MOMasahiro Okamura

Masahiro Okamura

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Masahiro Okamura has a total of 662 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Bayesian optimization of the relativistic heavy ion collider luminosity via s * control

    by Xiaofeng Gu, Benjamin Coe, Guillaume Robert-Demolaize, Takeshi Kanesue, Masahiro Okamura, William Fung, Yue Hao, Ji Qiang, Xiaoye S. Li, Yang Liu

    In order to aid in luminosity maximization at the interaction point (IP), the collision location s IP must be equivalent to the location of the minimum value of the beta function s *. Accurate optics measurements and s * movements are therefore essential to luminosity optimization. However, according to current Relativistic Heavy Ion Collider (RHIC) operations measurements, average horizontal beta beat measurements between operating IPs are around 20% along with significant variation in s * measurements. Precise control of the longitudinal beam waist position ( s *) has become a critical yet challenging knob for maximizing the luminosity of modern high-energy colliders, particularly with short bunch lengths and high crossing angles. We present the online application of Bayesian optimization (BO) using the GPTune framework to systematically tune sPHENIX luminosity via s * control at the Relativistic Heavy Ion Collider (RHIC). The GPTune framework was first validated at the RHIC Electron Beam Ion Source (EBIS), where it delivered up to a 70% increase in beam intensity over the baseline, although experienced operators could also achieve this performance with longer manual tuning. The framework was then deployed during sPHENIX operations at RHIC. Using an intensity-normalized Zero-Degree-Calorimeter (ZDC) signal as the objective (owing to the unavailability of the live sPHENIX MVTX signal), GPTune successfully identified local luminosity maxima, recovered from intentionally degraded s * configurations, and uncovered residual horizontal and vertical waist offsets in the interaction region. These results demonstrate the robustness and efficiency of Bayesian optimization for real-time collider tuning under noisy and time-varying conditions. The developed methodology with s * control provides a powerful new tool for precision luminosity optimization and will be especially valuable for next-generation short-bunch colliders such as the Electron-Ion Collider (EIC).

  • Open Access

    Experimental Validation of PHITS-Predicted Neutron Moderation and Transport Driven by 1H(7Li,n)7Be Inverse-Kinematics Reaction

    by Toshiro Sakabe, Madhawa Horana Gamage, Yu Fujiwara, Shunsuke Ikeda, Takeshi Kanesue, Antonino Cannavo, Kazumasa Takahashi, Masahiro Okamura

    The inverse-kinematics 1H(7Li,n)7Be reaction provides forward-directed neutrons and is a promising candidate for accelerator-based boron neutron capture therapy (BNCT) neutron sources. Reliable moderator design for this neutron source requires experimental validation of Monte Carlo calculations. The present study aims to evaluate the predictive capability of PHITS for neutron moderation and transport toward future BNCT BSA design. In this study, a moderator assembly consisting of low-carbon steel, polyethylene, and graphite blocks was irradiated with neutrons produced by a 16.5 MeV 7Li3+ beam incident on a 12 μm-thick polypropylene target at the Tandem Van de Graff facility at Brookhaven National Laboratory. The neutron response downstream of the assembly was measured using a cylindrical BF3 neutron detector and compared with 10B(n,[[EQUATION]])7Li reaction rates calculated using PHITS Monte Carlo simulation. Cross-section data for the Inverse-kinematics reaction, generated from ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE, were separately applied to evaluate nuclear-data dependence. This study also investigates the effects of thermal neutron scattering law (TSL) data for polyethylene and graphite in the simulations. As a result, when TSL data were applied to polyethylene and graphite in the moderator assemblies, the calculated and measured reaction rates showed reasonable overall agreement, with C/E values ranging from 0.65 to 0.96 across all IK-Frag datasets. These results provide experimental support for the PHITS framework for predicting moderated neutrons and its application to future moderator and beam-shaping design for inverse-kinematics accelerator-based BNCT neutron sources.

  • Open Access

    Overcoming the Space-Charge Brightness Barrier for Fully Stripped Heavy Ions by Direct Plasma Injection

    by Madhawa Horana Gamage, Masahiro Okamura, Antonino Cannavo, Kazumasa Takahashi, Shunsuke Ikeda, Takeshi Kanesue, Shota Ikeda, Chuan Zhang, Sergey Kondrashev, Giovanni Ceccio, et al.

    SUMMARY Space-charge forces during low-energy transport have long held highly charged heavy-ion beams orders of magnitude below proton-injector currents. Here we overcome this brightness barrier by direct plasma injection. A laser-produced plasma, radially confined by a solenoid field while expanding freely along the beam axis, is fed into a radio-frequency quadrupole without a conventional low-energy transport line. Fully stripped Li3+ and C6+ reach peak accelerated currents of 148 mA and 135 mA at 320 keV/u — to our knowledge the first to match the proton-injector class. The measured currents agree with space-charge-dominated simulations and are insensitive to further increases in injected current: the limit now lies in the accelerator, not the source. Transporting a quasi-neutral plasma rather than a charged-particle beam thus shifts the current limit from source to accelerator. Independent RF beam-loading measurements confirm these currents. These beams reach a regime relevant to FLASH radiotherapy and boron neutron capture therapy.

  • Open Access

    Performance assessment of PHITS simulations for the inverse-kinematic p( 7 Li,n) 7 Be reaction based on fast-neutron measurements with a diamond detector

    by T. Sakabe, S. MacLeod, Y. Fujiwara, M. Horana Gamage, S. Ikeda, T. Kanesue, A. Cannavo, K. Takahashi, G. Ceccio, M. Okamura

    The inverse-kinematics p( 7 Li,n) 7 Be reaction produces forward-focused neutron emission, offering enhanced usable flux and reduced shielding requirements. Reliable simulation of such neutron fields is essential for the development of compact accelerator-based neutron sources. In this study, a PHITS-based simulation framework for the reaction was experimentally assessed using fast-neutron measurements. Forward-directed neutrons were measured with a diamond neutron detector and quantitatively compared with simulations with newly prepared IK-Frag cross-section file based on the proton-induced reaction data in ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE. Measurements and simulations were performed for incident 7 Li 3+ energies ranging from 15.0 to 25.0 MeV using a 50 μm-thick polypropylene target. For all conditions, the PHITS-based simulation framework reproduced the deposited energy spectra at the correct order of magnitude. The comparison of deposited energy spectra in the diamond detector showed high correlation coefficients across all investigated energies, indicating reasonable agreement in spectral shape between simulations and measurements. This work represents an initial step toward establishing a benchmark for PHITS simulations of the inverse kinematic reaction between an incident lithium-ion and a proton target.

  • Open Access

    Nozzle geometry optimization for high-current aluminum ion beam acceleration via direct plasma injection scheme

    by M. Horana Gamage, G. Garty, A. Cannavo, S. Ikeda, T. Kanesue, T. Sakabe, S. Kondrashev, M. Okamura, G. Ceccio, K. Takahashi

    We report the generation of a record aluminum ion beam current exceeding 58 mA at the Al11+ charge state, accelerated to an energy of 5.5 MeV using the direct plasma injection scheme, which integrates a laser ion source (LIS) with a radio frequency quadrupole (RFQ) accelerator. The effect of nozzle geometry on beam extraction was systematically investigated using 8 and 12 mm tapered designs and an 18 mm cylindrical configuration. The 18 mm nozzle achieved the highest Al11+ beam current, while the 12 mm aperture provided a favorable balance between beam intensity and current density. Beam extraction simulations confirmed effective RFQ matching across multiple charge states, and solenoidal field tuning further enhanced plasma collimation. This work not only establishes a new benchmark for high-current ion beam generation but also provides a fundamental understanding of plasma–beam interface dynamics crucial for the next generation of high-intensity particle accelerators, particularly those employing LIS-RFQ systems.


  • Open Access

    Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

    by Shota Ikeda, Shunsuke Ikeda, Takeshi Kanesue, Toshiro Sakabe, Antonino Cannavo, Masahiro Okamura, Kazumasa Takahashi, Chuan Zhang, Masashi Masuoka, Horana Gamage Madhawa

  • Open Access

    FLASH-therapy suitable single-pulse proton generation using TiH2 under nanosecond laser irradiation

    by Shotaro Matsui, Takeshi Kanesue, Shunsuke Ikeda, Toshiro Sakabe, Masahiro Okamura

    We investigated proton emission from titanium hydride (TiH2) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 109 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH2-based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

  • Open Access

    Benchmarking Monte Carlo codes for the modelling of low-energy neutron production target reactions

    by Sherryn MacLeod, Klaudiusz Jakubowski, James Vohradsky, Daniel R. Franklin, Toshiro Sakabe, Akram Hamato, Masahiro Okamura, Susanna Guatelli, Mitra Safavi-Naeini


  • Open Access

    Enhanced beam transport via space charge mitigation in a multistage accelerator for fusion plasma diagnostics

    by M. Nishiura, K. Nakamura, K. Ueda, A. Shimizu, H. Takubo, M. Kanda, T. Ido, M. Okamura

    Efficient transport of high-current negative ion beams is critical for accurate plasma potential diagnostics using heavy-ion beam probe (HIBP) systems in magnetically confined fusion plasmas. However, strong space-charge effects often degrade transport efficiency, particularly for heavy ions such as Au−. In this study, we demonstrate a substantial improvement in beam transport by introducing an electrostatic lens effect through optimized voltage allocation in a multistage acceleration system. Numerical simulations using IGUN, supported by experiments with the Large Helical Device-HIBP system, show that this approach effectively suppresses space-charge-induced beam divergence and loss. Without requiring mechanical modifications to the beamline, the optimized configuration enables a 2–3 fold increase in Au− beam current injected into the tandem accelerator. Consequently, plasma potential measurements were extended to higher-density plasmas, reaching line-averaged electron densities up to 1.75 × 10 19 m−3 with improved signal-to-noise ratio. This technique offers a compact, practical, and highly effective solution for transporting high-current heavy-ion beams under space-charge-dominated conditions. Beyond its impact on plasma diagnostics, the method is broadly applicable to a wide range of accelerator systems, including those used in scientific and industrial applications where high-intensity beam transport is required.