Stefan Buchmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Stefan Buchmann has a total of 121 co-authors. Here are the top co-authors by number of shared publications:
Andreas B. Imhoff
Klinikum Rechts der Isar, University of Munich
11 shared publicationsA.B. Imhoff
Technische Universität München
4 shared publicationsKnut Beitzel
Department of Orthopaedic Sports Medicine, Klinikum Rechts Der Isar, Technische Universität München, Munich, Germany
4 shared publications- Umile Giuseppe Longo
Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128 Rome, Italy
4 shared publications - Andreas B. Imhoff
Technical University of Munich
3 shared publications - Andreas B. Imhoff
Sports Orthopaedics, Orthopaedics and Traumatology Department of Orthopaedic Sports Medicine Technical University Hospital Rechts der Isar Munich Germany
3 shared publications
Latest Publications
- 16 December 2025
- Published by Springer Nature in Obere Extremität
- Vol. 21 (1) , 14-20
Postoperative Eigenübungen
- 16 December 2025
- Published by Springer Nature in Obere Extremität
- Vol. 21 (1) , 14-20
Postoperative Eigenübungen
- Open Access
- 1 December 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 506
Single versus double row suture anchor fixation for greater tuberosity fractures – a biomechanical study
Fractures of the humeral greater tuberosity (GT) are a frequent injury progressively treated with arthroscopic suture anchor repair. Yet, no biomechanical study has been performed comparing fixation strength of arthroscopic single- (SR) vs. double row (DR) fixation. Standardized fractures of the greater tuberosity were created in 12 fresh frozen proximal humeri. After random assignation to the SR or DR group the fixed humeri were tested applying cyclic loading to the supraspinatus and infraspinatus tendon. Load to failure and fragment displacement were assessed by means of an electrodynamic material testing machine using an optical tracking system. Load to failure values were higher in the DR group (649 N; ±176) than in the SR group (490 N; ±145) however without statistical significance (p = .12). In greater tuberosity displacement of 3–5 mm surgical treatment is recommended. The fixing constructs in this study did not reach displacement landmarks of 3 or 5 mm before construct failure as shown in previous studies. Thus the applied traction force (N) at 1 mm displacement was analyzed. In the SR group the load at 1 mm displacement was 277 N; ±46 compared to 260 N; ±62 in the DR group (p = .65). The results suggest that both techniques are viable options for refixation of greater tuberosity fractures. Level of Evidence: Laboratory study.
- 1 December 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 506
Open AccessSingle versus double row suture anchor fixation for greater tuberosity fractures – a biomechanical study
Fractures of the humeral greater tuberosity (GT) are a frequent injury progressively treated with arthroscopic suture anchor repair. Yet, no biomechanical study has been performed comparing fixation strength of arthroscopic single- (SR) vs. double row (DR) fixation. Standardized fractures of the greater tuberosity were created in 12 fresh frozen proximal humeri. After random assignation to the SR or DR group the fixed humeri were tested applying cyclic loading to the supraspinatus and infraspinatus tendon. Load to failure and fragment displacement were assessed by means of an electrodynamic material testing machine using an optical tracking system. Load to failure values were higher in the DR group (649 N; ±176) than in the SR group (490 N; ±145) however without statistical significance (p = .12). In greater tuberosity displacement of 3–5 mm surgical treatment is recommended. The fixing constructs in this study did not reach displacement landmarks of 3 or 5 mm before construct failure as shown in previous studies. Thus the applied traction force (N) at 1 mm displacement was analyzed. In the SR group the load at 1 mm displacement was 277 N; ±46 compared to 260 N; ±62 in the DR group (p = .65). The results suggest that both techniques are viable options for refixation of greater tuberosity fractures. Level of Evidence: Laboratory study.
- Open Access
- 25 May 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 1-11
No correlation between radiolucency and biomechanical stability of keeled and pegged glenoid components
The purpose of this study was to examine biomechanical properties and the degree of radiolucency of two cemented basic glenoid designs for total shoulder arthroplasty. Our hypothesis was that a component with increased micro-motion in the laboratory at time zero would also exhibit a greater amount of radiolucency in patients at a minimum of 2 years post total shoulder arthroplasty. Thirty cadaveric shoulders were divided into 2 groups (keel vs. peg). The glenoid components were first loaded with a single axial eccentric force of 196 N in all orientations and then with a transversal load of 49 N to simulate in vivo loads with abduction. Displacement of the glenoid component was determined with four different linear variable-differential transducers. In the second phase, 56 antero-posterior x-rays of 52 patients with either the same keeled (n = 24) or pegged (n = 32) glenoid component with a minimum of 24 months follow-up were evaluated for radiolucency. Biomechanically the pegged glenoid showed a significant increase in micro-motion during eccentric axial loading as well as during combined loading in the anterior, posterior, and inferior position as compared to the keeled glenoid (p < 0.05). In contrast all results were significant with greater radiolucency for the keeled glenoid component (p = 0.001). While the pegged component exhibited a greater amount of micro-motion during biomechanical testing, radiolucency was greater in patients with a keeled component. These findings provide support for both components from different perspectives and highlight the need for well-constructed studies to determine whether glenoid design has an effect on clinical outcome, because influences are multifactorial and biomechanical forces may not recreate forces seen in vivo.
- 25 May 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 1-11
Open AccessNo correlation between radiolucency and biomechanical stability of keeled and pegged glenoid components
The purpose of this study was to examine biomechanical properties and the degree of radiolucency of two cemented basic glenoid designs for total shoulder arthroplasty. Our hypothesis was that a component with increased micro-motion in the laboratory at time zero would also exhibit a greater amount of radiolucency in patients at a minimum of 2 years post total shoulder arthroplasty. Thirty cadaveric shoulders were divided into 2 groups (keel vs. peg). The glenoid components were first loaded with a single axial eccentric force of 196 N in all orientations and then with a transversal load of 49 N to simulate in vivo loads with abduction. Displacement of the glenoid component was determined with four different linear variable-differential transducers. In the second phase, 56 antero-posterior x-rays of 52 patients with either the same keeled (n = 24) or pegged (n = 32) glenoid component with a minimum of 24 months follow-up were evaluated for radiolucency. Biomechanically the pegged glenoid showed a significant increase in micro-motion during eccentric axial loading as well as during combined loading in the anterior, posterior, and inferior position as compared to the keeled glenoid (p < 0.05). In contrast all results were significant with greater radiolucency for the keeled glenoid component (p = 0.001). While the pegged component exhibited a greater amount of micro-motion during biomechanical testing, radiolucency was greater in patients with a keeled component. These findings provide support for both components from different perspectives and highlight the need for well-constructed studies to determine whether glenoid design has an effect on clinical outcome, because influences are multifactorial and biomechanical forces may not recreate forces seen in vivo.
- 30 July 2016
- Published by Springer Nature
- p. 989-996
Minimally Invasive Management of Syndesmotic Injuries
- 30 July 2016
- Published by Springer Nature
- p. 989-996
Minimally Invasive Management of Syndesmotic Injuries
- Open Access
- 5 April 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 1-7
Stem cells and bFGF in tendon healing: Effects of lentiviral gene transfer and long-term follow-up in a rat Achilles tendon defect model
The influence of stem cells and lentiviral expression of basic fibroblastic growth factor (bFGF) on tendon healing and remodelling was investigated in an in-vivo long-term (12 weeks) rat Achilles tendon defect model. In sixty male Lewis rats, complete tendon defects (2.4 mm) were created and either left untreated (PBS) or treated by injection of stem cells lentivirally expressing the enhanced green fluorescence marker gene eGFP (MSC-LV-eGFP) or basic fibroblast growth factor bFGF (MSC-LV-bFGF). Tendons were harvested after 12 weeks and underwent biomechanical and (immuno)-histological analysis. After 12 weeks the mean ultimate load to failure ratio (treated side to contralateral side) in biomechanical testing reached 97 % in the bFGF-group, 103 % in the eGFP-group and 112 % in the PBS-group. Also in the stiffness testing both MSC groups did not reach the results of the PBS group. Histologically, the MSC groups did not show better results than the control group. There were clusters of ossifications found in all groups. In immunohistology, only the staining collagen-type-I was strongly increased in both MSC groups in comparison to PBS control group. However, there were no significant differences in the (immuno)-histological results between both stem cell groups. The biomechanical and (immuno)-histological results did not show positive effects of the MSC groups on tendon remodelling in a long-term follow-up. Interestingly, in later stages stem cells had hardly any effects on biomechanical results. This study inspires a critical and reflected use of stem cells in tendon healing.
- 5 April 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 1-7
Open AccessStem cells and bFGF in tendon healing: Effects of lentiviral gene transfer and long-term follow-up in a rat Achilles tendon defect model
The influence of stem cells and lentiviral expression of basic fibroblastic growth factor (bFGF) on tendon healing and remodelling was investigated in an in-vivo long-term (12 weeks) rat Achilles tendon defect model. In sixty male Lewis rats, complete tendon defects (2.4 mm) were created and either left untreated (PBS) or treated by injection of stem cells lentivirally expressing the enhanced green fluorescence marker gene eGFP (MSC-LV-eGFP) or basic fibroblast growth factor bFGF (MSC-LV-bFGF). Tendons were harvested after 12 weeks and underwent biomechanical and (immuno)-histological analysis. After 12 weeks the mean ultimate load to failure ratio (treated side to contralateral side) in biomechanical testing reached 97 % in the bFGF-group, 103 % in the eGFP-group and 112 % in the PBS-group. Also in the stiffness testing both MSC groups did not reach the results of the PBS group. Histologically, the MSC groups did not show better results than the control group. There were clusters of ossifications found in all groups. In immunohistology, only the staining collagen-type-I was strongly increased in both MSC groups in comparison to PBS control group. However, there were no significant differences in the (immuno)-histological results between both stem cell groups. The biomechanical and (immuno)-histological results did not show positive effects of the MSC groups on tendon remodelling in a long-term follow-up. Interestingly, in later stages stem cells had hardly any effects on biomechanical results. This study inspires a critical and reflected use of stem cells in tendon healing.
- 2 March 2016
- Published by Springer Nature
- p. 1-8
Minimally Invasive Management of Syndesmotic Injuries
- Open Access
- 10 April 2015
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 16 (1) , 82
Growth factor release by vesicular phospholipid gels: in-vitro results and application for rotator cuff repair in a rat model
- 10 April 2015
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 16 (1) , 82
Open AccessGrowth factor release by vesicular phospholipid gels: in-vitro results and application for rotator cuff repair in a rat model
- 1 January 2015
- Published by Springer Nature
- p. 69-74
Cuff Disorders
- 29 October 2013
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 133 (12) , 1709
Erratum to: Clinical and radiographical results after double flip button stabilization of acute grade III and IV acromioclavicular joint separations
- 29 October 2013
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 133 (12) , 1709
Erratum to: Clinical and radiographical results after double flip button stabilization of acute grade III and IV acromioclavicular joint separations
- 23 October 2013
- Published by Springer Nature in Arthroskopie
- Vol. 26 (4) , 259-266
Infekt nach Arthroskopie
- 23 October 2013
- Published by Springer Nature in Arthroskopie
- Vol. 26 (4) , 259-266
Infekt nach Arthroskopie