Congqi Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Congqi Fang has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Shuai Yang
CCCC Fourth Harbor Engineering Institute Co. Ltd., Guangzhou, P. R. China
2 shared publications- Zhijie Yuan
School of Naval Architecture, Ocean and Civil Engineering, Shanghai Jiao Tong University, 200240 Shanghai, China
2 shared publications - Chandan Shakya
University of Amsterdam
1 shared publication Chaoying Zhu
Department of Civil Engineering, Shanghai Jiaotong University, Shanghai 200240, PR China
1 shared publicationHang Yang
School of Civil Engineering, Shanghai Normal University, 201418 Shanghai, China
1 shared publicationJunmeng Zhang
Shanghai Fuli Real Estate Development Co., Ltd., Shanghai, P. R. China
1 shared publication
Latest Publications
- Open Access
- 9 February 2021
- Published by EDP Sciences
- Vol. 237, 03022
Theoretical and experimental study on vibration modal for simply supported bridge
For the highway bridges with small or medium span, a vehicle will stay on the bridge after the excitation. So the measured values of the vibration characteristics of the bridge are related to the vehiclebridge system. In order to analyse the natural vibration characteristics of simply supported bridge and the loaded frequency of vehicle-bridge system, theoretical analysis was carried out firstly, then the simply supported beam calculation model was built based on finite element method, and the results were compared with the measured values. The finite element model of a mass block-simply supported beam system was built by regarding the vehicles as a concentrated mass block attached. Both the vibration modals of the bridge system and the loaded frequencies of the vehicle-bridge system under diffident vehicle positions were obtained by software analysing. As a result, the variation characteristics of the loaded frequency for this simply supported bridge were extracted and discussed through the comparison of the results from both finite element method and the measured.
- 9 February 2021
- Published by EDP Sciences
- Vol. 237, 03022
Open AccessTheoretical and experimental study on vibration modal for simply supported bridge
For the highway bridges with small or medium span, a vehicle will stay on the bridge after the excitation. So the measured values of the vibration characteristics of the bridge are related to the vehiclebridge system. In order to analyse the natural vibration characteristics of simply supported bridge and the loaded frequency of vehicle-bridge system, theoretical analysis was carried out firstly, then the simply supported beam calculation model was built based on finite element method, and the results were compared with the measured values. The finite element model of a mass block-simply supported beam system was built by regarding the vehicles as a concentrated mass block attached. Both the vibration modals of the bridge system and the loaded frequencies of the vehicle-bridge system under diffident vehicle positions were obtained by software analysing. As a result, the variation characteristics of the loaded frequency for this simply supported bridge were extracted and discussed through the comparison of the results from both finite element method and the measured.
- Open Access
- 9 February 2021
- Published by EDP Sciences
- Vol. 237, 01017
Review of research on high-temperature behavior of geopolymer paste
Geopolymer composites have been widely researched during recent years as an alternative to sustainable construction materials, which can minimize CO2 emission for its application of industry by-products. Past researches on geopolymer show that it has comparable strength and better high temperature stability compared to ordinary Portland cement. In this paper, the high-temperature behavior of geopolymer paste has been discussed through the last data regarding geopolymer, mainly including its bonding performance with steel, stress-strain characteristics, structural analysis of different observation scales and the performance of special geopolymer paste. In summary, some problems that need to be studied in future researches are put forward.
- 9 February 2021
- Published by EDP Sciences
- Vol. 237, 01017
Open AccessReview of research on high-temperature behavior of geopolymer paste
Geopolymer composites have been widely researched during recent years as an alternative to sustainable construction materials, which can minimize CO2 emission for its application of industry by-products. Past researches on geopolymer show that it has comparable strength and better high temperature stability compared to ordinary Portland cement. In this paper, the high-temperature behavior of geopolymer paste has been discussed through the last data regarding geopolymer, mainly including its bonding performance with steel, stress-strain characteristics, structural analysis of different observation scales and the performance of special geopolymer paste. In summary, some problems that need to be studied in future researches are put forward.
- Open Access
Influence of Redispersible Powder on Properties of Self-Leveling Mortar of Ternary Cementitious System
The self-leveling mortar (SLM) of a ternary cementitious system with different dosages of redispersible powder (RP) with ordinary Portland cement (OPC), sulfoaluminate cement (SAC), and calcium sulfate (CS) as cementitious materials was investigated with regard to fluidity, bond strength, shrinkage rate, abrasion resistance, flexural strength, and compressive strength. The performance parameters obtained from the experimental test for SLM were weighted values calculated with an analytic hierarchy process (AHP). The comprehensive index of performance was evaluated on the basis of a weighted-sum method, and the optimal dosage of RP was determined according to the comprehensive index. The experimental results demonstrated that the fluidity of SLM decreased with the increase in RP dosage at the beginning but then increased thereafter and decreased rapidly as the dosage went beyond 3.0%. The addition of RP resulted in a significant improvement in bond strength (of SLM), reduction in the shrinkage rate, abrasion loss, early flexural strength and compressive strength, and resistance to cracking. The properties of SLM with 3.0% RP can meet the requirements of the industrial standard for cementitious self-leveling floor mortar. Compared with the SLM without RP, the bond strength of SLM with 3.0% RP was increased by 46.7%, while the shrinkage rate and abrasion loss were reduced by 50% and 71.9% respectively. The weighted values of fluidity, compressive strength, flexural strength, stability, cohesiveness, and abrasion resistance were 0.422, 0.196, 0.196, 0.089, 0.058, and 0.039, respectively. A higher value of the comprehensive index generally denotes a better performance. The comprehensive index of SLM with 3.0% RP was the highest.
Open AccessInfluence of Redispersible Powder on Properties of Self-Leveling Mortar of Ternary Cementitious System
The self-leveling mortar (SLM) of a ternary cementitious system with different dosages of redispersible powder (RP) with ordinary Portland cement (OPC), sulfoaluminate cement (SAC), and calcium sulfate (CS) as cementitious materials was investigated with regard to fluidity, bond strength, shrinkage rate, abrasion resistance, flexural strength, and compressive strength. The performance parameters obtained from the experimental test for SLM were weighted values calculated with an analytic hierarchy process (AHP). The comprehensive index of performance was evaluated on the basis of a weighted-sum method, and the optimal dosage of RP was determined according to the comprehensive index. The experimental results demonstrated that the fluidity of SLM decreased with the increase in RP dosage at the beginning but then increased thereafter and decreased rapidly as the dosage went beyond 3.0%. The addition of RP resulted in a significant improvement in bond strength (of SLM), reduction in the shrinkage rate, abrasion loss, early flexural strength and compressive strength, and resistance to cracking. The properties of SLM with 3.0% RP can meet the requirements of the industrial standard for cementitious self-leveling floor mortar. Compared with the SLM without RP, the bond strength of SLM with 3.0% RP was increased by 46.7%, while the shrinkage rate and abrasion loss were reduced by 50% and 71.9% respectively. The weighted values of fluidity, compressive strength, flexural strength, stability, cohesiveness, and abrasion resistance were 0.422, 0.196, 0.196, 0.089, 0.058, and 0.039, respectively. A higher value of the comprehensive index generally denotes a better performance. The comprehensive index of SLM with 3.0% RP was the highest.
- Open Access
- 24 January 2020
- Published by EDP Sciences
- Vol. 143, 01048
Seismic performance of double skin semi-base-isolated structures
Base isolation technology is a popular and powerful isolation technology. This technique can greatly reduce the seismic response of the structure, so as to reduce the damage to the structure. Base isolation method decouples the superstructure from the base by installing a flexible layer under each column to reduce dynamic response in the earthquake and elongate the time period of structures due to its inherent flexibility. However, the long time period causes large displacement. In addition, base isolation devices are highly vulnerable due to uplift forces produced by lateral force resisting systems (LFRS). In this study, an adjustable structure with a new configuration, namely double skin semi-base-isolated (SBI) structure is presented to solve the above problems. The LFRS is omitted in the proposed SBI structure and the time period and displacement are reduced compared to the conventional base-isolated structure. The forcedeformation behavior of an isolator is modeled as bi-linear hysteretic behavior which can be effectively used to model all isolation system in practice. This study investigates the seismic performance of 10-story double skin SBI reinforced concrete (RC) structure under far-fault earthquake ground motion by numerical method. Results demonstrate that the SBI system is significantly adjustable with the use of RC coupling beams between the inner core and outer frames. By increasing or reducing the number of connected floors in the SBI system, dynamic behaviors of the SBI system can be changed. The adjusted structure can be created by adding and removing RC coupling beams at every arbitrary floor level.
- 24 January 2020
- Published by EDP Sciences
- Vol. 143, 01048
Open AccessSeismic performance of double skin semi-base-isolated structures
Base isolation technology is a popular and powerful isolation technology. This technique can greatly reduce the seismic response of the structure, so as to reduce the damage to the structure. Base isolation method decouples the superstructure from the base by installing a flexible layer under each column to reduce dynamic response in the earthquake and elongate the time period of structures due to its inherent flexibility. However, the long time period causes large displacement. In addition, base isolation devices are highly vulnerable due to uplift forces produced by lateral force resisting systems (LFRS). In this study, an adjustable structure with a new configuration, namely double skin semi-base-isolated (SBI) structure is presented to solve the above problems. The LFRS is omitted in the proposed SBI structure and the time period and displacement are reduced compared to the conventional base-isolated structure. The forcedeformation behavior of an isolator is modeled as bi-linear hysteretic behavior which can be effectively used to model all isolation system in practice. This study investigates the seismic performance of 10-story double skin SBI reinforced concrete (RC) structure under far-fault earthquake ground motion by numerical method. Results demonstrate that the SBI system is significantly adjustable with the use of RC coupling beams between the inner core and outer frames. By increasing or reducing the number of connected floors in the SBI system, dynamic behaviors of the SBI system can be changed. The adjusted structure can be created by adding and removing RC coupling beams at every arbitrary floor level.
- Open Access
- 1 August 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 592 (1) , 012003
Study on Properties of Binary Composite Cementitious Self-leveling Mortar
The binary composite cementitious self-leveling mortar is an important development direction of modern building construction. At present, there are great differences in opinions on the mixing proportion of Portland cement and aluminate cement or sulphoaluminate cement in binary system and there are few literatures comparing the fluidity and strength of the two kinds of mortar. In this paper, the fluidity, flexural strength and compressive strength of the two kinds of mortar with different dosages were compared. The research results showed that the addition of aluminate cement and sulphoaluminate cement could reduce the initial fluidity and 20min fluidity of mortars, but the decreasing degree was different. The influence of different dosages of aluminate cement and sulphoaluminate cement on the flexural strength and compressive strength of mortars was obviously different. When the dosage of aluminate cement was 0-10%, the flexural strength and 1d compressive strength of mortar could be improved remarkably. When the dosage was higher than 10%, the strengths were obviously reduced, even lower than the strengths of Portland cement mortar. The flexural strength of the mortar increased with the increase of sulphoaluminate cement in the range of test dosages, but the 1d compressive strength had little difference. When the dosage was 10%-20%, the influences of the two kinds of cement on the 28d compressive strength of mortars were basically consistent and both could improve the 28d compressive strength of mortars.
- 1 August 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 592 (1) , 012003
Open AccessStudy on Properties of Binary Composite Cementitious Self-leveling Mortar
The binary composite cementitious self-leveling mortar is an important development direction of modern building construction. At present, there are great differences in opinions on the mixing proportion of Portland cement and aluminate cement or sulphoaluminate cement in binary system and there are few literatures comparing the fluidity and strength of the two kinds of mortar. In this paper, the fluidity, flexural strength and compressive strength of the two kinds of mortar with different dosages were compared. The research results showed that the addition of aluminate cement and sulphoaluminate cement could reduce the initial fluidity and 20min fluidity of mortars, but the decreasing degree was different. The influence of different dosages of aluminate cement and sulphoaluminate cement on the flexural strength and compressive strength of mortars was obviously different. When the dosage of aluminate cement was 0-10%, the flexural strength and 1d compressive strength of mortar could be improved remarkably. When the dosage was higher than 10%, the strengths were obviously reduced, even lower than the strengths of Portland cement mortar. The flexural strength of the mortar increased with the increase of sulphoaluminate cement in the range of test dosages, but the 1d compressive strength had little difference. When the dosage was 10%-20%, the influences of the two kinds of cement on the 28d compressive strength of mortars were basically consistent and both could improve the 28d compressive strength of mortars.
- Open Access
- 1 January 2018
- Published by Wiley in Advances in Civil Engineering
- Vol. 2018 (1)
Seismic Performance Evaluation of Double‐Skin Semi‐Base‐Isolated Building Using Incremental Dynamic Analysis
Base isolation is a widely accepted earthquake damage prevention technique. This method decouples the superstructure from the base by putting a flexible layer under each column, thereby elongating the time period of structures. Semi‐base isolation (SBI) in double‐skin structures is an effective technique to reduce the dynamic responses of structures due to earthquake motions, by utilizing the isolation devices in part of it instead of the entire base. This study presents a double‐skin structure consisting of outer fixed base frames with shear walls that have been detached from the inner core with a minor gap. The inner core of the structure has been dissociated from the base using the elastomeric bearings. Seismic response of 10‐story double‐skin structure with inner isolated core was compared to that of inner fixed base core to consider the yielding and collapse probability of the structure using the incremental dynamic analyses (IDA). The results showed that the time period in SBI buildings can be adjusted with the use of coupling beams between the inner and outer frames. Also, the time period and interstory drift ratio are both reduced as more floors are given coupling beams. However, these coupling beams are the most effective at the topmost floors.
- 1 January 2018
- Published by Wiley in Advances in Civil Engineering
- Vol. 2018 (1)
Open AccessSeismic Performance Evaluation of Double‐Skin Semi‐Base‐Isolated Building Using Incremental Dynamic Analysis
Base isolation is a widely accepted earthquake damage prevention technique. This method decouples the superstructure from the base by putting a flexible layer under each column, thereby elongating the time period of structures. Semi‐base isolation (SBI) in double‐skin structures is an effective technique to reduce the dynamic responses of structures due to earthquake motions, by utilizing the isolation devices in part of it instead of the entire base. This study presents a double‐skin structure consisting of outer fixed base frames with shear walls that have been detached from the inner core with a minor gap. The inner core of the structure has been dissociated from the base using the elastomeric bearings. Seismic response of 10‐story double‐skin structure with inner isolated core was compared to that of inner fixed base core to consider the yielding and collapse probability of the structure using the incremental dynamic analyses (IDA). The results showed that the time period in SBI buildings can be adjusted with the use of coupling beams between the inner and outer frames. Also, the time period and interstory drift ratio are both reduced as more floors are given coupling beams. However, these coupling beams are the most effective at the topmost floors.
- 1 December 2017
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Bridge Engineering
- Vol. 170 (4) , 255-270
Performance of corroded bridge piers under cyclic loading
The presence of chloride ions causes reinforced-concrete (RC) bridge piers in a corrosive environment to suffer from different degrees of corrosion damage. Investigation of the seismic performance of corroded RC bridge piers using cyclic loading is therefore of great value. In total, eight RC column pier specimens were experimentally investigated for their seismic performance and the influence of steel corrosion and axial repeated loading on that performance. It was demonstrated that corrosion had a significant influence on yield strength and ultimate load-bearing capacity of the column piers. Compared with non-corroded specimens, the load-bearing capacity was 18·27% lower when the corrosion of the longitudinal steel bar was 7·16%. Axial repeated loading had no significant influence on mechanical properties of the piers. Finite-element analysis was conducted to assess the effect of different parameters on the seismic performance of the piers, including concrete strength, longitudinal reinforcement ratio, axial compression ratio, height of column and stirrup ratio. As the ratio of axial compression stress to the strength was increased from 0·1 to 0·4, the maximum load-bearing capacity was increased by 27·3% from 55 kN to 70 kN. However, the ultimate displacement was significantly decreased by 42·9% from 35 mm to 20 mm.
- 1 December 2017
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Bridge Engineering
- Vol. 170 (4) , 255-270
Performance of corroded bridge piers under cyclic loading
The presence of chloride ions causes reinforced-concrete (RC) bridge piers in a corrosive environment to suffer from different degrees of corrosion damage. Investigation of the seismic performance of corroded RC bridge piers using cyclic loading is therefore of great value. In total, eight RC column pier specimens were experimentally investigated for their seismic performance and the influence of steel corrosion and axial repeated loading on that performance. It was demonstrated that corrosion had a significant influence on yield strength and ultimate load-bearing capacity of the column piers. Compared with non-corroded specimens, the load-bearing capacity was 18·27% lower when the corrosion of the longitudinal steel bar was 7·16%. Axial repeated loading had no significant influence on mechanical properties of the piers. Finite-element analysis was conducted to assess the effect of different parameters on the seismic performance of the piers, including concrete strength, longitudinal reinforcement ratio, axial compression ratio, height of column and stirrup ratio. As the ratio of axial compression stress to the strength was increased from 0·1 to 0·4, the maximum load-bearing capacity was increased by 27·3% from 55 kN to 70 kN. However, the ultimate displacement was significantly decreased by 42·9% from 35 mm to 20 mm.
- 1 July 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 22 (7)
Cyclic Behavior of Corroded Reinforced Concrete Bridge Piers
Corrosion damage is one of the main problems affecting the durability of concrete structures. Several corroded reinforced concrete (RC) railway bridges are located in regions of high seismic risk. Corroded bridge piers are often subjected to dynamic axial loads, such as the vertical pounding that occurs during earthquakes or due to railway trains. Repeated axial loading was used to simulate this vertical pounding effect. Therefore, the seismic performance of corroded RC structures under repeated axial and horizontal cyclic loading is an urgent issue. To investigate the influences of steel corrosion and repeated axial loading on the seismic performance of a column pier, eight RC column specimens were experimentally investigated. The results indicated that corrosion significantly influences the yield strength and load bearing capacity of a column. The load bearing capacities of the corroded specimens decreased by 18.27% compared with noncorroded specimens when the longitudinal loss of steel mass was 7.16%. Repeated axial loading did not significantly influence the mechanical properties of the corroded RC piers. Cyclic tests were performed to validate a finite-element model that was used to assess the effects of corrosion level on the seismic performance of columns. The level of steel corrosion ranged from 0 to 28%. According to the finite-element analysis, the yield strength (35%) and ultimate displacement (34%) decreased with increasing corrosion.
- 1 July 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 22 (7)
Cyclic Behavior of Corroded Reinforced Concrete Bridge Piers
Corrosion damage is one of the main problems affecting the durability of concrete structures. Several corroded reinforced concrete (RC) railway bridges are located in regions of high seismic risk. Corroded bridge piers are often subjected to dynamic axial loads, such as the vertical pounding that occurs during earthquakes or due to railway trains. Repeated axial loading was used to simulate this vertical pounding effect. Therefore, the seismic performance of corroded RC structures under repeated axial and horizontal cyclic loading is an urgent issue. To investigate the influences of steel corrosion and repeated axial loading on the seismic performance of a column pier, eight RC column specimens were experimentally investigated. The results indicated that corrosion significantly influences the yield strength and load bearing capacity of a column. The load bearing capacities of the corroded specimens decreased by 18.27% compared with noncorroded specimens when the longitudinal loss of steel mass was 7.16%. Repeated axial loading did not significantly influence the mechanical properties of the corroded RC piers. Cyclic tests were performed to validate a finite-element model that was used to assess the effects of corrosion level on the seismic performance of columns. The level of steel corrosion ranged from 0 to 28%. According to the finite-element analysis, the yield strength (35%) and ultimate displacement (34%) decreased with increasing corrosion.
- 1 August 2015
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 18 (8) , 1257-1271
Effects of Reinforcement Corrosion and Repeated Loads on Performance of Reinforced Concrete Beam
The effects of both steel corrosion and repeated loading on performance of reinforced concrete beam were investigated. Repeated loads were applied to corroded reinforced concrete specimens with corrosion levels ranging from 0% to 5%. The experiments were conducted for the deflection, cracking, stiffness, bearing capacity and failure type of the corroded beams. For corrosion levels less than 5%, the residual deflection was about 3% of the maximum value of failure deflection. The deflection of beams of high corrosion levels were generally greater than those of low corrosion levels, while the flexural rigidity of the high corrosion levels decreased more in value than those of low corrosion levels. The failure modes of beams changed from plastic type to brittle type with the increase of corrosion level.
- 1 August 2015
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 18 (8) , 1257-1271
Effects of Reinforcement Corrosion and Repeated Loads on Performance of Reinforced Concrete Beam
The effects of both steel corrosion and repeated loading on performance of reinforced concrete beam were investigated. Repeated loads were applied to corroded reinforced concrete specimens with corrosion levels ranging from 0% to 5%. The experiments were conducted for the deflection, cracking, stiffness, bearing capacity and failure type of the corroded beams. For corrosion levels less than 5%, the residual deflection was about 3% of the maximum value of failure deflection. The deflection of beams of high corrosion levels were generally greater than those of low corrosion levels, while the flexural rigidity of the high corrosion levels decreased more in value than those of low corrosion levels. The failure modes of beams changed from plastic type to brittle type with the increase of corrosion level.
- 21 April 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 463-471
Reliability-Based Safety Assessment of Bridge Members on Monitored Live Load Effects
For decades, monitoring concepts for structural systems have been subjected to a rapid development process. They have become more and more important in the intervention planning (e.g., maintenance, repair) on new and existing structures. Nevertheless, there is still a strong need for the efficient use of structural monitoring data in the reliability assessment. In an extended sense, structural monitoring can be considered similar to quality assurance and acceptance sampling, since it is not practically possible to continuously monitor all performance indicators in all critical sections of an entire structural system. The aim of this paper is two-fold: (a) the probability density of strain of sensor locations based on the monitoring data was researched; and (b) to shift the reliability index to the differentiation value. An illustration of the proposed approach is provided on Hongdao Bay Bridge located in Qingdao, China. The monitoring system has been working since 2011.
- 21 April 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 463-471
Reliability-Based Safety Assessment of Bridge Members on Monitored Live Load Effects
For decades, monitoring concepts for structural systems have been subjected to a rapid development process. They have become more and more important in the intervention planning (e.g., maintenance, repair) on new and existing structures. Nevertheless, there is still a strong need for the efficient use of structural monitoring data in the reliability assessment. In an extended sense, structural monitoring can be considered similar to quality assurance and acceptance sampling, since it is not practically possible to continuously monitor all performance indicators in all critical sections of an entire structural system. The aim of this paper is two-fold: (a) the probability density of strain of sensor locations based on the monitoring data was researched; and (b) to shift the reliability index to the differentiation value. An illustration of the proposed approach is provided on Hongdao Bay Bridge located in Qingdao, China. The monitoring system has been working since 2011.