a 3D virtual surgical field model
The challenge is to accurately guide the surgical tool within the three-dimensional (3D) surgical field for roboticallyassisted operations such as tumor margin removal from a debulked brain tumor cavity. The proposed technique is 3D image-guided surgical navigation based on matching intraoperative video frames to a 3D virtual model of the surgical field. A small laser-scanning endoscopic camera was attached to a mock minimally-invasive surgical tool that was manipulated toward a region of interest (residual tumor) within a phantom of a debulked brain tumor. Video frames from the endoscope provided features that were matched to the 3D virtual model, which were reconstructed earlier by raster scanning over the surgical field. Camera pose (position and orientation) is recovered by implementing a constrained bundle adjustment algorithm. Navigational error during the approach to fluorescence target (residual tumor) is determined by comparing the calculated camera pose to the measured camera pose using a micro-positioning stage. From these preliminary results, computation efficiency of the algorithm in MATLAB code is near real-time (2.5 sec for each estimation of pose), which can be improved by implementation in C++. Error analysis produced 3-mm distance error and 2.5 degree of orientation error on average. The sources of these errors come from 1) inaccuracy of the 3D virtual model, generated on a calibrated RAVEN robotic platform with stereo tracking; 2) inaccuracy of endoscope intrinsic parameters, such as focal length; and 3) any endoscopic image distortion from scanning irregularities. This work demonstrates feasibility of micro-camera 3D guidance of a robotic surgical tool.
- 18 March 2015
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 9415, 94150C-83
Open AccessToward real-time endoscopically-guided robotic navigation based on a 3D virtual surgical field model
The challenge is to accurately guide the surgical tool within the three-dimensional (3D) surgical field for roboticallyassisted operations such as tumor margin removal from a debulked brain tumor cavity. The proposed technique is 3D image-guided surgical navigation based on matching intraoperative video frames to a 3D virtual model of the surgical field. A small laser-scanning endoscopic camera was attached to a mock minimally-invasive surgical tool that was manipulated toward a region of interest (residual tumor) within a phantom of a debulked brain tumor. Video frames from the endoscope provided features that were matched to the 3D virtual model, which were reconstructed earlier by raster scanning over the surgical field. Camera pose (position and orientation) is recovered by implementing a constrained bundle adjustment algorithm. Navigational error during the approach to fluorescence target (residual tumor) is determined by comparing the calculated camera pose to the measured camera pose using a micro-positioning stage. From these preliminary results, computation efficiency of the algorithm in MATLAB code is near real-time (2.5 sec for each estimation of pose), which can be improved by implementation in C++. Error analysis produced 3-mm distance error and 2.5 degree of orientation error on average. The sources of these errors come from 1) inaccuracy of the 3D virtual model, generated on a calibrated RAVEN robotic platform with stereo tracking; 2) inaccuracy of endoscope intrinsic parameters, such as focal length; and 3) any endoscopic image distortion from scanning irregularities. This work demonstrates feasibility of micro-camera 3D guidance of a robotic surgical tool.
- Open Access
- 1 October 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 1 (3) , 035002
Accurate three-dimensional virtual reconstruction of surgical field using calibrated trajectories of an image-guided medical robot
Brain tumor margin removal is challenging because diseased tissue is often visually indistinguishable from healthy tissue. Leaving residual tumor leads to decreased survival, and removing normal tissue causes life-long neurological deficits. Thus, a surgical robotics system with a high degree of dexterity, accurate navigation, and highly precise resection is an ideal candidate for image-guided removal of fluorescently labeled brain tumor cells. To image, we developed a scanning fiber endoscope (SFE) which acquires concurrent reflectance and fluorescence wide-field images at a high resolution. This miniature flexible endoscope was affixed to the arm of a RAVEN II surgical robot providing programmable motion with feedback control using stereo-pair surveillance cameras. To verify the accuracy of the three-dimensional (3-D) reconstructed surgical field, a multimodal physical-sized model of debulked brain tumor was used to obtain the 3-D locations of residual tumor for robotic path planning to remove fluorescent cells. Such reconstruction is repeated intraoperatively during margin clean-up so the algorithm efficiency and accuracy are important to the robotically assisted surgery. Experimental results indicate that the time for creating this 3-D surface can be reduced to one-third by using known trajectories of a robot arm, and the error from the reconstructed phantom is within 0.67 mm in average compared to the model design.
- 1 October 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 1 (3) , 035002
Open AccessAccurate three-dimensional virtual reconstruction of surgical field using calibrated trajectories of an image-guided medical robot
Brain tumor margin removal is challenging because diseased tissue is often visually indistinguishable from healthy tissue. Leaving residual tumor leads to decreased survival, and removing normal tissue causes life-long neurological deficits. Thus, a surgical robotics system with a high degree of dexterity, accurate navigation, and highly precise resection is an ideal candidate for image-guided removal of fluorescently labeled brain tumor cells. To image, we developed a scanning fiber endoscope (SFE) which acquires concurrent reflectance and fluorescence wide-field images at a high resolution. This miniature flexible endoscope was affixed to the arm of a RAVEN II surgical robot providing programmable motion with feedback control using stereo-pair surveillance cameras. To verify the accuracy of the three-dimensional (3-D) reconstructed surgical field, a multimodal physical-sized model of debulked brain tumor was used to obtain the 3-D locations of residual tumor for robotic path planning to remove fluorescent cells. Such reconstruction is repeated intraoperatively during margin clean-up so the algorithm efficiency and accuracy are important to the robotically assisted surgery. Experimental results indicate that the time for creating this 3-D surface can be reduced to one-third by using known trajectories of a robot arm, and the error from the reconstructed phantom is within 0.67 mm in average compared to the model design.