Gerard Fortuny
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gerard Fortuny has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Dolors Puigjaner
Departament d’Enginyeria Informàtica i Matemàtiques, Universitat Rovira i Virgili, Tarragona, Spain
7 shared publications Joan Herrero
Departament d’Enginyeria Química, Universitat Rovira i Virgili, Tarragona, Spain
7 shared publications- Josep Maria Lopez
Departament d'Enginyeria Informàtica i Matemàtiques, Universitat Rovira i Virgili, Av Països Catalans 26, Tarragona, Catalunya, Spain
5 shared publications Dolors Puigjaner
Departament d’Enginyeria Informàtica i Matemàtiques, Universitat Rovira i Virgili, Tarragona, Spain
4 shared publications- Joan Herrero
Departament d’Enginyeria Química, Universitat Rovira i Virgili, Tarragona, Spain
4 shared publications Josep M. López
Departament d’Enginyeria Informàtica i Matemàtiques, Universitat Rovira i Virgili, Tarragona, Spain
4 shared publications
Latest Publications
- Open Access
- 13 February 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
A virtual simulation approach to assess the effect of trocar-site placement and scar characteristics on the abdominal wall biomechanics
Analyses of registries and medical imaging suggest that laparoscopic surgery may be penalized with a high incidence of trocar-site hernias (TSH). In addition to trocar diameter, the location of the surgical wound (SW) may affect TSH incidence. The intra-abdominal pressure (IAP) exerted on the abdominal wall (AW) might also influence the appearance of TSH. In the present study, we used finite element (FE) simulations to predict the influence of trocar location and SW characteristics (stiffness) on the mechanical behavior of the AW subject to an IAP. Two models of laparoscopy patterns on the AW, with trocars in the 5–12 mm range, were generated. FE simulations for IAP values within the 4 kPa–20 kPa range were carried out using the Code Aster open-source software. Different stiffness levels of the SW tissue were considered. We found that midline-located surgical wounds barely deformed, even though they moved outwards along with the regular LA tissue. Laterally located SWs hardly changed their location but they experienced significant variations in their volume and shape. The amount of deformation of lateral SWs was found to strongly depend on their stiffness. Trocar incisions placed in a LA with non-diastatic dimensions do not compromise its mechanical integrity. The more lateral the trocars are placed, the greater is their deformation, regardless of their size. Thus, to prevent TSH it might be advisable to close lateral trocars with a suture, or even use a prosthetic reinforcement depending on the patient's risk factors (e.g., obesity).
- 13 February 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
Open AccessA virtual simulation approach to assess the effect of trocar-site placement and scar characteristics on the abdominal wall biomechanics
Analyses of registries and medical imaging suggest that laparoscopic surgery may be penalized with a high incidence of trocar-site hernias (TSH). In addition to trocar diameter, the location of the surgical wound (SW) may affect TSH incidence. The intra-abdominal pressure (IAP) exerted on the abdominal wall (AW) might also influence the appearance of TSH. In the present study, we used finite element (FE) simulations to predict the influence of trocar location and SW characteristics (stiffness) on the mechanical behavior of the AW subject to an IAP. Two models of laparoscopy patterns on the AW, with trocars in the 5–12 mm range, were generated. FE simulations for IAP values within the 4 kPa–20 kPa range were carried out using the Code Aster open-source software. Different stiffness levels of the SW tissue were considered. We found that midline-located surgical wounds barely deformed, even though they moved outwards along with the regular LA tissue. Laterally located SWs hardly changed their location but they experienced significant variations in their volume and shape. The amount of deformation of lateral SWs was found to strongly depend on their stiffness. Trocar incisions placed in a LA with non-diastatic dimensions do not compromise its mechanical integrity. The more lateral the trocars are placed, the greater is their deformation, regardless of their size. Thus, to prevent TSH it might be advisable to close lateral trocars with a suture, or even use a prosthetic reinforcement depending on the patient's risk factors (e.g., obesity).
- Open Access
- 28 March 2022
- Published by Springer Nature in BMC Cancer
- Vol. 22 (1) , 1-10
Biomechanical modelling of the pelvic system: improving the accuracy of the location of neoplasms in MRI-TRUS fusion prostate biopsy
An accurate knowledge of the relocation of prostate neoplasms during biopsy is of great importance to reduce the number of false negative results. Prostate neoplasms are visible in magnetic resonance images (MRI) but it is difficult for the practitioner to locate them at the time of performing a transrectal ultrasound (TRUS) guided biopsy. In this study, we present a new methodology, based on simulation, that predicts both prostate deformation and lesion migration during the biopsy. A three-dimensional (3-D) anatomy model of the pelvic region, based on medical images, is constructed. A finite element (FE) numerical simulation of the organs motion and deformation as a result of the pressure exerted by the TRUS probe is carried out using the Code-Aster open-source computer software. Initial positions of potential prostate lesions prior to biopsy are taken into consideration and the final location of each lesion is targeted in the FE simulation output. Our 3-D FE simulations show that the effect of the pressure exerted by the TRUS probe is twofold as the prostate experiences both a motion and a deformation of its original shape. We targeted the relocation of five small prostate lesions when the TRUS probe exerts a force of 30 N on the rectum inner wall. The distance travelled by these lesions ranged between 5.6 and 13.9 mm. Our new methodology can help to predict the location of neoplasms during a prostate biopsy but further studies are needed to validate our results. Moreover, the new methodology is completely developed on open-source software, which means that its implementation would be affordable to all healthcare providers.
- 28 March 2022
- Published by Springer Nature in BMC Cancer
- Vol. 22 (1) , 1-10
Open AccessBiomechanical modelling of the pelvic system: improving the accuracy of the location of neoplasms in MRI-TRUS fusion prostate biopsy
An accurate knowledge of the relocation of prostate neoplasms during biopsy is of great importance to reduce the number of false negative results. Prostate neoplasms are visible in magnetic resonance images (MRI) but it is difficult for the practitioner to locate them at the time of performing a transrectal ultrasound (TRUS) guided biopsy. In this study, we present a new methodology, based on simulation, that predicts both prostate deformation and lesion migration during the biopsy. A three-dimensional (3-D) anatomy model of the pelvic region, based on medical images, is constructed. A finite element (FE) numerical simulation of the organs motion and deformation as a result of the pressure exerted by the TRUS probe is carried out using the Code-Aster open-source computer software. Initial positions of potential prostate lesions prior to biopsy are taken into consideration and the final location of each lesion is targeted in the FE simulation output. Our 3-D FE simulations show that the effect of the pressure exerted by the TRUS probe is twofold as the prostate experiences both a motion and a deformation of its original shape. We targeted the relocation of five small prostate lesions when the TRUS probe exerts a force of 30 N on the rectum inner wall. The distance travelled by these lesions ranged between 5.6 and 13.9 mm. Our new methodology can help to predict the location of neoplasms during a prostate biopsy but further studies are needed to validate our results. Moreover, the new methodology is completely developed on open-source software, which means that its implementation would be affordable to all healthcare providers.
- Open Access
- 3 March 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Virtual simulation of the biomechanics of the abdominal wall with different stoma locations
An ostomy is a surgical procedure by which an artificial opening in the abdominal wall, known as a stoma, is created. We assess the effects of stoma location on the abdominal wall mechanics. We perform three-dimensional finite element simulations on an anatomy model which was generated on the basis of medical images. Our simulation methodology is entirely based on open source software. We consider seventeen different locations for the stoma incision (trephine) and we simulate the mechanical response of the abdominal wall when an intraabdominal pressure as high as 20 kPa is applied. We focus on factors related to the risk of parastomal hernia development such as the deformation experienced by the abdominal wall, the stress levels supported by its tissues and the corresponding level of trephine enlargement. No significant dependence was found between stoma location and the levels of abdominal wall deformations or stress supported by tissues, except for the case with a stoma located on the linea alba. Trephine perimeter and area respectively increased by as much as $$44\%$$ and $$85\%$$ . The level of trephine deformation depends on stoma location with considerably higher trephine enlargements found in stomas laterally located with respect to the rectus abdominis muscle.- 3 March 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Open AccessVirtual simulation of the biomechanics of the abdominal wall with different stoma locations
An ostomy is a surgical procedure by which an artificial opening in the abdominal wall, known as a stoma, is created. We assess the effects of stoma location on the abdominal wall mechanics. We perform three-dimensional finite element simulations on an anatomy model which was generated on the basis of medical images. Our simulation methodology is entirely based on open source software. We consider seventeen different locations for the stoma incision (trephine) and we simulate the mechanical response of the abdominal wall when an intraabdominal pressure as high as 20 kPa is applied. We focus on factors related to the risk of parastomal hernia development such as the deformation experienced by the abdominal wall, the stress levels supported by its tissues and the corresponding level of trephine enlargement. No significant dependence was found between stoma location and the levels of abdominal wall deformations or stress supported by tissues, except for the case with a stoma located on the linea alba. Trephine perimeter and area respectively increased by as much as $$44\%$$ and $$85\%$$ . The level of trephine deformation depends on stoma location with considerably higher trephine enlargements found in stomas laterally located with respect to the rectus abdominis muscle. - Open Access
- 20 September 2021
- Published by Springer Nature in Research Square
Stoma location and Parastomal Hernia. A Virtual Simulation Approach.
An ostomy is a surgical procedure by which an artificial opening in the abdominal wall, known as a stoma, is created. We assessthe effects of stoma location on the abdominal wall mechanics. We perform three–dimensional finite element simulations on ananatomy model which was generated on the basis of medical images. Our simulation methodology is entirely based on opensource software. We consider seventeen different locations for the stoma incision (trephine) and we simulate the mechanicalresponse of the abdominal wall when an intraabdominal pressure as high as 20 kPa is applied. We focus on factors relatedto the risk of parastomal hernia development such as the deformation experienced by the abdominal wall, the stress levelssupported by its tissues and the corresponding level of trephine enlargement.No significant dependence was found between stoma location and the levels of abdominal wall deformations or stress supportedby tissues, except for the case with a stoma located on the linea alba. Trephine perimeter and area respectively increased byas much as 44% and 85%. The level of trephine deformation depends on stoma location with considerably higher trephineenlargements found in stomas laterally located with respect to the rectus abdominis muscle.
- 20 September 2021
- Published by Springer Nature in Research Square
Open AccessStoma location and Parastomal Hernia. A Virtual Simulation Approach.
An ostomy is a surgical procedure by which an artificial opening in the abdominal wall, known as a stoma, is created. We assessthe effects of stoma location on the abdominal wall mechanics. We perform three–dimensional finite element simulations on ananatomy model which was generated on the basis of medical images. Our simulation methodology is entirely based on opensource software. We consider seventeen different locations for the stoma incision (trephine) and we simulate the mechanicalresponse of the abdominal wall when an intraabdominal pressure as high as 20 kPa is applied. We focus on factors relatedto the risk of parastomal hernia development such as the deformation experienced by the abdominal wall, the stress levelssupported by its tissues and the corresponding level of trephine enlargement.No significant dependence was found between stoma location and the levels of abdominal wall deformations or stress supportedby tissues, except for the case with a stoma located on the linea alba. Trephine perimeter and area respectively increased byas much as 44% and 85%. The level of trephine deformation depends on stoma location with considerably higher trephineenlargements found in stomas laterally located with respect to the rectus abdominis muscle.
- Open Access
- 18 August 2021
- Published by Springer Nature in Research Square
Biomechanical Modeling of the Pelvic System: Improving the Accuracy of Prostate Lesions Location in MRI–TRUS Fusion
Background: An accurate knowledge of prostate lesions relocation during biopsy is of great importance to prevent mispositioning of the needle and thus reduce the chance of faulty biopsy results (false negatives). Prostate lesions are visible in magnetic resonance images (MRI) but it is difficult for the practitioner to locate them at the time of performing a transrectal ultrasound (TRUS) guided biopsy. In this study, we present a new methodology that predicts both prostate deformation and lesion migration during the biopsy.Methods: A thee-dimensional (3-D) anatomy model of the pelvic region, based on medical images, is constructed. A finite element (FE) simulation of the organs motion and deformation as a result of the pressure exerted by the TRUS probe was carried out using the code_aster open source software. Initial positions of potential prostate lesions prior to biopsy are taken into consideration and the final location of each lesion is targeted in the FE simulation output.Results: Our 3-D FE simulations show that the effect of the pressure exerted by the TRUS probe is twofold as the prostate experiences both a motion (in the absolute frame of reference) and a deformation of its original shape. We targeted the relocation of five small prostate lesions when the TRUS probe exerts a force of 30 N on the rectum inner wall. The distance traveled by these lesions ranged between 5.6 and 13.9 mm. Moreover, we showed that as a result of the deformation of the prostate the resulting lesion migration might be very difficult to predict if the biopsy practitioner has to rely exclusively on a visual comparison of axial or sagittal prostate slices taken from MRI and TRUS images.Conclusions: The preliminary results presented here show that our new methodology can be of great help for improving the prediction of cancerous lesions location when a TRUS guided biopsy is performed. Moreover, the new methodology is completely developed on open source software, which means that its implementation would be affordable even for healthcare providers with small budgets.
- 18 August 2021
- Published by Springer Nature in Research Square
Open AccessBiomechanical Modeling of the Pelvic System: Improving the Accuracy of Prostate Lesions Location in MRI–TRUS Fusion
Background: An accurate knowledge of prostate lesions relocation during biopsy is of great importance to prevent mispositioning of the needle and thus reduce the chance of faulty biopsy results (false negatives). Prostate lesions are visible in magnetic resonance images (MRI) but it is difficult for the practitioner to locate them at the time of performing a transrectal ultrasound (TRUS) guided biopsy. In this study, we present a new methodology that predicts both prostate deformation and lesion migration during the biopsy.Methods: A thee-dimensional (3-D) anatomy model of the pelvic region, based on medical images, is constructed. A finite element (FE) simulation of the organs motion and deformation as a result of the pressure exerted by the TRUS probe was carried out using the code_aster open source software. Initial positions of potential prostate lesions prior to biopsy are taken into consideration and the final location of each lesion is targeted in the FE simulation output.Results: Our 3-D FE simulations show that the effect of the pressure exerted by the TRUS probe is twofold as the prostate experiences both a motion (in the absolute frame of reference) and a deformation of its original shape. We targeted the relocation of five small prostate lesions when the TRUS probe exerts a force of 30 N on the rectum inner wall. The distance traveled by these lesions ranged between 5.6 and 13.9 mm. Moreover, we showed that as a result of the deformation of the prostate the resulting lesion migration might be very difficult to predict if the biopsy practitioner has to rely exclusively on a visual comparison of axial or sagittal prostate slices taken from MRI and TRUS images.Conclusions: The preliminary results presented here show that our new methodology can be of great help for improving the prediction of cancerous lesions location when a TRUS guided biopsy is performed. Moreover, the new methodology is completely developed on open source software, which means that its implementation would be affordable even for healthcare providers with small budgets.
- 22 April 2020
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 36 (7) , e3343
Hemodynamic effects of blood clots trapped by an inferior vena cava filter
The alteration of blood flow around an OPTEASE inferior vena cava filter with one or two blood clots attached was investigated by means of computational fluid dynamics. We used a patient‐specific vein wall geometry, and we generated different clot models with shapes adapted to the filter and vein wall geometries. A total of eight geometries, with one or two clots and a total clot volume of 0.5 or 1 cm3, were considered. A non‐Newtonian model for blood viscosity was adopted and the possible development of turbulence was accounted for by means of a three‐equation model. Two blood flow rates were considered for each case, representative for rest and exercise conditions. In exercise conditions, flow unsteadiness and even turbulence was detected in some cases. Pressure and wall shear stress (WSS) distributions were modified in all cases. Clots attached to the filter downstream basket considerably increased averaged WSS values by up to almost 50%. In all the cases a flow recirculation region appeared downstream of the clot. The degree of flow stagnation in these regions, an indicator of propensity to thrombogenesis, was estimated in terms of mean residence times and mean blood viscosity. High levels of flow stagnation were detected in rest conditions in the wake of those clots that were placed upstream from the filter. Our results suggest that one downstream placed big clot, showing a higher tendency to induce flow instabilities and turbulence, might be more harmful than two small clots placed in tandem.
- 22 April 2020
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 36 (7) , e3343
Hemodynamic effects of blood clots trapped by an inferior vena cava filter
The alteration of blood flow around an OPTEASE inferior vena cava filter with one or two blood clots attached was investigated by means of computational fluid dynamics. We used a patient‐specific vein wall geometry, and we generated different clot models with shapes adapted to the filter and vein wall geometries. A total of eight geometries, with one or two clots and a total clot volume of 0.5 or 1 cm3, were considered. A non‐Newtonian model for blood viscosity was adopted and the possible development of turbulence was accounted for by means of a three‐equation model. Two blood flow rates were considered for each case, representative for rest and exercise conditions. In exercise conditions, flow unsteadiness and even turbulence was detected in some cases. Pressure and wall shear stress (WSS) distributions were modified in all cases. Clots attached to the filter downstream basket considerably increased averaged WSS values by up to almost 50%. In all the cases a flow recirculation region appeared downstream of the clot. The degree of flow stagnation in these regions, an indicator of propensity to thrombogenesis, was estimated in terms of mean residence times and mean blood viscosity. High levels of flow stagnation were detected in rest conditions in the wake of those clots that were placed upstream from the filter. Our results suggest that one downstream placed big clot, showing a higher tendency to induce flow instabilities and turbulence, might be more harmful than two small clots placed in tandem.
- 1 October 2019
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 179, 104988
Implementation of a new constitutive model for abdominal muscles
- 1 October 2019
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 179, 104988
Implementation of a new constitutive model for abdominal muscles
- 23 November 2017
- Published by Elsevier in Resuscitation
- Vol. 122, e19-e20
Variation and correlation of end–tidal CO2 and amplitude spectrum area in a refractory ventricular fibrillation. A case from the ReCaPTa study
- 23 November 2017
- Published by Elsevier in Resuscitation
- Vol. 122, e19-e20
Variation and correlation of end–tidal CO2 and amplitude spectrum area in a refractory ventricular fibrillation. A case from the ReCaPTa study
- 9 August 2016
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 33 (5) , e2819
Effects of walking in deep venous thrombosis: a new integrated solid and fluid mechanics model
Deep venous thrombosis (DVT) is a common disease. Large thrombi in venous vessels cause bad blood circulation and pain; and when a blood clot detaches from a vein wall, it causes an embolism whose consequences range from mild to fatal. Walking is recommended to DVT patients as a therapeutical complement. In this study the mechanical effects of walking on a specific patient of DVT were simulated by means of an unprecedented integration of 3 elements: a real geometry, a biomechanical model of body tissues, and a computational fluid dynamics study. A set of computed tomography images of a patient's leg with a thrombus in the popliteal vein was employed to reconstruct a geometry model. Then a biomechanical model was used to compute the new deformed geometry of the vein as a function of the fiber stretch level of the semimembranosus muscle. Finally, a computational fluid dynamics study was performed to compute the blood flow and the wall shear stress (WSS) at the vein and thrombus walls. Calculations showed that either a lengthening or shortening of the semimembranosus muscle led to a decrease of WSS levels up to 10%. Notwithstanding, changes in blood viscosity properties or blood flow rate may easily have a greater impact in WSS.
- 9 August 2016
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 33 (5) , e2819
Effects of walking in deep venous thrombosis: a new integrated solid and fluid mechanics model
Deep venous thrombosis (DVT) is a common disease. Large thrombi in venous vessels cause bad blood circulation and pain; and when a blood clot detaches from a vein wall, it causes an embolism whose consequences range from mild to fatal. Walking is recommended to DVT patients as a therapeutical complement. In this study the mechanical effects of walking on a specific patient of DVT were simulated by means of an unprecedented integration of 3 elements: a real geometry, a biomechanical model of body tissues, and a computational fluid dynamics study. A set of computed tomography images of a patient's leg with a thrombus in the popliteal vein was employed to reconstruct a geometry model. Then a biomechanical model was used to compute the new deformed geometry of the vein as a function of the fiber stretch level of the semimembranosus muscle. Finally, a computational fluid dynamics study was performed to compute the blood flow and the wall shear stress (WSS) at the vein and thrombus walls. Calculations showed that either a lengthening or shortening of the semimembranosus muscle led to a decrease of WSS levels up to 10%. Notwithstanding, changes in blood viscosity properties or blood flow rate may easily have a greater impact in WSS.