Xinbao Ning
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xinbao Ning has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Jun Wang
Nanjing University of Posts & Telecommunications
6 shared publicationsYing Chen
4 shared publicationsChengyu Huo
Institute of Biomedical Electronic Engineering, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China; School of Physics and Electronic Engineering, Changshu Institute of Technology, Changshu 215500, China
3 shared publicationsChunhua Bian
Institute of Biomedical Electronic Engineering, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
3 shared publications- Xiaolin Huang
School of Electronic Science and Engineering, Nanjing University, Nanjing, China
3 shared publications Yinlin Xu
State Key Laboratory of Modern Acoustics, Department of Electronic Science and Engineering, Institute for Biomedical Electronic Engineering, Nanjing University, Nanjing 210093, People’s Republic of China
3 shared publications
Latest Publications
- 25 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
BrainZ-BP: A Noninvasive Cuff-Less Blood Pressure Estimation Approach Leveraging Brain Bio-Impedance and Electrocardiogram
Accurate and continuous blood pressure (BP) monitoring is essential to the early prevention of cardiovascular diseases. Non-invasive and cuff-less BP estimation algorithm has gained much attention in recent years. Previous studies have demonstrated that brain bio-impedance (BIOZ) is a promising technique for non-invasive intracranial pressure (ICP) monitoring. Clinically, treatment for patients with traumatic brain injuries (TBI) requires monitoring the ICP and BP of patients simultaneously. Estimating BP by brain BIOZ directly can reduce the number of sensors attached to the patients, thus improving their comfort. To address the issues, in this study, we explore the feasibility of leveraging brain BIOZ for BP estimation and propose a novel cuff-less BP estimation approach called BrainZ-BP. Two electrodes are placed on the forehead and occipital bone of the head in the anterior-posterior direction for brain BIOZ measurement. Various features including pulse transit time and morphological features of brain BIOZ are extracted and fed into four regression models for BP estimation. Results show that the mean absolute error, root mean square error, and correlation coefficient of random forest regression model are 2.17 mmHg, 3.91 mmHg, and 0.90 for systolic pressure estimation, and are 1.71 mmHg, 3.02 mmHg, and 0.89 for diastolic pressure estimation. The presented BrainZ-BP can be applied in the brain BIOZ-based ICP monitoring scenario to monitor BP simultaneously.
- 25 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
BrainZ-BP: A Noninvasive Cuff-Less Blood Pressure Estimation Approach Leveraging Brain Bio-Impedance and Electrocardiogram
Accurate and continuous blood pressure (BP) monitoring is essential to the early prevention of cardiovascular diseases. Non-invasive and cuff-less BP estimation algorithm has gained much attention in recent years. Previous studies have demonstrated that brain bio-impedance (BIOZ) is a promising technique for non-invasive intracranial pressure (ICP) monitoring. Clinically, treatment for patients with traumatic brain injuries (TBI) requires monitoring the ICP and BP of patients simultaneously. Estimating BP by brain BIOZ directly can reduce the number of sensors attached to the patients, thus improving their comfort. To address the issues, in this study, we explore the feasibility of leveraging brain BIOZ for BP estimation and propose a novel cuff-less BP estimation approach called BrainZ-BP. Two electrodes are placed on the forehead and occipital bone of the head in the anterior-posterior direction for brain BIOZ measurement. Various features including pulse transit time and morphological features of brain BIOZ are extracted and fed into four regression models for BP estimation. Results show that the mean absolute error, root mean square error, and correlation coefficient of random forest regression model are 2.17 mmHg, 3.91 mmHg, and 0.90 for systolic pressure estimation, and are 1.71 mmHg, 3.02 mmHg, and 0.89 for diastolic pressure estimation. The presented BrainZ-BP can be applied in the brain BIOZ-based ICP monitoring scenario to monitor BP simultaneously.
- 11 October 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 23 (09)
ECG SIGNAL QUANTITATIVE ANALYSIS BASED ON EXTREMUM ENERGY DECOMPOSITION METHOD
Quantitative analysis of electrocardiogram (ECG) signals plays a pivotal role in objectively and quantitatively assessing cardiac electrical activity. This paper presents an innovative approach for quantitative ECG signal analysis utilizing extremum energy decomposition (EED). The methodology encompasses multiple steps: acquisition of unknown ECG signal under specific time and sampling conditions, denoising of acquired ECG signals, and subsequent decomposition of denoised ECG signals into a set of extremum modal function components alongside a residual. The n extremum modal function components obtained effectively represent different frequency bands. By evaluating these n extremum modal function components, the presence and severity of abnormalities within the ECG signal can be determined. The results showcased the effectiveness of the method in accurately identifying abnormal ECG signals, and the technique demonstrated robustness against noise interference, enhancing its practical utility in clinical and diagnostic settings. This research contributes to the field of ECG analysis by offering a quantitative toolset that enhances the objectivity and accuracy of abnormality assessment in cardiac electrical activity.
- 11 October 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 23 (09)
ECG SIGNAL QUANTITATIVE ANALYSIS BASED ON EXTREMUM ENERGY DECOMPOSITION METHOD
Quantitative analysis of electrocardiogram (ECG) signals plays a pivotal role in objectively and quantitatively assessing cardiac electrical activity. This paper presents an innovative approach for quantitative ECG signal analysis utilizing extremum energy decomposition (EED). The methodology encompasses multiple steps: acquisition of unknown ECG signal under specific time and sampling conditions, denoising of acquired ECG signals, and subsequent decomposition of denoised ECG signals into a set of extremum modal function components alongside a residual. The n extremum modal function components obtained effectively represent different frequency bands. By evaluating these n extremum modal function components, the presence and severity of abnormalities within the ECG signal can be determined. The results showcased the effectiveness of the method in accurately identifying abnormal ECG signals, and the technique demonstrated robustness against noise interference, enhancing its practical utility in clinical and diagnostic settings. This research contributes to the field of ECG analysis by offering a quantitative toolset that enhances the objectivity and accuracy of abnormality assessment in cardiac electrical activity.
- Open Access
- 6 May 2022
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 15, 841077
Editorial: Neural Dynamics – Models and Complexity
Editorial: Neural Dynamics – Models and Complexity
- 6 May 2022
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 15, 841077
Open AccessEditorial: Neural Dynamics – Models and Complexity
Editorial: Neural Dynamics – Models and Complexity
- 16 October 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (12) , 1693-1698
A multi-scale feedback ratio analysis of heartbeat interval series in healthy vs. cardiac patients
The second-order difference plot, as a modified Poincaré plot, is one of the important approaches for assessing the dynamics of heart rate variability. However, corresponding quantitative analysis methods are relatively limited. Based on the second-order difference plot, we propose a novel method, called the multi-scale feedback ratio analysis, which can measure the feedback properties of heart rate fluctuations on different temporal scales. The index [R(TF([τ(1), τ(2)]) is then defined to quantify the average feedback ratio through a definite scale range. Analysis of Gaussian white, 1/f and Brownian noises show that the feedback ratios are indeed on different levels. The method is then applied to heartbeat interval series derived from healthy subjects, subjects with congestive heart failure and subjects with atrial fibrillation. Results show that, for all groups, the feedback ratios vary with increasing time scales, and gradually reach relatively stable states. The R(TF)([10,20]) values of the three groups are significantly different. Thus, R(TF)([10,20]) becomes an effective parameter for distinguishing healthy and pathologic states. In addition, RTF([10,20]) for healthy, congestive failure and atrial fibrillation subjects are close to those of the 1/f, Brownian and white noises respectively, indicating different intrinsic dynamics.
- 16 October 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (12) , 1693-1698
A multi-scale feedback ratio analysis of heartbeat interval series in healthy vs. cardiac patients
The second-order difference plot, as a modified Poincaré plot, is one of the important approaches for assessing the dynamics of heart rate variability. However, corresponding quantitative analysis methods are relatively limited. Based on the second-order difference plot, we propose a novel method, called the multi-scale feedback ratio analysis, which can measure the feedback properties of heart rate fluctuations on different temporal scales. The index [R(TF([τ(1), τ(2)]) is then defined to quantify the average feedback ratio through a definite scale range. Analysis of Gaussian white, 1/f and Brownian noises show that the feedback ratios are indeed on different levels. The method is then applied to heartbeat interval series derived from healthy subjects, subjects with congestive heart failure and subjects with atrial fibrillation. Results show that, for all groups, the feedback ratios vary with increasing time scales, and gradually reach relatively stable states. The R(TF)([10,20]) values of the three groups are significantly different. Thus, R(TF)([10,20]) becomes an effective parameter for distinguishing healthy and pathologic states. In addition, RTF([10,20]) for healthy, congestive failure and atrial fibrillation subjects are close to those of the 1/f, Brownian and white noises respectively, indicating different intrinsic dynamics.
- 18 April 2014
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 59 (25) , 3107-3113
Multifractal analysis of resting state fMRI series in default mode network: age and gender effects
- 18 April 2014
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 59 (25) , 3107-3113
Multifractal analysis of resting state fMRI series in default mode network: age and gender effects
- Open Access
- 14 January 2013
- Published by American Physical Society (APS) in Physical Review E
- Vol. 87 (1) , 012908
Combination of equiprobable symbolization and time reversal asymmetry for heartbeat interval series analysis
Symbolic dynamics method and time reversal asymmetry analysis are both important approaches in the study of heartbeat interval series. However, there is limited research work reported on combining these two methods. We provide a method of time reversal asymmetry analysis which focuses on the differences between the forward and backward embedding ``$m$ words'' after the operation of equiprobable symbolization. To investigate the total amplitude as well as the distribution features of the difference, four indices are proposed. Based on the application to simulation series, we found that these measures can successfully detect time reversal asymmetry in chaos series. With application to human heartbeat interval series ($RR$ series), it is suggested that the distribution features of the forward-backward difference can sensitively capture the dynamical changes caused by diseases or aging. In particular, the index ${E}_{D}$, which reflects the random degree of the forward-backward difference distribution, can significantly discriminate healthy subjects from diseased ones. We conclude that RR series from healthy subjects show more asymmetry in temporal structure on the original time scale from the perspective of equiprobable symbolization, whereas diseases account for loss of this asymmetry.- 14 January 2013
- Published by American Physical Society (APS) in Physical Review E
- Vol. 87 (1) , 012908
Open AccessCombination of equiprobable symbolization and time reversal asymmetry for heartbeat interval series analysis
Symbolic dynamics method and time reversal asymmetry analysis are both important approaches in the study of heartbeat interval series. However, there is limited research work reported on combining these two methods. We provide a method of time reversal asymmetry analysis which focuses on the differences between the forward and backward embedding ``$m$ words'' after the operation of equiprobable symbolization. To investigate the total amplitude as well as the distribution features of the difference, four indices are proposed. Based on the application to simulation series, we found that these measures can successfully detect time reversal asymmetry in chaos series. With application to human heartbeat interval series ($RR$ series), it is suggested that the distribution features of the forward-backward difference can sensitively capture the dynamical changes caused by diseases or aging. In particular, the index ${E}_{D}$, which reflects the random degree of the forward-backward difference distribution, can significantly discriminate healthy subjects from diseased ones. We conclude that RR series from healthy subjects show more asymmetry in temporal structure on the original time scale from the perspective of equiprobable symbolization, whereas diseases account for loss of this asymmetry. - Open Access
- 26 June 2011
- Published by Springer Nature in Science China Life Sciences
- Vol. 54 (6) , 544-552
Complexity and characteristic frequency studies in ECG signals of mice based on multiple scale factors
Existing methods of physiological signal analysis based on nonlinear dynamic theories only examine the complexity difference of the signals under a single sampling frequency. We developed a technique to measure the multifractal characteristic parameter intimately associated with physiological activities through a frequency scale factor. This parameter is highly sensitive to physiological and pathological status. Mice received various drugs to imitate different physiological and pathological conditions, and the distributions of mass exponent spectrum curvature with scale factors from the electrocardiogram (ECG) signals of healthy and drug injected mice were determined. Next, we determined the characteristic frequency scope in which the signal was of the highest complexity and most sensitive to impaired cardiac function, and examined the relationships between heart rate, heartbeat dynamic complexity, and sensitive frequency scope of the ECG signal. We found that all animals exhibited a scale factor range in which the absolute magnitudes of ECG mass exponent spectrum curvature achieve the maximum, and this range (or frequency scope) is not changed with calculated data points or maximal coarse-grained scale factor. Further, the heart rate of mice was not necessarily associated with the nonlinear complexity of cardiac dynamics, but closely related to the most sensitive ECG frequency scope determined by characterization of this complex dynamic features for certain heartbeat conditions. Finally, we found that the health status of the hearts of mice was directly related to the heartbeat dynamic complexity, both of which were positively correlated within the scale factor around the extremum region of the multifractal parameter. With increasing heart rate, the sensitive frequency scope increased to a relatively high location. In conclusion, these data provide important theoretical and practical data for the early diagnosis of cardiac disorders.
- 26 June 2011
- Published by Springer Nature in Science China Life Sciences
- Vol. 54 (6) , 544-552
Open AccessComplexity and characteristic frequency studies in ECG signals of mice based on multiple scale factors
Existing methods of physiological signal analysis based on nonlinear dynamic theories only examine the complexity difference of the signals under a single sampling frequency. We developed a technique to measure the multifractal characteristic parameter intimately associated with physiological activities through a frequency scale factor. This parameter is highly sensitive to physiological and pathological status. Mice received various drugs to imitate different physiological and pathological conditions, and the distributions of mass exponent spectrum curvature with scale factors from the electrocardiogram (ECG) signals of healthy and drug injected mice were determined. Next, we determined the characteristic frequency scope in which the signal was of the highest complexity and most sensitive to impaired cardiac function, and examined the relationships between heart rate, heartbeat dynamic complexity, and sensitive frequency scope of the ECG signal. We found that all animals exhibited a scale factor range in which the absolute magnitudes of ECG mass exponent spectrum curvature achieve the maximum, and this range (or frequency scope) is not changed with calculated data points or maximal coarse-grained scale factor. Further, the heart rate of mice was not necessarily associated with the nonlinear complexity of cardiac dynamics, but closely related to the most sensitive ECG frequency scope determined by characterization of this complex dynamic features for certain heartbeat conditions. Finally, we found that the health status of the hearts of mice was directly related to the heartbeat dynamic complexity, both of which were positively correlated within the scale factor around the extremum region of the multifractal parameter. With increasing heart rate, the sensitive frequency scope increased to a relatively high location. In conclusion, these data provide important theoretical and practical data for the early diagnosis of cardiac disorders.
- 11 July 2010
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 55 (19) , 1996-2003
Multifractal mass exponent spectrum of complex physiological time series
- 11 July 2010
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 55 (19) , 1996-2003
Multifractal mass exponent spectrum of complex physiological time series
- 1 October 2009
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 54 (20) , 3784-3789
Multiscale analysis of heart beat interval increment series and its clinical significance
- 1 October 2009
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 54 (20) , 3784-3789
Multiscale analysis of heart beat interval increment series and its clinical significance
- 20 June 2009
- Published by Elsevier in Science Bulletin
- Vol. 54 (24) , 4610-4615
Sign series entropy analysis of short-term heart rate variability
- 20 June 2009
- Published by Elsevier in Science Bulletin
- Vol. 54 (24) , 4610-4615
Sign series entropy analysis of short-term heart rate variability