Manoras Chengalath
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Manoras Chengalath has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- John Deakin Lees Brookes
Department of Cardiothoracic Surgery, University Hospital Geelong, Barwon Health, Geelong, VIC, Australia
2 shared publications Jose Chacko Periappuram
Lisie Hospital
2 shared publicationsBhaskar Ranganathan
Department of Cardiothoracic Surgery, Lisie Hospital, Ernakulam, Kerala, India
1 shared publicationCheng-Hon Yap
Department of Cardiothoracic Surgery, University Hospital Geelong, Barwon Health, Geelong, Vic, Australia; School of Medicine, Faculty of Health, Deakin University, Geelong, Vic, Australia
1 shared publication- Cheng-Hon Yap
Department of Cardiothoracic Surgery, University Hospital Geelong, Barwon Health, Geelong, VIC 3220, Australia
1 shared publication Christopher Morley
Department of Cardiothoracic Surgery, University Hospital Geelong, Barwon Health, Geelong, VIC, Australia
1 shared publication
Latest Publications
- 26 December 2025
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 35 (2) , 236-243
Safety of Early Coronary Surgery in Antiplatelet Non-Responders: A Retrospective Cohort Study
- 26 December 2025
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 35 (2) , 236-243
Safety of Early Coronary Surgery in Antiplatelet Non-Responders: A Retrospective Cohort Study
- Open Access
- 21 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7029
Simplifying Mitral Valve Repair with Novel Premeasured Chordal Loops
Background: The ”respect” approach to surgical mitral valve repair, which involves implanting artificial neochordae, is gaining increased adoption. Surgeons are possibly prone to error in the manual construction of neochordae, which can lead to prolonged cross-clamp times. Novel systems such as Chord-X Pre-Measured Loops (On-X Life Technologies, Inc., Austin, TX, USA) eliminate the need for manual neochordae construction, potentially simplifying the mitral repair procedure. However, clinical data on its use are currently limited to a small publication. Methods: We conducted a retrospective cohort study to evaluate the use of Chord-X loops in 40 consecutive patients who underwent surgery in Geelong, Victoria, Australia, between May 2020 and February 2024. Three surgeons participated in this study. Results: All patients were referred for severe mitral valve regurgitation secondary to myxomatous degeneration, with P2 prolapse being the most common pathology. Chord-X Pre-Measured Loops effectively corrected a variety of leaflet pathologies, including bi-leaflet disease, with a single set of loops sufficing in most patients. Intraoperative and follow-up echocardiographic assessments revealed no greater than mild mitral regurgitation in any patient, with 75% exhibiting no or trace mitral regurgitation. Conclusions: The Chord-X Pre-Measured Loops system demonstrated safety, efficacy, and reproducibility across all patients. Surgeons were able to easily adopt this technology without requiring additional training. We believe this technology offers a safe option for surgeons performing low-volume mitral repair surgeries.
- 21 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7029
Open AccessSimplifying Mitral Valve Repair with Novel Premeasured Chordal Loops
Background: The ”respect” approach to surgical mitral valve repair, which involves implanting artificial neochordae, is gaining increased adoption. Surgeons are possibly prone to error in the manual construction of neochordae, which can lead to prolonged cross-clamp times. Novel systems such as Chord-X Pre-Measured Loops (On-X Life Technologies, Inc., Austin, TX, USA) eliminate the need for manual neochordae construction, potentially simplifying the mitral repair procedure. However, clinical data on its use are currently limited to a small publication. Methods: We conducted a retrospective cohort study to evaluate the use of Chord-X loops in 40 consecutive patients who underwent surgery in Geelong, Victoria, Australia, between May 2020 and February 2024. Three surgeons participated in this study. Results: All patients were referred for severe mitral valve regurgitation secondary to myxomatous degeneration, with P2 prolapse being the most common pathology. Chord-X Pre-Measured Loops effectively corrected a variety of leaflet pathologies, including bi-leaflet disease, with a single set of loops sufficing in most patients. Intraoperative and follow-up echocardiographic assessments revealed no greater than mild mitral regurgitation in any patient, with 75% exhibiting no or trace mitral regurgitation. Conclusions: The Chord-X Pre-Measured Loops system demonstrated safety, efficacy, and reproducibility across all patients. Surgeons were able to easily adopt this technology without requiring additional training. We believe this technology offers a safe option for surgeons performing low-volume mitral repair surgeries.
- 13 June 2023
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 32, S14
Thromboelastogram Assessment of Dual Antiplatelet Effect in Cardiac Surgery
- 13 June 2023
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 32, S14
Thromboelastogram Assessment of Dual Antiplatelet Effect in Cardiac Surgery
- 20 September 2018
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 35 (1) , 108-110
Explanting the migrated hepatic stent in the right atrium by modified vena caval inflow occlusion
Stenting of hepatic veins can be a long lasting solution for Budd–Chiari syndrome. These stents could very rarely migrate into the right atrium. During surgical retrieval, cardiopulmonary bypass (CPB) can be avoided if vena caval inflow occlusion (VCIO) is used. A hybrid alternative of VCIO by using a balloon to occlude the inferior vena cava was done to retrieve the stent thus avoiding CPB and total circulatory arrest.
- 20 September 2018
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 35 (1) , 108-110
Explanting the migrated hepatic stent in the right atrium by modified vena caval inflow occlusion
Stenting of hepatic veins can be a long lasting solution for Budd–Chiari syndrome. These stents could very rarely migrate into the right atrium. During surgical retrieval, cardiopulmonary bypass (CPB) can be avoided if vena caval inflow occlusion (VCIO) is used. A hybrid alternative of VCIO by using a balloon to occlude the inferior vena cava was done to retrieve the stent thus avoiding CPB and total circulatory arrest.
- 28 November 2017
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 26 (1) , 67
Is Commissural region tear an Achilles' heel of the Trifecta aortic bioprosthesis?
- 28 November 2017
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 26 (1) , 67
Is Commissural region tear an Achilles' heel of the Trifecta aortic bioprosthesis?