STStephen Thompson

Stephen Thompson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stephen Thompson has a total of 122 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Serious Game to Study Reduced Field of View in Keyhole Surgery: Development and Experimental Study

    by Phoebe Whitley, Connor Creasey, Matthew J Clarkson, Stephen Thompson

    Background: During keyhole surgery, the surgeon is required to perform highly demanding tasks while only being able to see part of the patient’s anatomy. This limited field of view is widely cited as a key limitation of the procedure, and many computational methods have been proposed to overcome it. However, the precise effects of a limited field of view on task performance remain unknown due to the lack of tools to study these effects effectively. Objective: This paper describes our work on developing a serious game with 2 objectives: (1) to create an engaging game that communicates some of the challenges of keyhole surgery, and (2) to test the effect of a limited field of view on task performance. The development of a serious game that can be played by a wide range of participants will enable us to gather quantitative data on the effects of the reduced field of view on task performance. These data can inform the future development of technologies to help surgeons reduce the impact of a limited field of view on clinical outcomes for patients. The game is open source and may be adapted and used by other researchers to study related problems. Methods: We implemented an open-source serious game in JavaScript, inspired by the surgical task of selectively cauterizing blood vessels during twin-to-twin transfusion surgery. During the game, the player is required to identify and cut the correct blood vessel under different fields of view and varying levels of vascular complexity. We conducted a quantitative analysis of task performance time under different conditions and a formative analysis of the game using participant questionnaires. Results: We recruited 25 players to test the game and recorded their task performance time, accuracy, and qualitative metrics. Reducing the field of view resulted in participants taking significantly longer (P<.001) to perform otherwise identical tasks (mean 6.4 seconds, 95% CI 5.0-7.8 seconds vs mean 13.6 seconds, 95% CI 10.3-16.9 seconds). Participants found the game engaging and agreed that it enhanced their understanding of the limited field of view during keyhole surgery. Conclusions: We recruited 25 players to test the game and recorded their task performance time, accuracy, and qualitative metrics. Reducing the field of view resulted in participants taking statistically significantly longer (16.4 vs 9.8 seconds; P=.05) to perform otherwise identical tasks. Participants found the game engaging and agreed that it enhanced their understanding of the limited field of view during keyhole surgery.


  • Open Access

    Development and Assessment of a Serious Game to Study Reduced Field of View in Keyhole Surgery (Preprint)

    by Phoebe Whitley, Matthew J Clarkson, Stephen Thompson

    BACKGROUND During keyhole surgery the surgeon is required to perform highly demanding tasks whilst only able to see part of the patient's anatomy. This limited field of view is very widely cited as a key limitation of keyhole surgery and many computational methods to overcome limited field of view have been proposed. However, the precise effects of limited field of view on task performance remain unknown due to a lack of tools to effectively study the effects of limited field of view. OBJECTIVE This paper describes our work on developing a serious game to test the effect of limited field of view on task performance. The development of a serious game that can be played by a wide range of participants will enable to gather quantitative data on the effects of reduced field of view on task performance. These data can inform future development of technologies to aid the surgeon in reducing the impact of limited field of view on clinical outcomes for the patient. As the game is fully opensource it may also be adapted and used by other researchers to study related problems. METHODS We implemented an opensource serious game in JavaScript, inspired by the surgical task of selectively cauterising blood vessels during twin to twin transfusion surgery. During the game the player is required to identify and cut the correct blood vessel under different fields of view, and with different levels of vascular complexity. We performed a quantitative analysis of task performance time under different conditions and a formative analysis of the game using participant questionnaires. RESULTS We recruited 25 players to test the game and recorded their task performance time, accuracy, and qualitative metrics. Reducing the field of view resulting in participants taking statistically significantly longer (16.4 vs 9.8 seconds, p=0.05) to perform otherwise identical tasks. Participants found the game engaging and agreed that the game enhanced their understanding of limited field of view during keyhole surgery. CONCLUSIONS We recruited 25 players to test the game and recorded their task performance time, accuracy, and qualitative metrics. Reducing the field of view resulting in participants taking statistically significantly longer (16.4 vs 9.8 seconds, p=0.05) to perform otherwise identical tasks. Participants found the game engaging and agreed that the game enhanced their understanding of limited field of view during keyhole surgery. CLINICALTRIAL This paper does not include an RCT.

  • Open Access

    Enhanced Surgeons: Understanding the Design of Augmented Reality Instructions for Keyhole Surgery

    by Christoph Davis, Soojeong Yoo, Matthew J. Clarkson, Stephen Thompson

    It is important to understand how to design AR content for surgical contexts to mitigate the risk of distracting the surgeons. In this work, we test information overlays for AR guidance during keyhole surgery. We performed a preliminary evaluation of a prototype, focusing on the effects of colour, opacity, and information representation. Our work contributes insights into the design of AR guidance in surgery settings and a foundation for future research on visualisation design for surgical AR.


  • Open Access

    CMakeCatchTemplate: A C++ template project

    by Thomas Dowrick, Mian Ahmad, Stephen Thompson, James Hetherington, Jonathan Cooper, Matt Clarkson

    CMakeCatchTemplate (https://github.com/MattClarkson/CMakeCatchTemplate) is a project to provide a starting structure for C++ projects configured with CMake, that can be customised to work in a variety of scenarios, allowing developers to deploy new algorithms to users in a shorter timeframe. Main features include a SuperBuild to build optional dependencies; unit tests using Catch; support for CUDA, OpenMP and MPI; examples of command line and GUI applications; Doxygen integration; Continuous Integration templates and support for building/deploying Python modules.

  • Open Access

    Comparison of manual and semi-automatic registration in augmented reality image-guided liver surgery: a clinical feasibility study

    by C. Schneider, S. Thompson, J. Totz, Y. Song, M. Allam, M. H. Sodergren, A. E. Desjardins, D. Barratt, S. Ourselin, K. Gurusamy, et al.

    Background: The laparoscopic approach to liver resection may reduce morbidity and hospital stay. However, uptake has been slow due to concerns about patient safety and oncological radicality. Image guidance systems may improve patient safety by enabling 3D visualisation of critical intra- and extrahepatic structures. Current systems suffer from non-intuitive visualisation and a complicated setup process. A novel image guidance system (SmartLiver), offering augmented reality visualisation and semi-automatic registration has been developed to address these issues. A clinical feasibility study evaluated the performance and usability of SmartLiver with either manual or semi-automatic registration. Methods: Intraoperative image guidance data were recorded and analysed in patients undergoing laparoscopic liver resection or cancer staging. Stereoscopic surface reconstruction and iterative closest point matching facilitated semi-automatic registration. The primary endpoint was defined as successful registration as determined by the operating surgeon. Secondary endpoints were system usability as assessed by a surgeon questionnaire and comparison of manual vs. semi-automatic registration accuracy. Since SmartLiver is still in development no attempt was made to evaluate its impact on perioperative outcomes. Results: The primary endpoint was achieved in 16 out of 18 patients. Initially semi-automatic registration failed because the IGS could not distinguish the liver surface from surrounding structures. Implementation of a deep learning algorithm enabled the IGS to overcome this issue and facilitate semi-automatic registration. Mean registration accuracy was 10.9 ± 4.2 mm (manual) vs. 13.9 ± 4.4 mm (semi-automatic) (Mean difference − 3 mm; p = 0.158). Surgeon feedback was positive about IGS handling and improved intraoperative orientation but also highlighted the need for a simpler setup process and better integration with laparoscopic ultrasound. Conclusion: The technical feasibility of using SmartLiver intraoperatively has been demonstrated. With further improvements semi-automatic registration may enhance user friendliness and workflow of SmartLiver. Manual and semi-automatic registration accuracy were comparable but evaluation on a larger patient cohort is required to confirm these findings.


  • Open Access

    SciKit-Surgery: compact libraries for surgical navigation

    by Stephen Thompson, Thomas Dowrick, Mian Ahmad, Goufang Xiao, Bongjin Koo, Ester Bonmati, Kim Kahl, Matthew J. Clarkson

    Purpose: This paper introduces the SciKit-Surgery libraries, designed to enable rapid development of clinical applications for image-guided interventions. SciKit-Surgery implements a family of compact, orthogonal, libraries accompanied by robust testing, documentation, and quality control. SciKit-Surgery libraries can be rapidly assembled into testable clinical applications and subsequently translated to production software without the need for software reimplementation. The aim is to support translation from single surgeon trials to multicentre trials in under 2 years. Methods: At the time of publication, there were 13 SciKit-Surgery libraries provide functionality for visualisation and augmented reality in surgery, together with hardware interfaces for video, tracking, and ultrasound sources. The libraries are stand-alone, open source, and provide Python interfaces. This design approach enables fast development of robust applications and subsequent translation. The paper compares the libraries with existing platforms and uses two example applications to show how SciKit-Surgery libraries can be used in practice. Results: Using the number of lines of code and the occurrence of cross-dependencies as proxy measurements of code complexity, two example applications using SciKit-Surgery libraries are analysed. The SciKit-Surgery libraries demonstrate ability to support rapid development of testable clinical applications. By maintaining stricter orthogonality between libraries, the number, and complexity of dependencies can be reduced. The SciKit-Surgery libraries also demonstrate the potential to support wider dissemination of novel research. Conclusion: The SciKit-Surgery libraries utilise the modularity of the Python language and the standard data types of the NumPy package to provide an easy-to-use, well-tested, and extensible set of tools for the development of applications for image-guided interventions. The example application built on SciKit-Surgery has a simpler dependency structure than the same application built using a monolithic platform, making ongoing clinical translation more feasible.


  • Open Access

    SnappySonic: An Ultrasound Acquisition Replay Simulator

    by Stephen Thompson, Thomas Dowrick, Goufang Xiao, João Ramalhinho, Maria Robu, Mian Ahmad, Dan Taylor, Matthew J. Clarkson

    SnappySonic provides an ultrasound acquisition replay simulator designed for public engagement and training. It provides a simple interface to allow users to experience ultrasound acquisition without the need for specialist hardware or acoustically compatible phantoms. The software is implemented in Python, built on top of a set of open source Python modules targeted at surgical innovation. The library has high potential for reuse, most obviously for those who want to simulate ultrasound acquisition, but it could also be used as a user interface for displaying high dimensional images or video data.


  • 315 The Use of High Frequency Ultrasound to Monitor Treatment of Hypertrophic Burn Scars with Fractionated Ablative CO2 Laser Therapy

    by R George, H Siordia, J Buhler, S Thompson, L Cancio, R Chan

    Treatment of hypertrophic burn scars using fractionated ablative CO2 laser is increasingly adopted by burn centers and burn scar treatment facilities. While high level, definitive evidence for this type of therapy is still lacking, fractionated ablative CO2 laser is purported to improve the symptoms of hypertrophic scarring by decreasing scar stiffness, irregularity and thickness. Several objective measures are available as research tools to monitor treatment progression though few of these metrics are commonly used in a non-research setting. In this study, we seek to demonstrate that ultrasound scar thickness can be feasibly integrated into the clinical treatment of hypertrophic burn scars to monitor patient response. As part of a process improvement effort, patients undergoing CO2 laser therapy were prospectively followed using ultrasound determination of scar depth. A deep FX handpiece of the CO2 laser was used for the therapy. One area of a symptomatic hypertrophic burn scar was selected on each patient for evaluation by ultrasound. Scar thickness was measured prior to the initial treatment as well as prior to each subsequent treatment. Hypertrophic burn scars with age of injury from less than 1 year to 7 years (mean 646 days) were prospectively studied on 11 patients. A total of 15 sessions were performed during the study period (mean 1.4 sessions/patient). One patient underwent three treatments after initial evaluation; two patients underwent two treatments; and eight patients underwent one treatment. Scar thickness decrease of 25% (95% CI, 7.3%-42.5%) and 30% after one and two treatments were noted, respectively. A correlation was noted between initial scar thickness and percentage decrease, where a 48% decrease in scar thickness can be expected for every 1mm of initial scar depth. CO2 laser therapy is fast becoming a standard in the treatment of hypertrophic burn scars, though questions remain regarding its efficacy. Objective measurements to follow patients’ response to therapy will be important to the patient and his/her provider, but also to third-party payers in deciding whether additional treatment sessions are medically necessary. In this limited study, the use of CO2 laser therapy demonstrated decreases in scar thickness. Data from a randomized, controlled study is still needed to demonstrate this effect, though continuation of this uncontrolled effort will still add evidence to support CO2 laser use in each individual patient. The use of an ultrasound to measure scar thickness after treatment with CO2 laser therapy is reproducible, readily available and can feasibly be integrated into a laser clinic to monitor patient response.


  • Open Access

    Electromagnetic tracking in image‐guided laparoscopic surgery: Comparison with optical tracking and feasibility study of a combined laparoscope and laparoscopic ultrasound system

    by Guofang Xiao, Ester Bonmati, Stephen Thompson, Joe Evans, John Hipwell, Daniil Nikitichev, Kurinchi Gurusamy, S′Ebastien Ourselin, David J. Hawkes, Brian Davidson, et al.

    Purpose: In image‐guided laparoscopy, optical tracking is commonly employed, but electromagnetic (EM) systems have been proposed in the literature. In this paper, we provide a thorough comparison of EM and optical tracking systems for use in image‐guided laparoscopic surgery and a feasibility study of a combined, EM‐tracked laparoscope and laparoscopic ultrasound (LUS) image guidance system.Methods: We first assess the tracking accuracy of a laparoscope with two optical trackers tracking retroreflective markers mounted on the shaft and an EM tracker with the sensor embedded at the proximal end, using a standard evaluation plate. We then use a stylus to test the precision of position measurement and accuracy of distance measurement of the trackers. Finally, we assess the accuracy of an image guidance system comprised of an EM‐tracked laparoscope and an EM‐tracked LUS probe.Results: In the experiment using a standard evaluation plate, the two optical trackers show less jitter in position and orientation measurement than the EM tracker. Also, the optical trackers demonstrate better consistency of orientation measurement within the test volume. However, their accuracy of measuring relative positions decreases significantly with longer distances whereas the EM tracker's performance is stable; at 50 mm distance, the RMS errors for the two optical trackers are 0.210 and 0.233 mm, respectively, and it is 0.214 mm for the EM tracker; at 250 mm distance, the RMS errors for the two optical trackers become 1.031 and 1.178 mm, respectively, while it is 0.367 mm for the EM tracker. In the experiment using the stylus, the two optical trackers have RMS errors of 1.278 and 1.555 mm in localizing the stylus tip, and it is 1.117 mm for the EM tracker. Our prototype of a combined, EM‐tracked laparoscope and LUS system using representative calibration methods showed a RMS point localization error of 3.0 mm for the laparoscope and 1.3 mm for the LUS probe, the lager error of the former being predominantly due to the triangulation error when using a narrow‐baseline stereo laparoscope.Conclusions: The errors incurred by optical trackers, due to the lever‐arm effect and variation in tracking accuracy in the depth direction, would make EM‐tracked solutions preferable if the EM sensor is placed at the proximal end of the laparoscope.


  • Open Access

    A pre-operative planning framework for global registration of laparoscopic ultrasound to CT images

    by João Ramalhinho, Maria R. Robu, Stephen Thompson, Kurinchi Gurusamy, Brian Davidson, David Hawkes, Dean Barratt, Matthew J. Clarkson

    Purpose Laparoscopic ultrasound (LUS) enhances the safety of laparoscopic liver resection by enabling real-time imaging of internal structures such as vessels. However, LUS probes can be difficult to use, and many tumours are iso-echoic and hence are not visible. Registration of LUS to a pre-operative CT or MR scan has been proposed as a method of image guidance. However, the field of view of the probe is very small compared to the whole liver, making the registration task challenging and dependent on a very accurate initialisation. Methods We propose the use of a subject-specific planning framework that provides information on which anatomical liver regions it is possible to acquire vascular data that is unique enough for a globally optimal initial registration. Vessel-based rigid registration on different areas of the pre-operative CT vascular tree is used in order to evaluate predicted accuracy and reliability. Results The planning framework is tested on one porcine subject where we have taken 5 independent sweeps of LUS data from different sections of the liver. Target registration error of vessel branching points was used to measure accuracy. Global registration based on vessel centrelines is applied to the 5 datasets. In 3 out of 5 cases registration is successful and in agreement with the planning. Further tests with a CT scan under abdominal insufflation show that the framework can provide valuable information in all of the 5 cases. Conclusions We have introduced a planning framework that can guide the surgeon on how much LUS data to collect in order to provide a reliable globally unique registration without the need for an initial manual alignment. This could potentially improve the usability of these methods in clinic.