Denison Souza-Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Denison Souza-Santos has a total of 224 co-authors. Here are the top co-authors by number of shared publications:
- Claudia Lucia de Pinho Mauricio
Instituto de Radioproteção e Dosimetria - IRD/CNEN
5 shared publications - Lina Quintieri
Laboratori Nazionali di Frascati dell'INFN, Italy
4 shared publications M. Begalli
State University of Rio de Janeiro - UERJ Brazil
4 shared publications- Paolo Saracco
INFN Sezione di Genova, Via Dodecaneso 33, I-16146 Genova, Italy
4 shared publications - Elisabetta Gargioni
Department of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
3 shared publications A Zoglauer
2 shared publications
Latest Publications
- Open Access
- 29 July 2026
- Published by Elsevier in SSRN Electronic Journal
The 2026ph Latin-American and Caribbean Regional Interlaboratory Comparison for External Radiation Monitoring: Methodological Aspects
In 2026, the The Latin-America and the Caribbean Occupational Radiation Protection Network (REPROLAM-Red de Optimización de Protección Radiológica Ocupacional en Latinoamérica y el Caribe) will conduct a new interlaboratory comparison exercise for external photon dosimetry in Latin America and the Caribbean. The exercise will evaluate the performance of individual monitoring services responsible for assessing occupational exposure using passive whole-body dosimeters for measuring the personal dose equivalent Hp(10) and Hp(0.07). Participating laboratories will submit dosimeters to be irradiated under at least eight blind conditions covering photon energies from 24 to 662 keV (at different qualities). The comparison exercise will incorporate methodological improvements compared with previous regional exercises, including a multilingual online management system, refined uncertainty analysis of beam parameters, and alignment with ISO 14146:2024 and ISO/IEC 17043 requirements. Reference doses are determined with a calibrated ionization chamber system and uncertainties are evaluated following the Guide to the Expression of Uncertainty in Measurement (GUM), resulting in expanded uncertainties of approximately 2.2-3.0% depending on beam quality. Acceptance criteria will be based on the ISO 14146:2024 performance limits. This work discusses these methodological improvements and their implications for the quality and reliability of the ongoing laboratories comparison exercise. This activity continues the REPROLAM initiatives aimed at strengthening regional technical capabilities, harmonizing dosimetric practices, and improving the reliability of occupational radiation monitoring services in Latin America and the Caribbean.
- 29 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThe 2026ph Latin-American and Caribbean Regional Interlaboratory Comparison for External Radiation Monitoring: Methodological Aspects
In 2026, the The Latin-America and the Caribbean Occupational Radiation Protection Network (REPROLAM-Red de Optimización de Protección Radiológica Ocupacional en Latinoamérica y el Caribe) will conduct a new interlaboratory comparison exercise for external photon dosimetry in Latin America and the Caribbean. The exercise will evaluate the performance of individual monitoring services responsible for assessing occupational exposure using passive whole-body dosimeters for measuring the personal dose equivalent Hp(10) and Hp(0.07). Participating laboratories will submit dosimeters to be irradiated under at least eight blind conditions covering photon energies from 24 to 662 keV (at different qualities). The comparison exercise will incorporate methodological improvements compared with previous regional exercises, including a multilingual online management system, refined uncertainty analysis of beam parameters, and alignment with ISO 14146:2024 and ISO/IEC 17043 requirements. Reference doses are determined with a calibrated ionization chamber system and uncertainties are evaluated following the Guide to the Expression of Uncertainty in Measurement (GUM), resulting in expanded uncertainties of approximately 2.2-3.0% depending on beam quality. Acceptance criteria will be based on the ISO 14146:2024 performance limits. This work discusses these methodological improvements and their implications for the quality and reliability of the ongoing laboratories comparison exercise. This activity continues the REPROLAM initiatives aimed at strengthening regional technical capabilities, harmonizing dosimetric practices, and improving the reliability of occupational radiation monitoring services in Latin America and the Caribbean.
- Open Access
- 17 July 2026
- Published by Elsevier in SSRN Electronic Journal
TDCR for Routine Measurements: Applicability Limits for ²¹⁰Pb and ⁹⁰Sr
The triple-to-double coincidence ratio (TDCR) method is widely used in liquid scintillation counting (LSC) due to its sensitivity to detection efficiency variations. While well established for pure β-emitting radionuclides under controlled conditions, its application to routine measurements involving time-dependent decay schemes remains insufficiently characterized. This study presents a systematic experimental investigation of applicability limits and correction strategies for TDCR using lead-210 (²¹⁰Pb) and strontium-90 (⁹⁰Sr) as case studies.Measurements were performed with a Hidex 300 SL system after chemical separation of parent radionuclides. The temporal evolution of TDCR values was analyzed in relation to daughter ingrowth and associated changes in the detected β-energy distribution. Direct TDCR-based activity determination was statistically consistent only within a limited time window after separation, corresponding to daughter contributions below approximately 20–22%.Beyond this interval, TDCR values increased under stable quench conditions, indicating sensitivity to spectral changes rather than quenching alone. The observed evolution followed Bateman predictions, supporting a physically grounded correction approach.After applying a Bateman-based correction, time-independent parent activities were obtained across the full measurement period, with z-scores within accepted limits. These results demonstrate that TDCR can provide reliable activity estimates under non-equilibrium conditions, particularly in routine or time-critical scenarios, while also defining practical limits for its application in time-dependent decay systems.
- 17 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTDCR for Routine Measurements: Applicability Limits for ²¹⁰Pb and ⁹⁰Sr
The triple-to-double coincidence ratio (TDCR) method is widely used in liquid scintillation counting (LSC) due to its sensitivity to detection efficiency variations. While well established for pure β-emitting radionuclides under controlled conditions, its application to routine measurements involving time-dependent decay schemes remains insufficiently characterized. This study presents a systematic experimental investigation of applicability limits and correction strategies for TDCR using lead-210 (²¹⁰Pb) and strontium-90 (⁹⁰Sr) as case studies.Measurements were performed with a Hidex 300 SL system after chemical separation of parent radionuclides. The temporal evolution of TDCR values was analyzed in relation to daughter ingrowth and associated changes in the detected β-energy distribution. Direct TDCR-based activity determination was statistically consistent only within a limited time window after separation, corresponding to daughter contributions below approximately 20–22%.Beyond this interval, TDCR values increased under stable quench conditions, indicating sensitivity to spectral changes rather than quenching alone. The observed evolution followed Bateman predictions, supporting a physically grounded correction approach.After applying a Bateman-based correction, time-independent parent activities were obtained across the full measurement period, with z-scores within accepted limits. These results demonstrate that TDCR can provide reliable activity estimates under non-equilibrium conditions, particularly in routine or time-critical scenarios, while also defining practical limits for its application in time-dependent decay systems.
- Open Access
- 6 February 2026
- Published by Elsevier in Radiation Measurements
- Vol. 193
A survey of dosimetry capabilities and trends in Latin America and the Caribbean region: Implications for occupational dosimetry
- 6 February 2026
- Published by Elsevier in Radiation Measurements
- Vol. 193
Open AccessA survey of dosimetry capabilities and trends in Latin America and the Caribbean region: Implications for occupational dosimetry
- Open Access
- 1 January 2022
- Published by Elsevier in Radiation Measurements
- Vol. 150
Monte Carlo calculation of organ and effective doses due to photon and neutron point sources and typical X-ray examinations: Results of an international intercomparison exercise
- 1 January 2022
- Published by Elsevier in Radiation Measurements
- Vol. 150
Open AccessMonte Carlo calculation of organ and effective doses due to photon and neutron point sources and typical X-ray examinations: Results of an international intercomparison exercise
- Open Access
- 8 August 2021
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 9 (2C)
Monte Carlo Characterization of an Individual Albedo Neutron Monitor
An individual albedo neutron dosimeter is simulated with the Geant4 toolkit. The simulation results are compared with results from an international intercomparison for Monte Carlo codes. The doses are obtained for thermoluminescent dosimeters irradiated free in the air and also on the surface of a water phantom for different neutron energy values. The Geant4 toolkit was not used by any of the participants in this intercomparison, so with these results we can infer the applicability of Geant4 in radiation protection for this type of simulation in neutron fields.
- 8 August 2021
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 9 (2C)
Open AccessMonte Carlo Characterization of an Individual Albedo Neutron Monitor
An individual albedo neutron dosimeter is simulated with the Geant4 toolkit. The simulation results are compared with results from an international intercomparison for Monte Carlo codes. The doses are obtained for thermoluminescent dosimeters irradiated free in the air and also on the surface of a water phantom for different neutron energy values. The Geant4 toolkit was not used by any of the participants in this intercomparison, so with these results we can infer the applicability of Geant4 in radiation protection for this type of simulation in neutron fields.
- 13 April 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 89-93
ALGORITHM BASED ON ARTIFICIAL BEE COLONY FOR UNFOLDING OF NEUTRON SPECTRA OBTAINED WITH BONNER SPHERES
Occupational neutron fields usually have energies from the thermal range to some MeV and the characterization of the spectra is essential for estimation of the radioprotection quantities. Thus, the spectrum must be unfolded based on a limited number of measurements. This study implemented an algorithm based on the bee colonies behavior, named Artificial Bee Colony (ABC), where the intelligent behavior of the bees in search of food is reproduced to perform the unfolding of neutron spectra. The experimental measurements used Bonner spheres and 6LiI (Eu) detector, with irradiations using a thermal neutron flux and three reference fields: 241Am–Be, 252Cf and 252Cf (D2O). The ABC obtained good estimation of the expected spectrum even without previous information and its results were closer to expected spectra than those obtained by the SPUNIT algorithm.
- 13 April 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 89-93
ALGORITHM BASED ON ARTIFICIAL BEE COLONY FOR UNFOLDING OF NEUTRON SPECTRA OBTAINED WITH BONNER SPHERES
Occupational neutron fields usually have energies from the thermal range to some MeV and the characterization of the spectra is essential for estimation of the radioprotection quantities. Thus, the spectrum must be unfolded based on a limited number of measurements. This study implemented an algorithm based on the bee colonies behavior, named Artificial Bee Colony (ABC), where the intelligent behavior of the bees in search of food is reproduced to perform the unfolding of neutron spectra. The experimental measurements used Bonner spheres and 6LiI (Eu) detector, with irradiations using a thermal neutron flux and three reference fields: 241Am–Be, 252Cf and 252Cf (D2O). The ABC obtained good estimation of the expected spectrum even without previous information and its results were closer to expected spectra than those obtained by the SPUNIT algorithm.
- 14 December 2017
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 395-398
DETERMINATION OF NEUTRON EFFECTIVE DOSES IN WHOLE BODY POINT SOURCE EXPOSURES
The objective of this work is to obtain fluence to effective dose conversion coefficients for neutron point sources, using the GEANT4 toolkit. These calculations aim to investigate the aspects of neutron transport in the human body through Monte Carlo simulation using the International Commission on Radiological Protection (ICRP) voxel phantoms, described in its publication 110. A benchmarking of the code was made for the case of monoenergetic plane parallel neutron beam in the antero-posterior (AP) irradiation geometry and organ absorbed dose conversion coefficients were compared with those found in the ICRP publication 116. The results showed good agreement with ICRP results in the studied energy range. Conversion coefficients were presented for specific conditions with 241Am–Be and 252Cf point neutron sources 1 m away from the phantom in the AP geometry.
- 14 December 2017
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 395-398
DETERMINATION OF NEUTRON EFFECTIVE DOSES IN WHOLE BODY POINT SOURCE EXPOSURES
The objective of this work is to obtain fluence to effective dose conversion coefficients for neutron point sources, using the GEANT4 toolkit. These calculations aim to investigate the aspects of neutron transport in the human body through Monte Carlo simulation using the International Commission on Radiological Protection (ICRP) voxel phantoms, described in its publication 110. A benchmarking of the code was made for the case of monoenergetic plane parallel neutron beam in the antero-posterior (AP) irradiation geometry and organ absorbed dose conversion coefficients were compared with those found in the ICRP publication 116. The results showed good agreement with ICRP results in the studied energy range. Conversion coefficients were presented for specific conditions with 241Am–Be and 252Cf point neutron sources 1 m away from the phantom in the AP geometry.
- Open Access
- 19 October 2017
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 5 (3)
Simulação de uma gama-câmara para medidas de atividade de 99mTc com o código monte carlo gate
Simulação de uma gama-câmara para medidas de atividade de 99mTc com o código monte carlo gate
- 19 October 2017
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 5 (3)
Open AccessSimulação de uma gama-câmara para medidas de atividade de 99mTc com o código monte carlo gate
Simulação de uma gama-câmara para medidas de atividade de 99mTc com o código monte carlo gate
- 1 October 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 139, 179-183
Comparison of the neutron ambient dose equivalent and ambient absorbed dose calculations with different GEANT4 physics lists
- 1 October 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 139, 179-183
Comparison of the neutron ambient dose equivalent and ambient absorbed dose calculations with different GEANT4 physics lists
- 1 June 2017
- Published by Elsevier in Radiation Measurements
- Vol. 101, 13-21
The HMGU combined neutron and photon dosemeter
- 1 June 2017
- Published by Elsevier in Radiation Measurements
- Vol. 101, 13-21
The HMGU combined neutron and photon dosemeter