Richard Hall-Wilton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Richard Hall-Wilton has a total of 157 co-authors. Here are the top co-authors by number of shared publications:
- Kalliopi Kanaki
Department of Nuclear Sciences and Applications, IAEA, Nuclear Science and Instrumentation Laboratory, Physics Section, Division of Physical and Chemical Sciences, Vienna International Center, Vienna, Austria
5 shared publications - Kevin G. Fissum
Division of Nuclear Physics, Lund University, SE-221 00, Lund, Sweden
3 shared publications A. Quintanilla
European Spallation Source ESS ERIC P.O Box 176 SE-221 00 Lund Sweden
2 shared publications- Alexander Backis
School of Physics & Astronomy, University of Glasgow, Glasgow, UK
2 shared publications - Emil Rofors
Lawrence Berkeley National Laboratory, Berkeley, CA, USA
2 shared publications - Eraldo Oliveri
European Organization for Nuclear Research (CERN), 1211 Geneva 23, Switzerland
2 shared publications
Latest Publications
- Open Access
- 1 April 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (04) , C04017
Plasma-based etching approach for GEM detector microfabrication at FBK for X-ray polarimetry in space
Gas Electron Multiplier (GEM) detectors are crucial for enabling high-resolution X-ray polarization of astrophysical sources when coupled to custom pixel readout ASIC in Gas Pixel Detectors (GPD), as in the Imaging X-ray Polarimetry Explorer (IXPE), the Polarlight cubesat pathfinder and the PFA telescope onboard the future large enhanced X-ray Timing and Polarimetry (eXTP) Chinese mission. The R&D efforts of the IXPE collaboration have resulted in mature GPD technology. However, limitations in the classical wet-etch or laser-drilled fabrication process of GEMs motivated our exploration of alternative methods. This work focuses on investigating a plasma-based etching approach for fabricating GEM patterns at Fondazione Bruno Kessler (FBK). The objective is to improve the aspect ratio of the GEM holes, to mitigate the charging of the GEM dielectric which generates rate-dependent gain changes. Unlike the traditional wet-etch process, Reactive Ion Etching (RIE) enables more vertical etching profiles and thus better aspect ratios. Moreover, the RIE process promises to overcome non-uniformities in the GEM hole patterns which are believed to cause systemic effects in the azimuthal response of GPDs equipped with either laser-drilled or wet-etch GEMs. We present a GEM geometry with 20 μm in diameter and 50 μm pitch, accompanied by extensive characterization (SEM and PFIB) of the structural features and aspect ratios. The collaboration with INFN Pisa and Turin enabled us to compare the electrical properties of these detectors and test their performance in their use as electron multipliers in GPDs. Although this R&D work is in its initial stages, it holds promise for enhancing the sensitivity of the IXPE mission in X-ray polarimetry measurements through GEM pattern with more vertical hole profiles. The outcomes of this study have the potential to advance the current technological platforms and improve the capabilities of future space-based X-ray polarimetry missions.
- 1 April 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (04) , C04017
Open AccessPlasma-based etching approach for GEM detector microfabrication at FBK for X-ray polarimetry in space
Gas Electron Multiplier (GEM) detectors are crucial for enabling high-resolution X-ray polarization of astrophysical sources when coupled to custom pixel readout ASIC in Gas Pixel Detectors (GPD), as in the Imaging X-ray Polarimetry Explorer (IXPE), the Polarlight cubesat pathfinder and the PFA telescope onboard the future large enhanced X-ray Timing and Polarimetry (eXTP) Chinese mission. The R&D efforts of the IXPE collaboration have resulted in mature GPD technology. However, limitations in the classical wet-etch or laser-drilled fabrication process of GEMs motivated our exploration of alternative methods. This work focuses on investigating a plasma-based etching approach for fabricating GEM patterns at Fondazione Bruno Kessler (FBK). The objective is to improve the aspect ratio of the GEM holes, to mitigate the charging of the GEM dielectric which generates rate-dependent gain changes. Unlike the traditional wet-etch process, Reactive Ion Etching (RIE) enables more vertical etching profiles and thus better aspect ratios. Moreover, the RIE process promises to overcome non-uniformities in the GEM hole patterns which are believed to cause systemic effects in the azimuthal response of GPDs equipped with either laser-drilled or wet-etch GEMs. We present a GEM geometry with 20 μm in diameter and 50 μm pitch, accompanied by extensive characterization (SEM and PFIB) of the structural features and aspect ratios. The collaboration with INFN Pisa and Turin enabled us to compare the electrical properties of these detectors and test their performance in their use as electron multipliers in GPDs. Although this R&D work is in its initial stages, it holds promise for enhancing the sensitivity of the IXPE mission in X-ray polarimetry measurements through GEM pattern with more vertical hole profiles. The outcomes of this study have the potential to advance the current technological platforms and improve the capabilities of future space-based X-ray polarimetry missions.
- Open Access
- 23 February 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1062
Light-yield response of liquid scintillators using 2–6 MeV tagged neutrons
- 23 February 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1062
Open AccessLight-yield response of liquid scintillators using 2–6 MeV tagged neutrons
- Open Access
Demonstration of Gd-GEM detector design for neutron macromolecular crystallography applications
The European Spallation Source (ESS) in Lund, Sweden will become the world's most powerful thermal neutron source. The Macromolecular Diffractometer (NMX) at the ESS requires three 51.2 x 51.2~cm$^{2}$ detectors with reasonable detection efficiency, sub-mm spatial resolution, a narrow point spread function (PSF) and good time resolution. This work presents measurements with the improved version of the NMX detector prototype consisting of a Triple-GEM detector with natural Gd converter and a low material budget readout. The detector was successfully tested at the neutron reactor of the Budapest Neutron Centre (BNC) and at the D16 instrument at the Institut Laue-Langevin (ILL) in Grenoble. The measurements with Cadmium and Gadolinium masks in Budapest demonstrate that the point spread function of the detector lacks long tails that could impede the measurement of diffraction spot intensities. On the D16 instrument at ILL, diffraction spots from Triose phosphate isomerase w/ 2-phosphoglycolate (PGA) inhibitor were measured both in the D16 Helium-3 detector and the Gd-GEM. The comparison between the two detectors show a similar point spread function in both detectors, and the expected efficiency ratio compared to the Helium-3 detector. Both measurements together thus give good indications that the Gd-GEM detector fits the requirements for the NMX instrument at ESS.
Open AccessDemonstration of Gd-GEM detector design for neutron macromolecular crystallography applications
The European Spallation Source (ESS) in Lund, Sweden will become the world's most powerful thermal neutron source. The Macromolecular Diffractometer (NMX) at the ESS requires three 51.2 x 51.2~cm$^{2}$ detectors with reasonable detection efficiency, sub-mm spatial resolution, a narrow point spread function (PSF) and good time resolution. This work presents measurements with the improved version of the NMX detector prototype consisting of a Triple-GEM detector with natural Gd converter and a low material budget readout. The detector was successfully tested at the neutron reactor of the Budapest Neutron Centre (BNC) and at the D16 instrument at the Institut Laue-Langevin (ILL) in Grenoble. The measurements with Cadmium and Gadolinium masks in Budapest demonstrate that the point spread function of the detector lacks long tails that could impede the measurement of diffraction spot intensities. On the D16 instrument at ILL, diffraction spots from Triose phosphate isomerase w/ 2-phosphoglycolate (PGA) inhibitor were measured both in the D16 Helium-3 detector and the Gd-GEM. The comparison between the two detectors show a similar point spread function in both detectors, and the expected efficiency ratio compared to the Helium-3 detector. Both measurements together thus give good indications that the Gd-GEM detector fits the requirements for the NMX instrument at ESS.
- Open Access
- 25 October 2022
- Published by Springer Nature in EPJ Techniques and Instrumentation
- Vol. 9 (1) , 1-15
First evaluation of a novel ionisation chamber for thermal neutron beam monitoring
The European Spallation Source ERIC (ESS), currently under construction in Lund, Sweden is a facility established to deliver the highest integrated neutron flux originating from a pulsed source with the aim of supporting an initial fifteen neutron instruments for cutting edge science experiments. This in turn requires reliable monitoring at complex neutron beam lines: in particular, linearity, timing capability, adaptability of the design for various flux ranges (dynamic range) and sensitivity to neutrons within the range of 0.6-10Å are expected from the neutron beam monitors to be installed at the ESS beam lines. Additionally, operational stability and low attenuation are also desirable characteristics for such neutron beam monitoring. A prototype neutron beam monitor based on the ionisation chamber principle and a boron converter, designed by CDT CASCADE Detector Technologies GmbH and ESS, has been investigated at the BER-II research reactor of Helmholtz Zentrum Berlin (HZB). The effort to design and investigate a thermal neutron ionisation beam monitor was initiated by adapting the concept of ionisation chambers previously known elsewhere. So far all the characterised neutron beam monitors discriminate neutron hits on a discrete event basis (pulse mode), whereas the beam monitor prototype introduced in this paper estimates the total flux as a function of current (current mode). While most other neutron beam monitoring devices and detectors rely upon a signal amplifying gain stage, the ionisation chamber operates without any gain and is consequently robust against typical detector ageing effects that compromise the sensitivity over time. The initial tests were performed at the ESS V20 test beam line under realistic conditions resembling those of the future pulses of ESS. The linearity is demonstrated for 3Å pulses in the flux range of 2-3 × 105 n/s/cm2 and for white pulses (0.6-10Å) in the range of 1-5 × 106 n/s/cm2. The timing behaviour resembles the data previously recorded at the V20 beam lines. This novel implementation of a neutron sensitive ionisation chamber shows great promise for beam monitoring and diagnostics at ESS. As the ionisation beam monitor itself is an entirely passive device, it is adequately robust to be employed in areas of high irradiation where no regular servicing or maintenance can be provided.
- 25 October 2022
- Published by Springer Nature in EPJ Techniques and Instrumentation
- Vol. 9 (1) , 1-15
Open AccessFirst evaluation of a novel ionisation chamber for thermal neutron beam monitoring
The European Spallation Source ERIC (ESS), currently under construction in Lund, Sweden is a facility established to deliver the highest integrated neutron flux originating from a pulsed source with the aim of supporting an initial fifteen neutron instruments for cutting edge science experiments. This in turn requires reliable monitoring at complex neutron beam lines: in particular, linearity, timing capability, adaptability of the design for various flux ranges (dynamic range) and sensitivity to neutrons within the range of 0.6-10Å are expected from the neutron beam monitors to be installed at the ESS beam lines. Additionally, operational stability and low attenuation are also desirable characteristics for such neutron beam monitoring. A prototype neutron beam monitor based on the ionisation chamber principle and a boron converter, designed by CDT CASCADE Detector Technologies GmbH and ESS, has been investigated at the BER-II research reactor of Helmholtz Zentrum Berlin (HZB). The effort to design and investigate a thermal neutron ionisation beam monitor was initiated by adapting the concept of ionisation chambers previously known elsewhere. So far all the characterised neutron beam monitors discriminate neutron hits on a discrete event basis (pulse mode), whereas the beam monitor prototype introduced in this paper estimates the total flux as a function of current (current mode). While most other neutron beam monitoring devices and detectors rely upon a signal amplifying gain stage, the ionisation chamber operates without any gain and is consequently robust against typical detector ageing effects that compromise the sensitivity over time. The initial tests were performed at the ESS V20 test beam line under realistic conditions resembling those of the future pulses of ESS. The linearity is demonstrated for 3Å pulses in the flux range of 2-3 × 105 n/s/cm2 and for white pulses (0.6-10Å) in the range of 1-5 × 106 n/s/cm2. The timing behaviour resembles the data previously recorded at the V20 beam lines. This novel implementation of a neutron sensitive ionisation chamber shows great promise for beam monitoring and diagnostics at ESS. As the ionisation beam monitor itself is an entirely passive device, it is adequately robust to be employed in areas of high irradiation where no regular servicing or maintenance can be provided.
- Open Access
- 15 July 2022
- Published by Springer Nature in EPJ Techniques and Instrumentation
- Vol. 9 (1) , 1-48
General considerations for effective thermal neutron shielding in detector applications
For thermal neutron detectors, effective shielding is a crucial aspect of signal-to-background optimization. This is especially important for cold to thermal neutrons, as the detectors are most sensitive in this energy range. In this work, a few common shielding materials, such as cadmium, B4C and epoxy-Gd2O3 mixtures, are analytically evaluated based on interaction cross sections extracted from Geant4. For these materials, the neutron absorption and scattering dependence on material thickness and incident neutron energy are examined. It is also considered how the absorption and scattering change with different material compositions, such as 10B-content in B4C, and component ratio in epoxy-Gd2O3 mixtures. In addition, a framework is introduced to quantify the effectiveness of the neutron shielding, comparing the relationship between absorption and scattering of different shielding materials. The aim is to provide a general tool kit, which can be used to quickly identify an appropriate shielding material, with the required thickness, to reach a desired thermal neutron shielding performance. Finally, as an example, the developed tool kit is applied to the specific shielding application for the Multi-Grid CSPEC detector, currently in development for the European Spallation Source.
- 15 July 2022
- Published by Springer Nature in EPJ Techniques and Instrumentation
- Vol. 9 (1) , 1-48
Open AccessGeneral considerations for effective thermal neutron shielding in detector applications
For thermal neutron detectors, effective shielding is a crucial aspect of signal-to-background optimization. This is especially important for cold to thermal neutrons, as the detectors are most sensitive in this energy range. In this work, a few common shielding materials, such as cadmium, B4C and epoxy-Gd2O3 mixtures, are analytically evaluated based on interaction cross sections extracted from Geant4. For these materials, the neutron absorption and scattering dependence on material thickness and incident neutron energy are examined. It is also considered how the absorption and scattering change with different material compositions, such as 10B-content in B4C, and component ratio in epoxy-Gd2O3 mixtures. In addition, a framework is introduced to quantify the effectiveness of the neutron shielding, comparing the relationship between absorption and scattering of different shielding materials. The aim is to provide a general tool kit, which can be used to quickly identify an appropriate shielding material, with the required thickness, to reach a desired thermal neutron shielding performance. Finally, as an example, the developed tool kit is applied to the specific shielding application for the Multi-Grid CSPEC detector, currently in development for the European Spallation Source.
- Open Access
- 17 March 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1031
Rate-capability of the VMM3a front-end in the RD51 Scalable Readout System
- 17 March 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1031
Open AccessRate-capability of the VMM3a front-end in the RD51 Scalable Readout System
- Open Access
Parasitic neutron beam monitoring: proof of concept on gamma monitoring of neutron chopper phases
Neutron beam monitors are an essential diagnostic component of neutron scattering facilities. They are used to measure neutron flux, calibrating experiments performed on the instruments, allowing measurement of facility performance, understanding of the effect on the neutrons of beam-line components (such as choppers), calibration of detectors and tracking of beam stability. Ideally beam monitors {should} not perturb the beam. Previous work shows commercial beam monitors attenuate the beam by a few percent in the worst case due to the 1-2 mm thick Aluminium entrance and exit windows and the material inside. Parasitic methods of neutron beam diagnostics, where there is no beam monitor directly in the beam, would be preferable. This paper presents the concept of a parasitic method of monitoring the beam which can be used for neutron chopper phasing. This is achieved by placing a gamma detector close to a rotating chopper and measures a signal proportional to the flux absorbed by the chopper. Neutrons interact with the Boron absorber on the chopper disc lead to gamma emission at 480 keV. Detection of these gamma rays is used to determine the chopper phasing and timing. Potentially information on the flux of the beamline can be extracted. Results from a proof of concept implementation show that diagnosis of neutron chopper phases is feasible.
Open AccessParasitic neutron beam monitoring: proof of concept on gamma monitoring of neutron chopper phases
Neutron beam monitors are an essential diagnostic component of neutron scattering facilities. They are used to measure neutron flux, calibrating experiments performed on the instruments, allowing measurement of facility performance, understanding of the effect on the neutrons of beam-line components (such as choppers), calibration of detectors and tracking of beam stability. Ideally beam monitors {should} not perturb the beam. Previous work shows commercial beam monitors attenuate the beam by a few percent in the worst case due to the 1-2 mm thick Aluminium entrance and exit windows and the material inside. Parasitic methods of neutron beam diagnostics, where there is no beam monitor directly in the beam, would be preferable. This paper presents the concept of a parasitic method of monitoring the beam which can be used for neutron chopper phasing. This is achieved by placing a gamma detector close to a rotating chopper and measures a signal proportional to the flux absorbed by the chopper. Neutrons interact with the Boron absorber on the chopper disc lead to gamma emission at 480 keV. Detection of these gamma rays is used to determine the chopper phasing and timing. Potentially information on the flux of the beamline can be extracted. Results from a proof of concept implementation show that diagnosis of neutron chopper phases is feasible.
- Open Access
- 1 October 2020
- Published by Oxford University Press (OUP) in Europhysics Letters
- Vol. 132 (2) , 22001
Parasitic neutron beam monitoring: Proof of concept on gamma monitoring of neutron chopper phases
Neutron beam monitors are an essential diagnostic component of neutron scattering facilities. They are used to measure neutron flux, calibrating experiments performed on the instruments, allowing measurement of facility performance, understanding of the effect on the neutrons of beam-line components (such as choppers), calibration of detectors and tracking of beam stability. Ideally beam monitors should not perturb the beam. Previous work shows commercial beam monitors attenuate the beam by a few percent in the worst case due to the 1–2 mm thick aluminium entrance and exit windows and the material inside. Parasitic methods of neutron beam diagnostics, where there is no beam monitor directly in the beam, would be preferable. This paper presents the concept of a parasitic method of monitoring the beam which can be used for neutron chopper phasing. This is achieved by placing a gamma detector close to a rotating chopper and measuring a signal proportional to the flux absorbed by the chopper. Neutrons interact with the boron absorber on the chopper disc leading to gamma emission at 480 keV. Detection of these gamma rays is used to determine the chopper phasing and timing. Potentially information on the flux of the beamline can be extracted. Results from a proof of concept implementation show that diagnosis of neutron chopper phases is feasible.
- 1 October 2020
- Published by Oxford University Press (OUP) in Europhysics Letters
- Vol. 132 (2) , 22001
Open AccessParasitic neutron beam monitoring: Proof of concept on gamma monitoring of neutron chopper phases
Neutron beam monitors are an essential diagnostic component of neutron scattering facilities. They are used to measure neutron flux, calibrating experiments performed on the instruments, allowing measurement of facility performance, understanding of the effect on the neutrons of beam-line components (such as choppers), calibration of detectors and tracking of beam stability. Ideally beam monitors should not perturb the beam. Previous work shows commercial beam monitors attenuate the beam by a few percent in the worst case due to the 1–2 mm thick aluminium entrance and exit windows and the material inside. Parasitic methods of neutron beam diagnostics, where there is no beam monitor directly in the beam, would be preferable. This paper presents the concept of a parasitic method of monitoring the beam which can be used for neutron chopper phasing. This is achieved by placing a gamma detector close to a rotating chopper and measuring a signal proportional to the flux absorbed by the chopper. Neutrons interact with the boron absorber on the chopper disc leading to gamma emission at 480 keV. Detection of these gamma rays is used to determine the chopper phasing and timing. Potentially information on the flux of the beamline can be extracted. Results from a proof of concept implementation show that diagnosis of neutron chopper phases is feasible.