Pedro Henrique de Aguiar Moreira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pedro Henrique de Aguiar Moreira has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Dourado Loguercio
Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
10 shared publications - Fabiana Suelen Figueredo de Siqueira
Department of Restorative Dentistry, Ceuma University, São Luís, Maranhão, Brazil
8 shared publications - Andres Felipe Millan Cardenas
Universidade Ceuma, Brazil
7 shared publications - Alessandra Reis
Department of Restorative Dentistry State University of Ponta Grossa Ponta Grossa Paraná Brazil
3 shared publications - Gabriel David Cochinski
Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
3 shared publications - Carolina Pardo-Díaz
Restorative Dentistry Departament, Faculty of Dentistry, Dental School, University of Chile, Santiago, Chile
2 shared publications
Latest Publications
- Open Access
- 22 September 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Effect of Silane Incorporation on the Bonding Performance of Universal Adhesives to Dentin
Purpose: The effect of silane in universal adhesives (UAs) on dentin adhesion remains unclear. Therefore, this study evaluated the dentin bonding of UAs with and without silane immediately and after thermocycling. Materials and Methods: Sixty‐four sound human molars were randomly assigned to eight groups according to silane incorporation (UAs without silane: Scotchbond Universal [SBU] and Ambar Universal APS [AUA]; and UAs with silane: Scotchbond Universal Plus [SUP] and Ambar Universal APS Plus [AUP]), bonding strategy (etch‐and‐rinse [ER] or self‐etch [SE]), and evaluation time (immediate or after thermocycling). Adhesives were applied to occlusal dentin and restored with composite resin. Resin–dentin sticks (0.8 mm 2 ) were prepared for microtensile bond strength (μTBS), nanoleakage (NL), and degree of conversion (DC). Data were statistically analyzed ( α = 0.05). Results: Thermocycling significantly reduced μTBS for all adhesives ( p < 0.001), while silane incorporation had no effect ( p = 0.31). ER showed higher μTBS than SE ( p < 0.001). After thermocycling, NL was similar among adhesives in ER but differed in SE, particularly between SBU and SUP ( p < 0.001). DC was unaffected by adhesive type or bonding strategy. Conclusions: Dentin bonding of UAs was mainly influenced by bonding strategy and aging, whereas silane incorporation showed a limited effect.
- 22 September 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Open AccessEffect of Silane Incorporation on the Bonding Performance of Universal Adhesives to Dentin
Purpose: The effect of silane in universal adhesives (UAs) on dentin adhesion remains unclear. Therefore, this study evaluated the dentin bonding of UAs with and without silane immediately and after thermocycling. Materials and Methods: Sixty‐four sound human molars were randomly assigned to eight groups according to silane incorporation (UAs without silane: Scotchbond Universal [SBU] and Ambar Universal APS [AUA]; and UAs with silane: Scotchbond Universal Plus [SUP] and Ambar Universal APS Plus [AUP]), bonding strategy (etch‐and‐rinse [ER] or self‐etch [SE]), and evaluation time (immediate or after thermocycling). Adhesives were applied to occlusal dentin and restored with composite resin. Resin–dentin sticks (0.8 mm 2 ) were prepared for microtensile bond strength (μTBS), nanoleakage (NL), and degree of conversion (DC). Data were statistically analyzed ( α = 0.05). Results: Thermocycling significantly reduced μTBS for all adhesives ( p < 0.001), while silane incorporation had no effect ( p = 0.31). ER showed higher μTBS than SE ( p < 0.001). After thermocycling, NL was similar among adhesives in ER but differed in SE, particularly between SBU and SUP ( p < 0.001). DC was unaffected by adhesive type or bonding strategy. Conclusions: Dentin bonding of UAs was mainly influenced by bonding strategy and aging, whereas silane incorporation showed a limited effect.
- Open Access
- 31 August 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Air‐Abrasion With Aluminum Oxide Particles in Non‐Carious Cervical Lesions: Impact on Sclerotic Superficial Layer, Surface Topography, and Restorative Adhesive Performance
Objective: To evaluate the effect of airborne‐particle abrasion (APA) with aluminum oxide on superficial dentin sclerosis, surface topography, and bonding performance of a universal adhesive in natural non‐carious cervical lesions (NCCLs), using dentin classification by the North Carolina Index (NCI) and Optical Coherence Tomography Index (OCT). Methods: Forty‐eight premolars with natural NCCLs were distributed according to dentin sclerosis classification (non‐sclerotic or sclerotic) by NCI and OCT, with concordant and discordant (dentin types) classifications into four APA treatment groups ( n = 8), and two untreated groups (control, n = 8, non‐sclerotic and sclerotic, for adhesive testing). Pre‐ and post‐treatment analyses included stereomicroscopy, OCT, microcomputed tomography (volume and thickness loss), and 3D optical profilometry (surface roughness). Adhesive performance of a universal adhesive was assessed by microtensile bond strength (μTBS), nanoleakage (scanning electron microscopy), and chemical mapping (micro‐Raman spectroscopy). Data were analyzed with parametric and non‐parametric tests ( α = 0.05). Results: APA did not significantly change dentin classification by NCI or OCT ( p > 0.05) but removed a superficial layer (volume loss: 0.33 mm 3 ; thickness loss: 34 μm) and significantly increased surface roughness ( p < 0.001), without dentin‐type differences ( p = 0.38). Adhesive performance was substrate‐dependent: APA improved μTBS in sclerotic dentin (per OCT) and reduced it in non‐sclerotic dentin (per OCT). Nanoleakage did not differ among groups ( p > 0.05). Conclusion: APA modified dentin surface topography without removing superficial dentin sclerosis, while the effect on bonding was substrate‐dependent. Clinical Significance: APA‐induced surface modification, including volume loss and increased surface roughness, improved bonding performance in sclerotic NCCL dentin without completely removing the sclerotic layer.
- 31 August 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Open AccessAir‐Abrasion With Aluminum Oxide Particles in Non‐Carious Cervical Lesions: Impact on Sclerotic Superficial Layer, Surface Topography, and Restorative Adhesive Performance
Objective: To evaluate the effect of airborne‐particle abrasion (APA) with aluminum oxide on superficial dentin sclerosis, surface topography, and bonding performance of a universal adhesive in natural non‐carious cervical lesions (NCCLs), using dentin classification by the North Carolina Index (NCI) and Optical Coherence Tomography Index (OCT). Methods: Forty‐eight premolars with natural NCCLs were distributed according to dentin sclerosis classification (non‐sclerotic or sclerotic) by NCI and OCT, with concordant and discordant (dentin types) classifications into four APA treatment groups ( n = 8), and two untreated groups (control, n = 8, non‐sclerotic and sclerotic, for adhesive testing). Pre‐ and post‐treatment analyses included stereomicroscopy, OCT, microcomputed tomography (volume and thickness loss), and 3D optical profilometry (surface roughness). Adhesive performance of a universal adhesive was assessed by microtensile bond strength (μTBS), nanoleakage (scanning electron microscopy), and chemical mapping (micro‐Raman spectroscopy). Data were analyzed with parametric and non‐parametric tests ( α = 0.05). Results: APA did not significantly change dentin classification by NCI or OCT ( p > 0.05) but removed a superficial layer (volume loss: 0.33 mm 3 ; thickness loss: 34 μm) and significantly increased surface roughness ( p < 0.001), without dentin‐type differences ( p = 0.38). Adhesive performance was substrate‐dependent: APA improved μTBS in sclerotic dentin (per OCT) and reduced it in non‐sclerotic dentin (per OCT). Nanoleakage did not differ among groups ( p > 0.05). Conclusion: APA modified dentin surface topography without removing superficial dentin sclerosis, while the effect on bonding was substrate‐dependent. Clinical Significance: APA‐induced surface modification, including volume loss and increased surface roughness, improved bonding performance in sclerotic NCCL dentin without completely removing the sclerotic layer.
- Open Access
- 26 January 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 167, 106524
Bioactive and antibacterial universal adhesives containing ZnO/Cu and bioactive glass nanoparticles
- 26 January 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 167, 106524
Open AccessBioactive and antibacterial universal adhesives containing ZnO/Cu and bioactive glass nanoparticles
- 21 May 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (7) , 827-838
Effect of proanthocyanidin and riboflavin associated with dimethyl sulfoxide in eroded dentine: Six-year in vitro evaluation
- 21 May 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (7) , 827-838
Effect of proanthocyanidin and riboflavin associated with dimethyl sulfoxide in eroded dentine: Six-year in vitro evaluation
- 20 August 2024
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 134
Do in vitro and in situ erosive challenges alter the bonding performance of universal adhesives?
- 20 August 2024
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 134
Do in vitro and in situ erosive challenges alter the bonding performance of universal adhesives?
- 23 July 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 136, 104633
Bonding performance of universal adhesives to eroded dentine: A 6-year evaluation
- 23 July 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 136, 104633
Bonding performance of universal adhesives to eroded dentine: A 6-year evaluation
- 17 July 2023
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 27 (9) , 5223-5232
Effect of irradiance and exposure time on the adhesive properties of universal adhesives after 2 years of storage
Objective This study aims to evaluate the effects of exposure time and irradiance on the dentin bonding properties (microtensile bond strength (μTBS) and nanoleakage (NL)) of the Clearfil Universal Bond Quick (CUQ) adhesive and Scotchbond Universal Adhesive (SBU) immediately and after 2 years of water storage. Material and methods Hence, 128 human molars were randomly assigned to 16 groups based on adhesive strategy, irradiance/exposure times, and storage time for each universal adhesive tested. The adhesives were applied using the etch-and-rinse and self-etch strategies and were light-cured using four different irradiance/exposure times: 1400 mW/cm2 for 5 s (1400 × 5), 1400 mW/cm2 for 10 s (1400 × 10), 3200 mW/cm2 for 5 s (3200 × 5), and 3200 mW/cm2 for 10 s (3200 × 10). Then, each sample was restored and sectioned into a resin-dentin bonded stick to be tested for μTBS and NL (immediately and after 2 years of water storage). The mean μTBS and NL of all resin-dentin bonded sticks from the same hemi-tooth (factor time) were statistically analyzed using a three-way ANOVA and Tukey’s test (a = 0.05). Results Despite a significant decrease in the μTBS values for all groups after 2 years of water storage, the 3200 × 5 group showed higher μTBS values, whereas the 3200 × 10 group showed lower μTBS values for both universal adhesives tested. Although a significant increase in the NL values was observed for all groups after 2 years of water storage, the 3200 × 10 group showed higher NL values than the other groups (p < 0.001). Conclusion Results indicate that light-curing the adhesive layer with 14–16 J/cm2 led to an improvement in the stability of the resin-dentin adhesive interface. A longer exposure time (10 s) coupled with a higher irradiance (3200 mW/cm2) resulted in a greater degree of degradation of the adhesive interface. Clinical significance To guarantee better stability of the adhesive interface, clinicians could be preferred a light-cured universal adhesive layer with 14–16 J/cm2. Higher irradiances should be avoided.
- 17 July 2023
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 27 (9) , 5223-5232
Effect of irradiance and exposure time on the adhesive properties of universal adhesives after 2 years of storage
Objective This study aims to evaluate the effects of exposure time and irradiance on the dentin bonding properties (microtensile bond strength (μTBS) and nanoleakage (NL)) of the Clearfil Universal Bond Quick (CUQ) adhesive and Scotchbond Universal Adhesive (SBU) immediately and after 2 years of water storage. Material and methods Hence, 128 human molars were randomly assigned to 16 groups based on adhesive strategy, irradiance/exposure times, and storage time for each universal adhesive tested. The adhesives were applied using the etch-and-rinse and self-etch strategies and were light-cured using four different irradiance/exposure times: 1400 mW/cm2 for 5 s (1400 × 5), 1400 mW/cm2 for 10 s (1400 × 10), 3200 mW/cm2 for 5 s (3200 × 5), and 3200 mW/cm2 for 10 s (3200 × 10). Then, each sample was restored and sectioned into a resin-dentin bonded stick to be tested for μTBS and NL (immediately and after 2 years of water storage). The mean μTBS and NL of all resin-dentin bonded sticks from the same hemi-tooth (factor time) were statistically analyzed using a three-way ANOVA and Tukey’s test (a = 0.05). Results Despite a significant decrease in the μTBS values for all groups after 2 years of water storage, the 3200 × 5 group showed higher μTBS values, whereas the 3200 × 10 group showed lower μTBS values for both universal adhesives tested. Although a significant increase in the NL values was observed for all groups after 2 years of water storage, the 3200 × 10 group showed higher NL values than the other groups (p < 0.001). Conclusion Results indicate that light-curing the adhesive layer with 14–16 J/cm2 led to an improvement in the stability of the resin-dentin adhesive interface. A longer exposure time (10 s) coupled with a higher irradiance (3200 mW/cm2) resulted in a greater degree of degradation of the adhesive interface. Clinical significance To guarantee better stability of the adhesive interface, clinicians could be preferred a light-cured universal adhesive layer with 14–16 J/cm2. Higher irradiances should be avoided.
- Open Access
- 17 October 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (14)
A influência da espessura das cerâmicas nas propriedades mecânicas de cimentos resinosos duais: revisão de literatura
The objective of this study is to clarify the extent to which the thickness of the ceramics influences the light curing and thus affects the mechanical properties of dual cure resin cements, through a literature review. Articles published in online databases were searched in which they evaluated whether there is an influence of ceramic thickness on the mechanical properties of dual cure resin cements. The databases used were PubMed, LILACS and SCOPUS. The research conducted by two authors was carried out in June 2022 and obtained the final result of 6 articles selected for the review. In this research, the authors report that dual cure resin cements can be used in zirconia crowns up to 2 mm, while for monolithic lithium disilicate crowns they can be used in pieces up to 2.5 mm. After reviewing the literature on the influence of ceramic thickness on the mechanical properties of dual cure resin cements, we can consider that in pieces from 2 mm there is a decrease in mechanical properties, including microhardness and degree of conversion.
- 17 October 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (14)
Open AccessA influência da espessura das cerâmicas nas propriedades mecânicas de cimentos resinosos duais: revisão de literatura
The objective of this study is to clarify the extent to which the thickness of the ceramics influences the light curing and thus affects the mechanical properties of dual cure resin cements, through a literature review. Articles published in online databases were searched in which they evaluated whether there is an influence of ceramic thickness on the mechanical properties of dual cure resin cements. The databases used were PubMed, LILACS and SCOPUS. The research conducted by two authors was carried out in June 2022 and obtained the final result of 6 articles selected for the review. In this research, the authors report that dual cure resin cements can be used in zirconia crowns up to 2 mm, while for monolithic lithium disilicate crowns they can be used in pieces up to 2.5 mm. After reviewing the literature on the influence of ceramic thickness on the mechanical properties of dual cure resin cements, we can consider that in pieces from 2 mm there is a decrease in mechanical properties, including microhardness and degree of conversion.