Cheng-Hon Yap
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cheng-Hon Yap has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Shell
Department of Cardiothoracic Surgery, University Hospital Geelong, Barwon Health, Geelong, VIC 3220, Australia
2 shared publications - Andrew Mekhail
Department of Cardiothoracic Surgery, University Hospital Geelong, Barwon Health, Geelong, VIC 3220, Australia
1 shared publication - Manoras Chengalath
Department of Cardiothoracic Surgery, University Hospital Geelong, Barwon Health, Geelong, VIC, Australia
1 shared publication - Michael Rowland
Department of Cardiothoracic Surgery, Barwon Health, Geelong, VIC 3220, Australia
1 shared publication - Michael Seitz
Department of Cardiothoracic Surgery, Barwon Health, Geelong, VIC 3220, Australia
1 shared publication - Natcha Bunwatcharaphan
Department of Cardiothoracic Surgery, Barwon Health, Geelong, VIC 3220, Australia
1 shared publication
Latest Publications
- Open Access
Right Anterior Thoracotomy Aortic Valve Replacement: Technique and Early Outcomes in 156 Patients
Background: Right anterior thoracotomy aortic valve replacement (RAT-AVR) is an established minimally invasive alternative to conventional sternotomy, but published experience largely reflects late-experience series from specialised centres. Data describing operative technique and early outcomes during real-world adoption remain limited. Methods: We describe our operative technique and early outcomes in 156 consecutive intended isolated RAT-AVR procedures performed by a single surgeon between January 2015 and November 2025. Operative times were compared between the first 50 and subsequent 106 cases and assessed using cumulative sum analysis. Results: Median age was 70 years and median EuroSCORE II was 1.00% [IQR 0.71–1.56]. Peripheral cannulation was used in most cases, with central cannulation employed selectively. Mechanical and biological prostheses spanning 19–29 mm were implanted, demonstrating that prosthesis choice was not restricted in this cohort. Median cardiopulmonary bypass and cross-clamp times were 109 and 79 min, respectively. Both were shorter after the first 50 cases (120.5 versus 106.0 min, p = 0.003; 85.5 versus 77.0 min, p = 0.048). Conversion to sternotomy occurred in two patients, both of whom survived to discharge and 30 days. Thirty-day mortality was 2/156 (1.3%). Conclusions: This consecutive single-surgeon experience supports the feasibility and early safety of RAT-AVR in selected patients, with operative efficiency improving during adoption. RAT-AVR represents a pragmatic minimally invasive option for isolated surgical aortic valve replacement.
Open AccessRight Anterior Thoracotomy Aortic Valve Replacement: Technique and Early Outcomes in 156 Patients
Background: Right anterior thoracotomy aortic valve replacement (RAT-AVR) is an established minimally invasive alternative to conventional sternotomy, but published experience largely reflects late-experience series from specialised centres. Data describing operative technique and early outcomes during real-world adoption remain limited. Methods: We describe our operative technique and early outcomes in 156 consecutive intended isolated RAT-AVR procedures performed by a single surgeon between January 2015 and November 2025. Operative times were compared between the first 50 and subsequent 106 cases and assessed using cumulative sum analysis. Results: Median age was 70 years and median EuroSCORE II was 1.00% [IQR 0.71–1.56]. Peripheral cannulation was used in most cases, with central cannulation employed selectively. Mechanical and biological prostheses spanning 19–29 mm were implanted, demonstrating that prosthesis choice was not restricted in this cohort. Median cardiopulmonary bypass and cross-clamp times were 109 and 79 min, respectively. Both were shorter after the first 50 cases (120.5 versus 106.0 min, p = 0.003; 85.5 versus 77.0 min, p = 0.048). Conversion to sternotomy occurred in two patients, both of whom survived to discharge and 30 days. Thirty-day mortality was 2/156 (1.3%). Conclusions: This consecutive single-surgeon experience supports the feasibility and early safety of RAT-AVR in selected patients, with operative efficiency improving during adoption. RAT-AVR represents a pragmatic minimally invasive option for isolated surgical aortic valve replacement.
- Open Access
- 22 June 2026
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 16 (6) , 335
Three-Dimensional Bronchovascular Modelling in Sublobar Pulmonary Resection: A Tool for Personalised Thoracic Surgery
Sublobar pulmonary resection has become an increasingly adopted approach for early-stage non-small cell lung cancer, driven by evidence that anatomical segmentectomy can achieve oncological outcomes comparable to lobectomy in selected patients. Safe execution of sublobar resection depends on accurate preoperative identification of segmental bronchovascular anatomy, which demonstrates substantial variability. Conventional two-dimensional (2D) computed tomography (CT) imposes significant limitations on anatomical interpretation, particularly at the segmental and subsegmental level. Three-dimensional (3D) bronchovascular modelling provides patient-specific representations of segmental anatomy and relationships that address these limitations. This narrative review examines the current and emerging roles of 3D modelling in personalised thoracic surgery. It discusses the anatomical basis for its application, the limitations of conventional imaging, and the contribution of 3D modelling to preoperative planning and intraoperative decision making. It also considers broader applications, current limitations, and future directions, with emphasis on how patient-specific 3D modelling can support more tailored operative strategies and more individualised surgical care.
- 22 June 2026
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 16 (6) , 335
Open AccessThree-Dimensional Bronchovascular Modelling in Sublobar Pulmonary Resection: A Tool for Personalised Thoracic Surgery
Sublobar pulmonary resection has become an increasingly adopted approach for early-stage non-small cell lung cancer, driven by evidence that anatomical segmentectomy can achieve oncological outcomes comparable to lobectomy in selected patients. Safe execution of sublobar resection depends on accurate preoperative identification of segmental bronchovascular anatomy, which demonstrates substantial variability. Conventional two-dimensional (2D) computed tomography (CT) imposes significant limitations on anatomical interpretation, particularly at the segmental and subsegmental level. Three-dimensional (3D) bronchovascular modelling provides patient-specific representations of segmental anatomy and relationships that address these limitations. This narrative review examines the current and emerging roles of 3D modelling in personalised thoracic surgery. It discusses the anatomical basis for its application, the limitations of conventional imaging, and the contribution of 3D modelling to preoperative planning and intraoperative decision making. It also considers broader applications, current limitations, and future directions, with emphasis on how patient-specific 3D modelling can support more tailored operative strategies and more individualised surgical care.
- Open Access
- 21 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7029
Simplifying Mitral Valve Repair with Novel Premeasured Chordal Loops
Background: The ”respect” approach to surgical mitral valve repair, which involves implanting artificial neochordae, is gaining increased adoption. Surgeons are possibly prone to error in the manual construction of neochordae, which can lead to prolonged cross-clamp times. Novel systems such as Chord-X Pre-Measured Loops (On-X Life Technologies, Inc., Austin, TX, USA) eliminate the need for manual neochordae construction, potentially simplifying the mitral repair procedure. However, clinical data on its use are currently limited to a small publication. Methods: We conducted a retrospective cohort study to evaluate the use of Chord-X loops in 40 consecutive patients who underwent surgery in Geelong, Victoria, Australia, between May 2020 and February 2024. Three surgeons participated in this study. Results: All patients were referred for severe mitral valve regurgitation secondary to myxomatous degeneration, with P2 prolapse being the most common pathology. Chord-X Pre-Measured Loops effectively corrected a variety of leaflet pathologies, including bi-leaflet disease, with a single set of loops sufficing in most patients. Intraoperative and follow-up echocardiographic assessments revealed no greater than mild mitral regurgitation in any patient, with 75% exhibiting no or trace mitral regurgitation. Conclusions: The Chord-X Pre-Measured Loops system demonstrated safety, efficacy, and reproducibility across all patients. Surgeons were able to easily adopt this technology without requiring additional training. We believe this technology offers a safe option for surgeons performing low-volume mitral repair surgeries.
- 21 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7029
Open AccessSimplifying Mitral Valve Repair with Novel Premeasured Chordal Loops
Background: The ”respect” approach to surgical mitral valve repair, which involves implanting artificial neochordae, is gaining increased adoption. Surgeons are possibly prone to error in the manual construction of neochordae, which can lead to prolonged cross-clamp times. Novel systems such as Chord-X Pre-Measured Loops (On-X Life Technologies, Inc., Austin, TX, USA) eliminate the need for manual neochordae construction, potentially simplifying the mitral repair procedure. However, clinical data on its use are currently limited to a small publication. Methods: We conducted a retrospective cohort study to evaluate the use of Chord-X loops in 40 consecutive patients who underwent surgery in Geelong, Victoria, Australia, between May 2020 and February 2024. Three surgeons participated in this study. Results: All patients were referred for severe mitral valve regurgitation secondary to myxomatous degeneration, with P2 prolapse being the most common pathology. Chord-X Pre-Measured Loops effectively corrected a variety of leaflet pathologies, including bi-leaflet disease, with a single set of loops sufficing in most patients. Intraoperative and follow-up echocardiographic assessments revealed no greater than mild mitral regurgitation in any patient, with 75% exhibiting no or trace mitral regurgitation. Conclusions: The Chord-X Pre-Measured Loops system demonstrated safety, efficacy, and reproducibility across all patients. Surgeons were able to easily adopt this technology without requiring additional training. We believe this technology offers a safe option for surgeons performing low-volume mitral repair surgeries.