U. Clemens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
U. Clemens has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
G. Kemmerling
Forschungszentrum Jülich GmbH, Zentralinstitut für Elektronik, 52425 Jülich, Germany
8 shared publicationsJ. Schelten
Forschungszentrum Jülich GmbH, Zentralinstitut für Elektronik, 52425 Jülich, Germany
6 shared publicationsR. Engels
6 shared publicationsK. Zwoll
Forschungszentrum Julich, Germany
5 shared publications- Heinz Rongen
Central Institute of Engineering, Electronics, and AnalyticsElectronic Systems (ZEA-2), Forschungszentrum, Jülich, Germany
4 shared publications M. Heiderich
Forschungszentrum Jülich GmbH, Institut für Festkörperphysik, JCNS, D-52425, Germany
3 shared publications
Latest Publications
- 1 June 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 604 (1-2) , 147-149
Position-sensitive detectors of the detector group at Jülich
- 1 June 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 604 (1-2) , 147-149
Position-sensitive detectors of the detector group at Jülich
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 1206-1208
Upgrade of position sensitive detector system for small angle neutron scattering
At the small angle neutron scattering instrument KWS2 of the new research reactor FRM II at Munich an upgrade of the detector system is currently under development. In order to improve the count rate capability, the readout electronics of the large scintillation detector is to be replaced by a modern state-of-the-art electronics, which implements a shorter pulse processing and higher bandwidth for transport of the data. An overall dead time of 1 μs is aimed at with the new design. First measurements with the new readout-electronics have been carried out, showing a considerable increase of the count rate capability.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 1206-1208
Upgrade of position sensitive detector system for small angle neutron scattering
At the small angle neutron scattering instrument KWS2 of the new research reactor FRM II at Munich an upgrade of the detector system is currently under development. In order to improve the count rate capability, the readout electronics of the large scintillation detector is to be replaced by a modern state-of-the-art electronics, which implements a shorter pulse processing and higher bandwidth for transport of the data. An overall dead time of 1 μs is aimed at with the new design. First measurements with the new readout-electronics have been carried out, showing a considerable increase of the count rate capability.
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3 pp.-428
New synchronisation system for experiments at COSY
To improve existing experiments at COSY a new DAQ system is currently under development. It is also well suited to the requirements of WASA at COSY after its transfer from CELSIUS. The DAQ modules are scattered to about 10..20 crates and are able to digitize and store several thousands events before a computer engagement is required. Therefore we need a purely hardware based synchronisation system. The synchronisation system consists of one master module and several output modules housed in a proprietary LVDS crate. It communicates over point to point links with the crate controllers
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3 pp.-428
New synchronisation system for experiments at COSY
To improve existing experiments at COSY a new DAQ system is currently under development. It is also well suited to the requirements of WASA at COSY after its transfer from CELSIUS. The DAQ modules are scattered to about 10..20 crates and are able to digitize and store several thousands events before a computer engagement is required. Therefore we need a purely hardware based synchronisation system. The synchronisation system consists of one master module and several output modules housed in a proprietary LVDS crate. It communicates over point to point links with the crate controllers
- 18 October 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 51 (5) , 2131-2134
Neutron detection experiments with ionization counter and /sup 6/Li converter
The detection of neutrons with thin /sup 6/Li containing films or layers within an ionization chamber is discussed. A detection efficiency of 50% for thermal neutrons is obtainable with three 100-/spl mu/m thin /sup 6/Li foils. Preliminary measurements were performed with converters which contain a 1-/spl mu/m thin /sup 6/LiF layer. The detector efficiency is only 3%. Pulse height distributions were measured and analyzed for the gases Ar, CF/sub 4/, and C/sub 2/F/sub 6/ at pressures between 0.5 and 5 atm and at voltages between 50 and 500 V. Diffraction peaks from polycrystalline iron and semi-crystalline pyrolytic graphite were measured in TOF mode and are presented.
- 18 October 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 51 (5) , 2131-2134
Neutron detection experiments with ionization counter and /sup 6/Li converter
The detection of neutrons with thin /sup 6/Li containing films or layers within an ionization chamber is discussed. A detection efficiency of 50% for thermal neutrons is obtainable with three 100-/spl mu/m thin /sup 6/Li foils. Preliminary measurements were performed with converters which contain a 1-/spl mu/m thin /sup 6/LiF layer. The detector efficiency is only 3%. Pulse height distributions were measured and analyzed for the gases Ar, CF/sub 4/, and C/sub 2/F/sub 6/ at pressures between 0.5 and 5 atm and at voltages between 50 and 500 V. Diffraction peaks from polycrystalline iron and semi-crystalline pyrolytic graphite were measured in TOF mode and are presented.
- 19 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 51 (3) , 1098-1102
Performance measurements of a new large-area neutron scintillation detector system
During the upgrade of the small-angle neutron scattering instrument KWS-1 at the research reactor FRJ-2, the 15-yr-old detector system has been replaced. While the Anger camera-based concept of the detector remained unchanged, the signal and data processing branch has been completely revised. Because of higher count rate requirements, a highly configurable parallel readout electronics has been developed aiming at counting rates of several hundred kilohertz. The whole detector system has been recently installed at KWS-1 and measurements to study the system performance have been carried out. The linearity and spatial resolution of the new detector have been determined by an analysis of an acquired image taken with a hole diaphragm in front of the scintillator. The overall system dead time has been measured by comparing the detector count rates at several scattering intensities to the count rates achieved with a fission chamber. Finally, scattering patterns of well-known samples have been taken in order to demonstrate the quality of the acquired images.
- 19 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 51 (3) , 1098-1102
Performance measurements of a new large-area neutron scintillation detector system
During the upgrade of the small-angle neutron scattering instrument KWS-1 at the research reactor FRJ-2, the 15-yr-old detector system has been replaced. While the Anger camera-based concept of the detector remained unchanged, the signal and data processing branch has been completely revised. Because of higher count rate requirements, a highly configurable parallel readout electronics has been developed aiming at counting rates of several hundred kilohertz. The whole detector system has been recently installed at KWS-1 and measurements to study the system performance have been carried out. The linearity and spatial resolution of the new detector have been determined by an analysis of an acquired image taken with a hole diaphragm in front of the scintillator. The overall system dead time has been measured by comparing the detector count rates at several scattering intensities to the count rates achieved with a fission chamber. Finally, scattering patterns of well-known samples have been taken in order to demonstrate the quality of the acquired images.
- 20 November 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 212-214
A system for multiplexed chip readout of double-sided silicon detectors
For the ANKE spectrometer at the Cooler Synchrotron COSY-Julich, a vertex detector is under development. Double-sided structured silicon-strip detectors with a thickness from 65 /spl mu/m to 5500 /spl mu/m are used in a telescope-like structure. They allow the /spl Delta/E/E-identification of low energy spectator protons and therefore the use of deuterium as an effective neutron target. As frontend chip the VA32TA2 has been selected. They are connected to both sides of the detector. Because half of them, together with their readout electronics, needs to be operated at the bias voltage of the detectors (10-1000 V), a special system for multiplexed chip readout has been developed. It provides two ADCs per detector, one per each side, and allows for the configuration of all analog voltages by DACs and control timings by programmable sequence generators.
- 20 November 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 212-214
A system for multiplexed chip readout of double-sided silicon detectors
For the ANKE spectrometer at the Cooler Synchrotron COSY-Julich, a vertex detector is under development. Double-sided structured silicon-strip detectors with a thickness from 65 /spl mu/m to 5500 /spl mu/m are used in a telescope-like structure. They allow the /spl Delta/E/E-identification of low energy spectator protons and therefore the use of deuterium as an effective neutron target. As frontend chip the VA32TA2 has been selected. They are connected to both sides of the detector. Because half of them, together with their readout electronics, needs to be operated at the bias voltage of the detectors (10-1000 V), a special system for multiplexed chip readout has been developed. It provides two ADCs per detector, one per each side, and allows for the configuration of all analog voltages by DACs and control timings by programmable sequence generators.
- 1 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 656-659 Vol.1
Neutron detection experiments with ionisation counter and /sup 6/Li converter
The detection of neutrons with thin /sup 6/Li containing films or layers within an ionisation chamber is discussed. A detection efficiency of 50% for thermal neutrons is obtainable with three 100/spl mu/m thin /sup 6/Li foils. Preliminary measurements were performed with converters which contain a 1/spl mu/m thin /sup 6/LiF layer. The detector efficiency is only 3%. Pulse height distributions were measured and analysed for the gases Ar, CF/sub 4/ and C/sub 2/F/sub 6/ at pressures between 0.5 atm and 5 atm and at voltages between 50V and 500V. Diffraction peaks from polycrystalline iron and semi-crystalline pyrolytic graphite were measured in TOF mode and are presented.
- 1 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 656-659 Vol.1
Neutron detection experiments with ionisation counter and /sup 6/Li converter
The detection of neutrons with thin /sup 6/Li containing films or layers within an ionisation chamber is discussed. A detection efficiency of 50% for thermal neutrons is obtainable with three 100/spl mu/m thin /sup 6/Li foils. Preliminary measurements were performed with converters which contain a 1/spl mu/m thin /sup 6/LiF layer. The detector efficiency is only 3%. Pulse height distributions were measured and analysed for the gases Ar, CF/sub 4/ and C/sub 2/F/sub 6/ at pressures between 0.5 atm and 5 atm and at voltages between 50V and 500V. Diffraction peaks from polycrystalline iron and semi-crystalline pyrolytic graphite were measured in TOF mode and are presented.
- 1 August 2001
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 48 (4) , 1114-1117
A new two-dimensional scintillation detector system for small-angle neutron scattering experiments
A new two-dimensional position-sensitive detector system for small-angle neutron scattering experiments is under development. It is based on a 60/spl times/60 cm/sup 2/ large /sup 6/Li-glass scintillator for the neutron capture and dispersion of the emitted light on an array of photomultiplier tubes for the derivation of the event position. For subthermal neutrons of 8 /spl Aring/, an efficiency of 96% and a spatial resolution of 8 mm are to be achieved. Major improvements have been made in the signal- and data-processing branch, which aims at an electronic dead time of 1 /spl mu/s. A fast digitalization method using free-running analog-to-digital converters for each photomultiplier combined with field-programmable gate arrays for a parallel event detection in all channels has been applied. A subsequent farm of up to 16 floating-point digital signal processors is used to provide enough computing power for an improved reconstruction of the event position according to a maximum likelihood method.
- 1 August 2001
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 48 (4) , 1114-1117
A new two-dimensional scintillation detector system for small-angle neutron scattering experiments
A new two-dimensional position-sensitive detector system for small-angle neutron scattering experiments is under development. It is based on a 60/spl times/60 cm/sup 2/ large /sup 6/Li-glass scintillator for the neutron capture and dispersion of the emitted light on an array of photomultiplier tubes for the derivation of the event position. For subthermal neutrons of 8 /spl Aring/, an efficiency of 96% and a spatial resolution of 8 mm are to be achieved. Major improvements have been made in the signal- and data-processing branch, which aims at an electronic dead time of 1 /spl mu/s. A fast digitalization method using free-running analog-to-digital converters for each photomultiplier combined with field-programmable gate arrays for a parallel event detection in all channels has been applied. A subsequent farm of up to 16 floating-point digital signal processors is used to provide enough computing power for an improved reconstruction of the event position according to a maximum likelihood method.
- 1 January 2000
- Published by Springer Nature
- p. 20-23
Magnetocardiograms Recorded by First-Order Gradiometers Using HTS rf SQUIDs
- 1 January 2000
- Published by Springer Nature
- p. 20-23
Magnetocardiograms Recorded by First-Order Gradiometers Using HTS rf SQUIDs
- 1 December 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 46 (6) , 1995-1997
A compact and flexible CCD readout-system
- 1 December 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 46 (6) , 1995-1997
A compact and flexible CCD readout-system