Jie Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jie Pan has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Xiaojun Qiu
Key Laboratory of Modern Acoustics, Institute of Acoustics, Nanjing University , Nanjing 210093
5 shared publications Hai Huang
Department of Instrument Science and Engineering, Zhejiang University, Hangzhou 310027, China
4 shared publications- Khac Duc Do
School of Civil and Mechanical Engineering, Curtin University , Kent Street, Bentley, WA 6102, Australia
4 shared publications - Shuping Wang
Key Lab. of Modern Acoust. and Inst. of Acoust., Nanjing Univ., No. 22 Hankou Rd., Nanjing, Jiangsu 210093, China
3 shared publications Yanni Zhang
School of Marine Science and Technology, Northwestern Polytechnical University, Xi'an, Shaanxi 710072, China
3 shared publications- K. S. Sum
Dept. of Mech. and Mater. Eng., Univ. of Western Australia, Nedlands, Western Australia 6907
2 shared publications
Latest Publications
- 27 February 2023
- Published by Springer Nature in Nature Computational Science
- Vol. 3 (2) , 120
Effective phase analyzer learned from stock images
- 27 February 2023
- Published by Springer Nature in Nature Computational Science
- Vol. 3 (2) , 120
Effective phase analyzer learned from stock images
- 1 December 2020
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 488, 115634
Novel dynamic model for calculating the equivalent Young's modulus and loss factor of layered beams
- 1 December 2020
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 488, 115634
Novel dynamic model for calculating the equivalent Young's modulus and loss factor of layered beams
- Open Access
- 30 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 178685-178694
Transformer Condition Monitoring Based on Load-Varied Vibration Response and GRU Neural Networks
Study of the vibration mechanisms of transformer windings may lead to useful applications of vibration techniques to transformer online diagnosis. In a power transformer, the clamping force provides a boundary mechanical constraint to ensure the integrity of the winding. Thus, the looseness of the clamping force is an important health indicator for a transformer. Although the effect of clamping force on a winding’s stiffness and natural frequencies is known, the effect of time-varying load current on these natural frequencies remains unsolved. In this paper, this effect is investigated by studying the mechanical frequency response function of an on-load single-phase winding under different clamping forces and variation of the harmonic amplitude of in-service transformers with load current. Then, a gated recurrent unit (GRU) neural network is used to explore the relationship between current sequence and vibration sequence for operating transformers. This study shows that the electromagnetic force induced by the load current affects the vibration response of the winding structure, especially when the looseness of the clamping force is significant. A potential application of the observed phenomenon for online detection of winding conditions is also illustrated.
- 30 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 178685-178694
Open AccessTransformer Condition Monitoring Based on Load-Varied Vibration Response and GRU Neural Networks
Study of the vibration mechanisms of transformer windings may lead to useful applications of vibration techniques to transformer online diagnosis. In a power transformer, the clamping force provides a boundary mechanical constraint to ensure the integrity of the winding. Thus, the looseness of the clamping force is an important health indicator for a transformer. Although the effect of clamping force on a winding’s stiffness and natural frequencies is known, the effect of time-varying load current on these natural frequencies remains unsolved. In this paper, this effect is investigated by studying the mechanical frequency response function of an on-load single-phase winding under different clamping forces and variation of the harmonic amplitude of in-service transformers with load current. Then, a gated recurrent unit (GRU) neural network is used to explore the relationship between current sequence and vibration sequence for operating transformers. This study shows that the electromagnetic force induced by the load current affects the vibration response of the winding structure, especially when the looseness of the clamping force is significant. A potential application of the observed phenomenon for online detection of winding conditions is also illustrated.
- 1 May 2019
- Published by Elsevier in Applied Acoustics
- Vol. 148, 264-275
Vibration of circular rings coupled by elastic elements
- 1 May 2019
- Published by Elsevier in Applied Acoustics
- Vol. 148, 264-275
Vibration of circular rings coupled by elastic elements
- Open Access
- 1 August 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 144 (2) , 598-607
Near-field error sensing for active directivity control of radiated sound
Near-field error sensing is beneficial to the compactness and stability of an active noise control system. This paper proposes an error sensing strategy based on the spatial Fourier transform to achieve active directivity control of radiated sound. The error microphone array is located on a plane close to the primary source and the cost function is the weighted sum of the error signals from the microphones. The weighting factor is related to the phase shift from the error microphones to the plane perpendicular to the direction where noise reduction is required. The geometric configurations of the error microphone array for effective directivity control are investigated. It is found that the distance between neighboring error microphones must be less than approximately half the wavelength of the frequency of interest and the equivalent size of the microphone array should be larger than twice the size of the primary source. Numerical simulations and experiments demonstrate the feasibility of the proposed strategy.
- 1 August 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 144 (2) , 598-607
Open AccessNear-field error sensing for active directivity control of radiated sound
Near-field error sensing is beneficial to the compactness and stability of an active noise control system. This paper proposes an error sensing strategy based on the spatial Fourier transform to achieve active directivity control of radiated sound. The error microphone array is located on a plane close to the primary source and the cost function is the weighted sum of the error signals from the microphones. The weighting factor is related to the phase shift from the error microphones to the plane perpendicular to the direction where noise reduction is required. The geometric configurations of the error microphone array for effective directivity control are investigated. It is found that the distance between neighboring error microphones must be less than approximately half the wavelength of the frequency of interest and the equivalent size of the microphone array should be larger than twice the size of the primary source. Numerical simulations and experiments demonstrate the feasibility of the proposed strategy.
- 6 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (1) , 206-214
Detection of Winding Faults Based on a Characterization of the Nonlinear Dynamics of Transformers
The electrical-mechanical dynamics of a transformer may be described by a model with cascade-connected linear and nonlinear parts. This paper shows that mechanical faults have a significant influence on the linear part of the model. A change in the system order of the linear part of the model can be used as an indicator of variance in a transformer's physical characteristics. A technique based on the Lipschitz criterion is developed to estimate the system order, which is then used for detecting changes in the vibration of the system caused by mechanical faults in the windings. The proposed method is tested on a three-phase power transformer, demonstrating promising detection of faults in transformer windings.
- 6 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (1) , 206-214
Detection of Winding Faults Based on a Characterization of the Nonlinear Dynamics of Transformers
The electrical-mechanical dynamics of a transformer may be described by a model with cascade-connected linear and nonlinear parts. This paper shows that mechanical faults have a significant influence on the linear part of the model. A change in the system order of the linear part of the model can be used as an indicator of variance in a transformer's physical characteristics. A technique based on the Lipschitz criterion is developed to estimate the system order, which is then used for detecting changes in the vibration of the system caused by mechanical faults in the windings. The proposed method is tested on a three-phase power transformer, demonstrating promising detection of faults in transformer windings.
- Open Access
- 1 June 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (6) , 3345-3351
Mechanisms of active control of sound radiation from an opening with boundary installed secondary sources
Previous work has demonstrated that installing secondary sources at the edge of a cavity opening can reduce sound radiation through it, but the mechanisms are not clear, which is investigated in this paper by using the modal decomposition method. It is found that a double layer edge system achieves better performance than a single layer system because secondary sources at the edge of the same layer cannot excite some modes effectively and those at different heights compensate this. There exists an upper limit frequency for the systems with boundary installed secondary sources, which is mainly decided by the length of the short side of the opening. More secondary source layers at the edge will increase the upper limit frequency.
- 1 June 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (6) , 3345-3351
Open AccessMechanisms of active control of sound radiation from an opening with boundary installed secondary sources
Previous work has demonstrated that installing secondary sources at the edge of a cavity opening can reduce sound radiation through it, but the mechanisms are not clear, which is investigated in this paper by using the modal decomposition method. It is found that a double layer edge system achieves better performance than a single layer system because secondary sources at the edge of the same layer cannot excite some modes effectively and those at different heights compensate this. There exists an upper limit frequency for the systems with boundary installed secondary sources, which is mainly decided by the length of the short side of the opening. More secondary source layers at the edge will increase the upper limit frequency.
- 1 December 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 142 (6) , 3722-3735
Enhancing acoustic signal response and absorption of an underwater coated plate by embedding periodical inhomogeneities
An underwater structure is proposed for simultaneous detection and stealth purposes by embedding periodic signal conditioning plates (SCPs) at the interface of two elastic coatings attached to an elastic plate. Results show that the embedded SCPs can enhance sound absorption at frequencies below the coincidence frequency of the plate (fc). Significantly enhanced absorption occurs at five peaks, of which the peak due to excited localized bending resonance in the outer coating between SCPs is the most significant. When the dilatational velocity of the outer coating equals that of the inner coating, nearly total absorption occurs in a wideband, owing to strong coupling between the localized waveguide resonance in the outer coating and that in the inner coating, and the diffraction waves by the SCPs. Meanwhile, an amplified acoustic signal of over 14 dB is observed at most frequencies within 0 ∼ fc at the coatings' interface close to the SCPs' edges, owing to focused stress formed there. Peaks in the signal response at maximal 30 dB are also observed. These peak frequencies are coincident with or close to the peak frequencies of absorption, demonstrating that significantly enhanced acoustic signal and absorption can be achieved simultaneously through the use of embedded periodic SCPs.
- 1 December 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 142 (6) , 3722-3735
Enhancing acoustic signal response and absorption of an underwater coated plate by embedding periodical inhomogeneities
An underwater structure is proposed for simultaneous detection and stealth purposes by embedding periodic signal conditioning plates (SCPs) at the interface of two elastic coatings attached to an elastic plate. Results show that the embedded SCPs can enhance sound absorption at frequencies below the coincidence frequency of the plate (fc). Significantly enhanced absorption occurs at five peaks, of which the peak due to excited localized bending resonance in the outer coating between SCPs is the most significant. When the dilatational velocity of the outer coating equals that of the inner coating, nearly total absorption occurs in a wideband, owing to strong coupling between the localized waveguide resonance in the outer coating and that in the inner coating, and the diffraction waves by the SCPs. Meanwhile, an amplified acoustic signal of over 14 dB is observed at most frequencies within 0 ∼ fc at the coatings' interface close to the SCPs' edges, owing to focused stress formed there. Peaks in the signal response at maximal 30 dB are also observed. These peak frequencies are coincident with or close to the peak frequencies of absorption, demonstrating that significantly enhanced acoustic signal and absorption can be achieved simultaneously through the use of embedded periodic SCPs.
- 1 August 2017
- Published by Elsevier in Applied Acoustics
- Vol. 123, 1-8
Performance of a multichannel active sound radiation control system near a reflecting surface
- 1 August 2017
- Published by Elsevier in Applied Acoustics
- Vol. 123, 1-8
Performance of a multichannel active sound radiation control system near a reflecting surface
- 1 July 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 142 (1) , 91-102
Underwater sound radiation from an elastically coated infinite plate with periodic inhomogeneities of finite width
The underwater sound radiation from a line-force-driven coated infinite plate with periodically attached distributed inhomogeneities is investigated. A typical example of a distributed inhomogeneity is a signal conditioning plate (SCP), which can be inserted between the coating and a hydrophone to increase the strength of the incoming signal. Using the wavenumber transform approach, the surface normal velocity and radiated sound power of the plate are determined by solving the indexed equations of the wavenumber components. This study demonstrates that the elastic coating between the base plate and periodic inhomogeneities may reduce the effect of band-passes and band-gaps on the radiated sound power caused by the inhomogeneities. This is explained in detail by the insulation effect of the coating as a decoupler. The effect of the SCP's width and spatial period on the radiated sound is also examined. Finally, recommendations are given for the application of SCPs for underwater sensing purposes.
- 1 July 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 142 (1) , 91-102
Underwater sound radiation from an elastically coated infinite plate with periodic inhomogeneities of finite width
The underwater sound radiation from a line-force-driven coated infinite plate with periodically attached distributed inhomogeneities is investigated. A typical example of a distributed inhomogeneity is a signal conditioning plate (SCP), which can be inserted between the coating and a hydrophone to increase the strength of the incoming signal. Using the wavenumber transform approach, the surface normal velocity and radiated sound power of the plate are determined by solving the indexed equations of the wavenumber components. This study demonstrates that the elastic coating between the base plate and periodic inhomogeneities may reduce the effect of band-passes and band-gaps on the radiated sound power caused by the inhomogeneities. This is explained in detail by the insulation effect of the coating as a decoupler. The effect of the SCP's width and spatial period on the radiated sound is also examined. Finally, recommendations are given for the application of SCPs for underwater sensing purposes.