FSFabiana Suelen Figueredo de Siqueira

Fabiana Suelen Figueredo de Siqueira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fabiana Suelen Figueredo de Siqueira has a total of 142 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Does localized irradiance of poly-wave LED influence the bonding performance of universal adhesives to dentin?

    by E Sutil, M Wendlinger, Afm Cardenas, Fsf de Siqueira, Cj Soares, S Geraldeli, Ad Loguercio


  • Two-year bonding performance of universal adhesives with an additional hydrophobic resin coat containing 45S5 on eroded dentin surface

    by A.B.B. Moreira, L. Cantanhede, P.H.A. Moreira, C. Pulido, M.C.R. Binz Ordóñez, A.D. Loguercio, F.S.F. Siqueira, A.F.M. Cardenas


  • Effect of proanthocyanidin and riboflavin associated with dimethyl sulfoxide in eroded dentine: Six-year in vitro evaluation

    by Michel Wendlinger, Gabriel David Cochinski, Pedro Henrique de Aguiar Moreira, Andres Felipe Millan Cardenas, Fabiana Suelen Figueredo de Siqueira, Thiago Henrique Scarabello Stape, Arzu Tezvergil-Mutluay, Alessandro D. Loguercio


  • Open Access

    EFICÁCIA CLÍNICA DO INFILTRANTE RESINOSO NO TRATAMENTO DE LESÕES DE MANCHAS BRANCAS: UMA REVISÃO SISTEMATIZADA

    by Fabson Tinoco Ericeira, Thays Alves Rodrigues, Lylia Maria Rocha Alves, Isabela Dequeixes Muniz, Letícia Alves de Carvalho Silva, Vanessa Ferreira da Silva, Fabiana Suelen Figueredo de Siqueira

    Lesões de mancha branca (LMB) são definidas como uma desmineralização local capaz de aumentar a porosidade do esmalte dental afetado, podendo ser geradas por fatores intrínsecos ou extrínsecos. O objetivo do presente trabalho é avaliar o desempenho e eficácia do infiltrante resinoso no tratamento de lesões de mancha branca, assim como suas características. Elaborado por meio de revisão de literatura narrativa qualitativa que utilizou como base de dados a plataforma Pubmed com um lapso temporal de 2020 a 2024, esta pesquisa, inicialmente gerou um total de 20 artigos e após leitura de título e resumo foram selecionados 18 artigos para a construção do mesmo. Embasado nessa pesquisa, sintetizou-se que a utilização de infiltrante resinoso em lesões de mancha branca é capaz de fornecer melhores condições mecânicas como microdureza, lisura e resistência associados a estética eficiente, que é capaz de gerar semelhança entre tecido tratado e tecido sadio de forma duradoura. Definindo assim, o infiltrante resinoso como um tratamento eficiente para LMBs, possuindo limites relacionados à extensão da LMB e alimentação do paciente, conferindo a possibilidade de adição de substâncias com objetivo de melhora de desempenho do mesmo.

  • Open Access

    Analysis of Mechanical Properties and Printing Orientation Influence of Composite Resin for 3D Printing Compared to Conventional Resin

    by Leonardo V. Araújo, Fabiana S. Figuerêdo de Siqueira, Rayssa F. Cavaleiro de Macedo, Felipe S. Gomes, Gustavo G. Castro, Daniela B. Dibai, Etevaldo M. Maia Filho, Rudys R. J. Tavarez

    This study aimed to compare the flexural strength, surface roughness, and microhardness of a resin for three-dimensional (3D) printing and a conventional composite resin and to evaluate whether the printing orientation influences these properties. To evaluate the flexural resistance, test specimens were produced and divided into four groups: three groups of resins for 3D printing with inclinations of 0°, 45°, and 90° and one group of conventional composite resin. Forty discs were produced and subjected to a sandpaper-polishing sequence, and the surface roughness was measured using a roughness meter. The Vickers microhardness (HV) test was performed at three different points, and the average was obtained. The results were subjected to ANOVA statistical analysis and Tukey’s test. There were statistical differences in the flexural strength and microhardness between the conventional resin and the resin used for 3D printing. No statistical difference in surface roughness was observed. The resin for 3D printing exhibited lower flexural strength and microhardness than conventional composite resins. We concluded that the resin for 3D printing had lower flexural strength and HV than the conventional composite resin but similar surface roughness. The printing orientation did not affect the flexural strength, whereas the hardness increased as the printing angle increased.


  • Open Access

    Comparative Analysis of Mechanical Properties of a Composite Resin for 3D Printing and a Conventional Resin

    by Leonardo Viana Araújo, Fabiana Figuerêdo Siqueira, Rayssa Cavaleiro Macedo, Felipe Silva Gones, Gustavo Garcia Castro, Daniela Bassi Dibai, Etevaldo Matos Maia Filho, Rudys Rodolfo Tavarez

    This study aimed to compare the flexural strength, surface roughness, and microhardness of a resin for three-dimensional (3D) printing and a conventional composite resin and to evaluate whether the printing orientation influences these properties. To evaluate the flexural resistance, test specimens were produced and divided into four groups: three groups of resins for 3D printing with inclinations of 0°, 45°, and 90°, and one group of conventional composite resin. Forty discs were produced and subjected to a sandpaper-polishing sequence, and the surface roughness was measured using a roughness meter. The Vickers microhardness test was performed at three different points, and the average was obtained. The results were subjected to ANOVA statistical analysis and Tukey's test. There were statistical differences in the flexural strength and microhardness between the conventional resin and the resin used for 3D printing. No statistical difference in surface roughness was observed. The resin for 3D printing exhibited lower flexural strength and microhardness than conventional composite resins. We concluded that the resin for 3D printing had lower flexural strength and hardness than the conventional composite resin but similar surface roughness. The printing orientation did not affect the flexural strength, whereas the hardness increased as the printing angle increased.


  • Bonding performance of universal adhesives to eroded dentine: A 6-year evaluation

    by Fabiana Suelen Figueredo de Siqueira, Michel Wendlinger, Lucila Cristina Rodrigues Araújo, Pedro Henrique de Aguiar Moreira, Andres Felipe Millan Cardenas, Thiago Saads Carvalho, Alessandra Reis, Alessandro D. Loguercio


  • Effect of irradiance and exposure time on the adhesive properties of universal adhesives after 2 years of storage

    by Karoline G. B. A. Cavalcanti, Camilo Pulido, Pedro H. A. Moreira, Camila F. Monteles, Byron L. C. Salvatierra, Fabiana S. F. Siqueira, Carlos J. Soares, Alessandra Reis, Alessandro D. Loguercio, Andres F. M. Cardenas

    Objective This study aims to evaluate the effects of exposure time and irradiance on the dentin bonding properties (microtensile bond strength (μTBS) and nanoleakage (NL)) of the Clearfil Universal Bond Quick (CUQ) adhesive and Scotchbond Universal Adhesive (SBU) immediately and after 2 years of water storage. Material and methods Hence, 128 human molars were randomly assigned to 16 groups based on adhesive strategy, irradiance/exposure times, and storage time for each universal adhesive tested. The adhesives were applied using the etch-and-rinse and self-etch strategies and were light-cured using four different irradiance/exposure times: 1400 mW/cm2 for 5 s (1400 × 5), 1400 mW/cm2 for 10 s (1400 × 10), 3200 mW/cm2 for 5 s (3200 × 5), and 3200 mW/cm2 for 10 s (3200 × 10). Then, each sample was restored and sectioned into a resin-dentin bonded stick to be tested for μTBS and NL (immediately and after 2 years of water storage). The mean μTBS and NL of all resin-dentin bonded sticks from the same hemi-tooth (factor time) were statistically analyzed using a three-way ANOVA and Tukey’s test (a = 0.05). Results Despite a significant decrease in the μTBS values for all groups after 2 years of water storage, the 3200 × 5 group showed higher μTBS values, whereas the 3200 × 10 group showed lower μTBS values for both universal adhesives tested. Although a significant increase in the NL values was observed for all groups after 2 years of water storage, the 3200 × 10 group showed higher NL values than the other groups (p < 0.001). Conclusion Results indicate that light-curing the adhesive layer with 14–16 J/cm2 led to an improvement in the stability of the resin-dentin adhesive interface. A longer exposure time (10 s) coupled with a higher irradiance (3200 mW/cm2) resulted in a greater degree of degradation of the adhesive interface. Clinical significance To guarantee better stability of the adhesive interface, clinicians could be preferred a light-cured universal adhesive layer with 14–16 J/cm2. Higher irradiances should be avoided.


  • Open Access

    Development and Physicochemical Characterization of Eugenia brejoensis Essential Oil-Doped Dental Adhesives with Antimicrobial Action towards Streptococcus mutans

    by Maury Luz Pereira, Danyelle Cristina Pereira Santos, Carlos Alberto Mendes Soares Júnior, Tamyris Alicely Xavier Nogueira Bazan, Clovis Macêdo Bezerra Filho, Márcia Vanusa da Silva, Maria Tereza dos Santos Correia, Andres Felipe Millan Cardenas, Fabiana Suelen Figuerêdo de Siqueira, Edilausson Moreno Carvalho, et al.

    Dental caries is a multifactorial, biofilm-dependent infectious disease that develops when detrimental changes occur in the oral cavity microenvironment. The antimicrobial and antivirulence properties of the essential oil obtained from the leaves of Eugenia brejoensis Mazine (EBEO) have been reported against Gram-positive and Gram-negative bacteria. Herein, the antimicrobial action of EBEO towards Streptococcus mutans is reported, along with the development and characterization of dental adhesives doped with. The minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of EBEO were determined against S. mutans, while its toxicity was analyze using Tenebrio molitor larvae. EBEO (MIC and 10×MIC) was incorporated into the Ambar Advanced Polymerization System® (Ambar APS), a two-step total-etch adhesive system (FGM Dental Group), and the antibiofilm action was evaluated. The reflective strength, modulus of elasticity, degree of conversion, and maximum rate of polymerization of each adhesive were also determined. The MIC and MBC values of EBEO against S. mutans were 62.5 µg/mL. The tested concentrations of EBEO were non-toxic to T. molitor larvae. The formation of S. mutans biofilms was significantly inhibited by EBEO and EBEO-coated resin discs (p < 0.05). Importantly, EBEO incorporation did not affect the mechanical and physicochemical properties in relation to oil-free adhesive version. EBEO showed strong antibacterial and antibiofilm activity against S. mutans, no toxicity effect against T. molitor larvae, and did not jeopardize the physical-chemical properties tested.


  • Open Access

    Effect of Bonding Protocols on the Performance of Luting Agents Applied to CAD–CAM Composites

    by Bruna Hilgemberg, Fabiana Suelen Figuerêdo de Siqueira, Andres Felipe Millan Cardenas, Josiane Loch Ribeiro, Andrés Dávila-Sánchez, Salvatore Sauro, Alessandro Dourado Loguercio, Cesar Augusto Galvao Arrais

    This in vitro study aimed to evaluate the effect of different bonding strategies on the micro-shear bond strength (μSBS) of luting agents to CAD–CAM composites. Surface scanning electron microscopy (SEM) and spectroscopy by energy-dispersive X-ray spectroscopy (EDS) were performed to analyze the surfaces of the composite before and after bonding treatment. Three CAD–CAM composites were evaluated: Lava Ultimate restorative (LU), Brava Blocks (BR), and Vita Enamic (VE). The LU and BR surfaces were sandblasted using aluminum oxide, while the VE surfaces were etched using a 5% hydrofluoric acid gel according to the manufacturers’ recommendations. All surfaces were subjected to the following bonding strategies (n = 15): adhesive with silane and MDP (ScotchBond Universal, 3M Oral Care, St Paul, MI, USA); adhesive with MDP (Ambar Universal, FGM, Joinville, Brazil); adhesive without silane or MDP (Prime&Bond Elect, Dentsply Sirona, Charlotte, NC, USA), pure silane without MDP (Angelus, Londrina, Brazil), and pure silane with MDP (Monobond N, Ivoclar Vivadent, Schaan, Liechtenstei). Afterwards, tygons were filled with RelyX Ultimate (3M Oral Care), AllCem (FGM), or Enforce (Dentsply Sirona), which were light-cured and subjected to the μSBS test. Data were analyzed using two-way ANOVA and Bonferroni’s post hoc test (α = 0.05). Additional blocks (n = 15) were subjected to scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) before and after the surface treatment. The μSBS values on VE surfaces were higher than those observed on LU and BR surfaces (p < 0.001). Silane without MDP (Allcem) promoted the highest μSBS values, while silane with MDP (RelyX Ultimate) provided the highest values among all bonding strategies (p < 0.001). Enforce promoted no significant difference in μSBS values. SEM and EDS analyses detected noticeable changes to the surface morphology and composition after the surface treatment. The effectiveness of the bonding strategy may vary according not only to the CAD–CAM composite but also to resin cement/bonding agent/silane used.