    Validation in diabetic rats of a fully automated insulin delivery system based on impulsive offset-free MPC control

    by Jhon E. Goez-Mora, Natalia Arbelaez-Córdoba, Norman Balcazar-Morales, Pablo S. Rivadeneira

    The development of an impulsive automated insulin delivery system (i-AiDS) for type 1 diabetes mellitus aims to provide real-time blood glucose regulation with minimal human intervention. This study presents the validation of an offset-free impulsive zone model predictive control strategy designed to cope with external disturbances such as meal intake and plant-model mismatch in a diabetic rat model. Fourteen male Wistar rats induced diabetes with streptozotocin were monitored using an continuous glucose monitoring and regulated by delivering insulin with a customized low-cost pump. After acquiring diabetes condition, the procedure for installing the devices in the rat is carried out. During the first day, manual insulin injections are made by the pump, the glucose response is recorded by the interface and an off-line parametric estimation is executed. Based on the parameters found, simulations are used for the first tuning of the controller and the estimator. During the second day, the parameters of the model and the control are tested and adjusted. Finally, on the third day, a 72-hour test of the impulsive begins in full autonomous mode. Results showed that the controller achieved an average of 83.4% of the time within the target range of 80-180 mg/dL, with no severe hypoglycemic or hyperglycemic events. The median absolute relative difference between model predictions and actual sensor data was 24.66%, indicating the presence of plant-model mismatch that was effectively handled by the controller. Peak hyperglycemic events reached 320 mg/dL, but were regulated within 50 minutes, while mild hypoglycemic events occurred in 3.62 ± 1.8 cases per subject. The study demonstrates the efficacy of the controller in managing unannounced carbohydrate intake and physiological disturbances in a real-world preclinical environment. These findings provide a foundation for future clinical trials, emphasizing the importance of in vivo validation of control strategies to refine the i-AiDS for human use. Improvements in model accuracy and dynamic parameter tuning could further enhance performance, particularly in longer experimental periods.

  • Open Access

    Study of insulin infusion in diabetic rats with an ultra‐low‐cost insulin pump for managing blood glucose levels

    by Jhon E. Goez‐Mora, Natalia Arbelaez‐Córdoba, Norman Balcazar‐Morales, Pablo S. Rivadeneira

    Introduction: This study assesses the accuracy of an ultra‐low‐cost insulin pump for regulating blood glucose, an essential component of the artificial pancreas. Objectives: The primary objective is to assess the accuracy of blood glucose regulation using an ultra‐low‐cost insulin pump compared with insulin injections. Methods: The study was conducted using 14 male Wistar rats aged 14 weeks, which were induced with diabetes through a streptozotocin procedure. The control group (seven subjects) was treated with subcutaneous insulin injections, and the study group (seven subjects) was treated with the experimental insulin pump. Results: Our findings reveal that the ultra‐low‐cost insulin pump performs comparably to insulin injections for glycemia regulation using standard clinical insulin treatment. The blood glucose records obtained by CGM indicate that trends in both methods correspond, with a glycemia median absolute relative difference of 6.1748 mg/dL and an interquartile range of 14.57 mg/dL. The response time to reach glucose levels between 70 and 180 mg/dL was around 55 min, testing different amounts of insulin units ranging from 0.09 to 2.06 U. Also, four obstruction cases were detected by the system in an average time of 3 s, showing compliance with the EN60601‐2‐24 standard. Conclusions: The in vivo experiments with diabetic rats and ultra‐low‐cost insulin pumps demonstrate that these prototypes can be used for glucose regulation in clinical trials while complying with the conditions of the EN60601‐2‐24 standard. Future work should focus on conducting insulin pump tests in a closed loop and a cybersecurity study to prevent any possible external attack.


  • Open Access

    Efficient AiDS Through Real-Time Insulin Sensitivity Estimation and Energy Management with Event-Triggered MPC

    by Jhon E. Goez-Mora, Pablo S. Rivadeneira

    This study focuses on developing a fully Automated Insulin Delivery System (AiDS) based on an event-triggered Model Predictive Control (ET-MPC) strategy aimed at individuals with type 1 diabetes mellitus (T1DM). The research addresses two key questions: (1) Can glycemic regulation be enhanced by integrating the recursive least squares (RLS) parameter estimator by dynamically adjusting the insulin sensitivity parameter, and (2) Can the embedded systems’ energy efficiency and operational autonomy by using an ET-MPC strategy? The ET-MPC strategy was enhanced with an RLS insulin sensitivity estimation. It was implemented within a hardware-in-the-loop (HIL) framework on a Raspberry Pi model 3B, integrated with a customized low-cost insulin pump and a battery driver. The virtual patient in the HIL emulation is the UVA/Padova simulator, which adds realistic physiological conditions to the emulation, such as highly nonlinear dynamics, measurement noise, parametric variations following the circadian cycle, and carbohydrate disturbances not announced to the controller. The prediction model was identified from 10 adults of the simulator and the states retrieved by the Kalman estimator. The study compared the performance of time-triggered (TT) and ET control strategies, both with and without the RLS insulin sensitivity estimator, over three-day HIL emulations. The integration of RLS improved glucose regulation under TT control, increasing the time within the target range from 75.97 to 91.08%. When the ET strategy is activated, it can reduce the control actions up to 60% while maintaining acceptable glycemic performance. Consequently, energy consumption was significantly reduced, with the device’s operational time extended up to threefold. However, higher thresholds in ET control compromised glucose control, highlighting the trade-off between energy savings and control performance. The RLS estimator enhances glycemic regulation, and the ET strategy achieves substantial energy savings, making the AiDS more efficient and portable. Future work should explore alternative estimation techniques for improved robustness and the real-time adaptation of the $$\epsilon$$ ϵ and $$\lambda$$ λ thresholds to optimize the trade-off between glycemic regulation and energy expenditure.


  • Didactic Strategy for Applied Learning of Control of State‐Space Systems Through Low‐Cost Electronic Modules

    by Pablo S. Rivadeneira, Jhon E. Candelo, Fredy Hoyos, Héctor A. Botero

    There is a growing need to apply advanced control techniques in industrial processes, and the state space provides modern tools for solving these requirements. Engineers and scientists must be prepared to offer solutions for the industry according to the advances, requiring proper knowledge acquired from their careers in Universities. However, courses in state‐space control theory in some educational institutions lack the practical experience to implement the controllers designed by students and only use simulations to enhance the understanding of this theory. Therefore, this paper proposes a didactic strategy for applied control learning within the framework of the state‐variable control course through individual, portable, and low‐cost modules. The method is based on the building of two types of electronic modules that allow students to perform a self‐practical laboratory. In addition, classroom action research is applied, considering a purposive sampling of students. The research also considers theoretical and practical interventions to explain to students the use of each electronic module and the requirements for performing the tests. An evaluation tool is designed to assess the knowledge of the students before and after the intervention. The results show how students improve their performance in control theory and achieve more advanced concepts of control implementation. The first test showed that of all students enrolled in the course, only 5% obtained good grades. After the first practical intervention, up to 49% of the students obtained good grades. The final practical intervention allowed more than 80% of the students to achieve high grades.


  • Exploring Oncolytic Measles Virotherapy for Cancer Tumor Reduction Using Linear MPC

    by Cristian Restrepo-Morales, Anet J. N. Anelone, Pablo S. Rivadeneira

  • Physical Benchmark for Evaluating Network Control Systems Under Cyber Attacks

    by Cristian Parada-Garcia, Cristian Restrepo-Morales, Pablo S. Rivadeneira