Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mauro Malvè has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Additive Manufacturing of Bioresorbable Tracheal Stents from PDO/PCL Blends: Effects of Composition and Processing on Structure and Properties

    by Carmen Sánchez González, Mauro Malvè, Cristina Díaz Jiménez

    Fused deposition modeling (FDM) is an additive manufacturing (AM) technology that enables the fabrication of complex and patient-specific devices made of biodegradable polymers. The successful implementation of the process requires exhaustive control of the workflow, focusing on material selection, device design, and manufacturing parameters. The aim of this study is to evaluate and compare the printability, processability, and mechanical performance of a polymer blend for the fabrication of customized airway stents using FDM printing, with a focus on its potential industrial scalability. Two FDM manufacturing approaches were evaluated using standard geometries to manufacture a blend of biodegradable polymers, using either filaments or pellets as feedstock. Moreover, the suitability of a blend made of polycaprolactone (PCL) and polydioxanone (PDO) for manufacturing tracheal stents was studied in comparison to their pure forms. Regarding the manufacturing technology, the feeding method itself was not the primary factor affecting the mechanical properties of the printed components, which was directly related to the geometry of the device and the cooling time polymers required. Furthermore, although the PCL/PDO blend showed a slightly higher mean elastic modulus than pure PCL, the resulting material did not exhibit sufficient radial resistance for airway stent applications. The design and development of 3D-printed medical devices require an evaluation of the entire manufacturing workflow. Device geometry and material selection are strongly influenced by the manufacturing technology selected and have a direct impact on the mechanical performance of the final product.

  • Open Access

    Patient-Specific Computational Fluid Dynamics of Pulmonary Arterial Hemodynamics in Dogs with and Without Pulmonic Stenosis

    by Carla Zamora-Perarnau, Mauro Malvè, Patricia Sebastián-Marcos, Rocío Fernández-Parra

    Pulmonic stenosis (PS) is one of the most common congenital cardiac diseases in dogs. Although echocardiography and computed tomographic angiography (CTA) provide valuable diagnostic and anatomical information, the hemodynamic consequences of PS remain incompletely characterized. This study describes patient-specific pulmonary artery hemodynamics in dogs with and without PS using computational fluid dynamics (CFD). Contrast-enhanced CTA and echocardiographic data from five dogs with PS and five control dogs without PS were used to reconstruct three-dimensional pulmonary artery geometries and generate patient-specific CFD models. Pressure drop (Δp), blood flow velocity, mean wall shear stress (WSS), time-averaged WSS (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and pulmonary artery resistance were quantified and compared between groups. Dogs with PS exhibited markedly increased transvalvular pressure gradients, peak flow velocities, and pulmonary artery resistance, together with high-velocity jets and localized post-stenotic recirculation that were absent in control dogs. Mean WSS and TAWSS tended to be higher in the PS group, whereas OSI values were similar between groups. In contrast, RRT was significantly lower (p = 0.032) in dogs with PS. These findings demonstrate that patient-specific CFD enables detailed characterization of pulmonary artery hemodynamics in canine PS, providing information that complements conventional imaging. Although its clinical utility in veterinary medicine has yet to be fully established, CFD can provide valuable insight into flow behavior and disease pathophysiology; however, its ability to yield precise, clinically applicable quantitative values remains limited. This approach shows promise for future applications in the clinical evaluation of PS and other cardiovascular diseases, although further studies are warranted to determine its clinical relevance in veterinary medicine.

  • Open Access

    A Computational Framework for the Design and Mechanical Assessment of Biodegradable Airway Stents: Interaction with Rabbit Tracheal Tissue and Preliminary In Vivo Observations

    by Ada Ayechu-Abendaño, Letizia Cella, Carmen Sánchez-González, Carmen Sánchez-Matás, José Luis López-Villalobos, Cristina Díaz-Jiménez, Rocío Fernández-Parra, Mauro Malvè

    Current airway stents, including silicone and metallic devices, remain associated with important complications such as migration, restenosis, mucus retention and the need for repeated interventions. Biodegradable stents offer a promising alternative by providing temporary mechanical support while avoiding the long-term presence of a permanent implant. However, the influence of stent geometry and material properties on their mechanical performance and interaction with airway tissue is still not fully understood. This study presents a computational framework integrating computer-aided design and finite element analysis to investigate the mechanical behaviour of biodegradable tracheobronchial stents. Two stent architectures (X-pattern and W-pattern) were analysed over a range of wire thicknesses using two biodegradable materials: a PLA/PCL; 70/30 wt.% blend and AZ31 magnesium alloy. Radial compression, diameter recovery after radial compression and stent–tissue interaction simulations were performed to evaluate the influence of geometry, material selection and design parameters on device performance. The results suggested that both stent geometry and material properties strongly influence the mechanical behaviour of biodegradable airway stents, although they affect different aspects of the stent–tissue interaction. The X-pattern consistently exhibited greater resistance to radial compression, lower elastic diameter recovery after radial compression and improved maintenance of the expanded lumen compared with the W-pattern. Material properties primarily affected the magnitude of the mechanical response, as further confirmed by the quantitative contact-pressure analysis, with AZ31 providing greater radial support, while the spatial distributions of stress and strain within the tracheal wall were mainly governed by the stent architecture. Based on the computational analyses, X-pattern stents manufactured from the PLA/PCL; 70/30 wt.% blend were selected for in vivo evaluation in a rabbit model. Endoscopic observations revealed tissue features that were qualitatively consistent with the mechanical patterns predicted by the numerical simulations, although no direct causal relationship can be established from the available observations. These findings support the ability of the proposed framework to represent the principal aspects of stent–tissue interaction. The proposed computational framework provides a practical tool for the rational design and mechanical assessment of biodegradable airway stents and may facilitate the future development of customised airway prostheses.


  • Open Access

    Drug delivery, deposition and transport in stenosed and stented human tracheas

    by Mauro Malvè, Carmen Sánchez-Matás, José Luis López-Villalobos, Rocío Fernández-Parra

  • Open Access

    Editorial: Evolution in cardiovascular MedTech

    by Mauro Malvè, Rosaire Mongrain, Stephane Avril

    The first set of articles, published in Frontiers in Medical Technology, addresses both computational and experimental frameworks that seek to improve risk assessment, device design, and mechanistic understanding in cardiovascular interventions. Astori et al. open the topic with a study that tackles a critical clinical problem in congenital and pediatric care: risk assessment of coronary artery compression in pulmonary conduit pre stenting. By employing finite element analysis, the authors explore the interplay between modelling complexity, computational expense, and predictive reliability. Their work highlights how patient specific simulations can support procedural planning by balancing accuracy with practical resource constraints -a theme that resonates across many domains of cardiovascular technology, where personalised risk assessment is becoming increasingly important.Building on the theme of diagnostic innovation, He et al. investigate the utility of magnetocardiography (MCG) as a non-invasive tool for functional assessment of myocardial ischemia in patients with stable coronary artery disease. Through rigorous validation against established standards, this study shows that MCG may offer additional functional insight beyond conventional electrocardiography, particularly in subtle cases of ischemic burden. Such advances in non-invasive functional assessment underscore the growing role of novel sensing modalities in cardiovascular diagnostics, particularly when combined with sophisticated signal processing.In the domain of interventional cardiology, Renon et al. explore how computational modelling can inform the evolving practice of percutaneous coronary intervention with drug coated balloons. Through detailed simulations, the authors illustrate how computational fluid dynamics and structural modelling can provide mechanistic insight into dose distribution, drug transport, and vessel wall response -factors that are difficult to resolve empirically. Importantly, this work reinforces the notion that computational tools are not merely research artefacts but have genuine translational potential to inform device selection, procedural strategy, and optimisation of therapies.Device design extends beyond simulation alone. Kortman et al. contribute a comprehensive patent review of advancements in aspiration catheter tip design for thrombectomy. By tracking innovation through patent literature, the authors identify key design trends -such as improvements in tip geometry, material selection, and flow steering -that have the potential to influence procedural success and patient outcomes. This sweeping review bridges clinical need and engineering creativity, illustrating how intellectual property trends can provide a leading indicator of future practice.Experimentation remains crucial for device evaluation. Vellaparambil et al. present an experimental validation of auxetic stent designs using three point bending tests on 3D printed titanium prototypes. Auxetic structures, which exhibit a negative Poisson's ratio, have emerged as promising candidates for cardiovascular scaffolds, offering enhanced conformability and mechanical performance. By combining additive manufacturing with mechanical testing, this study lays the groundwork for future optimisation of stent mechanics -particularly in anatomically challenging locations such as bifurcations or tortuous vessels. Vento et al. offer a broader vantage point in their perspective article on evolutionary trends and innovations in cardiovascular intervention. By synthesising historical developments and future directions, they articulate how incremental improvements and paradigm shifts alike have shaped contemporary practices. Their analysis contextualises the other contributions in this volume, reminding readers that evolution in medical technology is iterative and multidimensional, spanning materials science, computational modelling, imaging, and procedural innovation.The final two articles of this Research Topic, published in Frontiers in Cardiovascular Medicine, bridge the technological insights of Medical Technology with clinical outcomes and practical implications. Mochizuki et al. present a case report on the use of belt electrode skeletal muscle electrical stimulation for acute heart failure in a patient with severe obesity. This innovative application highlights how bioelectronic stimulation can serve as a therapeutic option in acute phases and suggests new avenues for rehabilitation strategies, particularly in populations where conventional exercise therapy is limited.Rounding out the collection, Tu et al. provide valuable long term comparative data on two stenting strategies for true coronary bifurcation lesions: Double Kissing Mini culotte versus Mini culotte stenting using drug eluting stents. With five-year clinical outcomes, this study contributes much needed evidence on procedural durability, restenosis rates, and adverse event profilesoutcomes that are critically relevant to interventional cardiologists and device developers alike. By anchoring device design and procedural planning in extended clinical follow up, this work exemplifies the type of translational research that connects engineering innovation with real world patient benefit.Taken together, the articles in Evolution in Cardiovascular MedTech reflect the current state of an interdisciplinary field that is advancing through synergy between engineering and clinical science. Computational models are increasingly used not only for hypothesis generation but also for personalised risk identification; experimental prototypes are being validated with modern manufacturing techniques; and long-term clinical evidence is being systematically integrated with device and procedural innovation.As the pace of progress accelerates, several cross-cutting themes emerge from this volume. First, the importance of personalisation -whether through patient specific simulations, tailored device...

  • Open Access

    Editorial: Animal biomechanics: application of biomedical engineering to veterinary sciences for animal healthcare, volume II

    by Mauro Malvè, Rocío Fernández-Parra

    Within the field of experimental and clinical biomechanics, Shin et al. present a finite element analysis to evaluate the biomechanical performance of different plate placements in canine elbow arthrodesis. Specifically, caudal, medial, and lateral plate configurations are compared in terms of stress distribution and create stability. Their results indicate that plate position has a substantial influence on load transfer and mechanical behaviour of the arthrodesis construct, highlighting the relevance of computational modelling for optimizing surgical planning and implant positioning in veterinary orthopaedics. Casas-Alvarado et al. investigate the surface thermal response of peripheral nerve blocks in dogs undergoing trauma or orthopaedic surgery, shedding light on analgesic monitoring under clinical conditions. Underberg et al. use time-of-flight magnetic resonance imaging to achieve non-contrast enhanced visualization of equine foot vasculature in a cadaver model, demonstrating a promising imaging approach. Day et al. compare polyethylene cable versus stainless steel cerclage wire in a canine fracture model, providing biomechanical insight relevant to orthopaedic repair. Wang et al. contribute two complementary studies on large avian species, reporting on head and neck movement characteristics and on morphological parameters of vertebrae in domestic geese and ducks, respectively, with implications for comparative anatomy, motion analysis, and veterinary ergonomics. Guevar et al. present a comparative biomechanical analysis of monocortical and bicortical polyaxial screw-rod fixation strategies in canine lumbar stabilization, and Kim et al. describe a modified laparoscopic-assisted percutaneous gastropexy technique in dogs, exemplifying surgical innovation and minimally invasive approaches. This volume also presents advancements in personalized veterinary devices and computational approaches. Sutter et al. present a cadaveric study of patient-specific 3D-printed nasopharyngeal stents in dogs, highlighting the potential of additive manufacturing for customized veterinary implants. Yu et al. apply deep learning to ultrasonographic data to classify canine chronic kidney disease, illustrating the promise of artificial intelligence in diagnostic workflows. Huart et al. employ statistical shape modelling to characterize the geometric morphology of the canine femur, tibia, and patella, offering quantitative reference data that may support clinical decision-making, implant design, and surgical planning. These studies collectively demonstrate how computational modelling, machine learning, and additive manufacturing converge to enable more precise, individualized, and effective interventions in veterinary practice. Taken together, the articles in Volume II illustrate the range and depth of how biomedical engineering is being applied across veterinary disciplines. From imaging and implant design to computational diagnostics, motion analysis, and educational technologies, this collection demonstrates both technological diversity and translational relevance. At the same time, the volume underscores that many questions remain open -particularly those that lie at the intersection of quantitative model validation, clinical implementation, and species-specific biomechanics. The findings presented here also highlight the need for interdisciplinary collaboration, integrating veterinary clinicians, biomedical engineers, computer scientists, and data analysts to address complex health challenges.We thank all the authors for their contributions to this Research Topic. We hope that this collection not only enriches the field of veterinary biomechanics but also promotes further collaboration between veterinary clinicians and engineers. By promoting such interdisciplinary partnerships, this research strongly aligns with the OneHealth framework, which recognizes the interconnection of human, animal, and environmental health. Knowledge and methodologies developed in human biomechanics can, in turn, be applied to animals, improving veterinary care and outcomes. The insights gained from these studies can inform better clinical interventions, enhance animal welfare, and generate findings that may translate back to human health.

  • Open Access

    Application of the Time-Averaged Entropy Generation Rate (TAEGR) to Transient Hemodynamic Analysis of the Human Aorta Using CFD–FSI

    by Jesús Alberto Crespo-Quintanilla, Jorge Arturo Alfaro-Ayala, José de Jesús Ramírez-Minguela, Agustín Vidal-Lesso, David Aarón Rodríguez-Alejandro, Oscar Alejandro López-Núñez, Mauro Malvé, Miguel Ángel Martínez Barca

    This work focuses on the development of a patient-specific transient CFD–FSI numerical model combined with the Time-Averaged Entropy Generation Rate (TAEGR) to predict hemodynamic parameters in the thoracic aorta, including the Oscillatory Shear Index (OSI) and the Time-Averaged Wall Shear Stress (TAWSS). While arterial blood flow can be modeled assuming either rigid or elastic arterial walls, the effect of wall compliance on these parameters, particularly on TAEGR, remains insufficiently characterized. Moreover, the interpretation of established indicators is not unique, as regions of vascular relevance may correspond to either high or low values of OSI and TAWSS. The proposed approach aims to identify symmetry and asymmetry in shear stress and entropy generation within the arterial wall, which are closely associated with the development of atherosclerotic plaque. Four aortas from clinical patients were analyzed using the proposed numerical framework to investigate blood flow behavior. The results revealed regions with high values of the hemodynamic parameters (OSI > 0.15, TAWSS ≥ 2 Pa, and TAEGR ≥ 20 W/m3K) predominantly located in the vicinity of the upper arterial branches. These regions, referred to as critical zones, are considered prone to the development of cardiovascular diseases, particularly atherosclerosis. The proposed numerical model provides a reliable qualitative framework for assessing symmetry and asymmetry in aortic blood flow patterns under different surgical conditions.

  • Open Access

    Influence of Material Selection on the Mechanical Properties of 3D-Printed Tracheal Stents for Surgical Applications

    by Aurora Pérez Jiménez, Carmen Sánchez González, Sandra Pérez Teresí, Noelia Landa, Cristina Díaz Jiménez, Mauro Malvé

    Endotracheal prosthesis placement is employed as a therapeutic intervention for tracheal lesions in cases where conventional surgical approaches are not feasible. The learning curve for endotracheal stent placement can vary depending on the type of stent, the training environment, and the clinician’s prior experience; however, it is generally considered moderately complex. Inadequate practice can have serious consequences, as the procedure involves a critical area such as the airway. The main risks and complications associated with inadequate technique or improper execution can include stent migration, formation of granulation tissue or hyperplasia, tracheal or pulmonary infection, obstruction or fracture of the stent, hemorrhage and tracheal perforation, among others. The purpose of the present study is to summarize important information and evaluate the role of different material features in the 3D printing manufacturing of an appropriate tracheobronchial medical device, which should be as appropriate as possible to facilitate placement during surgical practice. A complex stent design was fabricated using three different biodegradable materials, polycaprolactone (PCL), polydioxanone (PDO), and polymer blend of polylactic acid/polycaprolactone (PLA/PCL), through additive manufacturing, specifically fused filament fabrication (FFF)3D printing. Parameter optimization of the 3D printing process was required for each material to achieve an adequate geometric quality of the stent. Experimental analyses were conducted to characterize the mechanical properties of the printed stents. Flexural strength and radial compression resistance were evaluated, with particular emphasis on radial force due to its clinical relevance in preventing collapse after implantation in the trachea. The results provide valuable insights into how material selection could influence device behavior during placement to support surgical requirements.


  • Open Access

    Effect of Annealing on the Mechanical Properties of Composites of PLA Mixed with Mg and with HA

    by Carmen Sánchez González, Aurora Pérez Jiménez, Mauro Malvé, Cristina Díaz Jiménez

    Polylactic acid (PLA) is a bioresorbable and biocompatible material and is a promising alternative to the current materials used for permanent implants as it has osteosynthesis properties. However, this material has some drawbacks due to its low mechanical and thermal resistance after 3D printing. Extensive research has been conducted to improve the properties of this material, for example, with the addition of other compounds, such as magnesium (Mg) or Hydroxyapatite (HA). These reinforced materials have been shown to reduce the internal stress of the matrix of PLA, improving the thermal, optical and structural properties of the material, even though the performance achieved is lower than needed to be implanted. In addition, although it is known that the addition of Mg or HA affects the mechanical performance of the material, mechanical properties have not been studied in the literature. Thus, the aim of this study is to research the effect of thermal post-processing based on annealing of composites made of PLA with Mg and PLA with HA, manufactured by fused filament fabrication, with the goal of finding an improvement in the mechanical properties of these materials. As a result, different designs of annealing processes have been studied with different reinforced materials and their mechanical properties have been compared, studying axial traction and compression, radial compression as well as flexibility, among others. The comparative results achieved show the relevance of the design of the annealing process for the improvement of the mechanical properties of these materials.


  • Open Access

    Impact of geometric and hemodynamic changes on a mechanobiological model of atherosclerosis

    by Patricia Hernández-López, Myriam Cilla, Miguel A. Martínez, Estefanía Peña, Mauro Malvè