Heinz Rongen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Heinz Rongen has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
- Martin Kaufmann
Institute of Climate and Energy Systems - Stratosphere (ICE-4), Forschungszentrum Jülich, Jülich, Germany
7 shared publications - Tom Neubert
Institute of Technology and Engineering (ITE), Forschungszentrum Jülich, Jülich, Germany
7 shared publications - Martin Riese
Institute of Climate and Energy Systems - Stratosphere (ICE-4), Forschungszentrum Jülich, Jülich, Germany
5 shared publications - U. Clemens
Forschungszentrum Jülich GmbH, Zentralinstitut für Elektronik, 52425 Jülich, Germany
4 shared publications - Anne Kleinert
Institute of Meteorology and Climate Research Atmospheric Trace Gases and Remote Sensing (IMKASF), Karlsruhe Institute of Technology, Karlsruhe, Germany
3 shared publications - Egon Zimmermann
Forschungszentrum Jülich
3 shared publications
Latest Publications
- 10 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 1966-1972
Calibration of the Deposited Energy in CMOS Imagers for Particle Detection on Nanosatellites
Commercial off-the-shelf (COTS) CMOS sensors are increasingly used in scientific applications on nanosatellites. Applying a software-based approach and in addition to their image acquisitions tasks, these CMOS sensors can be used to detect ionizing particles to improve the fault tolerance of imaging instruments on nanosatellites without the need for additional hardware. A challenge in using COTS components for this approach is that essential radiation test data and important parameters such as the thickness of the sensitive epitaxial layer are typically not available. With a simplified calibration approach, we determine the epitaxial layer thickness and calibrate the deposited energy sensitivity with minimal measurement time and steps and minor requirements on the test facility. A forward model for particle track length determination with an increased angle scattering of incident protons is used to handle stronger parameter uncertainties of the test setup. It is shown that the currently used CMOS sensor (HWK1910A) is a suitable candidate for a radiation monitor, based on the determined epitaxial layer thickness and the deposited energy calibration factor, in combination with the in-orbit mission data. This enables capabilities for more individual protection measures in case of unexpected radiation environments.
- 10 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 1966-1972
Calibration of the Deposited Energy in CMOS Imagers for Particle Detection on Nanosatellites
Commercial off-the-shelf (COTS) CMOS sensors are increasingly used in scientific applications on nanosatellites. Applying a software-based approach and in addition to their image acquisitions tasks, these CMOS sensors can be used to detect ionizing particles to improve the fault tolerance of imaging instruments on nanosatellites without the need for additional hardware. A challenge in using COTS components for this approach is that essential radiation test data and important parameters such as the thickness of the sensitive epitaxial layer are typically not available. With a simplified calibration approach, we determine the epitaxial layer thickness and calibrate the deposited energy sensitivity with minimal measurement time and steps and minor requirements on the test facility. A forward model for particle track length determination with an increased angle scattering of incident protons is used to handle stronger parameter uncertainties of the test setup. It is shown that the currently used CMOS sensor (HWK1910A) is a suitable candidate for a radiation monitor, based on the determined epitaxial layer thickness and the deposited energy calibration factor, in combination with the in-orbit mission data. This enables capabilities for more individual protection measures in case of unexpected radiation environments.
- 1 July 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Applied Remote Sensing
- Vol. 13 (03) , 1-17
System-on-module-based long-life electronics for remote sensing imaging with CubeSats in low-earth-orbits
CubeSats have become very popular science platforms in the past decades, leading to a continuously increasing number of developers in the academic field. For science missions, customized payload electronics have to be developed, depending on measurement tasks and requirements. Especially for the deployment of complex remote sensing payloads, state-of-the-art performance is needed to provide operational control and specific data processing, e.g., for image sensors. Highly integrated system-on-module (SoM) architectures offer low resource requirements regarding power and mass, but moderate to high processing power capabilities. However, a requirement to use a standard SoM in a satellite is to quantify its radiation tolerance. The radiation environment has been modeled, estimating the hazards at module level and reducing the risks to an acceptable level by applying appropriate mitigation techniques. This approach results in a sensor electronics design that combines hardware and software redundancies to assure system availability and reliability for long-life science missions in low earth orbits. Integrated in a miniaturized limb sounding instrument for atmospheric remote sensing imaging, the payload electronics will be deployed on a technology demonstration satellite for in-orbit verification.
- 1 July 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Applied Remote Sensing
- Vol. 13 (03) , 1-17
System-on-module-based long-life electronics for remote sensing imaging with CubeSats in low-earth-orbits
CubeSats have become very popular science platforms in the past decades, leading to a continuously increasing number of developers in the academic field. For science missions, customized payload electronics have to be developed, depending on measurement tasks and requirements. Especially for the deployment of complex remote sensing payloads, state-of-the-art performance is needed to provide operational control and specific data processing, e.g., for image sensors. Highly integrated system-on-module (SoM) architectures offer low resource requirements regarding power and mass, but moderate to high processing power capabilities. However, a requirement to use a standard SoM in a satellite is to quantify its radiation tolerance. The radiation environment has been modeled, estimating the hazards at module level and reducing the risks to an acceptable level by applying appropriate mitigation techniques. This approach results in a sensor electronics design that combines hardware and software redundancies to assure system availability and reliability for long-life science missions in low earth orbits. Integrated in a miniaturized limb sounding instrument for atmospheric remote sensing imaging, the payload electronics will be deployed on a technology demonstration satellite for in-orbit verification.
- Open Access
- 1 April 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Applied Remote Sensing
- Vol. 13 (02) , 024501-12
AtmoCube A1: airglow measurements in the mesosphere and lower thermosphere by spatial heterodyne interferometry
The University of Wuppertal and Research Center Juelich started the Development Initiative for Small Satellites Exploring Climate processes by Tomography, called DISSECT, together with German and Canadian research institutes and universities. The goal was to develop a small instrument to measure spectrally resolved radiation in the middle and upper atmospheres at high spatial resolution. The payload should be capable of deriving three-dimensional (3-D) information about atmospheric gravity wave patterns. The design should be simple with no movable parts in order to save power and to increase reliability. The instrument should fit into a small volume and should have a high optical throughput. The design should be easily adaptable to other scientific objectives.
- 1 April 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Applied Remote Sensing
- Vol. 13 (02) , 024501-12
Open AccessAtmoCube A1: airglow measurements in the mesosphere and lower thermosphere by spatial heterodyne interferometry
The University of Wuppertal and Research Center Juelich started the Development Initiative for Small Satellites Exploring Climate processes by Tomography, called DISSECT, together with German and Canadian research institutes and universities. The goal was to develop a small instrument to measure spectrally resolved radiation in the middle and upper atmospheres at high spatial resolution. The payload should be capable of deriving three-dimensional (3-D) information about atmospheric gravity wave patterns. The design should be simple with no movable parts in order to save power and to increase reliability. The instrument should fit into a small volume and should have a high optical throughput. The design should be easily adaptable to other scientific objectives.
- 1 January 2018
- Published by Optica Publishing Group
- p. FM3B.1
A Miniaturized Limb Sounder Utilizing a Spatial Heterodyne Spectrometer for the Observation of the Molecular Oxygen Atmospheric Band
A CubeSat-sized limb sounder utilizing a Spatial Heterodyne Spectrometer for the detection of the O2 Atmospheric A-Band is presented. The purpose of the instrument is to measure vertical profiles of temperature in the middle atmosphere.
- 1 January 2018
- Published by Optica Publishing Group
- p. FM3B.1
A Miniaturized Limb Sounder Utilizing a Spatial Heterodyne Spectrometer for the Observation of the Molecular Oxygen Atmospheric Band
A CubeSat-sized limb sounder utilizing a Spatial Heterodyne Spectrometer for the detection of the O2 Atmospheric A-Band is presented. The purpose of the instrument is to measure vertical profiles of temperature in the middle atmosphere.
- Open Access
- 7 August 2015
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 8 (8) , 3147-3161
New calibration noise suppression techniques for the GLORIA limb imager
The Gimballed Limb Observer for Radiance Imaging of the Atmosphere (GLORIA) presents new opportunities for the retrieval of trace gases in the upper troposphere and lower stratosphere. The radiometric calibration of the measured signal is achieved using in-flight measurements of reference blackbody and upward-pointing "deep space" scenes. In this paper, we present techniques developed specifically to calibrate GLORIA data exploiting the instrument's imaging capability. The algorithms discussed here make use of the spatial correlation of parameters across GLORIA's detector pixels in order to mitigate the noise levels and artefacts in the calibration measurements. This is achieved by combining a priori and empirical knowledge about the instrument background radiation with noise-mitigating compression methods, specifically low-pass filtering and principal component analysis (PCA). In addition, a new software package for the processing of GLORIA data is introduced which allows us to generate calibrated spectra from raw measurements in a semi-automated data processing chain.
- 7 August 2015
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 8 (8) , 3147-3161
Open AccessNew calibration noise suppression techniques for the GLORIA limb imager
The Gimballed Limb Observer for Radiance Imaging of the Atmosphere (GLORIA) presents new opportunities for the retrieval of trace gases in the upper troposphere and lower stratosphere. The radiometric calibration of the measured signal is achieved using in-flight measurements of reference blackbody and upward-pointing "deep space" scenes. In this paper, we present techniques developed specifically to calibrate GLORIA data exploiting the instrument's imaging capability. The algorithms discussed here make use of the spatial correlation of parameters across GLORIA's detector pixels in order to mitigate the noise levels and artefacts in the calibration measurements. This is achieved by combining a priori and empirical knowledge about the instrument background radiation with noise-mitigating compression methods, specifically low-pass filtering and principal component analysis (PCA). In addition, a new software package for the processing of GLORIA data is introduced which allows us to generate calibrated spectra from raw measurements in a semi-automated data processing chain.
- Open Access
- 19 June 2015
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 8 (6) , 2509-2520
Validation of first chemistry mode retrieval results from the new limb-imaging FTS GLORIA with correlative MIPAS-STR observations
We report first chemistry mode retrieval results from the new airborne limb-imaging infrared FTS (Fourier transform spectrometer) GLORIA (Gimballed Limb Observer for Radiance Imaging of the Atmosphere) and comparisons with observations by the conventional airborne limb-scanning infrared FTS MIPAS-STR (Michelson Interferometer for Passive Atmospheric Sounding – STRatospheric aircraft). For GLORIA, the flights aboard the high-altitude research aircraft M55 Geophysica during the ESSenCe campaign (ESa Sounder Campaign 2011) were the very first in field deployment after several years of development. The simultaneous observations of GLORIA and MIPAS-STR during the flight on 16 December 2011 inside the polar vortex and under conditions of optically partially transparent polar stratospheric clouds (PSCs) provided us the first opportunity to compare the observations by two different infrared FTS generations directly. We validate the GLORIA results with MIPAS-STR based on the lower vertical resolution of MIPAS-STR and compare the vertical resolutions of the instruments derived from their averaging kernels. The retrieval results of temperature, HNO3, O3, H2O, CFC-11 and CFC-12 show reasonable agreement of GLORIA with MIPAS-STR and collocated in situ observations. For the horizontally binned hyperspectral limb images, the GLORIA sampling outnumbered the horizontal cross-track sampling of MIPAS-STR by up to 1 order of magnitude. Depending on the target parameter, typical vertical resolutions of 0.5 to 2.0 km were obtained for GLORIA and are typically a factor of 2 to 4 better compared to MIPAS-STR. While the improvement of the performance, characterization and data processing of GLORIA are the subject of ongoing work, the presented first results already demonstrate the considerable gain in sampling and vertical resolution achieved with GLORIA.
- 19 June 2015
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 8 (6) , 2509-2520
Open AccessValidation of first chemistry mode retrieval results from the new limb-imaging FTS GLORIA with correlative MIPAS-STR observations
We report first chemistry mode retrieval results from the new airborne limb-imaging infrared FTS (Fourier transform spectrometer) GLORIA (Gimballed Limb Observer for Radiance Imaging of the Atmosphere) and comparisons with observations by the conventional airborne limb-scanning infrared FTS MIPAS-STR (Michelson Interferometer for Passive Atmospheric Sounding – STRatospheric aircraft). For GLORIA, the flights aboard the high-altitude research aircraft M55 Geophysica during the ESSenCe campaign (ESa Sounder Campaign 2011) were the very first in field deployment after several years of development. The simultaneous observations of GLORIA and MIPAS-STR during the flight on 16 December 2011 inside the polar vortex and under conditions of optically partially transparent polar stratospheric clouds (PSCs) provided us the first opportunity to compare the observations by two different infrared FTS generations directly. We validate the GLORIA results with MIPAS-STR based on the lower vertical resolution of MIPAS-STR and compare the vertical resolutions of the instruments derived from their averaging kernels. The retrieval results of temperature, HNO3, O3, H2O, CFC-11 and CFC-12 show reasonable agreement of GLORIA with MIPAS-STR and collocated in situ observations. For the horizontally binned hyperspectral limb images, the GLORIA sampling outnumbered the horizontal cross-track sampling of MIPAS-STR by up to 1 order of magnitude. Depending on the target parameter, typical vertical resolutions of 0.5 to 2.0 km were obtained for GLORIA and are typically a factor of 2 to 4 better compared to MIPAS-STR. While the improvement of the performance, characterization and data processing of GLORIA are the subject of ongoing work, the presented first results already demonstrate the considerable gain in sampling and vertical resolution achieved with GLORIA.
- Open Access
- 20 October 2014
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 7 (10) , 3565-3577
Instrument concept of the imaging Fourier transform spectrometer GLORIA
The Gimballed Limb Observer for Radiance Imaging of the Atmosphere (GLORIA) is an imaging limb emission sounder operating in the thermal infrared region. It is designed to provide measurements of the upper troposphere/lower stratosphere with high spatial and high spectral resolution. The instrument consists of an imaging Fourier transform spectrometer integrated into a gimbal. The assembly can be mounted in the belly pod of the German High Altitude and Long Range research aircraft (HALO) and in instrument bays of the Russian M55 Geophysica. Measurements are made in two distinct modes: the chemistry mode emphasises chemical analysis with high spectral resolution, and the dynamics mode focuses on dynamical processes of the atmosphere with very high spatial resolution. In addition, the instrument allows tomographic analyses of air volumes. The first measurement campaigns have shown compliance with key performance and operational requirements.
- 20 October 2014
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 7 (10) , 3565-3577
Open AccessInstrument concept of the imaging Fourier transform spectrometer GLORIA
The Gimballed Limb Observer for Radiance Imaging of the Atmosphere (GLORIA) is an imaging limb emission sounder operating in the thermal infrared region. It is designed to provide measurements of the upper troposphere/lower stratosphere with high spatial and high spectral resolution. The instrument consists of an imaging Fourier transform spectrometer integrated into a gimbal. The assembly can be mounted in the belly pod of the German High Altitude and Long Range research aircraft (HALO) and in instrument bays of the Russian M55 Geophysica. Measurements are made in two distinct modes: the chemistry mode emphasises chemical analysis with high spectral resolution, and the dynamics mode focuses on dynamical processes of the atmosphere with very high spatial resolution. In addition, the instrument allows tomographic analyses of air volumes. The first measurement campaigns have shown compliance with key performance and operational requirements.
- 26 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 53 (3) , 704-708
Real time data acquisition and online signal processing for magnetoencephalography
To establish improved therapies for patients suffering from severe neurological and psychiatric diseases, a demand controlled and desynchronizing brain-pacemaker has been developed with techniques from statistical physics and nonlinear dynamics. To optimize the novel therapeutic approach, brain activity is investigated with a Magnetoencephalography (MEG) system prior to surgery. For this, a real time data acquisition system for a 148 channel MEG and online signal processing for artifact rejection, filtering, cross trial phase resetting analysis and three-dimensional (3-D) reconstruction of the cerebral current sources was developed. The developed PCI bus hardware is based on a FPGA and DSP design, using the benefits from both architectures. The reconstruction and visualization of the 3-D volume data is done by the PC which hosts the real time DAQ and pre-processing board. The framework of the MEG-online system is introduced and the architecture of the real time DAQ board and online reconstruction is described. In addition we show first results with the MEG-Online system for the investigation of dynamic brain activities in relation to external visual stimulation, based on test data sets.
- 26 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 53 (3) , 704-708
Real time data acquisition and online signal processing for magnetoencephalography
To establish improved therapies for patients suffering from severe neurological and psychiatric diseases, a demand controlled and desynchronizing brain-pacemaker has been developed with techniques from statistical physics and nonlinear dynamics. To optimize the novel therapeutic approach, brain activity is investigated with a Magnetoencephalography (MEG) system prior to surgery. For this, a real time data acquisition system for a 148 channel MEG and online signal processing for artifact rejection, filtering, cross trial phase resetting analysis and three-dimensional (3-D) reconstruction of the cerebral current sources was developed. The developed PCI bus hardware is based on a FPGA and DSP design, using the benefits from both architectures. The reconstruction and visualization of the 3-D volume data is done by the PC which hosts the real time DAQ and pre-processing board. The framework of the MEG-online system is introduced and the architecture of the real time DAQ board and online reconstruction is described. In addition we show first results with the MEG-Online system for the investigation of dynamic brain activities in relation to external visual stimulation, based on test data sets.
- 19 August 2004
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 35 (03) , 265
Novel Modulating Deep Brain Stimulation Techniques based on Real-Time Model in the Loop Concepts
To improve deep brain stimulation (DBS), we have studied stimulation-induced dynamics in target areas for DBS in mathematical models. We have implemented these neuronal networks on special fast digital hardware. Our real-time models enable us to simulate stimulation-induced processes in patients under real-time conditions. Our approach makes it possible to evaluate and optimize software and hardware realizing our novel demand-controlled DBS techniques (so-called model in the loop concept). The models and the control algorithms have been coded with the graphical programming language SIMULINK by Mathworks which enables a modification of the model dynamics and the control concepts in a fast and transparent way and thus facilitates and improves the interdisciplinary research in the field of neuromodulation. The goal of our approach is the design of novel stimulation protocols which specifically modulate the affected neuronal dynamics.
- 19 August 2004
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 35 (03) , 265
Novel Modulating Deep Brain Stimulation Techniques based on Real-Time Model in the Loop Concepts
To improve deep brain stimulation (DBS), we have studied stimulation-induced dynamics in target areas for DBS in mathematical models. We have implemented these neuronal networks on special fast digital hardware. Our real-time models enable us to simulate stimulation-induced processes in patients under real-time conditions. Our approach makes it possible to evaluate and optimize software and hardware realizing our novel demand-controlled DBS techniques (so-called model in the loop concept). The models and the control algorithms have been coded with the graphical programming language SIMULINK by Mathworks which enables a modification of the model dynamics and the control concepts in a fast and transparent way and thus facilitates and improves the interdisciplinary research in the field of neuromodulation. The goal of our approach is the design of novel stimulation protocols which specifically modulate the affected neuronal dynamics.