Nafisa Solonina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nafisa Solonina has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Konstantin Suslov
Department of Power Supply and Electrical Engineering, Irkutsk National Research Technical University, 664074 Irkutsk, Russia
11 shared publications A. S. Smirnov
3 shared publications- Alexander Smirnov
Institute of Cytology and Genetics of the Siberian Branch of the Russian Academy of Sciences
3 shared publications A.S. Smirnov
Irkutsk State Technical University, Russia
2 shared publications- Vladimir S. Stepanov
Irkutsk State Technical University, Irkutsk, Russia
2 shared publications - Azat R. Akhmetshin
Kazan State Power Engineering University
1 shared publication
Latest Publications
- Open Access
- 8 June 2023
- Published by Kazan State Power Engineering University in Power engineering: research, equipment, technology
- Vol. 25 (2) , 71-83
Operational determination of the point of a short circuit in power lines
RELEVANCE. An urgent task is to improve the reliability and quality of power supply. Very often, failures in operation are caused by damage to overhead and cable lines. Traditionally, a fairly large number of violations occur in the share of electrical distribution networks. For the reliable functioning of power systems and uninterrupted power supply to consumers, it is necessary to identify and eliminate faults in a short time to minimize damage. Thus, a method for efficient, accurate and reliable fault location is needed for both utility companies and consumers. To solve this problem, it is necessary to quickly obtain information about the state of the distribution eclectic network. THE PURPOSE. Reducing the time to search for a fault location in electrical networks, reducing damage from downtime for undersupply of electricity by analyzing existing methods for determining the location of faults on a power transmission line and developing a method for its prompt detection in electrical networks. METHODS. The basis of this method is a preliminary theoretical calculation of short-circuit currents in various sections of a power line. Based on the values obtained as a result of the calculation, the measured values of the short-circuit currents are compared with these values, on the basis of which the location of the line damage is determined. An algorithm for searching the left and right boundaries of the short-circuit current value in an ordered array of statistical data has been developed. RESULTS. A method for quickly determining the location of a short circuit is proposed, which is based on the use of a data array of theoretically calculated short circuit currents. The presented algorithm is able to accurately determine the coordinates of the short circuit in electrical networks. CONCLUSION. The proposed method for determining the location of damage to the power line allows you to increase the efficiency of determining the point of a short circuit and thereby reduce the time to eliminate the accident, and therefore, economic losses from undersupply of electricity.The basis of this method is a preliminary theoretical calculation of short-circuit currents in various sections of a power line. Due to the subsequent comparison of the measured values of short-circuit currents with the values of the calculated values, the location of the damage to the power line is determined. The presented algorithm is designed to accurately determine thecoordinates of the short circuit location, which can significantly reduce the search time and improve the accuracy of determining the fault location in the range from 100 to 150 m, regardless of the length of the power line, which significantly reduces the time to search for damage at the same time as solving the problem of reducing downtime , as well as minimizing damage both for guaranteeing suppliers represented by electric grid companies, and for consumers represented by industrial and agricultural enterprises.
- 8 June 2023
- Published by Kazan State Power Engineering University in Power engineering: research, equipment, technology
- Vol. 25 (2) , 71-83
Open AccessOperational determination of the point of a short circuit in power lines
RELEVANCE. An urgent task is to improve the reliability and quality of power supply. Very often, failures in operation are caused by damage to overhead and cable lines. Traditionally, a fairly large number of violations occur in the share of electrical distribution networks. For the reliable functioning of power systems and uninterrupted power supply to consumers, it is necessary to identify and eliminate faults in a short time to minimize damage. Thus, a method for efficient, accurate and reliable fault location is needed for both utility companies and consumers. To solve this problem, it is necessary to quickly obtain information about the state of the distribution eclectic network. THE PURPOSE. Reducing the time to search for a fault location in electrical networks, reducing damage from downtime for undersupply of electricity by analyzing existing methods for determining the location of faults on a power transmission line and developing a method for its prompt detection in electrical networks. METHODS. The basis of this method is a preliminary theoretical calculation of short-circuit currents in various sections of a power line. Based on the values obtained as a result of the calculation, the measured values of the short-circuit currents are compared with these values, on the basis of which the location of the line damage is determined. An algorithm for searching the left and right boundaries of the short-circuit current value in an ordered array of statistical data has been developed. RESULTS. A method for quickly determining the location of a short circuit is proposed, which is based on the use of a data array of theoretically calculated short circuit currents. The presented algorithm is able to accurately determine the coordinates of the short circuit in electrical networks. CONCLUSION. The proposed method for determining the location of damage to the power line allows you to increase the efficiency of determining the point of a short circuit and thereby reduce the time to eliminate the accident, and therefore, economic losses from undersupply of electricity.The basis of this method is a preliminary theoretical calculation of short-circuit currents in various sections of a power line. Due to the subsequent comparison of the measured values of short-circuit currents with the values of the calculated values, the location of the damage to the power line is determined. The presented algorithm is designed to accurately determine thecoordinates of the short circuit location, which can significantly reduce the search time and improve the accuracy of determining the fault location in the range from 100 to 150 m, regardless of the length of the power line, which significantly reduces the time to search for damage at the same time as solving the problem of reducing downtime , as well as minimizing damage both for guaranteeing suppliers represented by electric grid companies, and for consumers represented by industrial and agricultural enterprises.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 260-264
A principle of power quality control in the intelligent distribution networks
There are some known methods for the improvement of power quality in the distribution and main networks. However, all these methods solve the power quality problem with a delay. The authors suggest using the available infrastructure of phasor measurement units that has been already used for monitoring the power system operation as a source of primary data at different points of the network. To this end, the sensors of instantaneous current and voltage values have been installed at the nodal points of the system (generators, distribution substations, consumer substations). This method involves the use of PMU infrastructure for continuous acquisition of data on instantaneous values of electrical currents and voltages. The smart meter proposed by the authors earlier is suggested as a primary tool for the measurement of the harmonic level and direction in different cutsets of the power systems. This procedure is performed online which allows continuous adjustment of electricity supply system to the operating conditions close to the optimal ones in terms of harmonic level in the supply voltage at the considered points of connection.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 260-264
A principle of power quality control in the intelligent distribution networks
There are some known methods for the improvement of power quality in the distribution and main networks. However, all these methods solve the power quality problem with a delay. The authors suggest using the available infrastructure of phasor measurement units that has been already used for monitoring the power system operation as a source of primary data at different points of the network. To this end, the sensors of instantaneous current and voltage values have been installed at the nodal points of the system (generators, distribution substations, consumer substations). This method involves the use of PMU infrastructure for continuous acquisition of data on instantaneous values of electrical currents and voltages. The smart meter proposed by the authors earlier is suggested as a primary tool for the measurement of the harmonic level and direction in different cutsets of the power systems. This procedure is performed online which allows continuous adjustment of electricity supply system to the operating conditions close to the optimal ones in terms of harmonic level in the supply voltage at the considered points of connection.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15406008,p. 517-520
Distributed power quality monitoring
One of the most important characteristics of the electric power system is its observability. The observability is essential not only for the power flows and power supply reliability indices, but also for the power quality indicators, particularly for the nonsinusoidality of supply voltage waveform. The wide use of power electronics components in intelligent electric power systems, which will increase in the future, leads to the occurrence of harmonic voltage and currents. Moreover, the electric power system facilities can be represented by both the sources and the consumers of high harmonics []. In this connection the assessment of impact of individual facilities on the power quality is a topical problem. The observability of electric power systems can be provided with the use of phasor measurement units (PMUs). The paper proposes a distributed power quality monitoring system based on the available PMU infrastructure to continuously control the level of high harmonics in different cutsets of the electric power system.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15406008,p. 517-520
Distributed power quality monitoring
One of the most important characteristics of the electric power system is its observability. The observability is essential not only for the power flows and power supply reliability indices, but also for the power quality indicators, particularly for the nonsinusoidality of supply voltage waveform. The wide use of power electronics components in intelligent electric power systems, which will increase in the future, leads to the occurrence of harmonic voltage and currents. Moreover, the electric power system facilities can be represented by both the sources and the consumers of high harmonics []. In this connection the assessment of impact of individual facilities on the power quality is a topical problem. The observability of electric power systems can be provided with the use of phasor measurement units (PMUs). The paper proposes a distributed power quality monitoring system based on the available PMU infrastructure to continuously control the level of high harmonics in different cutsets of the electric power system.
- 1 January 2014
- Published by INSTICC
- p. 63-67
PMU for Detection of Short-circuit Point in the Transmission Line
- 1 January 2014
- Published by INSTICC
- p. 63-67
PMU for Detection of Short-circuit Point in the Transmission Line
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 879-883
Improving the reliability of operation Microgrids
Ongoing change in the energy sector require ever more operational of obtaining and processing information about the current state of the power system. At the same time are placing demands on the accuracy and reliability of measurements of the circuit. This article focuses on the method of rapid determination of the coordinates of the short-circuit transmission line. The urgency of this problem for autonomous systems due to the fact that such systems emerge, usually in sparsely populated regions with harsh climates, low temperatures, wind, sleet, etc. It is in these circumstances, especially a high probability of breaks and short circuits. The solution to this problem is achieved by digital processing in real-time current information on currents and voltages of power lines immediately before and after a short circuit. High measuring accuracy is achieved by using a Rogowski coil as a transmitter voltage and current.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 879-883
Improving the reliability of operation Microgrids
Ongoing change in the energy sector require ever more operational of obtaining and processing information about the current state of the power system. At the same time are placing demands on the accuracy and reliability of measurements of the circuit. This article focuses on the method of rapid determination of the coordinates of the short-circuit transmission line. The urgency of this problem for autonomous systems due to the fact that such systems emerge, usually in sparsely populated regions with harsh climates, low temperatures, wind, sleet, etc. It is in these circumstances, especially a high probability of breaks and short circuits. The solution to this problem is achieved by digital processing in real-time current information on currents and voltages of power lines immediately before and after a short circuit. High measuring accuracy is achieved by using a Rogowski coil as a transmitter voltage and current.
- 1 January 2012
- Published by INSTICC
- p. 129-132
SMART GRID: MONITORING OF CABLE FAULT LOCATION
- 1 December 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Distributed filtering of high harmonics in Smart Grid
Currently great attention is paid to more efficient use of electric energy and considerable significance is attached to increase in power quality, in particular, by decreasing high harmonics in supply voltage. It seems reasonable to apply Smart Grid technologies, which imply continuous control and measurement of network parameters by the sensors of current, voltage, frequency, etc., and control of network operation on the basis of the data obtained. We suggest using smart meters of high harmonic energy and distributed filtering that provide minimum network resistance for the fundamental harmonic. The reactive components are used to tune the network. These are capacitances of network, inductances of transformers, capacitances of synchronous compensators and specially applied regulated inductances and capacitances. Information on network tuning to resonant conditions with fundamental harmonic comes from phase meters and high harmonic energy meters. The paper shows the necessity of measuring separately fundamental and high harmonic energy. Measurement of high harmonic energy and settlement of legal issues related to payment for this energy should encourage power supply companies and consumers to take technical and organizational measures to decrease high harmonic level in the network. These measures should lead to the improvement of the supply network voltage waveform which will enhance the efficiency of electric energy use by consumers.
- 1 December 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Distributed filtering of high harmonics in Smart Grid
Currently great attention is paid to more efficient use of electric energy and considerable significance is attached to increase in power quality, in particular, by decreasing high harmonics in supply voltage. It seems reasonable to apply Smart Grid technologies, which imply continuous control and measurement of network parameters by the sensors of current, voltage, frequency, etc., and control of network operation on the basis of the data obtained. We suggest using smart meters of high harmonic energy and distributed filtering that provide minimum network resistance for the fundamental harmonic. The reactive components are used to tune the network. These are capacitances of network, inductances of transformers, capacitances of synchronous compensators and specially applied regulated inductances and capacitances. Information on network tuning to resonant conditions with fundamental harmonic comes from phase meters and high harmonic energy meters. The paper shows the necessity of measuring separately fundamental and high harmonic energy. Measurement of high harmonic energy and settlement of legal issues related to payment for this energy should encourage power supply companies and consumers to take technical and organizational measures to decrease high harmonic level in the network. These measures should lead to the improvement of the supply network voltage waveform which will enhance the efficiency of electric energy use by consumers.
- 1 December 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Smart Grid: A new way of receiving primary information on electric power system state
The ultimate goal of implementing Smart Grid technologies is to achieve high reliability and economic efficiency of electric energy transmission and distribution to consumers. This can be done only when control centers of electric networks are provided with complete information. Installation of smart meters is a necessary but insufficient condition for information support. There is a need for highly accurate primary data transducers, with linear transfer function, to provide information on the most important system parameters. Traditionally the induction-type instrument transformers equipped with ferromagnetic core were used as primary transducers. The authors suggest for these purposes Rogowski coil with non-ferromagnetic core. An indispensable condition for successful operation of the networks is their good physical condition. Even with high quality relay protection short circuits can occur in the lines. For the line to be quickly restored it is necessary to detect the place of fault. This can also be done by using Rogowski coil along with the cutting-edge information technologies. The two areas of Rogowski coil application that are suggested by the authors allow one to improve the quality of information support to the control centers and enhance their technical level.
- 1 December 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Smart Grid: A new way of receiving primary information on electric power system state
The ultimate goal of implementing Smart Grid technologies is to achieve high reliability and economic efficiency of electric energy transmission and distribution to consumers. This can be done only when control centers of electric networks are provided with complete information. Installation of smart meters is a necessary but insufficient condition for information support. There is a need for highly accurate primary data transducers, with linear transfer function, to provide information on the most important system parameters. Traditionally the induction-type instrument transformers equipped with ferromagnetic core were used as primary transducers. The authors suggest for these purposes Rogowski coil with non-ferromagnetic core. An indispensable condition for successful operation of the networks is their good physical condition. Even with high quality relay protection short circuits can occur in the lines. For the line to be quickly restored it is necessary to detect the place of fault. This can also be done by using Rogowski coil along with the cutting-edge information technologies. The two areas of Rogowski coil application that are suggested by the authors allow one to improve the quality of information support to the control centers and enhance their technical level.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21506647,p. 1-4
Distributed filtering of high harmonics in microgrids
Currently great attention is paid to more efficient use of electric energy and considerable significance is attached to increase in power quality, in particular, by decreasing high harmonics in supply voltage. It seems reasonable to apply Smart Grid technologies, which imply continuous control and measurement of network parameters by the sensors of current, voltage, frequency, etc., and control of network operation on the basis of the data obtained. We suggest using smart meters of high harmonic energy and distributed filtering that provide minimum network resistance for the fundamental harmonic. The reactive components are used to tune the network. These are capacitances of network, inductances of transformers, capacitances of synchronous compensators and specially applied regulated inductances and capacitances. Information on network tuning to resonant conditions with fundamental harmonic comes from phase meters and high harmonic energy meters. The paper shows the necessity of measuring separately fundamental and high harmonic energy. Measurement of high harmonic energy and settlement of legal issues related to payment for this energy should encourage power supply companies and consumers to take technical and organizational measures to decrease high harmonic level in the network. These measures should lead to the improvement of the supply network voltage waveform which will enhance the efficiency of electric energy use by consumers.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21506647,p. 1-4
Distributed filtering of high harmonics in microgrids
Currently great attention is paid to more efficient use of electric energy and considerable significance is attached to increase in power quality, in particular, by decreasing high harmonics in supply voltage. It seems reasonable to apply Smart Grid technologies, which imply continuous control and measurement of network parameters by the sensors of current, voltage, frequency, etc., and control of network operation on the basis of the data obtained. We suggest using smart meters of high harmonic energy and distributed filtering that provide minimum network resistance for the fundamental harmonic. The reactive components are used to tune the network. These are capacitances of network, inductances of transformers, capacitances of synchronous compensators and specially applied regulated inductances and capacitances. Information on network tuning to resonant conditions with fundamental harmonic comes from phase meters and high harmonic energy meters. The paper shows the necessity of measuring separately fundamental and high harmonic energy. Measurement of high harmonic energy and settlement of legal issues related to payment for this energy should encourage power supply companies and consumers to take technical and organizational measures to decrease high harmonic level in the network. These measures should lead to the improvement of the supply network voltage waveform which will enhance the efficiency of electric energy use by consumers.
- 1 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21555516,p. 1-5
Smart meters for distributed filtering of high harmonics in Smart Grid
Currently great attention is paid to more efficient use of electric energy and considerable significance is attached to increase in power quality, in particular, by decreasing high harmonics in supply voltage. It seems reasonable to apply Smart Grid technologies, which imply continuous control and measurement of network parameters by the sensors of current, voltage, frequency, etc., and control of network operation on the basis of the data obtained. We suggest using smart meters of high harmonic energy and distributed filtering that provide minimum network resistance for the fundamental harmonic. The reactive components are used to tune the network These are capacitances of network, inductances of transformers, capacitances of synchronous compensators and specially applied regulated inductances and capacitances. Information on network tuning to resonant conditions with fundamental harmonic comes from phase meters and high harmonic energy meters. The paper shows the necessity of measuring separately fundamental and high harmonic energy. Measurement of high harmonic energy and settlement of legal issues related to payment for this energy should encourage power supply companies and consumers to take technical and organizational measures to decrease high harmonic level in the network. These measures should lead to the improvement of the supply network voltage waveform which will enhance the efficiency of electric energy use by consumers.
- 1 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21555516,p. 1-5
Smart meters for distributed filtering of high harmonics in Smart Grid
Currently great attention is paid to more efficient use of electric energy and considerable significance is attached to increase in power quality, in particular, by decreasing high harmonics in supply voltage. It seems reasonable to apply Smart Grid technologies, which imply continuous control and measurement of network parameters by the sensors of current, voltage, frequency, etc., and control of network operation on the basis of the data obtained. We suggest using smart meters of high harmonic energy and distributed filtering that provide minimum network resistance for the fundamental harmonic. The reactive components are used to tune the network These are capacitances of network, inductances of transformers, capacitances of synchronous compensators and specially applied regulated inductances and capacitances. Information on network tuning to resonant conditions with fundamental harmonic comes from phase meters and high harmonic energy meters. The paper shows the necessity of measuring separately fundamental and high harmonic energy. Measurement of high harmonic energy and settlement of legal issues related to payment for this energy should encourage power supply companies and consumers to take technical and organizational measures to decrease high harmonic level in the network. These measures should lead to the improvement of the supply network voltage waveform which will enhance the efficiency of electric energy use by consumers.