MHMichael Heymann

Michael Heymann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael Heymann has a total of 541 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sequential stenciling to reconstitute 2D microtissues for multicellular and synthetic signaling architectures

    by Kai Hirzel, Jasmin Čić, Stella Asmanidou, Nadja Schmohl, Roland E Kontermann, Satoshi Toda, Monilola A Olayioye, Andrew G Clark, Michael Heymann

    In mammalian organisms, native tissue function depends on precise spatial organization down to the cellular level. Reconstituting tissue architectures in 2D in vivo platforms can provide a means to study direct and indirect cell-cell interactions in a variety of tissue contexts while remaining compatible with high-throughput assays and high-resolution live imaging. We combine cost-effective stereolithography leveraging 3D printing with replica molding to stencil spatially defined, multicellular culture systems with sub-millimeter resolution onto planar substrates. The system is designed for ease of use, requires no complex fabrication setups and scales readily to 96-well plates. Sequential stencil application and removal under a biosafety cabinet enables controlled positioning of multiple cell types and supports the maturation of tissue assemblies. We demonstrate the utility of this stencil-based patterning strategy in three applications. First, we employ a combination of two circular stencils to recreate a structural feature characteristic of the tumor microenvironment of solid tumors: the encapsulation of colorectal cancer cells by cancer-associated fibroblast (CAF) cells. Resulting cell patterns recapitulate key aspects of native tissue dynamics of the densely packed tumor tissues, in which CAF cells actively compress the cancer cells and confer targeted therapy resistance. Second, we probe an engineered synNotch-based signaling system in patterned cell patches that mimics morphogen gradient formation, where GFP-secreting sender cells generate a ligand-dependent gradient. Third, we recapitulate the characteristic crypt-villus architecture of the mammalian intestine by patterning intestinal organoids within a stencil-restricted crypt region and allowing differentiating cells to collectively migrate along a designed villus axis. The presented strategy allows for rebuilding multicellular tissue architectures in vitro with biologically relevant spatial precision for high-throughput drug screenings and dissection of tissue-specific cellular interactions.

  • Open Access

    Bridging dimensions: combining one- and two-photon 3D printing for microfluidic device fabrication

    by Oliver Walker, Robin R. Benedix, Julian Fischer, Kai Hirzel, Cosima Stubenrauch, Michael Heymann

    Combining one- and two-photon 3D printing through an aligned adapter interface enables time-efficient microfluidic device fabrication while preserving high resolution only where needed.

  • Open Access

    Two-photon 3D-printed BSA hydrogel fibers resemble native muscle contraction dynamics

    by Theresa Kühn, André Tomalka, Tobias Siebert, Michael Heymann

    Force generation dynamics in native muscle tissues have been stringently optimized by evolution. Realizing similar contractile dynamics in a widely available biomaterial and subsequently fabricating macroscopic functional modules from them remains challenging. Herein, we tailor two-photon stereolithography to 3D print synthetic muscles made from bovine serum albumin to realize 1 mm long contractile fibers. We show that pH-dependent contractions in these synthetic muscles follow parabolic force-length relationships similar to biological muscles. Achieved stress outputs of 0.78 ± 0.13 N cm −2 were within an order of magnitude of smooth and cardiac muscle. Stretch-shortening work loops performed under different strain rates in turn revealed a viscoelastic behavior and significant velocity dependence of work and net power, more similar to skeletal muscle. That an isotropic protein hydrogel can achieve such dynamics, reinforces the notion that these are not limited to sarcomere-level ordering and suggests a more general design space for non-canonical conformational dynamics to engineer performance improvements in artificial muscle materials.


  • Open Access

    Reconstituting organotypic 2D microtissue co-cultures via sequential stenciling

    by Kai Hirzel, Jasmin Cic, Stella Asmanidou, Nadja Schmohl, Roland E Kontermann, Satoshi Toda, Monilola A Olayioye, Andrew G Clark, Michael Heymann

    In mammalian organisms, native tissue function depends on precise spatial organization down to the cellular level. Reconstituting tissue architectures in 2D in vitro platforms can provide a means to study direct and indirect cell-cell interactions in a variety of tissue contexts while remaining compatible with high-throughput assays and high-resolution live imaging. We combine cost-effective stereolithography leveraging 3D printing with replica molding to stencil spatially defined, multicellular culture systems with sub-millimeter resolution onto planar substrates. The system is designed for ease of use, requires no complex fabrication setups and scales readily to 96-well plates. Sequential stencil application and removal under a biosafety cabinet enables controlled positioning of multiple cell types and supported the maturation of tissue assemblies. We demonstrate the utility of this stencil-based patterning strategy in three applications. First, we employ a combination of two circular stencils to recreate a structural feature characteristic for the tumor microenvironment of solid tumors: the encapsulation of colorectal cancer cells by cancer-associated fibroblasts. Resulting cell patternings reproduce native tissue dynamics of the densely packed tumor tissues, in which cancer-associated fibroblast cells actively compress the cancer cells and confer targeted therapy resistance. Second, we probe the synthetic, diffusible morphogen system synNotch in patterned cell patches, where GFP-releasing cells generate a ligand-dependent gradient. Third, we recapitulate the characteristic crypt-villus architecture of the mammalian intestine by patterning intestinal organoids within a stencil-restricted crypt region and allowing differentiating cells to collectively migrate along a designed villus axis. The presented strategy allows for rebuilding multicellular tissue architectures in vitro with biologically relevant spatial precision for high-throughput drug screenings and dissection of tissue-specific cellular interactions.

  • Open Access

    Upconversion Photoluminescence to Monitor Local Heat Release During Femtosecond Direct Laser Writing of Bioinks In Situ

    by Amirbahador Zeynali, Giuseppe Chirico, Michael Heymann

    Exothermic photopolymerization releases heat into the sample environment. Using NaYF 4 :Yb 3+ /Er 3+ upconversion nanoparticle (UCNP) photoluminescence and a colinear lithography and thermometry laser configuration, we monitor thermal signatures in the focal spot during femtosecond direct laser writing in real time. A statistical short‐pass filtering is introduced to reduce the standard error in temperature calibration compared to conventional Gaussian deconvolution. Thermometry performance of our set‐up achieved a relative sensitivity of 0.89–1.58% K −1 and a measurement uncertainty of 0.2–0.4 K for 2 Hz sample rates. With this, the effect of scan speed, laser power, and photoinitiator concentration on accompanying local heating could be followed. Nonlinearities and thermal runaway effects with transient temperature spikes above 120–140°C demonstrate the need for a stringent reduction of the thermal burden when writing aqueous bioinks for biomedical applications. Physiological conditions were maintained only for fast 20 µm/s scan speeds, which limited temperature quenches to not exceed physiological temperatures. This paves the way to improve process control and to optimize for laser‐assisted bioprinting and other related technologies.


  • Open Access

    Coaxial helium electrospray for single-particle imaging at X-ray free electron lasers

    by Safi Rafie-Zinedine, Joachim Schulz, Johan Bielecki, Michael Heymann

    Single-particle imaging at X-ray free-electron lasers relies on suitable sample injection of nanoscale macromolecules and particles into the gas phase at room temperature. A coaxial liquid-sheet strategy considerably extended the range of suitable samples to include conductivities from zero to 40000 µS cm−1 – a more than about an eightfold increase in range compared with conventional electrosprays. A helium chamber atmosphere in combination with an engineered gas-sheet protected aerosol formation against corona discharge and reduced background noise more than threefold. These results suggest new avenues to qualify ever more demanding biological and material science samples for single-particle imaging in the future.


  • Open Access

    Development of a flat jet delivery system for soft X-ray spectroscopy at MAX IV

    by Tamires Gallo, Luigi Adriano, Michael Heymann, Agnieszka Wrona, Noelle Walsh, Gunnar Öhrwall, Flavia Callefo, Slawomir Skruszewicz, Mahesh Namboodiri, Ricardo Marinho, et al.

    One of the most challenging aspects of X-ray research is the delivery of liquid sample flows into the soft X-ray beam. Currently, cylindrical microjets are the most commonly used sample injection systems for soft X-ray liquid spectroscopy. However, they suffer from several drawbacks, such as complicated geometry due to their curved surface. In this study, we propose a novel 3D-printed nozzle design by introducing microscopic flat sheet jets that provide micrometre-thick liquid sheets with high stability, intending to make this technology more widely available to users. Our research is a collaboration between the EuXFEL and MAX IV research facilities. This collaboration aims to develop and refine a 3D-printed flat sheet nozzle design and a versatile jetting platform that is compatible with multiple endstations and measurement techniques. Our flat sheet jet platform improves the stability of the jet and increases its surface area, enabling more precise scanning and differential measurements in X-ray absorption, scattering, and imaging applications. Here, we demonstrate the performance of this new arrangement for a flat sheet jet setup with X-ray photoelectron spectroscopy, photoelectron angular distribution, and soft X-ray absorption spectroscopy experiments performed at the photoemission endstation of the FlexPES beamline at MAX IV Laboratory in Lund, Sweden.


  • Open Access

    Enhancing electrospray ionization efficiency for particle transmission through an aerodynamic lens stack

    by Safi Rafie-Zinedine, Tej Varma Yenupuri, Lena Worbs, Filipe R. N. C. Maia, Michael Heymann, Joachim Schulz, Johan Bielecki

    This work investigates the performance of the electrospray aerosol generator at the European X-ray Free Electron Laser (EuXFEL). This generator is, together with an aerodynamic lens stack that transports the particles into the X-ray interaction vacuum chamber, the method of choice to deliver particles for single-particle coherent diffractive imaging (SPI) experiments at the EuXFEL. For these experiments to be successful, it is necessary to achieve high transmission of particles from solution into the vacuum interaction region. Particle transmission is highly dependent on efficient neutralization of the charged aerosol generated by the electrospray mechanism as well as the geometry in the vicinity of the Taylor cone. We report absolute particle transmission values for different neutralizers and geometries while keeping the conditions suitable for SPI experiments. Our findings reveal that a vacuum ultraviolet ionizer demonstrates a transmission efficiency approximately seven times greater than the soft X-ray ionizer used previously. Combined with an optimized orifice size on the counter electrode, we achieve >40% particle transmission from solution into the X-ray interaction region. These findings offer valuable insights for optimizing electrospray aerosol generator configurations and data rates for SPI experiments.


  • Open Access

    Multiscale Biofabrication: Integrating Additive Manufacturing with DNA‐Programmable Self‐Assembly

    by Anna C. Jäkel, Michael Heymann, Friedrich C. Simmel

    Structure and hierarchical organization are crucial elements of biological systems and are likely required when engineering synthetic biomaterials with life‐like behavior. In this context, additive manufacturing techniques like bioprinting have become increasingly popular. However, 3D bioprinting, as well as other additive manufacturing techniques, show limited resolution, making it difficult to yield structures on the sub‐cellular level. To be able to form macroscopic synthetic biological objects with structuring on this level, manufacturing techniques have to be used in conjunction with biomolecular nanotechnology. Here, a short overview of both topics and a survey of recent advances to combine additive manufacturing with microfabrication techniques and bottom‐up self‐assembly involving DNA, are given.


  • Open Access

    Megahertz pulse trains enable multi-hit serial femtosecond crystallography experiments at X-ray free electron lasers

    by Susannah Holmes, Henry J. Kirkwood, Richard Bean, Klaus Giewekemeyer, Andrew V. Martin, Marjan Hadian-Jazi, Max O. Wiedorn, Dominik Oberthür, Hugh Marman, Luigi Adriano, et al.

    The European X-ray Free Electron Laser (XFEL) and Linac Coherent Light Source (LCLS) II are extremely intense sources of X-rays capable of generating Serial Femtosecond Crystallography (SFX) data at megahertz (MHz) repetition rates. Previous work has shown that it is possible to use consecutive X-ray pulses to collect diffraction patterns from individual crystals. Here, we exploit the MHz pulse structure of the European XFEL to obtain two complete datasets from the same lysozyme crystal, first hit and the second hit, before it exits the beam. The two datasets, separated by <1 µs, yield up to 2.1 Å resolution structures. Comparisons between the two structures reveal no indications of radiation damage or significant changes within the active site, consistent with the calculated dose estimates. This demonstrates MHz SFX can be used as a tool for tracking sub-microsecond structural changes in individual single crystals, a technique we refer to as multi-hit SFX.