JLJosep Maria Lopez

Josep Maria Lopez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Josep Maria Lopez has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Dolors Puigjaner

    Departament d’Enginyeria Informàtica i Matemàtiques, Universitat Rovira i Virgili, Tarragona, Spain

    6 shared publications
  • Joan Herrero

    Departament d'Enginyeria Química Universitat Rovira i Virgili Tarragona Catalunya Spain

    6 shared publications
  • Gerard Fortuny

    Departament d’Enginyeria Informàtica i Matemàtiques, Universitat Rovira i Virgili, Tarragona, Spain

    5 shared publications
  • Francesc Marimon

    Departament de Medicina i Cirurgia, Universitat Rovira i Virgili, Hospital Sant Joan, Reus, Catalunya, Spain

    3 shared publications
  • Gerard Fortuny

    Departament d'Enginyeria Informàtica i Matemàtiques Universitat Rovira i Virgili Tarragona Catalunya Spain

    3 shared publications
  • Dolors Puigjaner

    Departament d'Enginyeria Informàtica i Matemàtiques Universitat Rovira i Virgili Tarragona Catalunya Spain

    2 shared publications

Latest Publications

  • Open Access

    A virtual simulation approach to assess the effect of trocar-site placement and scar characteristics on the abdominal wall biomechanics

    by Lluís Tuset, Manuel López-Cano, Gerard Fortuny, Josep M. López, Joan Herrero, Dolors Puigjaner

    Analyses of registries and medical imaging suggest that laparoscopic surgery may be penalized with a high incidence of trocar-site hernias (TSH). In addition to trocar diameter, the location of the surgical wound (SW) may affect TSH incidence. The intra-abdominal pressure (IAP) exerted on the abdominal wall (AW) might also influence the appearance of TSH. In the present study, we used finite element (FE) simulations to predict the influence of trocar location and SW characteristics (stiffness) on the mechanical behavior of the AW subject to an IAP. Two models of laparoscopy patterns on the AW, with trocars in the 5–12 mm range, were generated. FE simulations for IAP values within the 4 kPa–20 kPa range were carried out using the Code Aster open-source software. Different stiffness levels of the SW tissue were considered. We found that midline-located surgical wounds barely deformed, even though they moved outwards along with the regular LA tissue. Laterally located SWs hardly changed their location but they experienced significant variations in their volume and shape. The amount of deformation of lateral SWs was found to strongly depend on their stiffness. Trocar incisions placed in a LA with non-diastatic dimensions do not compromise its mechanical integrity. The more lateral the trocars are placed, the greater is their deformation, regardless of their size. Thus, to prevent TSH it might be advisable to close lateral trocars with a suture, or even use a prosthetic reinforcement depending on the patient's risk factors (e.g., obesity).


  • Open Access

    The effect of thoracic dimensions on compression depth during cardiopulmonary resuscitation

    by Jafar Moradicheghamahi, Gerard Fortuny, Josep M. López, Dolors Puigjaner, Joan Herrero, Youcef Azeli

    The effect of the dimensions of the thoracic cage on the resuscitation outcome of cardiopulmonary resuscitation (CPR) maneuvers has long been debated. In this study, the effect of changes in the rib cage dimensions on the achieved compression depth was investigated using finite element simulations. A total of 216 different rib cage geometry models were considered and, in each case, the result of applying different levels of compression force up to 600 N were simulated. The Haller Index of the rib cage is defined as the ratio of the transverse diameter and the antero‐posterior diameter. Our results suggest that, with a fixed level of compression force, performing CPR on rib cages having a low Haller Index and/or a larger height leads to compression depths below the average. Alternatively, if a target compression depth is set for CPR, in general a lower compression force would be required for individuals with higher Haller Index and/or lower chest height. In addition, present results indicate that wider chested individuals will experience lower stress levels on their ribs to achieve the required CPR target depth. Moreover, in the present study we propose predictive models, based on anthropometric parameters, for compression depth and rib stress during chest compressions. In particular, the model suggests that in future correlations of empirical CPR data the patients' Haller index and vertical (sagittal) cross‐area are the best parameters to be used as independent variables in a fit.


  • Open Access

    Biomechanical response of human rib cage to cardiopulmonary resuscitation maneuvers: Effects of the compression location

    by Mario Suazo, Joan Herrero, Gerard Fortuny, Dolors Puigjaner, Josep M. López

    The biomechanical response of a human rib cage to cardiopulmonary resuscitation maneuvers was investigated by means of finite element simulations. We analyzed the effect of the location where the force was applied on the achieved compression depths and stress levels experienced by the breastbone and ribs. For compression locations on the breastbone, a caudal shift of the application area towards the breastbone tip resulted in a 17% reduction of the force required to achieve a target 5 cm compression depth. We found that the use of compression regions located on the costal cartilages would involve higher risk of rib fractures.


  • Register of Dry Stone Domes. Simplified Method for Point Clouds

    by Cèlia Mallafrè Balsells, Josep Maria López Besora, Agustí Costa Jover, Sergio Coll Pla


  • Hemodynamic effects of blood clots trapped by an inferior vena cava filter

    by Josep M. López, Gerard Fortuny, Dolors Puigjaner, Joan Herrero, Francesc Marimon

    The alteration of blood flow around an OPTEASE inferior vena cava filter with one or two blood clots attached was investigated by means of computational fluid dynamics. We used a patient‐specific vein wall geometry, and we generated different clot models with shapes adapted to the filter and vein wall geometries. A total of eight geometries, with one or two clots and a total clot volume of 0.5 or 1 cm3, were considered. A non‐Newtonian model for blood viscosity was adopted and the possible development of turbulence was accounted for by means of a three‐equation model. Two blood flow rates were considered for each case, representative for rest and exercise conditions. In exercise conditions, flow unsteadiness and even turbulence was detected in some cases. Pressure and wall shear stress (WSS) distributions were modified in all cases. Clots attached to the filter downstream basket considerably increased averaged WSS values by up to almost 50%. In all the cases a flow recirculation region appeared downstream of the clot. The degree of flow stagnation in these regions, an indicator of propensity to thrombogenesis, was estimated in terms of mean residence times and mean blood viscosity. High levels of flow stagnation were detected in rest conditions in the wake of those clots that were placed upstream from the filter. Our results suggest that one downstream placed big clot, showing a higher tendency to induce flow instabilities and turbulence, might be more harmful than two small clots placed in tandem.


  • Implementation of a new constitutive model for abdominal muscles

    by Lluís Tuset, Gerard Fortuny, Joan Herrero, Dolors Puigjaner, Josep M. López


  • A comparative CFD study of four inferior vena cava filters

    by Josep M. López, Gerard Fortuny, Dolors Puigjaner, Joan Herrero, Francesc Marimon

    Computational fluid dynamics was used to simulate the flow of blood within an inferior vena cava (IVC) geometry model that was reconstructed from computed tomography images obtained from a real patient. The main novelty of the present work is that we simulated the implantation of 4 different filter models in this realistic IVC geometry. We considered different blood flow rates in the range between Vin=20 and Vin=80 cm3/s, and all simulations were performed with both the Newtonian and a non‐Newtonian model for the blood viscosity. We compared the hemodynamics performance of the different filter models, and we paid a special attention to the total drag force, Fd, exerted by the blood flow on the filter surface. This force is the sum of 2 contributions: the viscous skin friction force, which was found to be roughly proportional to the filter surface area, and the pressure force, which depended on the particular filter geometry design. The Fd force is relevant because it must be balanced by the total force exerted by the filter hooks/struts on the IVC wall at the attachment locations. For the highest Vin value investigated, the variation in Fd among filters was from 116 to 308 dyne. We also showed how the present results can be extrapolated to obtain good estimates of the drag forces if the blood viscosity levels change, ie, if the patient with a filter implanted is treated with anticoagulant therapy.


  • Variation and correlation of end–tidal CO2 and amplitude spectrum area in a refractory ventricular fibrillation. A case from the ReCaPTa study

    by Youcef Azeli, Joan Herrero, Gerard Fortuny, Dolors Puigjaner, Josep Maria Lopez, Anna Puig, Xavier Jiménez-Fábrega, Alfredo Bardají


  • Effects of walking in deep venous thrombosis: a new integrated solid and fluid mechanics model

    by Josep M. López, Gerard Fortuny, Dolors Puigjaner, Joan Herrero, Francesc Marimon, Josep Garcia‐Bennett

    Deep venous thrombosis (DVT) is a common disease. Large thrombi in venous vessels cause bad blood circulation and pain; and when a blood clot detaches from a vein wall, it causes an embolism whose consequences range from mild to fatal. Walking is recommended to DVT patients as a therapeutical complement. In this study the mechanical effects of walking on a specific patient of DVT were simulated by means of an unprecedented integration of 3 elements: a real geometry, a biomechanical model of body tissues, and a computational fluid dynamics study. A set of computed tomography images of a patient's leg with a thrombus in the popliteal vein was employed to reconstruct a geometry model. Then a biomechanical model was used to compute the new deformed geometry of the vein as a function of the fiber stretch level of the semimembranosus muscle. Finally, a computational fluid dynamics study was performed to compute the blood flow and the wall shear stress (WSS) at the vein and thrombus walls. Calculations showed that either a lengthening or shortening of the semimembranosus muscle led to a decrease of WSS levels up to 10%. Notwithstanding, changes in blood viscosity properties or blood flow rate may easily have a greater impact in WSS.