Yuanzheng Gong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuanzheng Gong has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Blake Hannaford
BioRobotics Lab (BRL), Electrical and Computer Engineering, University of Washington, 185 Stevens Way, Seattle Washington 98195, United States
3 shared publications - Danying Hu
Biorobotics Laboratory, Department of Electrical Engineering, University of Washington, Seattle, WA, USA
3 shared publications - Eric J. Seibel
Department of Mechanical Engineering, University of Washington, Seattle, USA
3 shared publications - Laligam N. Sekhar
Department of Neurological Surgery, University of Washington, Seattle, Washington, USA
1 shared publication W. Jong Yoon
Department of Mechanical and Industrial Engineering, Qatar University, Doha, Qatar
1 shared publicationXianming Ye
Department of Mechanical and Industrial Engineering, Qatar University, Doha, Qatar
1 shared publication
Latest Publications
- 3 November 2017
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 14 (1)
Semi‐autonomous image‐guided brain tumour resection using an integrated robotic system: A bench‐top study
Background: Complete brain tumour resection is an extremely critical factor for patients' survival rate and long‐term quality of life. This paper introduces a prototype medical robotic system that aims to automatically detect and clean up brain tumour residues after the removal of tumour bulk through conventional surgery.Methods: We focus on the development of an integrated surgical robotic system for image‐guided robotic brain surgery. The Behavior Tree framework is explored to coordinate cross‐platform medical subtasks.Results: The integrated system was tested on a simulated laboratory platform. Results and performance indicate the feasibility of supervised semi‐automation for residual brain tumour ablation in a simulated surgical cavity with sub‐millimetre accuracy. The modularity in the control architecture allows straightforward integration of further medical devices.Conclusions: This work presents a semi‐automated laboratory setup, simulating an intraoperative robotic neurosurgical procedure with real‐time endoscopic image guidance and provides a foundation for the future transition from engineering approaches to clinical application.
- 3 November 2017
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 14 (1)
Semi‐autonomous image‐guided brain tumour resection using an integrated robotic system: A bench‐top study
Background: Complete brain tumour resection is an extremely critical factor for patients' survival rate and long‐term quality of life. This paper introduces a prototype medical robotic system that aims to automatically detect and clean up brain tumour residues after the removal of tumour bulk through conventional surgery.Methods: We focus on the development of an integrated surgical robotic system for image‐guided robotic brain surgery. The Behavior Tree framework is explored to coordinate cross‐platform medical subtasks.Results: The integrated system was tested on a simulated laboratory platform. Results and performance indicate the feasibility of supervised semi‐automation for residual brain tumour ablation in a simulated surgical cavity with sub‐millimetre accuracy. The modularity in the control architecture allows straightforward integration of further medical devices.Conclusions: This work presents a semi‐automated laboratory setup, simulating an intraoperative robotic neurosurgical procedure with real‐time endoscopic image guidance and provides a foundation for the future transition from engineering approaches to clinical application.
- Open Access
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015, 2639-2645
Path planning for semi-automated simulated robotic neurosurgery
This paper considers the semi-automated robotic surgical procedure for removing the brain tumor margins, where the manual operation is a tedious and time-consuming task for surgeons. We present robust path planning methods for robotic ablation of tumor residues in various shapes, which are represented in point-clouds instead of analytical geometry. Along with the path plans, corresponding metrics are also delivered to the surgeon for selecting the optimal candidate in the automated robotic ablation. The selected path plan is then executed and tested on RAVEN™ II surgical robot platform as part of the semi-automated robotic brain tumor ablation surgery in a simulated tissue phantom.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015, 2639-2645
Open AccessPath planning for semi-automated simulated robotic neurosurgery
This paper considers the semi-automated robotic surgical procedure for removing the brain tumor margins, where the manual operation is a tedious and time-consuming task for surgeons. We present robust path planning methods for robotic ablation of tumor residues in various shapes, which are represented in point-clouds instead of analytical geometry. Along with the path plans, corresponding metrics are also delivered to the surgeon for selecting the optimal candidate in the automated robotic ablation. The selected path plan is then executed and tested on RAVEN™ II surgical robot platform as part of the semi-automated robotic brain tumor ablation surgery in a simulated tissue phantom.
- 28 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 21 (2) , 993-1003
Development of Multisegment Steering Mechanism and 3-D Panorama for Automated Bladder Surveillance System
A cystoscope is an invaluable tool for bladder cancer surveillance and lower urinary tract pathology diagnosis. The performance of cystoscopy can be improved by automating the procedure to ensure rapid and complete inspection, having a predicted pathway for imaging. This paper proposes a versatile, wire-driven, multisegment mechanism for steering an imaging probe to follow optimal, preprogrammed scan trajectories. A novel flexible imaging probe scanning fiber endoscope (SFE) of 1.2 mm in diameter generates high-quality reflectance or fluorescent images. A 3-D panoramic reconstruction view of the bladder is generated by custom software to confirm comprehensive surveillance and improve clinical efficiency. The kinematics and controllability of the proposed mechanism are analyzed. The multiple degrees-of-freedom of the mechanism provide the advantage of maintaining the camera perpendicular to the bladder wall with a safety distance. The measured experimental results show 8.1% and 5.1% tip position and orientation errors, respectively, to the theoretical simulation predictions. Within a synthetic bladder phantom made from patient-specific geometry information, the apparatus is able to generate a 3-D panorama of about 60% of the bladder's inner surface, while accepting 50% image overlap between adjacent images. The novel imaging capability of the SFE, combined with a robotized multisegment steering mechanism and an image stitching software, proposes potential advancements to the multimodal 3-D panorama of the bladder.
- 28 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 21 (2) , 993-1003
Development of Multisegment Steering Mechanism and 3-D Panorama for Automated Bladder Surveillance System
A cystoscope is an invaluable tool for bladder cancer surveillance and lower urinary tract pathology diagnosis. The performance of cystoscopy can be improved by automating the procedure to ensure rapid and complete inspection, having a predicted pathway for imaging. This paper proposes a versatile, wire-driven, multisegment mechanism for steering an imaging probe to follow optimal, preprogrammed scan trajectories. A novel flexible imaging probe scanning fiber endoscope (SFE) of 1.2 mm in diameter generates high-quality reflectance or fluorescent images. A 3-D panoramic reconstruction view of the bladder is generated by custom software to confirm comprehensive surveillance and improve clinical efficiency. The kinematics and controllability of the proposed mechanism are analyzed. The multiple degrees-of-freedom of the mechanism provide the advantage of maintaining the camera perpendicular to the bladder wall with a safety distance. The measured experimental results show 8.1% and 5.1% tip position and orientation errors, respectively, to the theoretical simulation predictions. Within a synthetic bladder phantom made from patient-specific geometry information, the apparatus is able to generate a 3-D panorama of about 60% of the bladder's inner surface, while accepting 50% image overlap between adjacent images. The novel imaging capability of the SFE, combined with a robotized multisegment steering mechanism and an image stitching software, proposes potential advancements to the multimodal 3-D panorama of the bladder.
- Open Access
- 1 October 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 1 (3) , 035002
Accurate three-dimensional virtual reconstruction of surgical field using calibrated trajectories of an image-guided medical robot
Brain tumor margin removal is challenging because diseased tissue is often visually indistinguishable from healthy tissue. Leaving residual tumor leads to decreased survival, and removing normal tissue causes life-long neurological deficits. Thus, a surgical robotics system with a high degree of dexterity, accurate navigation, and highly precise resection is an ideal candidate for image-guided removal of fluorescently labeled brain tumor cells. To image, we developed a scanning fiber endoscope (SFE) which acquires concurrent reflectance and fluorescence wide-field images at a high resolution. This miniature flexible endoscope was affixed to the arm of a RAVEN II surgical robot providing programmable motion with feedback control using stereo-pair surveillance cameras. To verify the accuracy of the three-dimensional (3-D) reconstructed surgical field, a multimodal physical-sized model of debulked brain tumor was used to obtain the 3-D locations of residual tumor for robotic path planning to remove fluorescent cells. Such reconstruction is repeated intraoperatively during margin clean-up so the algorithm efficiency and accuracy are important to the robotically assisted surgery. Experimental results indicate that the time for creating this 3-D surface can be reduced to one-third by using known trajectories of a robot arm, and the error from the reconstructed phantom is within 0.67 mm in average compared to the model design.
- 1 October 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 1 (3) , 035002
Open AccessAccurate three-dimensional virtual reconstruction of surgical field using calibrated trajectories of an image-guided medical robot
Brain tumor margin removal is challenging because diseased tissue is often visually indistinguishable from healthy tissue. Leaving residual tumor leads to decreased survival, and removing normal tissue causes life-long neurological deficits. Thus, a surgical robotics system with a high degree of dexterity, accurate navigation, and highly precise resection is an ideal candidate for image-guided removal of fluorescently labeled brain tumor cells. To image, we developed a scanning fiber endoscope (SFE) which acquires concurrent reflectance and fluorescence wide-field images at a high resolution. This miniature flexible endoscope was affixed to the arm of a RAVEN II surgical robot providing programmable motion with feedback control using stereo-pair surveillance cameras. To verify the accuracy of the three-dimensional (3-D) reconstructed surgical field, a multimodal physical-sized model of debulked brain tumor was used to obtain the 3-D locations of residual tumor for robotic path planning to remove fluorescent cells. Such reconstruction is repeated intraoperatively during margin clean-up so the algorithm efficiency and accuracy are important to the robotically assisted surgery. Experimental results indicate that the time for creating this 3-D surface can be reduced to one-third by using known trajectories of a robot arm, and the error from the reconstructed phantom is within 0.67 mm in average compared to the model design.