Esperanza Garcia-Ruiz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Esperanza Garcia-Ruiz has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Martín Resano
University of Zaragoza
29 shared publications - Frank Vanhaecke
Atomic & Mass Spectrometry-A&MS Research Group, Department of Chemistry, Ghent University, Campus Sterre, Krijgslaan 281-S12, 9000 Ghent, Belgium
14 shared publications - Juan Ramon Castillo
Analytical Spectroscopy and Sensors Group (GEAS), Institute of Environmental Sciences (IUCA), University of Zaragoza, 50009-Zaragoza, Spain
11 shared publications - Juan Carlos Vidal
Group of Analytical Spectroscopy and Sensors (GEAS), Institute of Environmental Sciences (IUCA), University of Zaragoza, Zaragoza, Spain
10 shared publications - Maite Aramendía
Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza, Spain
8 shared publications - Miguel A. Belarra
Department of Analytical Chemistry, University of Zaragoza, Zaragoza, Spain
7 shared publications
Latest Publications
- Open Access
- 23 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (5) , 1951-1963
Single- and dual-isotopic analysis using high-resolution continuum-source graphite-furnace molecular absorption. Strategies for data selection, processing, and modeling
This work presents novel approaches ( e.g. , regression) to processing isotopic data generated by HR CS GFMAS, including a machine learning model that enables obtaining isotopic information from two elements simultaneously.
- 23 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (5) , 1951-1963
Open AccessSingle- and dual-isotopic analysis using high-resolution continuum-source graphite-furnace molecular absorption. Strategies for data selection, processing, and modeling
This work presents novel approaches ( e.g. , regression) to processing isotopic data generated by HR CS GFMAS, including a machine learning model that enables obtaining isotopic information from two elements simultaneously.
- 30 September 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (12) , 2517-2528
High-resolution continuum source graphite furnace molecular absorption spectrometry for the monitoring of Sr isotopes via SrF formation: a case study
A new approach for monitoring Sr isotopes via HR CS GFMAS is described.
- 30 September 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (12) , 2517-2528
High-resolution continuum source graphite furnace molecular absorption spectrometry for the monitoring of Sr isotopes via SrF formation: a case study
A new approach for monitoring Sr isotopes via HR CS GFMAS is described.
- Top Cited PapersOpen Access
- 14 March 2022
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 13 (16) , 4436-4473
Living in a transient world: ICP-MS reinvented via time-resolved analysis for monitoring single events
After 40 years of development, inductively coupled plasma-mass spectrometry (ICP-MS) can hardly be considered as a novel technique anymore. ICP-MS has become the reference when it comes to multi-element bulk analysis at (ultra)trace levels, as well as to isotope ratio determination for metal(loid)s. However, over the last decade, this technique has managed to uncover an entirely new application field, providing information in a variety of contexts related to the individual analysis of single entities (e.g., nanoparticles, cells, or micro/nanoplastics), thus addressing new societal challenges. And this profound expansion of its application range becomes even more remarkable when considering that it has been made possible in an a priori simple way: by providing faster data acquisition and developing the corresponding theoretical substrate to relate the time-resolved signals thus obtained with the elemental composition of the target entities. This review presents the underlying concepts behind single event-ICP-MS, which are needed to fully understand its potential, highlighting key areas of application (e.g., single particle-ICP-MS or single cell-ICP-MS) as well as of future development (e.g., micro/nanoplastics).
- 14 March 2022
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 13 (16) , 4436-4473
Top Cited PapersOpen AccessLiving in a transient world: ICP-MS reinvented via time-resolved analysis for monitoring single events
After 40 years of development, inductively coupled plasma-mass spectrometry (ICP-MS) can hardly be considered as a novel technique anymore. ICP-MS has become the reference when it comes to multi-element bulk analysis at (ultra)trace levels, as well as to isotope ratio determination for metal(loid)s. However, over the last decade, this technique has managed to uncover an entirely new application field, providing information in a variety of contexts related to the individual analysis of single entities (e.g., nanoparticles, cells, or micro/nanoplastics), thus addressing new societal challenges. And this profound expansion of its application range becomes even more remarkable when considering that it has been made possible in an a priori simple way: by providing faster data acquisition and developing the corresponding theoretical substrate to relate the time-resolved signals thus obtained with the elemental composition of the target entities. This review presents the underlying concepts behind single event-ICP-MS, which are needed to fully understand its potential, highlighting key areas of application (e.g., single particle-ICP-MS or single cell-ICP-MS) as well as of future development (e.g., micro/nanoplastics).
- 10 September 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (11) , 2606-2619
Introducing multi-energy ratios as an alternative to multi-energy calibration for Br determination via high-resolution continuum source graphite furnace molecular absorption spectrometry. A case study
This manuscript explores the advantages of using multi-signal calibration approaches for the determination of non-metals via high-resolution continuum source graphite furnace molecular absorption spectrometry (HR CS GFMAS), targeting Br as an example. Besides multi-energy calibration (MEC), a novel approach deriving from it, multi-energy ratios (MER), is introduced and compared under different conditions. This approach makes use of the same data but in a different way, such that no linear regression is performed; instead, ratios are calculated. This article investigates the potential errors deriving from the use of amounts of spike dissimilar from the sample content, leading to too high (close to 1) or too low (close to 0) slopes/ratios, setting the best conditions in terms of precision and accuracy for the intended determination in the range of approx. 0.5 to 0.6. Also, situations where the use of MER could be recommended over MEC are identified: namely when only a few transitions of sufficient sensitivity and free from overlaps are available or else, many transitions but of similar sensitivity, which may occur when HR CS GFMAS is deployed. Otherwise, for multiple transitions covering a wider sensitivity range, use of linear regression and thus, of MEC, seems favoured, as a better precision can be achieved. The calculation of limits of detection and quantification for both approaches is also discussed. It is finally further demonstrated that these multi-signal strategies help in solving chemical interferences, which very often hamper the determination of non-metals with HR CS GFMAS, and they do so in a simple way, without the need for laborious work or for the preparation of several standards and sample aliquots, therefore making them a very intriguing option when this technique is deployed.
- 10 September 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (11) , 2606-2619
Introducing multi-energy ratios as an alternative to multi-energy calibration for Br determination via high-resolution continuum source graphite furnace molecular absorption spectrometry. A case study
This manuscript explores the advantages of using multi-signal calibration approaches for the determination of non-metals via high-resolution continuum source graphite furnace molecular absorption spectrometry (HR CS GFMAS), targeting Br as an example. Besides multi-energy calibration (MEC), a novel approach deriving from it, multi-energy ratios (MER), is introduced and compared under different conditions. This approach makes use of the same data but in a different way, such that no linear regression is performed; instead, ratios are calculated. This article investigates the potential errors deriving from the use of amounts of spike dissimilar from the sample content, leading to too high (close to 1) or too low (close to 0) slopes/ratios, setting the best conditions in terms of precision and accuracy for the intended determination in the range of approx. 0.5 to 0.6. Also, situations where the use of MER could be recommended over MEC are identified: namely when only a few transitions of sufficient sensitivity and free from overlaps are available or else, many transitions but of similar sensitivity, which may occur when HR CS GFMAS is deployed. Otherwise, for multiple transitions covering a wider sensitivity range, use of linear regression and thus, of MEC, seems favoured, as a better precision can be achieved. The calculation of limits of detection and quantification for both approaches is also discussed. It is finally further demonstrated that these multi-signal strategies help in solving chemical interferences, which very often hamper the determination of non-metals with HR CS GFMAS, and they do so in a simple way, without the need for laborious work or for the preparation of several standards and sample aliquots, therefore making them a very intriguing option when this technique is deployed.
- 19 September 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (1) , 59-80
Quo vadis high-resolution continuum source atomic/molecular absorption spectrometry?
After more than a decade since its commercial introduction, high-resolution continuum source atomic/molecular absorption spectrometry may be facing a mid-life crisis. Certainly, it is no longer a novel technique full of unknown potential, so it would already be time to establish the fields for which it is most suitable. This is, however, not so simple for a number of reasons. In the first place, more than a technique what we are discussing herein is a type of instrumentation with the potential to use two different techniques (atomic or molecular absorption), making it somewhat unique. Furthermore, the two techniques have not been explored equally, and more research on the mechanisms of formation of diatomic molecules is clearly needed. In the second place, new possibilities have recently appeared in the literature that need to be weighed as well. And there is the still unfulfilled, but nowadays more technically feasible than ever, promise to significantly increase the multi-elemental capabilities. This review critically examines the main research areas currently explored (namely, (i) direct analysis of solids and complex liquid materials, and (ii) determination of non-metals at trace levels via monitoring of molecular species) as well as the new venues (specifically, (i) isotopic analysis via monitoring of molecular species, and (ii) selective detection, quantification and sizing of nanoparticles) while also considering new instrumental developments, in an attempt to properly place high-resolution continuum source atomic/molecular absorption spectrometry in the field of trace element and isotopic analysis.
- 19 September 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (1) , 59-80
Quo vadis high-resolution continuum source atomic/molecular absorption spectrometry?
After more than a decade since its commercial introduction, high-resolution continuum source atomic/molecular absorption spectrometry may be facing a mid-life crisis. Certainly, it is no longer a novel technique full of unknown potential, so it would already be time to establish the fields for which it is most suitable. This is, however, not so simple for a number of reasons. In the first place, more than a technique what we are discussing herein is a type of instrumentation with the potential to use two different techniques (atomic or molecular absorption), making it somewhat unique. Furthermore, the two techniques have not been explored equally, and more research on the mechanisms of formation of diatomic molecules is clearly needed. In the second place, new possibilities have recently appeared in the literature that need to be weighed as well. And there is the still unfulfilled, but nowadays more technically feasible than ever, promise to significantly increase the multi-elemental capabilities. This review critically examines the main research areas currently explored (namely, (i) direct analysis of solids and complex liquid materials, and (ii) determination of non-metals at trace levels via monitoring of molecular species) as well as the new venues (specifically, (i) isotopic analysis via monitoring of molecular species, and (ii) selective detection, quantification and sizing of nanoparticles) while also considering new instrumental developments, in an attempt to properly place high-resolution continuum source atomic/molecular absorption spectrometry in the field of trace element and isotopic analysis.
- 20 July 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (10) , 1916-1924
Cerebrospinal fluid elemental analysis by using a total sample consumption system operated at high temperature adapted to inductively coupled plasma mass spectrometry
A total consumption low sample introduction system has been applied for the first time to the multielement analysis of non-diluted cerebrospinal fluids (CSFs) by means of inductively coupled plasma mass spectrometry (ICP-MS). A 2.5 μL sample volume has been injected into an air carrier stream in agreement with the air-segmented injection principle. The sample plug has been turned into an aerosol by means of a high efficiency nebulizer (HEN) and further introduced into the so-called high temperature torch integrated sample introduction system (hTISIS). A transient signal has been thus obtained. For spiked CSF real samples it has been verified that the higher the temperature, the greater the sensitivity. Under optimized conditions, the hTISIS provides peak areas around four times higher than those provided by the spectrometer default device (i.e., a double pass spray chamber). Additional advantages provided by the former system include limits of detection up to 6 times lower and narrower peaks as compared to those reported for the double pass spray chamber. Furthermore, the use of the hTISIS is not detrimental from the point of view oxide production and doubly charged ion generation. Regarding the extent of non-spectral interference caused by the CSF matrix, it has been verified that, with the hTISIS, recoveries for spiked real samples were close to 100% for a set of 14 different elements (V, Cr, Mn, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Ba, Tl and Pb). Meanwhile, in segmented flow injection mode, the reference system provided recoveries from 200 to 500%, depending on the element and the sample, thus demonstrating the occurrence of matrix effects.
- 20 July 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (10) , 1916-1924
Cerebrospinal fluid elemental analysis by using a total sample consumption system operated at high temperature adapted to inductively coupled plasma mass spectrometry
A total consumption low sample introduction system has been applied for the first time to the multielement analysis of non-diluted cerebrospinal fluids (CSFs) by means of inductively coupled plasma mass spectrometry (ICP-MS). A 2.5 μL sample volume has been injected into an air carrier stream in agreement with the air-segmented injection principle. The sample plug has been turned into an aerosol by means of a high efficiency nebulizer (HEN) and further introduced into the so-called high temperature torch integrated sample introduction system (hTISIS). A transient signal has been thus obtained. For spiked CSF real samples it has been verified that the higher the temperature, the greater the sensitivity. Under optimized conditions, the hTISIS provides peak areas around four times higher than those provided by the spectrometer default device (i.e., a double pass spray chamber). Additional advantages provided by the former system include limits of detection up to 6 times lower and narrower peaks as compared to those reported for the double pass spray chamber. Furthermore, the use of the hTISIS is not detrimental from the point of view oxide production and doubly charged ion generation. Regarding the extent of non-spectral interference caused by the CSF matrix, it has been verified that, with the hTISIS, recoveries for spiked real samples were close to 100% for a set of 14 different elements (V, Cr, Mn, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Ba, Tl and Pb). Meanwhile, in segmented flow injection mode, the reference system provided recoveries from 200 to 500%, depending on the element and the sample, thus demonstrating the occurrence of matrix effects.
- 7 December 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (9-10) , 2239-2259
Progress in the determination of metalloids and non-metals by means of high-resolution continuum source atomic or molecular absorption spectrometry. A critical review
This work examines the new possibilities introduced with the arrival of commercially available high-resolution continuum source atomic absorption spectrometers for the determination of metalloids (B, Si, Ge, As, Se, Sb and Te) and non-metals (P, S, F, Cl, Br, I and N-based species), such as the improved potential to detect and correct for spectral overlaps and the strategies available to correct for matrix effects. In particular, and considering the increasing number of papers reporting on the use of molecular absorption spectrometry using graphite furnaces and flames as vaporizers, the work discusses in detail the advantages and limitations derived from the monitoring of molecular spectra from a practical point of view, in an attempt to guide future users of the technique. Figure
- 7 December 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (9-10) , 2239-2259
Progress in the determination of metalloids and non-metals by means of high-resolution continuum source atomic or molecular absorption spectrometry. A critical review
This work examines the new possibilities introduced with the arrival of commercially available high-resolution continuum source atomic absorption spectrometers for the determination of metalloids (B, Si, Ge, As, Se, Sb and Te) and non-metals (P, S, F, Cl, Br, I and N-based species), such as the improved potential to detect and correct for spectral overlaps and the strategies available to correct for matrix effects. In particular, and considering the increasing number of papers reporting on the use of molecular absorption spectrometry using graphite furnaces and flames as vaporizers, the work discusses in detail the advantages and limitations derived from the monitoring of molecular spectra from a practical point of view, in an attempt to guide future users of the technique. Figure
- 1 May 2012
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 71-72, 24-30
Direct analysis of silica by means of solid sampling graphite furnace atomic absorption spectrometry
- 1 May 2012
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 71-72, 24-30
Direct analysis of silica by means of solid sampling graphite furnace atomic absorption spectrometry
- 18 April 2012
- Published by Wiley
- p. 859-883
Laser Ablation–Inductively Coupled Plasma Mass Spectrometry for the Investigation of Archaeological Samples
- 18 April 2012
- Published by Wiley
- p. 859-883
Laser Ablation–Inductively Coupled Plasma Mass Spectrometry for the Investigation of Archaeological Samples