JKJuraj Knoska

Juraj Knoska

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Juraj Knoska has a total of 568 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Radiation damage in serial femtosecond crystallography studied in hemoglobin

    by Marina Galchenkova, Ibrahim Dawod, Sebastian Cardoch, Janina Sprenger, Dominik Oberthür, Salah Awel, Emiliano De Santis, Oscar Grånäs, Juraj Knoska, Markus Metz, et al.

    A central question in macromolecular crystallography is what X-ray free-electron laser pulse duration is required to obtain damage-free structural information. We compare serial femtosecond crystallography data from hemoglobin crystals using 3 and 10 fs pulses at comparable peak intensities (∼3 × 10 17 W cm −2 ) and fixed photon energy (7.15 keV). Structural refinement produced very similar models and resolution-dependent data-quality indicators remained comparable. Both datasets also retained sufficient anomalous signal for phasing. These observations support the conclusion that high-resolution scattering was preserved under both pulse durations. Hybrid collisional–radiative and molecular-dynamics simulations show that under typical experimental conditions, atomic form-factor changes are negligible (<1%) and atomic displacements fall below the resolution limit imposed by the X-ray photon energy and the geometry of the detector. The combined experimental and theoretical results indicate that 10 fs pulses are adequate to obtain damage-free protein structures using femtosecond crystallography under the intensity conditions explored.

  • Open Access

    SARS-CoV-2 Mpro responds to oxidation by forming disulfide and NOS/SONOS bonds

    by Patrick Y. A. Reinke, Robin Schubert, Dominik Oberthür, Marina Galchenkova, Aida Rahmani Mashhour, Sebastian Günther, Anaïs Chretien, Adam Round, Brandon Charles Seychell, Brenna Norton-Baker, et al.

    The main protease (Mpro) of SARS-CoV-2 is critical for viral function and a key drug target. Mpro is only active when reduced; turnover ceases upon oxidation but is restored by re-reduction. This suggests the system has evolved to survive periods in an oxidative environment, but the mechanism of this protection has not been confirmed. Here, we report a crystal structure of oxidized Mpro showing a disulfide bond between the active site cysteine, C145, and a distal cysteine, C117. Previous work proposed this disulfide provides the mechanism of protection from irreversible oxidation. Mpro forms an obligate homodimer, and the C117-C145 structure shows disruption of interactions bridging the dimer interface, implying a correlation between oxidation and dimerization. We confirm dimer stability is weakened in solution upon oxidation. Finally, we observe the protein’s crystallization behavior is linked to its redox state. Oxidized Mpro spontaneously forms a distinct, more loosely packed lattice. Seeding with crystals of this lattice yields a structure with an oxidation pattern incorporating one cysteine-lysine-cysteine (SONOS) and two lysine-cysteine (NOS) bridges. These structures further our understanding of the oxidative regulation of Mpro and the crystallization conditions necessary to study this structurally.


  • Open Access

    Megahertz pulse trains enable multi-hit serial femtosecond crystallography experiments at X-ray free electron lasers

    by Susannah Holmes, Henry J. Kirkwood, Richard Bean, Klaus Giewekemeyer, Andrew V. Martin, Marjan Hadian-Jazi, Max O. Wiedorn, Dominik Oberthür, Hugh Marman, Luigi Adriano, et al.

    The European X-ray Free Electron Laser (XFEL) and Linac Coherent Light Source (LCLS) II are extremely intense sources of X-rays capable of generating Serial Femtosecond Crystallography (SFX) data at megahertz (MHz) repetition rates. Previous work has shown that it is possible to use consecutive X-ray pulses to collect diffraction patterns from individual crystals. Here, we exploit the MHz pulse structure of the European XFEL to obtain two complete datasets from the same lysozyme crystal, first hit and the second hit, before it exits the beam. The two datasets, separated by <1 µs, yield up to 2.1 Å resolution structures. Comparisons between the two structures reveal no indications of radiation damage or significant changes within the active site, consistent with the calculated dose estimates. This demonstrates MHz SFX can be used as a tool for tracking sub-microsecond structural changes in individual single crystals, a technique we refer to as multi-hit SFX.


  • Open Access

    On the use of multilayer Laue lenses with X-ray Free Electron Lasers

    by Mauro Prasciolu, Kevin T. Murray, Nikolay Ivanov, Holger Fleckenstein, Martin Domaracký, Luca Gelisio, Fabian Trost, Kartik Ayyer, Dietrich Krebs, Steve Aplin, et al.

    Multilayer Laue lenses were used for the first time to focus x-rays from an X-ray Free Electron Laser (XFEL). In an experiment, which was performed at the European XFEL, we demonstrated focusing to a spot size of a few tens of nanometers. A series of runs in which the number of pulses per train was increased from 1 to 2, 3, 4, 5, 6, 7, 10, 20 and 30 pulses per train, all with a pulse separation of 3.55 us, was done using the same set of lenses. The increase in the number of pulses per train was accompanied with an increase of x-ray intensity (transmission) from 9% to 92% at 5 pulses per train, and then the transmission was reduced to 23.5 % when the pulses were increased further. The final working condition was 30 pulses per train and 23.5% transmission. Only at this condition we saw that the diffraction efficiency of the MLLs changed over the course of a pulse train, and this variation was reproducible from train to train. We present the procedure to align and characterize these lenses and discuss challenges working with the pulse trains from this unique x-ray source.

  • Open Access

    3D printed devices and infrastructure for liquid sample delivery at the European XFEL

    by Mohammad Vakili, Johan Bielecki, Juraj Knoška, Florian Otte, Huijong Han, Marco Kloos, Robin Schubert, Elisa Delmas, Grant Mills, Raphael de Wijn, et al.

    The Sample Environment and Characterization (SEC) group of the European X-ray Free-Electron Laser (EuXFEL) develops sample delivery systems for the various scientific instruments, including systems for the injection of liquid samples that enable serial femtosecond X-ray crystallography (SFX) and single-particle imaging (SPI) experiments, among others. For rapid prototyping of various device types and materials, sub-micrometre precision 3D printers are used to address the specific experimental conditions of SFX and SPI by providing a large number of devices with reliable performance. This work presents the current pool of 3D printed liquid sample delivery devices, based on the two-photon polymerization (2PP) technique. These devices encompass gas dynamic virtual nozzles (GDVNs), mixing-GDVNs, high-viscosity extruders (HVEs) and electrospray conical capillary tips (CCTs) with highly reproducible geometric features that are suitable for time-resolved SFX and SPI experiments at XFEL facilities. Liquid sample injection setups and infrastructure on the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument are described, this being the instrument which is designated for biological structure determination at the EuXFEL.


  • Co-flow injection for serial crystallography at X-ray free-electron lasers

    by Diandra Doppler, Mohammad T. Rabbani, Romain Letrun, Jorvani Cruz Villarreal, Dai Hyun Kim, Sahir Gandhi, Ana Egatz-Gomez, Mukul Sonker, Joe Chen, Faisal H. M. Koua, et al.

    Serial femtosecond crystallography (SFX) is a powerful technique that exploits X-ray free-electron lasers to determine the structure of macromolecules at room temperature. Despite the impressive exposition of structural details with this novel crystallographic approach, the methods currently available to introduce crystals into the path of the X-ray beam sometimes exhibit serious drawbacks. Samples requiring liquid injection of crystal slurries consume large quantities of crystals (at times up to a gram of protein per data set), may not be compatible with vacuum configurations on beamlines or provide a high background due to additional sheathing liquids present during the injection. Proposed and characterized here is the use of an immiscible inert oil phase to supplement the flow of sample in a hybrid microfluidic 3D-printed co-flow device. Co-flow generation is reported with sample and oil phases flowing in parallel, resulting in stable injection conditions for two different resin materials experimentally. A numerical model is presented that adequately predicts these flow-rate conditions. The co-flow generating devices reduce crystal clogging effects, have the potential to conserve protein crystal samples up to 95% and will allow degradation-free light-induced time-resolved SFX.


  • Open Access

    The Natural Breakup Length of a Steady Capillary Jet: Application to Serial Femtosecond Crystallography

    by Alfonso M. Gañán-Calvo, Henry N. Chapman, Michael Heymann, Max O. Wiedorn, Juraj Knoska, Braulio Gañán-Riesco, José M. López-Herrera, Francisco Cruz-Mazo, Miguel A. Herrada, José M. Montanero, et al.

    One of the most successful ways to introduce samples in Serial Femtosecond Crystallography has been the use of microscopic capillary liquid jets produced by gas flow focusing, whose length-to-diameter ratio and velocity are essential to fulfill the requirements of the high pulse rates of current XFELs. In this work, we demonstrate the validity of a classical scaling law with two universal constants to calculate that length as a function of the liquid properties and operating conditions. These constants are determined by fitting the scaling law to a large set of experimental and numerical measurements, including previously published data. Both the experimental and numerical jet lengths conform remarkably well to the proposed scaling law. We show that, while a capillary jet is a globally unstable system to linear perturbations above a critical length, its actual and shorter long-term average intact length is determined by the nonlinear perturbations coming from the jet breakup itself. Therefore, this length is determined solely by the properties of the liquid, the average velocity of the liquid and the flow rate expelled. This confirms the very early observations from Smith and Moss 1917, Proc R Soc Lond A Math Phys Eng, 93, 373, to McCarthy and Molloy 1974, Chem Eng J, 7, 1, among others, while it contrasts with the classical conception of temporal stability that attributes the natural breakup length to the jet birth conditions in the ejector or small interactions with the environment.


  • Top Cited Papers
    Open Access

    X-ray screening identifies active site and allosteric inhibitors of SARS-CoV-2 main protease

    by Sebastian Günther, Patrick Y. A. Reinke, Yaiza Fernández-García, Julia Lieske, Thomas J. Lane, Helen M. Ginn, Faisal H. M. Koua, Christiane Ehrt, Wiebke Ewert, Dominik Oberthuer, et al.

    A large-scale screen to target SARS-CoV-2: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) genome is initially expressed as two large polyproteins. Its main protease, M pro , is essential to yield functional viral proteins, making it a key drug target. Günther et al. used x-ray crystallography to screen more than 5000 compounds that are either approved drugs or drugs in clinical trials. The screen identified 37 compounds that bind to M pro . High-resolution structures showed that most compounds bind at the active site but also revealed two allosteric sites where binding of a drug causes conformational changes that affect the active site. In cell-based assays, seven compounds had antiviral activity without toxicity. The most potent, calpeptin, binds covalently in the active site, whereas the second most potent, pelitinib, binds at an allosteric site. Science , this issue p. 642


  • Open Access

    Synchronous RNA conformational changes trigger ordered phase transitions in crystals

    by Saminathan Ramakrishnan, Jason R. Stagno, Chelsie E. Conrad, Jienyu Ding, Ping Yu, Yuba R. Bhandari, Yun-Tzai Lee, Gary Pauly, Oleksandr Yefanov, Max O. Wiedorn, et al.

    Time-resolved studies of biomacromolecular crystals have been limited to systems involving only minute conformational changes within the same lattice. Ligand-induced changes greater than several angstroms, however, are likely to result in solid-solid phase transitions, which require a detailed understanding of the mechanistic interplay between conformational and lattice transitions. Here we report the synchronous behavior of the adenine riboswitch aptamer RNA in crystal during ligand-triggered isothermal phase transitions. Direct visualization using polarized video microscopy and atomic force microscopy shows that the RNA molecules undergo cooperative rearrangements that maintain lattice order, whose cell parameters change distinctly as a function of time. The bulk lattice order throughout the transition is further supported by time-resolved diffraction data from crystals using an X-ray free electron laser. The synchronous molecular rearrangements in crystal provide the physical basis for studying large conformational changes using time-resolved crystallography and micro/nanocrystals.


  • Open Access

    Segmented flow generator for serial crystallography at the European X-ray free electron laser

    by Austin Echelmeier, Jorvani Cruz Villarreal, Marc Messerschmidt, Daihyun Kim, Jesse D. Coe, Darren Thifault, Sabine Botha, Ana Egatz-Gomez, Sahir Gandhi, Gerrit Brehm, et al.

    Serial femtosecond crystallography (SFX) with X-ray free electron lasers (XFELs) allows structure determination of membrane proteins and time-resolved crystallography. Common liquid sample delivery continuously jets the protein crystal suspension into the path of the XFEL, wasting a vast amount of sample due to the pulsed nature of all current XFEL sources. The European XFEL (EuXFEL) delivers femtosecond (fs) X-ray pulses in trains spaced 100 ms apart whereas pulses within trains are currently separated by 889 ns. Therefore, continuous sample delivery via fast jets wastes >99% of sample. Here, we introduce a microfluidic device delivering crystal laden droplets segmented with an immiscible oil reducing sample waste and demonstrate droplet injection at the EuXFEL compatible with high pressure liquid delivery of an SFX experiment. While achieving ~60% reduction in sample waste, we determine the structure of the enzyme 3-deoxy-D-manno-octulosonate-8-phosphate synthase from microcrystals delivered in droplets revealing distinct structural features not previously reported.