James Kariuki
James Kariuki has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Brian P. Rempel
University of Alberta, Augustana Faculty
3 shared publications David King
Department of Science, University of Alberta − Augustana Campus, Camrose, Alberta T4 V 2R3, Canada
3 shared publicationsBenjamin Schmidt
University of Alberta Augustana Campus, 4901 46th Avenue
2 shared publications- Elizabeth G. McGinitie
Department of Science
2 shared publications - Emily M. Ervin
Department of Science, Augustana Campus, University of Alberta, 4901-46th Ave, Camrose, AB T4V 2R3, Canada
2 shared publications - Carly Olafson
Innovation and Portfolio Management, Canadian Blood Services, Edmonton, Alberta, Canada; Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta, Canada
1 shared publication
Latest Publications
- 26 August 2024
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 101 (9) , 3795-3804
Design and Implementation of a Mentorship Course That Utilizes Senior Undergraduate Chemistry Students As Learning Assistants in the Introductory Chemistry Laboratory to Foster Transferable Skill Development
- 26 August 2024
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 101 (9) , 3795-3804
Design and Implementation of a Mentorship Course That Utilizes Senior Undergraduate Chemistry Students As Learning Assistants in the Introductory Chemistry Laboratory to Foster Transferable Skill Development
- Open Access
- 4 May 2023
- Published by McMaster University Library in International Journal for Students as Partners
- Vol. 7 (1) , 191-197
Reflections of a professor and undergraduate student-instructors: Our experiences teaching a first-year seminar course and chemistry labs
- 4 May 2023
- Published by McMaster University Library in International Journal for Students as Partners
- Vol. 7 (1) , 191-197
Open AccessReflections of a professor and undergraduate student-instructors: Our experiences teaching a first-year seminar course and chemistry labs
- 15 February 2022
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 99 (3) , 1160-1166
Application of 3D Printers to Fabricate Low-Cost Electrode Components for Undergraduate Experiments and Research
Many electroanalytical techniques utilize three-electrode systems consisting of reference, counter, and working electrodes. These electrodes are often expensive when purchased commercially, making low-cost alternatives a vital area of research. Cheaper alternatives have been proposed; however, they often require time-consuming assembly techniques or materials that are difficult to work with. This technology report outlines the production and testing of an Ag/AgCl reference electrode, a platinum (Pt) counter electrode, and a carbon paste working electrode. These electrodes have been designed using 3D printing technology, which has become increasingly more available at educational institutions. By utilizing 3D printing technology, these adaptable designs can be produced quickly and at a fraction of the cost of commercially available electrodes. The lab-made Ag/AgCl reference and Pt counter electrodes were tested via cyclic voltammetry (CV) experiments with orange juice and ruthenium hexaamine as analytes. The results obtained were statistically similar in all obtained measurements. The carbon paste working electrode was tested in potassium ferricyanide for both variable scan rate and concentration responses. In these tests, the lab-made electrode performance compared favorably to commercial electrodes. This demonstrates the viability of our method in the production of low-cost, reliable electrodes that can be used in a variety of electroanalytical experiments.
- 15 February 2022
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 99 (3) , 1160-1166
Application of 3D Printers to Fabricate Low-Cost Electrode Components for Undergraduate Experiments and Research
Many electroanalytical techniques utilize three-electrode systems consisting of reference, counter, and working electrodes. These electrodes are often expensive when purchased commercially, making low-cost alternatives a vital area of research. Cheaper alternatives have been proposed; however, they often require time-consuming assembly techniques or materials that are difficult to work with. This technology report outlines the production and testing of an Ag/AgCl reference electrode, a platinum (Pt) counter electrode, and a carbon paste working electrode. These electrodes have been designed using 3D printing technology, which has become increasingly more available at educational institutions. By utilizing 3D printing technology, these adaptable designs can be produced quickly and at a fraction of the cost of commercially available electrodes. The lab-made Ag/AgCl reference and Pt counter electrodes were tested via cyclic voltammetry (CV) experiments with orange juice and ruthenium hexaamine as analytes. The results obtained were statistically similar in all obtained measurements. The carbon paste working electrode was tested in potassium ferricyanide for both variable scan rate and concentration responses. In these tests, the lab-made electrode performance compared favorably to commercial electrodes. This demonstrates the viability of our method in the production of low-cost, reliable electrodes that can be used in a variety of electroanalytical experiments.
- 23 July 2020
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 97 (9) , 3332-3335
Community Matters: Student–Instructor Relationships Foster Student Motivation and Engagement in an Emergency Remote Teaching Environment
The ongoing COVID-19 pandemic has disrupted face-to-face instruction in educational institutions all over the world. As instructors we had to scramble to completely change courses to emergency remote delivery, sometimes with only a few days’ notice. Herein, we present reflections on the successes and challenges we encountered following the sudden and unexpected transition to remote delivery. We also address ways that we managed the obstacles faced, from overcoming technological issues posed by remote delivery to adaptation of laboratory content for emergency remote delivery. In addition, we discuss successful strategies for assessment of student learning and student engagement in the online environment. Overall, we found that students’ motivation was high, as indicated by online class attendance and engagement with course activities. We believe that the existing strong student–instructor relationships at our small liberal arts and sciences campus contributed to the unexpectedly high level of student engagement.
- 23 July 2020
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 97 (9) , 3332-3335
Community Matters: Student–Instructor Relationships Foster Student Motivation and Engagement in an Emergency Remote Teaching Environment
The ongoing COVID-19 pandemic has disrupted face-to-face instruction in educational institutions all over the world. As instructors we had to scramble to completely change courses to emergency remote delivery, sometimes with only a few days’ notice. Herein, we present reflections on the successes and challenges we encountered following the sudden and unexpected transition to remote delivery. We also address ways that we managed the obstacles faced, from overcoming technological issues posed by remote delivery to adaptation of laboratory content for emergency remote delivery. In addition, we discuss successful strategies for assessment of student learning and student engagement in the online environment. Overall, we found that students’ motivation was high, as indicated by online class attendance and engagement with course activities. We believe that the existing strong student–instructor relationships at our small liberal arts and sciences campus contributed to the unexpectedly high level of student engagement.
- 20 September 2018
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 95 (11) , 2076-2080
Designing and Using 3D-Printed Components That Allow Students To Fabricate Low-Cost, Adaptable, Disposable, and Reliable Ag/AgCl Reference Electrodes
- 20 September 2018
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 95 (11) , 2076-2080
Designing and Using 3D-Printed Components That Allow Students To Fabricate Low-Cost, Adaptable, Disposable, and Reliable Ag/AgCl Reference Electrodes
- Open Access
Development of a Novel, Low-Cost, Disposable Wooden Pencil Graphite Electrode for Use in the Determination of Antioxidants and Other Biological Compounds
The development of portable sensors that can be used outside the lab is an active area of research in the electroanalytical field. A major focus of such research is the development of low-cost electrodes for use in these sensors. Current electrodes, such as glassy-carbon electrodes (GCEs), are costly and require time-consuming preparation. Alternatives have been proposed, including mechanical pencil-lead electrodes (MPEs). However, MPEs themselves possess numerous drawbacks, particularly structural fragility. In this paper, we present a novel pencil-graphite electrode (PGE) fabricated from a regular HB#2 pencil. This PGE is a simple, disposable, extremely low-cost alternative to GCEs ($0.30 per PGE, vs. $190 + per GCE), and possesses the structural stability that MPEs lack. PGEs were characterized by square-wave voltammetry of ferricyanide, gallic acid, uric acid, dopamine, and several foodstuffs. In all cases, PGEs demonstrated sensitivities comparable or superior to those of the GCE and MPE (LOD = 5.62 × 10−4 M PGE, 4.80 × 10−4 M GCE, 2.93 × 10−4 M MPE). Signal areas and peak heights were typically four to ten times larger for the PGE relative to the GCE.
Open AccessDevelopment of a Novel, Low-Cost, Disposable Wooden Pencil Graphite Electrode for Use in the Determination of Antioxidants and Other Biological Compounds
The development of portable sensors that can be used outside the lab is an active area of research in the electroanalytical field. A major focus of such research is the development of low-cost electrodes for use in these sensors. Current electrodes, such as glassy-carbon electrodes (GCEs), are costly and require time-consuming preparation. Alternatives have been proposed, including mechanical pencil-lead electrodes (MPEs). However, MPEs themselves possess numerous drawbacks, particularly structural fragility. In this paper, we present a novel pencil-graphite electrode (PGE) fabricated from a regular HB#2 pencil. This PGE is a simple, disposable, extremely low-cost alternative to GCEs ($0.30 per PGE, vs. $190 + per GCE), and possesses the structural stability that MPEs lack. PGEs were characterized by square-wave voltammetry of ferricyanide, gallic acid, uric acid, dopamine, and several foodstuffs. In all cases, PGEs demonstrated sensitivities comparable or superior to those of the GCE and MPE (LOD = 5.62 × 10−4 M PGE, 4.80 × 10−4 M GCE, 2.93 × 10−4 M MPE). Signal areas and peak heights were typically four to ten times larger for the PGE relative to the GCE.
- Open Access
- 6 July 2015
- Published by Taylor & Francis in International Journal of Food Properties
- Vol. 19 (4) , 826-836
Demonstrating the Minimal Impact of Cultivation Conditions on Antioxidants in Fruits and Vegetables by Differential Pulse Voltammetry
Conventionally, organically, and locally grown varieties of carrot, tomato, rhubarb, raspberry, strawberry, and bell peppers were analyzed by differential pulse voltammetry to determine the impact of cultivation conditions on produce antioxidant content. The potential (indicating antioxidant activity) and area (indicating antioxidant capacity) of the primary peaks were evaluated. Overall, no consistent trends were observed across cultivation conditions, suggesting that cultivation conditions have minimal impact on antioxidant content. This study revealed differential pulse voltammetry to be a sensitive and rapid method for antioxidant determination, with a detection and quantitation limit of 8.38 × 10−5 and 2.79 × 10−4 mol/L, respectively.
- 6 July 2015
- Published by Taylor & Francis in International Journal of Food Properties
- Vol. 19 (4) , 826-836
Open AccessDemonstrating the Minimal Impact of Cultivation Conditions on Antioxidants in Fruits and Vegetables by Differential Pulse Voltammetry
Conventionally, organically, and locally grown varieties of carrot, tomato, rhubarb, raspberry, strawberry, and bell peppers were analyzed by differential pulse voltammetry to determine the impact of cultivation conditions on produce antioxidant content. The potential (indicating antioxidant activity) and area (indicating antioxidant capacity) of the primary peaks were evaluated. Overall, no consistent trends were observed across cultivation conditions, suggesting that cultivation conditions have minimal impact on antioxidant content. This study revealed differential pulse voltammetry to be a sensitive and rapid method for antioxidant determination, with a detection and quantitation limit of 8.38 × 10−5 and 2.79 × 10−4 mol/L, respectively.
- Open Access
- 1 October 2010
- Published by Elsevier in International Journal of Electrochemical Science
- Vol. 5 (10) , 1464-1474
Determination of the Vitamin C Content of Conventionally and Organically Grown Fruits by Cyclic Voltammetry
- 1 October 2010
- Published by Elsevier in International Journal of Electrochemical Science
- Vol. 5 (10) , 1464-1474
Open AccessDetermination of the Vitamin C Content of Conventionally and Organically Grown Fruits by Cyclic Voltammetry