XHXiaolin Huang

Xiaolin Huang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaolin Huang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Self-Similarity Prior Distillation for Unsupervised Remote Physiological Measurement

    by Xinyu Zhang, Weiyu Sun, Hao Lu, Ying Chen, Yun Ge, Xiaolin Huang, Jie Yuan, Yingcong Chen

    Remote photoplethysmography (rPPG) is a non-invasive technique that aims to capture subtle variations in facial pixels caused by changes in blood volume resulting from cardiac activities. Most existing unsupervised methods for rPPG tasks focus on the contrastive learning between samples while neglecting the inherent self-similarity prior in physiological signals. In this paper, we propose a Self-Similarity Prior Distillation (SSPD) framework for unsupervised rPPG estimation, which capitalizes on the intrinsic temporal self-similarity of cardiac activities. Specifically, we first introduce a physical-prior embedded augmentation technique to mitigate the effect of various types of noise. Then, we tailor a self-similarity-aware network to disentangle more reliable self-similar physiological features. Finally, we develop a hierarchical self-distillation paradigm for self-similarity-aware learning and rPPG signal decoupling. Comprehensive experiments demonstrate that the unsupervised SSPD framework achieves comparable or even superior performance compared to the state-of-the-art supervised methods. Meanwhile, SSPD has the lowest inference time and computation cost among end-to-end models.


  • Open Access

    Resolve Domain Conflicts for Generalizable Remote Physiological Measurement

    by Weiyu Sun, Xinyu Zhang, Hao Lu, Ying Chen, Yun Ge, Xiaolin Huang, Jie Yuan, Yingcong Chen


  • Open Access

    An entropy-based method to measure phase-locking between LFP and spikes

    by Xing-Yan Dang, Han-Ting Xu, Xin-Yu Bao, Yun-Yong Xie, Jing-Ning Zhu, Xiao-Yang Zhang, Xiao-Lin Huang

    Phase-locking between local field potential and spikes has been widely investigated through neurophysiological analysis. Two indices most frequently adopted traditionally include the mean resultant length and p of the Rayleigh test. However, the traditional method is found less reliable for cases with substantial sample sizes or with bimodal distribution. In this article, K we propose an entropy-based method to detect and measure phase-locking. Simulation results prove that the method can be effectively applied to cases with a relatively large sample size and it can effectively detect phase-locking even under bimodal conditions with two peaks of opposite phases. Furthermore, we propose thresholds to help measure the intensity of spike field phase-locking. We also apply the proposed method to our experimental data and find phase locking with two opposite phases, which would be left out in traditional phase-locking analysis.

  • Open Access

    Classification for Memory Activities: Experiments and EEG Analysis Based on Networks Constructed via Phase-Locking Value

    by Jing Xi, Xiao-Lin Huang, Xing-Yan Dang, Bin-Bin Ge, Ying Chen, Yun Ge

    Electroencephalogram (EEG) plays a crucial role in the study of working memory, which involves the complex coordination of brain regions. In this research, we designed and conducted series of experiments of memory with various memory loads or target forms and collected behavioral data as well as 32-lead EEG simultaneously. Combined with behavioral data analysis, we segmented EEG into slices; then, we calculated phase-locking value (PLV) of Gamma rhythms between every two leads, conducted binarization, constructed brain function network, and extracted three network characteristics of node degree, local clustering coefficient, and betweenness centrality. Finally, we inputted these network characteristics of all leads into support vector machines (SVM) for classification and obtained decent performances; i.e., all classification accuracies are greater than 0.78 on an independent test set. Particularly, PLV application was restricted to the narrow-band signals, and rare successful application to EEG Gamma rhythm, defined as wide as 30-100 Hz, had been reported. In order to address this limitation, we adopted simulation on band-pass filtered noise with the same frequency band as Gamma to help determine the PLV binarizing threshold. It turns out that network characteristics based on binarized PLV have the ability to distinguish the presence or absence of memory, as well as the intensity of the mental workload at the moment of memory. This work sheds a light upon phase-locking investigation between relatively wide-band signals, as well as memory research via EEG.


  • Open Access

    Intensive Care Unit False Alarm Identification Based on Convolution Neural Network

    by Qiang Yu, Cheng Wang, Jing Xi, Ying Chen, Weifeng Li, Yun Ge, Xiaolin Huang

    In the intensive care unit(ICU), excessive false alarms burden medical staff greatly, and cause a waste of medical resources as well. In order to alleviate false alarming in ICU, we constructed classification models based on convolutional neural network, which can directly deal with time series and avoid manually extracting features. Combining with grouping strategy, we tried two basic network structures, i.e. deep group convolutional neural network(DGCN) and embedded deep group convolutional network(EDGCN). After that, based on EDGCN, which was proved better, ensemble networks were constructed to elevate the performance further. Considering of the limited sample size, various data expansions were also tried. For comparison, we used a widely adopted index `Score', which is defined as 100×(TP+TN)/(TP+TN+FP + 5×FN), as performance evaluation. Finally, we tested our model in the online sandbox, and got a score of 80.68. Although it is slightly lower than the best scores that have been reported, our models are end-to-end, which means the original time series can be automatically mapped into a binary output, without manual feature extraction. In addition, the innovative adoption of group convolution makes full use of information from multi-channel signals. Besides, this work provides ideas for relating network parameter selection with physiological or physical natures of signals. In the end, after further discussion, we also proposed potential elevation solutions.


  • Open Access

    ICU False Alarm Identification Based on Convolution Neural Network

    by Qiang Yu, Cheng Wang, Jing Xi, Ying Chen, Weifeng Li, Yun Ge, Xiaolin Huang

    Background: In intensive care unit(ICU), excessive false alarms burden medical staff greatly, and cause medical resource waste as well. In order to alleviate false alarms in ICU, we constructed models for classification using convolutional neural networks, which can deal directly with time series and avoid extracting features manually. Results: Combining with grouping strategy, we tried two basic network structures, i.e. DGCN and EDGCN. After that, based on EDGCN, which was proved better, ensembling networks were also constructed to elevate the performance further. Considering of the limited sample size, different data expansions were also experimented. Finally, we tested our model in the online sandbox, and got a score of 78.14. Conclusions: Although the performance is slightly lower than the best scores that have been reported, our models are end-to-end, through which the original time series can be automatically mapped into a binary output, without manually feature extraction. In addition, our method innovatively uses grouped convolution to make full use of the information in multi-channel signals. In the end, we also discussed the potential solutions to further elevate performances.

  • Open Access

    Common Interferences Removal from Dense Multichannel EEG Using Independent Component Decomposition

    by Weifeng Li, Yuxiaotong Shen, Jie Zhang, Xiaolin Huang, Ying Chen, Yun Ge

    To improve the spatial resolution, dense multichannel electroencephalogram with more than 32 leads has gained more and more applications. However, strong common interference will not only conceal the weak components generated from the specific isolated neural source, but also lead to severe spurious correlation between different brain regions, which results in great distortion on brain connectivity or brain network analysis. Starting from the fast independent component analysis algorithm, we first derive the mixing matrix of independent source components based on the baseline signals prior to tasks. Then, we identify the common interferences as those components whose mixing vectors span the minimum angles with respect to the unitary vector. By assuming that both the common interferences and their corresponding mixing vectors stay consistent during the entire experiment, we apply the demixing and mixing matrix to the task signals and remove the inferred common interferences. Subsequently, we validate the method using simulation. Finally, the index of global coherence is calculated for validation. It turns out that the proposed method can successfully remove the common interferences so that the prominent coherence of mu rhythms in motor imagery tasks is unmasked. The proposed method can gain wide applications because it reveals the true correlation between the local sources in spite of the low signal-to-noise ratio.


  • Open Access

    Nearest Neighbor Method to Estimate Internal Target for Real-Time Tumor Tracking

    by Jie Zhang, Xiaolin Huang, Yuxiaotong Shen, Ying Chen, Jing Cai, Yun Ge

    Purpose: This work proposed a nearest neighbor estimation method to track the respiration-induced tumor motion. Methods: Based on the simultaneously collected motion traces of external surrogate and internal target during the modeling phase prior to treatment, we first obtain the nearest neighbors of the current surrogate in external space. Subsequently, the concurrent targets in internal space are determined and used to estimate the current target position. The method was validated on 71 cases that were from 3 open access databases. In addition, to evaluate the method’s estimation and prediction accuracy, we compared the method with other works. Results: Except for 2 cases, the nearest neighbor estimation achieved the root-mean-square error of <3 mm. The comparison indicated that the method had better estimation accuracy than polynomial model and good prediction performance. Discussion: The 2 exceptive cases were further analyzed for failure causes. We inferred that one was because of the lack of estimating new target in our method, and the other one was because of the mistake during data collection. Accordingly, the potential solutions were suggested. Besides, the method’s estimation for surrogate outliers, effects of modeling length, calibration, and extension were discussed. Conclusion: The results demonstrated nearest neighbor estimation’s effectiveness. Except for this, the method imposes no restrictions on the modality of the pretreatment target images and does not assume a specific correspondence function between the surrogate and the target. With only 1 critical parameter, this nearest neighbor estimation method is easy to implement in clinical setting and thus has potential for broad applications.


  • A multi-scale feedback ratio analysis of heartbeat interval series in healthy vs. cardiac patients

    by Chengyu Huo, Xiaolin Huang, Huangjing Ni, Hongxing Liu, Chunhua Bian, Xinbao Ning

    The second-order difference plot, as a modified Poincaré plot, is one of the important approaches for assessing the dynamics of heart rate variability. However, corresponding quantitative analysis methods are relatively limited. Based on the second-order difference plot, we propose a novel method, called the multi-scale feedback ratio analysis, which can measure the feedback properties of heart rate fluctuations on different temporal scales. The index [R(TF([τ(1), τ(2)]) is then defined to quantify the average feedback ratio through a definite scale range. Analysis of Gaussian white, 1/f and Brownian noises show that the feedback ratios are indeed on different levels. The method is then applied to heartbeat interval series derived from healthy subjects, subjects with congestive heart failure and subjects with atrial fibrillation. Results show that, for all groups, the feedback ratios vary with increasing time scales, and gradually reach relatively stable states. The R(TF)([10,20]) values of the three groups are significantly different. Thus, R(TF)([10,20]) becomes an effective parameter for distinguishing healthy and pathologic states. In addition, RTF([10,20]) for healthy, congestive failure and atrial fibrillation subjects are close to those of the 1/f, Brownian and white noises respectively, indicating different intrinsic dynamics.


  • Multifractal analysis of resting state fMRI series in default mode network: age and gender effects

    by Huangjing Ni, Xiaolin Huang, Xinbao Ning, Chengyu Huo, Tiebing Liu, De Ben