Karla Danielle Tavares de Melo Milanez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karla Danielle Tavares de Melo Milanez has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ada Vivianny Pereira Santos
Department of Chemistry, Federal University of Paraíba, João Pessoa, Brazil
1 shared publication - Anna Luiza Bizerra Brito
University of Coimbra, Coimbra Chemistry Centre – Institute of Molecular Sciences and Department of Chemistry, 3004-535 Coimbra, Portugal
1 shared publication - Liliana Fátima Bezerra Lira Pontes
Center for Exact and Natural Sciences, Federal University of Paraíba, João Pessoa, PB, Brazil
1 shared publication - Marcelo Fabian Pistonesi
Departamento de Química, Universidad Nacional del Sur, INQUISUR, Avenida Alem 1253 (B8000CPB), Bahía Blanca 8000, Argentina
1 shared publication - Mayara Ferreira Barbosa
MFB Assessoria Química
1 shared publication - Márcio José Coelho Pontes
Postgraduate Program in Chemistry, Federal University of Paraíba, Center for Exact and Nature Sciences, João Pessoa, Paraíba, Brazil
1 shared publication
Latest Publications
- 26 April 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (21) , 3184-3190
Calibration transfer of flour NIR spectra between benchtop and portable instruments
This work reports on the use of different strategies of calibration transfer to determine crude protein and fiber properties in samples of functional flours analyzed with benchtop (primary) and portable (secondary) NIR instruments. For this purpose, methods of direct standardization (DS) and reverse standardization (RS) were used on a different number of transfer samples. Calibration models based on the following regression strategies were evaluated: partial least squares using a full spectrum (PLSfull spectrum); PLS with significant regression coefficients selected by the Jack-Knife algorithm (PLS/JK) and multiple linear regression (MLR) with previous selection of variables by the successive projection algorithm (MLR/SPA). The performance of calibration models was assessed according to Root Mean Square Error of Prediction (RMSEP) values obtained in a prediction subset measured on a secondary instrument before and after standardization procedures. Before standardization, all the calibration models presented high RMSEP values for the prediction samples measured on the secondary instrument to determine both crude protein and fibers. After the direct standardization, a considerable decrease of the RMSEP values was observed in the PLSfull spectrum and MLR/SPA calibration models developed for crude protein determination. For fiber determination, the lowest RMSEP value was obtained using the PLSfull spectrum model with RS, although no statistically significant difference was found between the RMSEP values obtained for PLS/JK and MLR/SPA models.
- 26 April 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (21) , 3184-3190
Calibration transfer of flour NIR spectra between benchtop and portable instruments
This work reports on the use of different strategies of calibration transfer to determine crude protein and fiber properties in samples of functional flours analyzed with benchtop (primary) and portable (secondary) NIR instruments. For this purpose, methods of direct standardization (DS) and reverse standardization (RS) were used on a different number of transfer samples. Calibration models based on the following regression strategies were evaluated: partial least squares using a full spectrum (PLSfull spectrum); PLS with significant regression coefficients selected by the Jack-Knife algorithm (PLS/JK) and multiple linear regression (MLR) with previous selection of variables by the successive projection algorithm (MLR/SPA). The performance of calibration models was assessed according to Root Mean Square Error of Prediction (RMSEP) values obtained in a prediction subset measured on a secondary instrument before and after standardization procedures. Before standardization, all the calibration models presented high RMSEP values for the prediction samples measured on the secondary instrument to determine both crude protein and fibers. After the direct standardization, a considerable decrease of the RMSEP values was observed in the PLSfull spectrum and MLR/SPA calibration models developed for crude protein determination. For fiber determination, the lowest RMSEP value was obtained using the PLSfull spectrum model with RS, although no statistically significant difference was found between the RMSEP values obtained for PLS/JK and MLR/SPA models.
- 1 February 2016
- Published by Elsevier in Food Chemistry
- Vol. 192, 374-379
Using UV–Vis spectroscopy for simultaneous geographical and varietal classification of tea infusions simulating a home-made tea cup
- 1 February 2016
- Published by Elsevier in Food Chemistry
- Vol. 192, 374-379
Using UV–Vis spectroscopy for simultaneous geographical and varietal classification of tea infusions simulating a home-made tea cup