TKTakeshi Kanesue

Takeshi Kanesue

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takeshi Kanesue has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Bayesian optimization of the relativistic heavy ion collider luminosity via s * control

    by Xiaofeng Gu, Benjamin Coe, Guillaume Robert-Demolaize, Takeshi Kanesue, Masahiro Okamura, William Fung, Yue Hao, Ji Qiang, Xiaoye S. Li, Yang Liu

    In order to aid in luminosity maximization at the interaction point (IP), the collision location s IP must be equivalent to the location of the minimum value of the beta function s *. Accurate optics measurements and s * movements are therefore essential to luminosity optimization. However, according to current Relativistic Heavy Ion Collider (RHIC) operations measurements, average horizontal beta beat measurements between operating IPs are around 20% along with significant variation in s * measurements. Precise control of the longitudinal beam waist position ( s *) has become a critical yet challenging knob for maximizing the luminosity of modern high-energy colliders, particularly with short bunch lengths and high crossing angles. We present the online application of Bayesian optimization (BO) using the GPTune framework to systematically tune sPHENIX luminosity via s * control at the Relativistic Heavy Ion Collider (RHIC). The GPTune framework was first validated at the RHIC Electron Beam Ion Source (EBIS), where it delivered up to a 70% increase in beam intensity over the baseline, although experienced operators could also achieve this performance with longer manual tuning. The framework was then deployed during sPHENIX operations at RHIC. Using an intensity-normalized Zero-Degree-Calorimeter (ZDC) signal as the objective (owing to the unavailability of the live sPHENIX MVTX signal), GPTune successfully identified local luminosity maxima, recovered from intentionally degraded s * configurations, and uncovered residual horizontal and vertical waist offsets in the interaction region. These results demonstrate the robustness and efficiency of Bayesian optimization for real-time collider tuning under noisy and time-varying conditions. The developed methodology with s * control provides a powerful new tool for precision luminosity optimization and will be especially valuable for next-generation short-bunch colliders such as the Electron-Ion Collider (EIC).

  • Open Access

    Experimental Validation of PHITS-Predicted Neutron Moderation and Transport Driven by 1H(7Li,n)7Be Inverse-Kinematics Reaction

    by Toshiro Sakabe, Madhawa Horana Gamage, Yu Fujiwara, Shunsuke Ikeda, Takeshi Kanesue, Antonino Cannavo, Kazumasa Takahashi, Masahiro Okamura

    The inverse-kinematics 1H(7Li,n)7Be reaction provides forward-directed neutrons and is a promising candidate for accelerator-based boron neutron capture therapy (BNCT) neutron sources. Reliable moderator design for this neutron source requires experimental validation of Monte Carlo calculations. The present study aims to evaluate the predictive capability of PHITS for neutron moderation and transport toward future BNCT BSA design. In this study, a moderator assembly consisting of low-carbon steel, polyethylene, and graphite blocks was irradiated with neutrons produced by a 16.5 MeV 7Li3+ beam incident on a 12 μm-thick polypropylene target at the Tandem Van de Graff facility at Brookhaven National Laboratory. The neutron response downstream of the assembly was measured using a cylindrical BF3 neutron detector and compared with 10B(n,[[EQUATION]])7Li reaction rates calculated using PHITS Monte Carlo simulation. Cross-section data for the Inverse-kinematics reaction, generated from ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE, were separately applied to evaluate nuclear-data dependence. This study also investigates the effects of thermal neutron scattering law (TSL) data for polyethylene and graphite in the simulations. As a result, when TSL data were applied to polyethylene and graphite in the moderator assemblies, the calculated and measured reaction rates showed reasonable overall agreement, with C/E values ranging from 0.65 to 0.96 across all IK-Frag datasets. These results provide experimental support for the PHITS framework for predicting moderated neutrons and its application to future moderator and beam-shaping design for inverse-kinematics accelerator-based BNCT neutron sources.

  • Open Access

    Performance assessment of PHITS simulations for the inverse-kinematic p( 7 Li,n) 7 Be reaction based on fast-neutron measurements with a diamond detector

    by T. Sakabe, S. MacLeod, Y. Fujiwara, M. Horana Gamage, S. Ikeda, T. Kanesue, A. Cannavo, K. Takahashi, G. Ceccio, M. Okamura

    The inverse-kinematics p( 7 Li,n) 7 Be reaction produces forward-focused neutron emission, offering enhanced usable flux and reduced shielding requirements. Reliable simulation of such neutron fields is essential for the development of compact accelerator-based neutron sources. In this study, a PHITS-based simulation framework for the reaction was experimentally assessed using fast-neutron measurements. Forward-directed neutrons were measured with a diamond neutron detector and quantitatively compared with simulations with newly prepared IK-Frag cross-section file based on the proton-induced reaction data in ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE. Measurements and simulations were performed for incident 7 Li 3+ energies ranging from 15.0 to 25.0 MeV using a 50 μm-thick polypropylene target. For all conditions, the PHITS-based simulation framework reproduced the deposited energy spectra at the correct order of magnitude. The comparison of deposited energy spectra in the diamond detector showed high correlation coefficients across all investigated energies, indicating reasonable agreement in spectral shape between simulations and measurements. This work represents an initial step toward establishing a benchmark for PHITS simulations of the inverse kinematic reaction between an incident lithium-ion and a proton target.

  • Open Access

    Nozzle geometry optimization for high-current aluminum ion beam acceleration via direct plasma injection scheme

    by M. Horana Gamage, G. Garty, A. Cannavo, S. Ikeda, T. Kanesue, T. Sakabe, S. Kondrashev, M. Okamura, G. Ceccio, K. Takahashi

    We report the generation of a record aluminum ion beam current exceeding 58 mA at the Al11+ charge state, accelerated to an energy of 5.5 MeV using the direct plasma injection scheme, which integrates a laser ion source (LIS) with a radio frequency quadrupole (RFQ) accelerator. The effect of nozzle geometry on beam extraction was systematically investigated using 8 and 12 mm tapered designs and an 18 mm cylindrical configuration. The 18 mm nozzle achieved the highest Al11+ beam current, while the 12 mm aperture provided a favorable balance between beam intensity and current density. Beam extraction simulations confirmed effective RFQ matching across multiple charge states, and solenoidal field tuning further enhanced plasma collimation. This work not only establishes a new benchmark for high-current ion beam generation but also provides a fundamental understanding of plasma–beam interface dynamics crucial for the next generation of high-intensity particle accelerators, particularly those employing LIS-RFQ systems.


  • Open Access

    Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

    by Shota Ikeda, Shunsuke Ikeda, Takeshi Kanesue, Toshiro Sakabe, Antonino Cannavo, Masahiro Okamura, Kazumasa Takahashi, Chuan Zhang, Masashi Masuoka, Horana Gamage Madhawa

  • Open Access

    FLASH-therapy suitable single-pulse proton generation using TiH2 under nanosecond laser irradiation

    by Shotaro Matsui, Takeshi Kanesue, Shunsuke Ikeda, Toshiro Sakabe, Masahiro Okamura

    We investigated proton emission from titanium hydride (TiH2) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 109 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH2-based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

  • Open Access

    Demonstration of an intense lithium beam for forward-directed pulsed neutron generation

    by Masahiro Okamura, Shunsuke Ikeda, Takeshi Kanesue, Kazumasa Takahashi, Antonino Cannavó, Giovanni Ceccio, Anastasia Cassisa

    As an alternative to research nuclear reactors, a compact accelerator-driven neutron generator that uses a lithium beam driver could be a promising candidate since it produces almost no undesired radiation. However, providing an intense lithium-ion beam has been difficult, and it has been thought that the practical application of such a device would be impossible. The most critical problem of insufficient ion fluxes has been solved by applying a direct plasma injection scheme. In this scheme, a pulsed high-density plasma from a metallic lithium foil generated by laser ablation is efficiently injected and accelerated by a radio-frequency quadrupole linear accelerator (RFQ linac). We have obtained a peak beam current of 35 mA accelerated to 1.43 MeV, which is two orders of magnitude higher than a conventional injector and accelerator system can deliver.


  • Open Access

    Ion Generation Using Frozen Xenon Target for Laser Ion Source

    by Kazumasa Takahashi, Shunsuke Ikeda, Takeshi Kanesue, Masahiro Okamura

    A frozen laser target that is in the gaseous phase at room temperature is advantageous for a laser ion source because it can avoid the accumulation of damage from laser irradiation by regeneration of the target surface by additional gas freezing. In this study, the possibility of forming a xenon ion beam with a current sufficient for heavy-ion inertial fusion (HIF) was investigated. The relationship between the frozen target growth and resulting ion current was analyzed to determine the optimal condition of laser irradiation that ensures stable supply of ion beams for a long time. A frozen target of xenon was formed on a mount cooled to 20 K using a Gifford McMahon cryocooler, and plasma was generated using a Nd:YAG laser. The results showed that it is possible to supply a sufficient ion current for application of singly charged ions as a driver for HIF. Additionally, it was indicated that the xenon responsible for forming the plasma existed only at a certain depth from the target surface. The results imply that it is possible to obtain a stable ion supply for a long time by irradiating the target with a laser after the frozen xenon grows to a sufficient thickness.