Carly Olafson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carly Olafson has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Celina Phan
Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta, Canada
1 shared publication - Darren H. Freed
Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
1 shared publication - Emily M. Ervin
Department of Science, Augustana Campus, University of Alberta, 4901-46th Ave, Camrose, AB T4V 2R3, Canada
1 shared publication - James Kariuki
Department of Science
1 shared publication - Jason P. Acker
Department of Laboratory Medicine and Pathology University of Alberta Edmonton Alberta Canada
1 shared publication - Kiarra Durand
Innovation and Portfolio Management, Canadian Blood Services, Edmonton, Alberta, Canada; Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta, Canada
1 shared publication
Latest Publications
- Open Access
- 7 June 2025
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 44 (11) , 1811-1820
Plasma-supplemented red cell concentrates as alternatives to whole blood in porcine ex vivo heart perfusion
- 7 June 2025
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 44 (11) , 1811-1820
Open AccessPlasma-supplemented red cell concentrates as alternatives to whole blood in porcine ex vivo heart perfusion
- Open Access
Development of a Novel, Low-Cost, Disposable Wooden Pencil Graphite Electrode for Use in the Determination of Antioxidants and Other Biological Compounds
The development of portable sensors that can be used outside the lab is an active area of research in the electroanalytical field. A major focus of such research is the development of low-cost electrodes for use in these sensors. Current electrodes, such as glassy-carbon electrodes (GCEs), are costly and require time-consuming preparation. Alternatives have been proposed, including mechanical pencil-lead electrodes (MPEs). However, MPEs themselves possess numerous drawbacks, particularly structural fragility. In this paper, we present a novel pencil-graphite electrode (PGE) fabricated from a regular HB#2 pencil. This PGE is a simple, disposable, extremely low-cost alternative to GCEs ($0.30 per PGE, vs. $190 + per GCE), and possesses the structural stability that MPEs lack. PGEs were characterized by square-wave voltammetry of ferricyanide, gallic acid, uric acid, dopamine, and several foodstuffs. In all cases, PGEs demonstrated sensitivities comparable or superior to those of the GCE and MPE (LOD = 5.62 × 10−4 M PGE, 4.80 × 10−4 M GCE, 2.93 × 10−4 M MPE). Signal areas and peak heights were typically four to ten times larger for the PGE relative to the GCE.
Open AccessDevelopment of a Novel, Low-Cost, Disposable Wooden Pencil Graphite Electrode for Use in the Determination of Antioxidants and Other Biological Compounds
The development of portable sensors that can be used outside the lab is an active area of research in the electroanalytical field. A major focus of such research is the development of low-cost electrodes for use in these sensors. Current electrodes, such as glassy-carbon electrodes (GCEs), are costly and require time-consuming preparation. Alternatives have been proposed, including mechanical pencil-lead electrodes (MPEs). However, MPEs themselves possess numerous drawbacks, particularly structural fragility. In this paper, we present a novel pencil-graphite electrode (PGE) fabricated from a regular HB#2 pencil. This PGE is a simple, disposable, extremely low-cost alternative to GCEs ($0.30 per PGE, vs. $190 + per GCE), and possesses the structural stability that MPEs lack. PGEs were characterized by square-wave voltammetry of ferricyanide, gallic acid, uric acid, dopamine, and several foodstuffs. In all cases, PGEs demonstrated sensitivities comparable or superior to those of the GCE and MPE (LOD = 5.62 × 10−4 M PGE, 4.80 × 10−4 M GCE, 2.93 × 10−4 M MPE). Signal areas and peak heights were typically four to ten times larger for the PGE relative to the GCE.