Alex C. Valach
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Alex C. Valach has a total of 374 co-authors. Here are the top co-authors by number of shared publications:
- Eiko Nemitz
UK Centre for Ecology & Hydrology, Bush Estate, Penicuik, EH26 0QB, UK
13 shared publications - Kuno Kasak
Department of Geography, University of Tartu, Tartu, Estonia
9 shared publications - Camilo Rey-Sanchez
Department of Environmental Science, Policy and Management, University of California, Berkeley, CA, USA
8 shared publications - Daphne Szutu
Department of Environmental Science, Policy, and Management University of California 130 Mulford Hall Berkeley CA 94720 U.S.A.
8 shared publications - Dennis Baldocchi
Department of Environmental Science, Policy and Management, University of California, Berkeley, CA 94720, USA
8 shared publications - Kyle S. Hemes
Woods Institute for the Environment, Stanford University, Stanford, USA
8 shared publications
Latest Publications
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Measuring complex structural emissions with inverse dispersion method and correcting for deposition in the case of ammonia
Measuring trace gas exchanges from structural sources and surfaces with complex topography remains a challenge. The inverse dispersion method provides a suitable option that allows long-term monitoring without interfering with the system. In the case of ammonia emissions such as from animal housings and slurry storage tanks the inverse dispersion method is beneficial compared to other methods which can interfere with daily operations over longer time periods. Ammonia emissions from agriculture can constitute up to 80-90% of reactive N inputs in nearby ecosystems, especially in areas with high livestock densities such as Switzerland. Almost half of these originate from animal housings, which can be difficult to quantify in order to investigate and test mitigation options. However, when measuring emissions from housing and slurry storage facilities, it is necessary to install the instruments at some distance downwind of the structures to avoid turbulence interferences. Since ammonia strongly adsorbs to surfaces immediately following emission, this can lead to a considerable loss before the point of measurement.Deposition models can be used to correct for this loss. Most models consist of a series of resistances to deposition that must be overcome to estimate the total loss. However, the calculation of the bulk canopy resistance requires significant additional site information, which even with its incorporation results in a relatively high uncertainty. Here we present measurements of ammonia emissions from animal housings using the inverse dispersion method which includes a simplified deposition correction. Based on multiple measurement campaigns we show this method to provide a reasonable estimate without the need for additional data while remaining within the same uncertainty range. We further discuss the importance of small-scale deposition from large point sources using controlled release experiments and highlight future development opportunities.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessMeasuring complex structural emissions with inverse dispersion method and correcting for deposition in the case of ammonia
Measuring trace gas exchanges from structural sources and surfaces with complex topography remains a challenge. The inverse dispersion method provides a suitable option that allows long-term monitoring without interfering with the system. In the case of ammonia emissions such as from animal housings and slurry storage tanks the inverse dispersion method is beneficial compared to other methods which can interfere with daily operations over longer time periods. Ammonia emissions from agriculture can constitute up to 80-90% of reactive N inputs in nearby ecosystems, especially in areas with high livestock densities such as Switzerland. Almost half of these originate from animal housings, which can be difficult to quantify in order to investigate and test mitigation options. However, when measuring emissions from housing and slurry storage facilities, it is necessary to install the instruments at some distance downwind of the structures to avoid turbulence interferences. Since ammonia strongly adsorbs to surfaces immediately following emission, this can lead to a considerable loss before the point of measurement.Deposition models can be used to correct for this loss. Most models consist of a series of resistances to deposition that must be overcome to estimate the total loss. However, the calculation of the bulk canopy resistance requires significant additional site information, which even with its incorporation results in a relatively high uncertainty. Here we present measurements of ammonia emissions from animal housings using the inverse dispersion method which includes a simplified deposition correction. Based on multiple measurement campaigns we show this method to provide a reasonable estimate without the need for additional data while remaining within the same uncertainty range. We further discuss the importance of small-scale deposition from large point sources using controlled release experiments and highlight future development opportunities.
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Community outreach using positive sensory experiences: A taste of climate change
Communicating scientific advances and their impacts on society in an accessible manner is an inherent requirement of those engaged with science. Sensitising the public on climate change topics typically relies on rational discourse and the sharing of factual details. However, our first response to novelty, especially in stressful environments is usually emotional and with increasing political polarization, the individual’s priming, environment and beliefs heighten this response to the point of confrontation, avoidance and even denial. One way to potentially mitigate existing negative emotional biases is to approach the topic using a positive emotional experience that is widely shared regardless of identity, such as consuming food and drink.Our project supported by an EGU public engagement grant consisted of small tasting events using locally produced and relevant food and drink items, which could be used as an example of how climate change is or will affect their production and consumption. Events can take on different formats depending on the situation and available resources, as well as allowing a wide range of consumables that can be adapted to the local community and values. Here we provide a brief overview of our activities and outline some implementation aids to support other groups or individuals interested in organizing their own events.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessCommunity outreach using positive sensory experiences: A taste of climate change
Communicating scientific advances and their impacts on society in an accessible manner is an inherent requirement of those engaged with science. Sensitising the public on climate change topics typically relies on rational discourse and the sharing of factual details. However, our first response to novelty, especially in stressful environments is usually emotional and with increasing political polarization, the individual’s priming, environment and beliefs heighten this response to the point of confrontation, avoidance and even denial. One way to potentially mitigate existing negative emotional biases is to approach the topic using a positive emotional experience that is widely shared regardless of identity, such as consuming food and drink.Our project supported by an EGU public engagement grant consisted of small tasting events using locally produced and relevant food and drink items, which could be used as an example of how climate change is or will affect their production and consumption. Events can take on different formats depending on the situation and available resources, as well as allowing a wide range of consumables that can be adapted to the local community and values. Here we provide a brief overview of our activities and outline some implementation aids to support other groups or individuals interested in organizing their own events.
- Open Access
- 25 July 2025
- Published by Elsevier in European Journal of Agronomy
- Vol. 170
Assessing nitrous oxide emissions from grass-clover ley within a crop rotation using measurements and modeling
- 25 July 2025
- Published by Elsevier in European Journal of Agronomy
- Vol. 170
Open AccessAssessing nitrous oxide emissions from grass-clover ley within a crop rotation using measurements and modeling
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Potential limitations of ammonia flux data beyond 72h after field application of slurries
Ammonia volatilization from animal slurry applied to fields is a major source of air pollution in Europe. The ALFAM2 model was developed for estimating ammonia emission from such sources and is used in research, as well as for inventory calculations. Until now, the focus has been on emissions up to 72 hours after application (ALFAM2 model version 1.2), as it was generally assumed that over 90% of total emissions from the applied nitrogen occur during this period. The recently updated ALFAM2 model (version 2.3) now includes emission data up to 168 h after application, which has led the model to indicate substantial emissions between 72 and 168 h leading to a significant increase (
- 20 January 2025
- Published by Copernicus GmbH
Open AccessPotential limitations of ammonia flux data beyond 72h after field application of slurries
Ammonia volatilization from animal slurry applied to fields is a major source of air pollution in Europe. The ALFAM2 model was developed for estimating ammonia emission from such sources and is used in research, as well as for inventory calculations. Until now, the focus has been on emissions up to 72 hours after application (ALFAM2 model version 1.2), as it was generally assumed that over 90% of total emissions from the applied nitrogen occur during this period. The recently updated ALFAM2 model (version 2.3) now includes emission data up to 168 h after application, which has led the model to indicate substantial emissions between 72 and 168 h leading to a significant increase (
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Ammonia emission measurements from agricultural and industrial structures using an inverse dispersion method accounting for deposition loss
Ammonia emissions produce negative environmental and human health impacts with largest emissions originating from agriculture. Especially in countries with high livestock density, the majority originate from animal housing and application to fields. Measuring total emissions from multiple heterogenous source structures such as farms and waste treatment facilities can be challenging due to losses from transport, deposition, and chemical transformation. Previous studies have shown that quantifying net fluxes at this scale can be achieved by combining concentration measurements up- and downwind of the structures with inverse dispersion modelling to calculate the emissions from a defined source area. However, this method underestimates total emissions, as it does not account for deposition loss, which must be modelled and can introduce large uncertainties (
- 20 January 2025
- Published by Copernicus GmbH
Open AccessAmmonia emission measurements from agricultural and industrial structures using an inverse dispersion method accounting for deposition loss
Ammonia emissions produce negative environmental and human health impacts with largest emissions originating from agriculture. Especially in countries with high livestock density, the majority originate from animal housing and application to fields. Measuring total emissions from multiple heterogenous source structures such as farms and waste treatment facilities can be challenging due to losses from transport, deposition, and chemical transformation. Previous studies have shown that quantifying net fluxes at this scale can be achieved by combining concentration measurements up- and downwind of the structures with inverse dispersion modelling to calculate the emissions from a defined source area. However, this method underestimates total emissions, as it does not account for deposition loss, which must be modelled and can introduce large uncertainties (
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Hydrogen sulphide in a fattening pig barn operated with inhouse acidification
With in-house acidification treatments, the pH value of slurry is reduced to a target level of approximately 5.5. It is a promising option for ammonia emission abatement since an emission reduction can be achieved over the entire manure chain which includes housing, manure storage and application. Acidification is done through addition of sulfuric acid (H2SO4) to slurry in a reactor outside of the livestock housing. The acidified slurry is returned to the channels in the house. The excretions of the animals immediately end up in an acidified environment where the equilibrium between NH4+ and NH3,l is shifted towards NH4+. Through the addition of H2SO4, further sulphur is available which can be potentially converted to H2S. This induces concerns for enhanced formation of H2S that is highly toxic to humans and animals. Long-term workplace exposure limits given as 8-h time-weighted averages is 5 ppm with a 15 min exposure threshold of 10 ppm in the EU. The aim of this study is to present data from H2S concentration measurements in a fattening pig housing with 400 animal places in 16 pens littered with straw pellets with a partly slatted floor before and after installation of an in-house acidification method.In 2021, H2S concentrations were measured in the barn using portable gas detectors "PAC 6500 and Multiwarn II" from Dräger and with electrochemical sensors (range of 0.1 - 100 ppm). Four measurement campaigns were conducted. One of them was conducted before the acidification was operative and three campaigns with acidification in summer and winter with and without ventilation of the slurry channels. The number of measurement periods was 5 for the reference measurement and 6 to 14 for the measurement with acidification. The duration of a measurement period was 10 to 104 min, with less than 20 min occurring only in the summer campaign with 14 measurement periods.H2S was exclusively detected when channels were flushed. Outside of periods with flushing, H2S concentrations were below the detection limit of 0.1 ppm. The maximum average over 15 minutes value was 20.2 ppm which was obtained without acidification. With slurry acidification, no exceedance of the 15 Min threshold of 10 ppm occurred, as the maximum H2S concentration was 4.8 ppm. Overall, the mean H2S concentrations with slurry acidification (0.14 ppm) were lower than without acidification (1.44 ppm). The mean values of measured H2S concentrations in winter (0.16 ppm) were higher than in summer (0.06 ppm) due to higher barn ventilation rate in summer. The use of the ventilation system in slurry channels reduced H2S concentrations to 0.16 ppm compared to 0.30 ppm without ventilation. This can be explained by the inhibition of sulfate reduction by microorganisms at a pH of 5.5.Overall, in-house slurry acidification did not enhance H2S concentrations in the investigated pig barn which agrees with previous studies.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessHydrogen sulphide in a fattening pig barn operated with inhouse acidification
With in-house acidification treatments, the pH value of slurry is reduced to a target level of approximately 5.5. It is a promising option for ammonia emission abatement since an emission reduction can be achieved over the entire manure chain which includes housing, manure storage and application. Acidification is done through addition of sulfuric acid (H2SO4) to slurry in a reactor outside of the livestock housing. The acidified slurry is returned to the channels in the house. The excretions of the animals immediately end up in an acidified environment where the equilibrium between NH4+ and NH3,l is shifted towards NH4+. Through the addition of H2SO4, further sulphur is available which can be potentially converted to H2S. This induces concerns for enhanced formation of H2S that is highly toxic to humans and animals. Long-term workplace exposure limits given as 8-h time-weighted averages is 5 ppm with a 15 min exposure threshold of 10 ppm in the EU. The aim of this study is to present data from H2S concentration measurements in a fattening pig housing with 400 animal places in 16 pens littered with straw pellets with a partly slatted floor before and after installation of an in-house acidification method.In 2021, H2S concentrations were measured in the barn using portable gas detectors "PAC 6500 and Multiwarn II" from Dräger and with electrochemical sensors (range of 0.1 - 100 ppm). Four measurement campaigns were conducted. One of them was conducted before the acidification was operative and three campaigns with acidification in summer and winter with and without ventilation of the slurry channels. The number of measurement periods was 5 for the reference measurement and 6 to 14 for the measurement with acidification. The duration of a measurement period was 10 to 104 min, with less than 20 min occurring only in the summer campaign with 14 measurement periods.H2S was exclusively detected when channels were flushed. Outside of periods with flushing, H2S concentrations were below the detection limit of 0.1 ppm. The maximum average over 15 minutes value was 20.2 ppm which was obtained without acidification. With slurry acidification, no exceedance of the 15 Min threshold of 10 ppm occurred, as the maximum H2S concentration was 4.8 ppm. Overall, the mean H2S concentrations with slurry acidification (0.14 ppm) were lower than without acidification (1.44 ppm). The mean values of measured H2S concentrations in winter (0.16 ppm) were higher than in summer (0.06 ppm) due to higher barn ventilation rate in summer. The use of the ventilation system in slurry channels reduced H2S concentrations to 0.16 ppm compared to 0.30 ppm without ventilation. This can be explained by the inhibition of sulfate reduction by microorganisms at a pH of 5.5.Overall, in-house slurry acidification did not enhance H2S concentrations in the investigated pig barn which agrees with previous studies.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Floor heating and heat exchanger as an ammonia mitigation technique for broiler housing
Ammonia (NH3) volatilization from broiler housings is an increasing source of ammonia emissions due to the growing demand of chicken meat. Since modern broiler housings represent mostly larger operations with several thousands of animals, deposition of NH3 in nearby natural or semi-natural ecosystems can be significant and often exceeds critical levels for reactive nitrogen. Therefore, mitigation techniques for NH3 volatilization are crucial. Emissions are strongly influenced by the consistence and the moisture of the litter. Techniques which keep the litter dry such as floor heating and heat exchangers are promising options.We conducted a campaign over an entire production cycle at a farm with parallel emission measurements at two identical broiler housings with 9000 animals each. One building had no mitigation techniques and served as reference, while the other one was operated with floor heating and a heat exchanger (FH-HE). The production cycle in each housing was slightly offset with the Ref cycle lasting from 30th of October until 1st of December 2023 and the FH-HE cycle from 2nd of November until 6th of December 2023. We measured the inflow concentrations of NH3 and CO2 at each of the six air inlet channels and at all of the outlets (3 at the Ref and 4 at the FH-HE housings) using Dräger X-node sensors. The air exchange rate was determined with measuring fans placed at all of the outlets. After the measurement campaign, all sensors were exposed side by side in a nearby cattle barn during 20 days for intercomparison and subsequent correction of the individual sensors.In-house concentrations ranged up to 18 ppm for Ref housing and up to 5 ppm for the FH-HE housing. Highest concentrations and emissions were measured at the end of the production cycle. The emissions over the entire production cycle was 16.9 kg NH3 (Ref) and 1.8 kg for the FH-HE. The emissions were lower by a factor of approximately 9 for the FH-HE house as compared to the Ref. The litter was considerably drier in the FH-HE housing presumably due to the floor heating and the lower ventilation rate which was possible due the heat exchanger, which also led to a lower relative humidity. Additional measurement campaigns covering the winter and the summer seasons will include additional analyses of the moisture content and chemical composition of the litter to further elucidate the emission reduction achieved by the FH-HE. The absolute emission numbers of the present campaign will be evaluated based on an intercomparison with a wet chemical method. The ventilation rate based on a CO2 balance calculation will be compared with the ventilation rate determined from the measuring fans. It will also be analyzed whether a simpler measurement setup based on fewer sensors can be employed to optimize the acquisition of reliable measurement data at reduced costs.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessFloor heating and heat exchanger as an ammonia mitigation technique for broiler housing
Ammonia (NH3) volatilization from broiler housings is an increasing source of ammonia emissions due to the growing demand of chicken meat. Since modern broiler housings represent mostly larger operations with several thousands of animals, deposition of NH3 in nearby natural or semi-natural ecosystems can be significant and often exceeds critical levels for reactive nitrogen. Therefore, mitigation techniques for NH3 volatilization are crucial. Emissions are strongly influenced by the consistence and the moisture of the litter. Techniques which keep the litter dry such as floor heating and heat exchangers are promising options.We conducted a campaign over an entire production cycle at a farm with parallel emission measurements at two identical broiler housings with 9000 animals each. One building had no mitigation techniques and served as reference, while the other one was operated with floor heating and a heat exchanger (FH-HE). The production cycle in each housing was slightly offset with the Ref cycle lasting from 30th of October until 1st of December 2023 and the FH-HE cycle from 2nd of November until 6th of December 2023. We measured the inflow concentrations of NH3 and CO2 at each of the six air inlet channels and at all of the outlets (3 at the Ref and 4 at the FH-HE housings) using Dräger X-node sensors. The air exchange rate was determined with measuring fans placed at all of the outlets. After the measurement campaign, all sensors were exposed side by side in a nearby cattle barn during 20 days for intercomparison and subsequent correction of the individual sensors.In-house concentrations ranged up to 18 ppm for Ref housing and up to 5 ppm for the FH-HE housing. Highest concentrations and emissions were measured at the end of the production cycle. The emissions over the entire production cycle was 16.9 kg NH3 (Ref) and 1.8 kg for the FH-HE. The emissions were lower by a factor of approximately 9 for the FH-HE house as compared to the Ref. The litter was considerably drier in the FH-HE housing presumably due to the floor heating and the lower ventilation rate which was possible due the heat exchanger, which also led to a lower relative humidity. Additional measurement campaigns covering the winter and the summer seasons will include additional analyses of the moisture content and chemical composition of the litter to further elucidate the emission reduction achieved by the FH-HE. The absolute emission numbers of the present campaign will be evaluated based on an intercomparison with a wet chemical method. The ventilation rate based on a CO2 balance calculation will be compared with the ventilation rate determined from the measuring fans. It will also be analyzed whether a simpler measurement setup based on fewer sensors can be employed to optimize the acquisition of reliable measurement data at reduced costs.
- Open Access
- 27 November 2024
- Published by Swiss Chemical Society in Chimia
- Vol. 78 (11) , 771-779
Ammonia Emissions from Swiss Agriculture and their Effects on Atmospheric Chemistry and Ecosystems
Ammonia (NH3) is an important atmospheric pollutant due to its contribution to secondary inorganic aerosol formation and its deposition and impacts on (semi-)natural ecosystems. Therefore various efforts have been made to limit emissions to the atmosphere. The predominant emission source in Switzerland is livestock agriculture, wherein NH3 is volatilised from ammonium contained in animal manure. While modelled NH3 emissions based on agricultural activity data indicate a minor decrease since 2000, concentration measurements do not reflect this trend. This can at least partly be attributed to a decline in the transformation of NH3 to particulate ammonium due to significantly decreased emission of oxidised nitrogen and sulfur compounds in the past decade. The partitioning between the gaseous and the particulate phase also determines the deposition pathway (dry or wet deposition) and thus the average lifetime and transport distance in the atmosphere. Gaseous NH3 is subject to fast dry deposition and is deposited preferentially to ecosystems close to the source. Once deposited into an ecosystem, NH3 leads to eutrophication and acidification of water and soils, which change the plant community composition and microbial functioning, especially in N-sensitive ecosystems. Although NH3 can also cause direct toxicity to plants, assessments of ecosystem impacts are generally collated using the critical load approach, which includes the input of all N compounds. These reveal that in 2020, 87% of forests, 94% of raised bogs, 74% of fens, and 42% of dry mountain grasslands likely experienced adverse impacts from N exceedances in Switzerland. To improve this situation, considerable NH3 emission abatement efforts are needed in the future.
- 27 November 2024
- Published by Swiss Chemical Society in Chimia
- Vol. 78 (11) , 771-779
Open AccessAmmonia Emissions from Swiss Agriculture and their Effects on Atmospheric Chemistry and Ecosystems
Ammonia (NH3) is an important atmospheric pollutant due to its contribution to secondary inorganic aerosol formation and its deposition and impacts on (semi-)natural ecosystems. Therefore various efforts have been made to limit emissions to the atmosphere. The predominant emission source in Switzerland is livestock agriculture, wherein NH3 is volatilised from ammonium contained in animal manure. While modelled NH3 emissions based on agricultural activity data indicate a minor decrease since 2000, concentration measurements do not reflect this trend. This can at least partly be attributed to a decline in the transformation of NH3 to particulate ammonium due to significantly decreased emission of oxidised nitrogen and sulfur compounds in the past decade. The partitioning between the gaseous and the particulate phase also determines the deposition pathway (dry or wet deposition) and thus the average lifetime and transport distance in the atmosphere. Gaseous NH3 is subject to fast dry deposition and is deposited preferentially to ecosystems close to the source. Once deposited into an ecosystem, NH3 leads to eutrophication and acidification of water and soils, which change the plant community composition and microbial functioning, especially in N-sensitive ecosystems. Although NH3 can also cause direct toxicity to plants, assessments of ecosystem impacts are generally collated using the critical load approach, which includes the input of all N compounds. These reveal that in 2020, 87% of forests, 94% of raised bogs, 74% of fens, and 42% of dry mountain grasslands likely experienced adverse impacts from N exceedances in Switzerland. To improve this situation, considerable NH3 emission abatement efforts are needed in the future.
- Open Access
- 16 May 2024
- Published by Elsevier in Agricultural and Forest Meteorology
- Vol. 353
Validation of a short-range dispersion and deposition model using field-scale ammonia and methane release experiments
- 16 May 2024
- Published by Elsevier in Agricultural and Forest Meteorology
- Vol. 353
Open AccessValidation of a short-range dispersion and deposition model using field-scale ammonia and methane release experiments
- Open Access
- 13 November 2023
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 73 (12) , 930-950
Ammonia emissions from a dairy housing and wastewater treatment plant quantified with an inverse dispersion method accounting for deposition loss
Ammonia (NH3) emissions negatively impact air, soil, and water quality, hence human health and biodiversity. Significant emissions, including the largest sources, originate from single or multiple structures, such as livestock facilities and wastewater treatment plants (WWTPs). The inverse dispersion method (IDM) is effective in measuring total emissions from such sources, although depositional loss between the source and point of measurement is often not accounted for. We applied IDM with a deposition correction to determine total emissions from a representative dairy housing and WWTP during several months in autumn and winter in Switzerland. Total emissions were 1.19 ± 0.48 and 2.27 ± 1.53 kg NH3 d-1 for the dairy housing and WWTP, respectively, which compared well with literature values, despite the paucity of WWTPs data. A concurrent comparison with an inhouse tracer ratio method at the dairy housing indicated an offset of the IDM emissions by < 20%. Diurnal emission patterns were evident at both sites mostly driven by changes in air temperature with potential lag effects such as following sludge agitation. Modeled deposition corrections to adjust the concentration loss detected at the measurement point with the associated footprint were 22-28% of the total emissions and the cumulative fraction of deposition to emission modeled with distance from the source was between 7-12% for the measurement distances (60-150 m). Although estimates of depositional loss were plausible, the approach is still connected with substantial uncertainty, which calls for future validation measurements. Longer measurement periods encompassing more management activities and environmental conditions are required to assess predictor variable importance on emission dynamics. Combined, IDM with deposition correction will allow the determination of emission factors at reduced efforts and costs, thereby supporting the development and assessment of emission reducing methods and expand the data availability for emission inventories.
- 13 November 2023
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 73 (12) , 930-950
Open AccessAmmonia emissions from a dairy housing and wastewater treatment plant quantified with an inverse dispersion method accounting for deposition loss
Ammonia (NH3) emissions negatively impact air, soil, and water quality, hence human health and biodiversity. Significant emissions, including the largest sources, originate from single or multiple structures, such as livestock facilities and wastewater treatment plants (WWTPs). The inverse dispersion method (IDM) is effective in measuring total emissions from such sources, although depositional loss between the source and point of measurement is often not accounted for. We applied IDM with a deposition correction to determine total emissions from a representative dairy housing and WWTP during several months in autumn and winter in Switzerland. Total emissions were 1.19 ± 0.48 and 2.27 ± 1.53 kg NH3 d-1 for the dairy housing and WWTP, respectively, which compared well with literature values, despite the paucity of WWTPs data. A concurrent comparison with an inhouse tracer ratio method at the dairy housing indicated an offset of the IDM emissions by < 20%. Diurnal emission patterns were evident at both sites mostly driven by changes in air temperature with potential lag effects such as following sludge agitation. Modeled deposition corrections to adjust the concentration loss detected at the measurement point with the associated footprint were 22-28% of the total emissions and the cumulative fraction of deposition to emission modeled with distance from the source was between 7-12% for the measurement distances (60-150 m). Although estimates of depositional loss were plausible, the approach is still connected with substantial uncertainty, which calls for future validation measurements. Longer measurement periods encompassing more management activities and environmental conditions are required to assess predictor variable importance on emission dynamics. Combined, IDM with deposition correction will allow the determination of emission factors at reduced efforts and costs, thereby supporting the development and assessment of emission reducing methods and expand the data availability for emission inventories.